Confhusius: a robust and fully automatic calibration method for 3D freehand ultrasound.

Abstract:

:This paper describes a new robust and fully automatic method for calibration of three-dimensional (3D) freehand ultrasound called Confhusius (CalibratiON for FreeHand UltraSound Imaging USage). 3D Freehand ultrasound consists in mounting a position sensor on a standard probe. The echographic B-scans can be localized in 3D and compounded into a volume. However, especially for quantitative use, this process dramatically requires a calibration procedure that determines its accuracy and usefulness. Calibration aims at determining the transformation (translations, rotations, scaling) between the coordinates system of the echographic images and the coordinate system of the localization system. To calibrate, we acquire images of a phantom whose 3D geometrical properties are known. We propose a robust and fully automatic calibration method based on the Hough transform and robust estimators. Experiments have been done with synthetic and real sequences, and this calibration method is shown to be easy to perform, accurate, automatic and fast enough for clinical use.

journal_name

Med Image Anal

journal_title

Medical image analysis

authors

Rousseau F,Hellier P,Barillot C

doi

10.1016/j.media.2004.06.021

subject

Has Abstract

pub_date

2005-02-01 00:00:00

pages

25-38

issue

1

eissn

1361-8415

issn

1361-8423

pii

S1361-8415(04)00040-4

journal_volume

9

pub_type

杂志文章
  • Spatially variable Rician noise in magnetic resonance imaging.

    abstract::Magnetic resonance images tend to be influenced by various random factors usually referred to as "noise". The principal sources of noise and related artefacts can be divided into two types: arising from hardware (acquisition coil arrays, gradient coils, field inhomogeneity); and arising from the subject (physiological...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.12.002

    authors: Maximov II,Farrher E,Grinberg F,Shah NJ

    更新日期:2012-02-01 00:00:00

  • Computerized detection of pulmonary nodules in chest radiographs based on morphological features and wavelet snake model.

    abstract::We have developed a new computer-aided diagnosis scheme for automated detection of lung nodules in digital chest radiographs based on a combination of morphological features and the wavelet snake. In our scheme, two processes were applied in parallel to reduce the false-positive detections after initial nodule candida...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(02)00064-6

    authors: Keserci B,Yoshida H

    更新日期:2002-12-01 00:00:00

  • Statistical shape models for 3D medical image segmentation: a review.

    abstract::Statistical shape models (SSMs) have by now been firmly established as a robust tool for segmentation of medical images. While 2D models have been in use since the early 1990 s, wide-spread utilization of three-dimensional models appeared only in recent years, primarily made possible by breakthroughs in automatic dete...

    journal_title:Medical image analysis

    pub_type: 杂志文章,评审

    doi:10.1016/j.media.2009.05.004

    authors: Heimann T,Meinzer HP

    更新日期:2009-08-01 00:00:00

  • Advances and challenges in deformable image registration: From image fusion to complex motion modelling.

    abstract::Over the past 20 years, the field of medical image registration has significantly advanced from multi-modal image fusion to highly non-linear, deformable image registration for a wide range of medical applications and imaging modalities, involving the compensation and analysis of physiological organ motion or of tissu...

    journal_title:Medical image analysis

    pub_type: 社论

    doi:10.1016/j.media.2016.06.031

    authors: Schnabel JA,Heinrich MP,Papież BW,Brady SJM

    更新日期:2016-10-01 00:00:00

  • Automatic segmentation of 3D micro-CT coronary vascular images.

    abstract::Although there are many algorithms available in the literature aimed at segmentation and model reconstruction of 3D angiographic images, many are focused on characterizing only a part of the vascular network. This study is motivated by the recent emerging prospects of whole-organ simulations in coronary hemodynamics, ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2007.06.012

    authors: Lee J,Beighley P,Ritman E,Smith N

    更新日期:2007-12-01 00:00:00

  • Rubik's Cube+: A self-supervised feature learning framework for 3D medical image analysis.

    abstract::Due to the development of deep learning, an increasing number of research works have been proposed to establish automated analysis systems for 3D volumetric medical data to improve the quality of patient care. However, it is challenging to obtain a large number of annotated 3D medical data needed to train a neural net...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101746

    authors: Zhu J,Li Y,Hu Y,Ma K,Zhou SK,Zheng Y

    更新日期:2020-08-01 00:00:00

  • Classification of hemodynamics from dynamic-susceptibility-contrast magnetic resonance (DSC-MR) brain images using noiseless independent factor analysis.

    abstract::Dynamic-susceptibility-contrast (DSC) magnetic resonance imaging records signal changes on images when the injected contrast-agent particles pass through a human brain. The temporal signal changes on different brain tissues manifest distinct blood-supply patterns which are vital for the profound analysis of cerebral h...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2007.02.002

    authors: Chou YC,Teng MM,Guo WY,Hsieh JC,Wu YT

    更新日期:2007-06-01 00:00:00

  • An information theoretic approach for non-rigid image registration using voxel class probabilities.

    abstract::We propose two information theoretic similarity measures that allow to incorporate tissue class information in non-rigid image registration. The first measure assumes that tissue class probabilities have been assigned to each of the images to be registered by prior segmentation of both of them. One image is then non-r...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2005.03.004

    authors: D'Agostino E,Maes F,Vandermeulen D,Suetens P

    更新日期:2006-06-01 00:00:00

  • An efficient Riemannian statistical shape model using differential coordinates: With application to the classification of data from the Osteoarthritis Initiative.

    abstract::We propose a novel Riemannian framework for statistical analysis of shapes that is able to account for the nonlinearity in shape variation. By adopting a physical perspective, we introduce a differential representation that puts the local geometric variability into focus. We model these differential coordinates as ele...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2017.09.004

    authors: von Tycowicz C,Ambellan F,Mukhopadhyay A,Zachow S

    更新日期:2018-01-01 00:00:00

  • Explainable cardiac pathology classification on cine MRI with motion characterization by semi-supervised learning of apparent flow.

    abstract::We propose a method to classify cardiac pathology based on a novel approach to extract image derived features to characterize the shape and motion of the heart. An original semi-supervised learning procedure, which makes efficient use of a large amount of non-segmented images and a small amount of images segmented man...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.06.001

    authors: Zheng Q,Delingette H,Ayache N

    更新日期:2019-08-01 00:00:00

  • Deformable image registration by combining uncertainty estimates from supervoxel belief propagation.

    abstract::Discrete optimisation strategies have a number of advantages over their continuous counterparts for deformable registration of medical images. For example: it is not necessary to compute derivatives of the similarity term; dense sampling of the search space reduces the risk of becoming trapped in local optima; and (in...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.09.005

    authors: Heinrich MP,Simpson IJ,Papież BW,Brady SM,Schnabel JA

    更新日期:2016-01-01 00:00:00

  • Fusion of white and gray matter geometry: a framework for investigating brain development.

    abstract::Current neuroimaging investigation of the white matter typically focuses on measurements derived from diffusion tensor imaging, such as fractional anisotropy (FA). In contrast, imaging studies of the gray matter oftentimes focus on morphological features such as cortical thickness, folding and surface curvature. As a ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2014.06.013

    authors: Savadjiev P,Rathi Y,Bouix S,Smith AR,Schultz RT,Verma R,Westin CF

    更新日期:2014-12-01 00:00:00

  • Robust estimation of carotid artery wall motion using the elasticity-based state-space approach.

    abstract::The dynamics of the carotid artery wall has been recognized as a valuable indicator to evaluate the status of atherosclerotic disease in the preclinical stage. However, it is still a challenge to accurately measure this dynamics from ultrasound images. This paper aims at developing an elasticity-based state-space appr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2017.01.004

    authors: Gao Z,Xiong H,Liu X,Zhang H,Ghista D,Wu W,Li S

    更新日期:2017-04-01 00:00:00

  • A procedure to average 3D anatomical structures.

    abstract::Creating a feature-preserving average of three dimensional anatomical surfaces extracted from volume image data is a complex task. Unlike individual images, averages present right-left symmetry and smooth surfaces which give insight into typical proportions. Averaging multiple biological surface images requires carefu...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(00)00031-1

    authors: Subramanya K,Dean D

    更新日期:2000-12-01 00:00:00

  • PCA-based groupwise image registration for quantitative MRI.

    abstract::Quantitative magnetic resonance imaging (qMRI) is a technique for estimating quantitative tissue properties, such as the T1 and T2 relaxation times, apparent diffusion coefficient (ADC), and various perfusion measures. This estimation is achieved by acquiring multiple images with different acquisition parameters (or a...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.12.004

    authors: Huizinga W,Poot DH,Guyader JM,Klaassen R,Coolen BF,van Kranenburg M,van Geuns RJ,Uitterdijk A,Polfliet M,Vandemeulebroucke J,Leemans A,Niessen WJ,Klein S

    更新日期:2016-04-01 00:00:00

  • Predicting the progression of mild cognitive impairment using machine learning: A systematic, quantitative and critical review.

    abstract::We performed a systematic review of studies focusing on the automatic prediction of the progression of mild cognitive impairment to Alzheimer's disease (AD) dementia, and a quantitative analysis of the methodological choices impacting performance. This review included 172 articles, from which 234 experiments were extr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101848

    authors: Ansart M,Epelbaum S,Bassignana G,Bône A,Bottani S,Cattai T,Couronné R,Faouzi J,Koval I,Louis M,Thibeau-Sutre E,Wen J,Wild A,Burgos N,Dormont D,Colliot O,Durrleman S

    更新日期:2021-01-01 00:00:00

  • Self-similarity weighted mutual information: a new nonrigid image registration metric.

    abstract::Mutual information (MI) has been widely used as a similarity measure for rigid registration of multi-modal and uni-modal medical images. However, robust application of MI to deformable registration is challenging mainly because rich structural information, which are critical cues for successful deformable registration...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2013.12.003

    authors: Rivaz H,Karimaghaloo Z,Collins DL

    更新日期:2014-02-01 00:00:00

  • Quantification of the detailed cardiac left ventricular trabecular morphogenesis in the mouse embryo.

    abstract::During embryogenesis, a mammalian heart develops from a simple tubular shape into a complex 4-chamber organ, going through four distinct phases: early primitive tubular heart, emergence of trabeculations, trabecular remodeling and development of the compact myocardium. In this paper we propose a framework for standard...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.08.001

    authors: Paun B,Bijnens B,Cook AC,Mohun TJ,Butakoff C

    更新日期:2018-10-01 00:00:00

  • A variational framework for integrating segmentation and registration through active contours.

    abstract::Traditionally, segmentation and registration have been solved as two independent problems, even though it is often the case that the solution to one impacts the solution to the other. In this paper, we introduce a geometric, variational framework that uses active contours to simultaneously segment and register feature...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(03)00004-5

    authors: Yezzi A,Zöllei L,Kapur T

    更新日期:2003-06-01 00:00:00

  • Automated classification of lung bronchovascular anatomy in CT using AdaBoost.

    abstract::Lung CAD systems require the ability to classify a variety of pulmonary structures as part of the diagnostic process. The purpose of this work was to develop a methodology for fully automated voxel-by-voxel classification of airways, fissures, nodules, and vessels from chest CT images using a single feature set and cl...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2007.03.004

    authors: Ochs RA,Goldin JG,Abtin F,Kim HJ,Brown K,Batra P,Roback D,McNitt-Gray MF,Brown MS

    更新日期:2007-06-01 00:00:00

  • Gaussianization of Diffusion MRI Data Using Spatially Adaptive Filtering.

    abstract::Diffusion MRI magnitude data, typically Rician or noncentral χ distributed, is affected by the noise floor, which falsely elevates signal, reduces image contrast, and biases estimation of diffusion parameters. Noise floor can be avoided by extracting real-valued Gaussian-distributed data from complex diffusion-weighte...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101828

    authors: Liu F,Feng J,Chen G,Shen D,Yap PT

    更新日期:2021-02-01 00:00:00

  • Automated size-specific dose estimates using deep learning image processing.

    abstract::An automated vendor-independent system for dose monitoring in computed tomography (CT) medical examinations involving ionizing radiation is presented in this paper. The system provides precise size-specific dose estimates (SSDE) following the American Association of Physicists in Medicine regulations. Our dose managem...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101898

    authors: Juszczyk J,Badura P,Czajkowska J,Wijata A,Andrzejewski J,Bozek P,Smolinski M,Biesok M,Sage A,Rudzki M,Wieclawek W

    更新日期:2021-02-01 00:00:00

  • Disentangled representation learning in cardiac image analysis.

    abstract::Typically, a medical image offers spatial information on the anatomy (and pathology) modulated by imaging specific characteristics. Many imaging modalities including Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) can be interpreted in this way. We can venture further and consider that a medical image na...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101535

    authors: Chartsias A,Joyce T,Papanastasiou G,Semple S,Williams M,Newby DE,Dharmakumar R,Tsaftaris SA

    更新日期:2019-12-01 00:00:00

  • MR to ultrasound registration for image-guided prostate interventions.

    abstract::A deformable registration method is described that enables automatic alignment of magnetic resonance (MR) and 3D transrectal ultrasound (TRUS) images of the prostate gland. The method employs a novel "model-to-image" registration approach in which a deformable model of the gland surface, derived from an MR image, is r...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.11.003

    authors: Hu Y,Ahmed HU,Taylor Z,Allen C,Emberton M,Hawkes D,Barratt D

    更新日期:2012-04-01 00:00:00

  • Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

    abstract::Prostate brachytherapy is a treatment for prostate cancer using radioactive seeds that are permanently implanted in the prostate. The treatment success depends on adequate coverage of the target gland with a therapeutic dose, while sparing the surrounding tissue. Since seed implantation is performed under transrectal ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.06.001

    authors: Dehghan E,Lee J,Fallavollita P,Kuo N,Deguet A,Le Y,Clif Burdette E,Song DY,Prince JL,Fichtinger G

    更新日期:2012-10-01 00:00:00

  • Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images.

    abstract::This paper describes a method for the enhancement of curvilinear structures such as vessels and bronchi in three-dimensional (3-D) medical images. A 3-D line enhancement filter is developed with the aim of discriminating line structures from other structures and recovering line structures of various widths. The 3-D li...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(98)80009-1

    authors: Sato Y,Nakajima S,Shiraga N,Atsumi H,Yoshida S,Koller T,Gerig G,Kikinis R

    更新日期:1998-06-01 00:00:00

  • Cardiac image modelling: Breadth and depth in heart disease.

    abstract::With the advent of large-scale imaging studies and big health data, and the corresponding growth in analytics, machine learning and computational image analysis methods, there are now exciting opportunities for deepening our understanding of the mechanisms and characteristics of heart disease. Two emerging fields are ...

    journal_title:Medical image analysis

    pub_type: 社论,评审

    doi:10.1016/j.media.2016.06.027

    authors: Suinesiaputra A,McCulloch AD,Nash MP,Pontre B,Young AA

    更新日期:2016-10-01 00:00:00

  • A comparison of freehand three-dimensional ultrasound reconstruction techniques.

    abstract::Three-dimensional freehand ultrasound imaging produces a set of irregularly spaced B-scans, which are typically reconstructed on a regular grid for visualization and data analysis. Most standard reconstruction algorithms are designed to minimize computational requirements and do not exploit the underlying shape of the...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(99)80028-0

    authors: Rohling R,Gee A,Berman L

    更新日期:1999-12-01 00:00:00

  • Objective and expert-independent validation of retinal image registration algorithms by a projective imaging distortion model.

    abstract::Fundus camera imaging of the retina is widely used to diagnose and manage ophthalmologic disorders including diabetic retinopathy, glaucoma, and age-related macular degeneration. Retinal images typically have a limited field of view, and multiple images can be joined together using an image registration technique to f...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.04.001

    authors: Lee S,Reinhardt JM,Cattin PC,Abràmoff MD

    更新日期:2010-08-01 00:00:00

  • Noise reduction in diffusion MRI using non-local self-similar information in joint x-q space.

    abstract::Diffusion MRI affords valuable insights into white matter microstructures, but suffers from low signal-to-noise ratio (SNR), especially at high diffusion weighting (i.e., b-value). To avoid time-intensive repeated acquisition, post-processing algorithms are often used to reduce noise. Among existing methods, non-local...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.01.006

    authors: Chen G,Wu Y,Shen D,Yap PT

    更新日期:2019-04-01 00:00:00