Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

Abstract:

BACKGROUND:The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. METHODS:We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. RESULTS:The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P <0.001). Regression and Bland-Altman analyses suggested that the LIAISON 25OHD assay reads lower than the DiaSorin RIA at low concentrations but higher at high concentrations. However, the cutoff (50 nmol/L) used in our laboratories to define vitamin D insufficiency with the DiaSorin RIA is applicable to the LIAISON 25OHD assay. In 927 healthy individuals, the 3rd-97th percentile intervals were 3-80 ng/L and 13-151 nmol/L for the LIAISON PTH and 25OHD concentrations, respectively. However, 506 individuals (54.6%) were vitamin D-insufficient; we therefore considered only the 421 individuals with a LIAISON 25OHD >50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). CONCLUSIONS:Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Souberbielle JC,Fayol V,Sault C,Lawson-Body E,Kahan A,Cormier C

doi

10.1373/clinchem.2004.037606

subject

Has Abstract

pub_date

2005-02-01 00:00:00

pages

395-400

issue

2

eissn

0009-9147

issn

1530-8561

pii

clinchem.2004.037606

journal_volume

51

pub_type

杂志文章
  • Ligand assays: from electrophoresis to miniaturized microarrays.

    abstract::The main developments in the "ligand assay" field in which I have been involved are traced. These include the original development of "first generation" competitive assays relying on radiolabeled analyte markers; the development of the first "second generation", noncompetitive (ultrasensitive) methods, which rely on t...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Ekins RP

    更新日期:1998-09-01 00:00:00

  • Comparability of results by simplified methods for measuring serum lipoprotein cholesterol in a pediatric population.

    abstract::We compared serum lipoprotein cholesterol concentrations in a randomly selected subsample (n = 406) population of children (ages 5 to 17 years), as measured by the heparin-Ca2+ and the heparin-Mn2+ precipitation methods. Statistical analysis showed significant differences between results by these methods, especially i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Srinivasan SR,Foster TA,Berenson GS

    更新日期:1980-10-01 00:00:00

  • Gene probes: application to prenatal and postnatal diagnosis of genetic disease.

    abstract::Gene probes can now be used to detect a variety of mutations that produce single-gene disorders. In present clinical practice, restriction endonuclease analysis is used for the prenatal diagnosis of sickle cell anemia, alpha-thalassemia, and beta-thalassemia. Direct detection of the mutation is possible in alpha-thala...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kazazian HH Jr

    更新日期:1985-09-01 00:00:00

  • For goodness' sake: expected therapeutic benefit as a basis for healthcare delivery.

    abstract::The current debate on our healthcare system has focused primarily on the cost of care. Because of drastically rising costs and their burden on our economy, government and the private sector have developed many approaches to reduce these costs. Managed care, special contracting arrangements, and government fiat have al...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Denton TA,Diamond GA

    更新日期:1995-05-01 00:00:00

  • Novel, aberrantly truncated isoform of serum CD13 in a family with high serum aminopeptidase N (CD13) activity.

    abstract:BACKGROUND:We previously reported a family in which the propositus and both her father and paternal grandmother had high serum aminopeptidase N (CD13; EC 3.4.11.2) activity (autosomal dominant). The molecular mass of the serum CD13 polypeptide of the propositus was larger than that of normal CD13, suggesting either a m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kawai M,Hara Y,Miyazato I,Hosaki S

    更新日期:2001-02-01 00:00:00

  • Clinical evaluation of a radiometric assay specific for creatine kinase isoenzyme MB.

    abstract::A new radiometric assay specific for creatine kinase isoenzyme MB was evaluated with respect to its precision and agreement with a conventional electrophoretic CK-MB assay for the diagnosis of myocardial infarction. The reference interval we find for serum CK-MB in healthy subjects is 0--30 micrograms/L. The coefficie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kwong TC,Rothbard RL,Biddle TL

    更新日期:1981-06-01 00:00:00

  • Intravascular monitoring: problems and promise.

    abstract::Intravascular monitoring of arterial blood gases provides the means to detect precipitous change in cardiopulmonary function almost instantaneously, promising major improvement in the ability to manage critically ill patients. Attempts to miniaturize and repackage conventional electrodes for continuous intravascular u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Halbert SA

    更新日期:1990-08-01 00:00:00

  • Planar Functionalized Surfaces for Direct Immunoaffinity Desorption/Ionization Mass Spectrometry.

    abstract:BACKGROUND:Recent studies show that the haptoglobin phenotype in individuals with diabetes mellitus is an important factor for predicting the risk of myocardial infarction, cardiovascular death, and stroke. Current methods for haptoglobin phenotyping include PCR and gel electrophoresis. A need exists for a reliable met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.244004

    authors: Pompach P,Nováková J,Kavan D,Benada O,Růžička V,Volný M,Novák P

    更新日期:2016-01-01 00:00:00

  • Time-course of cigarette smoke contamination of clinical hydrogen breath-analysis tests.

    abstract::The time-course of the contamination of exogenous hydrogen from cigarette smoke on postprandial breath hydrogen concentration was evaluated in 10 subjects, six regular smokers and four occasional smokers. Breath hydrogen values were determined by gas chromatography 10 min, 5 min, and immediately prior to smoking a fil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosenthal A,Solomons NW

    更新日期:1983-11-01 00:00:00

  • Flow-injection analysis for malondialdehyde in plasma with the thiobarbituric acid reaction.

    abstract::A simple, precise, and rapid method to measure plasma malondialdehyde (MDA) was developed by use of solvent extraction--flow-injection analysis. The reagent solution, containing thiobarbituric acid (TBA), 5 g/L in 100 mL/L phosphoric acid, and extraction solvent (methylisobutyl ketone, MIBK) were propelled with a doub...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ikatsu H,Nakajima T,Murayama N,Korenaga T

    更新日期:1992-10-01 00:00:00

  • Multi-wavelength analyses of second-derivative spectra for rapid determination of acetaminophen in serum.

    abstract::Measurement of acetaminophen by analysis of the second derivative of its spectrum is specific and sensitive. The method of extraction and the use of just one phosphate buffer as reagent makes this method very convenient. Readings are reliable from 10 to 1500 mg/L. A turnaround time of 20 min makes this method well sui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dingeon B,Charvin MA,Quenard MT,Thome H

    更新日期:1988-06-01 00:00:00

  • Cardiac troponin I associated with the development of unrecognized myocardial infarctions detected with MRI.

    abstract:BACKGROUND:Late enhancement MRI (LE-MRI) and cardiac troponin I (cTnI) are sensitive methods to detect subclinical myocardial injury. We sought to investigate the relation between plasma concentrations of cTnI measured with a high-sensitivity assay (hs-cTnI) and the development of unrecognized myocardial infarctions (U...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2014.222430

    authors: Barbier CE,Themudo R,Bjerner T,Johansson L,Lindahl B,Venge P,Lind L,Ahlström H

    更新日期:2014-10-01 00:00:00

  • Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

    abstract:BACKGROUND:The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.107508

    authors: Shaikh A,Seegmiller JC,Borland TM,Burns BE,Ladwig PM,Singh RJ,Kumar R,Larson TS,Lieske JC

    更新日期:2008-09-01 00:00:00

  • Detection of a soluble form of BACE-1 in human cerebrospinal fluid by a sensitive activity assay.

    abstract:BACKGROUND:Formation of deposits of the insoluble amyloid beta-peptide is believed to be causally related with neurodegeneration in Alzheimer disease (AD). The beta-peptide originates from a larger amyloid precursor protein (APP) by the action of proteolytic enzymes. The first proteolytic event leading to amyloid forma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.066720

    authors: Verheijen JH,Huisman LG,van Lent N,Neumann U,Paganetti P,Hack CE,Bouwman F,Lindeman J,Bollen EL,Hanemaaijer R

    更新日期:2006-06-01 00:00:00

  • Prognostic value of chromogranin A at admission in critically ill patients: a cohort study in a medical intensive care unit.

    abstract:BACKGROUND:Risk assessments of patients should be based on objective variables, such as biological markers that can be measured routinely. The acute response to stress causes the release of catecholamines from the adrenal medulla accompanied by chromogranin A (CGA). To date, no study has evaluated the prognostic value ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.102442

    authors: Zhang D,Lavaux T,Voegeli AC,Lavigne T,Castelain V,Meyer N,Sapin R,Aunis D,Metz-Boutigue MH,Schneider F

    更新日期:2008-09-01 00:00:00

  • Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

    abstract::Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garber CC

    更新日期:1981-08-01 00:00:00

  • Distinguishing Intake of New Synthetic Cannabinoids ADB-PINACA and 5F-ADB-PINACA with Human Hepatocyte Metabolites and High-Resolution Mass Spectrometry.

    abstract:BACKGROUND:ADB-PINACA and its 5-fluoropentyl analog 5F-ADB-PINACA are among the most potent synthetic cannabinoids tested to date, with several severe intoxication cases. ADB-PINACA and 5F-ADB-PINACA have a different legal status, depending on the country. Synthetic cannabinoid metabolites predominate in urine, making ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.267575

    authors: Carlier J,Diao X,Scheidweiler KB,Huestis MA

    更新日期:2017-05-01 00:00:00

  • Effect of lyophilization on results of five enzymatic methods for cholesterol.

    abstract::We studied the effect of lyophilization of serum pools on the determination of cholesterol with the enzymatic methods used in five automated analyzers: SMAC (Technicon), the RA-1000 (Technicon), the aca (Du Pont), the TDx (Abbott), and the Ektachem 700P (Kodak). We prepared two serum pools: pool A (2.2 g/L) and pool B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Chesler R,Elin RJ

    更新日期:1989-07-01 00:00:00

  • Simultaneous on-line measurement of blood K+, Ca2+, Na+, and pH with a four-function ChemFET integrated-circuit sensor.

    abstract::On-line, simultaneous measurement of blood K+, Ca2+, Na+, and pH has been achieved by using a quadruple-function ChemFET (chemical-sensitive field-effect transistor) integrated-circuit sensor. Blood is withdrawn from the subject through an actively heparinized, dual-lumen cannula and passed into a flow-cell containing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sibbald A,Covington AK,Carter RF

    更新日期:1984-01-01 00:00:00

  • Fully enzymatic method for determining 1,5-anhydro-D-glucitol in serum.

    abstract::We have developed a fully enzymatic method to measure 1,5 anhydro-D-glucitol (1,5-AG) in serum through use of pyranose oxidase (PROD: EC 1.1.3.10), glucokinase (EC 2.7.1.2), and an ATP-regenerating system. In a previous report (Clin Chem 1989;35:2039-43) the glucose interfering with the measurement of 1,5-AG was remov...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fukumura Y,Tajima S,Oshitani S,Ushijima Y,Kobayashi I,Hara F,Yamamoto S,Yabuuchi M

    更新日期:1994-11-01 00:00:00

  • Immunochemical approach to the question of inactive subunits in cases of lactate dehydrogenase B subunit deficiency.

    abstract::If there were enzymatically inactive B subunits in a solution containing lactate dehydrogenase (LD) B4 prepared from the hemolysates of heterozygous individuals with LD-B subunit deficiency, the inactive subunits would compete with normal subunits for antibodies to the B4 subunit. Using the activity of normal LD-B4 as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maekawa M,Sudo K,Kanno T

    更新日期:1986-01-01 00:00:00

  • In vitro effects of a novel hemoglobin-based oxygen carrier on routine chemistry, therapeutic drug, coagulation, hematology, and blood bank assays.

    abstract::Red blood cell (RBC) replacement solutions are being developed as alternatives to allogeneic RBC use in blood transfusions in the treatment of massive trauma, to achieve hemodynamic stability during elective surgery, and to increase oxygen-carrying capacity in anemia. Hemoglobin-based oxygen carrier (HBOC)-201 (Biopur...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Callas DD,Clark TL,Moreira PL,Lansden C,Gawryl MS,Kahn S,Bermes EW Jr

    更新日期:1997-09-01 00:00:00

  • A more sensitive automated method for determination of ornithine carbamoyltransferase activity in human serum.

    abstract::Ornithine carbamoyltransferase (EC 2.1.3.3) activity is a sensitive, specific indicator of hepatocellular injury. This paper describes development of an improved automated procedure for measurement of this activity. Triethanolamine-ethylenediaminetetraacetate is used as a buffer, and activity is determined by measurin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Clayson KJ,Fine JS,Strandjord PE

    更新日期:1975-05-01 00:00:00

  • Enzyme immunoassay for intact human insulin in serum or plasma.

    abstract::We describe an enzyme-linked two-site immunoassay for quantitation of intact insulin in human serum and plasma. The method uses two murine monoclonal antibodies that bind to two different epitopes on the insulin molecule. The immunoassay is specific. Human proinsulin is not bound by the antibodies, and the binding of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andersen L,Dinesen B,Jørgensen PN,Poulsen F,Røder ME

    更新日期:1993-04-01 00:00:00

  • Serum albumin: recent progress in the understanding of its structure and biosynthesis.

    abstract::Major discoveries have been made in the past few years on the structure and mode of biosynthesis of serum albumin. The complete amino acid sequence of this protein has been determined, and its covalent structure shown to be a single peptide chain grouped into a series of nine disulfide-bonded loops. These loops appear...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Peters T Jr

    更新日期:1977-01-01 00:00:00

  • Nitrate determination in biological fluids by an enzymatic one-step assay with nitrate reductase.

    abstract::We report a simple, enzymatic, end point method for determining nitrate in serum and urine with use of nitrate reductase from Aspergillus sp. (EC 1.6.6.2). The decrease in absorbance at 340 nm as a result of the oxidation of beta-NADPH is measured. We used FAD as a supplementary electron carrier and added an internal ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bories PN,Bories C

    更新日期:1995-06-01 00:00:00

  • Influence of intermediate-density lipoproteins on the accuracy of the Friedewald formula.

    abstract::Values of low-density lipoprotein (LDL) cholesterol (C) according to the Friedewald formula (Clin Chem 1972;18:499-502) were compared with those obtained by lipoprotein fractionation in 98 healthy subjects (control group), 135 specimens from patients with peripheral vascular and cerebrovascular disease (atheroscleroti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sentí M,Pedro-Botet J,Nogués X,Rubiés-Prat J

    更新日期:1991-08-01 00:00:00

  • Specific micro-radioimmunoassay for prednisolone in serum.

    abstract::Use of an 125I radioimmunoassay involving antiserum coupled to magnetizable cellulose, after prednisolone-21-phosphate interference is removed by dichloromethane extraction at pH 7.4 and endogenous glucocorticoid interference is removed by selective chemical derivatization with Girard's Reagent T [(carboxymethyl)trime...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Olivesi A,Smith DS,White GW,Pourfarzaneh M

    更新日期:1983-07-01 00:00:00

  • Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an emergency department chest pain population.

    abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.127241

    authors: Kavsak PA,Wang X,Ko DT,MacRae AR,Jaffe AS

    更新日期:2009-10-01 00:00:00

  • Automated measurement of alpha-amylase isoenzymes with 6(3)-deoxymaltotriose as selective amylase inhibitor.

    abstract::We developed an automated method for measurement of alpha-amylase isoenzymes in serum by a single kinetic assay (SKA) and a double kinetic assay (DKA) with 2-chloro-4-nitrophenyl-6(5)-azido-6(5)-deoxy-beta-maltopentaoside as a substrate and 6(3)-deoxymaltotriose (DOG3) as a novel selective amylase inhibitor. DOG3 show...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Uchida R,Tokutake S,Motoyama Y,Hosoi K,Yamaji N

    更新日期:1995-04-01 00:00:00