Evaluation of human serum albumin cobalt binding assay for the assessment of myocardial ischemia and myocardial infarction.

Abstract:

BACKGROUND:Clinical diagnoses were correlated with results of a Co(II)-albumin binding assay in 167 patients treated at an emergency department of a health maintenance organization. METHODS:Patients were evaluated as being nonischemic or potentially ischemic through standard coronary disease indicators [creatine kinase (CK), CK-MB, cardiac troponin I, and electrocardiographic findings] and were tested by a Co(II)-albumin binding assay. Samples were tested anonymously, and the study was double-blinded. The sensitivity and specificity of this assay for the detection of ischemia were evaluated by ROC curve analysis. Known Co(II) binding sites on albumin were analyzed by N-terminal amino acid sequencing. RESULTS:The mean absorbance units (ABSU) +/- 2 SD for non-myocardial ischemic and myocardial ischemic individuals measured at 470 nm were 0.43 +/- 0.10 and 0.63 +/- 0.25, respectively (P <0.0001). The area under the ROC curve was 0.95 [95% confidence interval (CI), 0.92-0.99], and at a cutoff value of 0.50 ABSU, sensitivity and specificity were 88% (78-94%) and 94% (86-98%), respectively, suggesting a high distinction between the two groups. When we compared non-acute myocardial infarction (AMI) and AMI ischemic individuals, the area under the ROC curve was 0.66 (95% CI, 0.53-0.79) and was considered a poor discriminator between these two groups. N-Terminal amino acid sequencing data for purified albumin showed normal amino acid residues for six of seven high-ABSU (> or =0.70) individuals and one nonischemic individual tested. However, only one individual with a high ABSU (0.80) had two missing amino acid residues (DA) from the N-terminal region. Clinical diagnosis for this patient did not reveal an ischemic event. CONCLUSIONS:The Co(II)-albumin binding test may serve as a useful diagnostic tool in emergency facilities for the assessment of myocardial ischemia. High and low ABSU were associated with myocardial ischemic individuals and non-myocardial ischemic individuals, respectively. However, the Co(II)-albumin binding was a poor discriminator between ischemic individuals with and without MI.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Bhagavan NV,Lai EM,Rios PA,Yang J,Ortega-Lopez AM,Shinoda H,Honda SA,Rios CN,Sugiyama CE,Ha CE

doi

10.1373/49.4.581

subject

Has Abstract

pub_date

2003-04-01 00:00:00

pages

581-5

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

49

pub_type

临床试验,杂志文章
  • Metabolic response of humans to ingestion of nicotinic acid and nicotinamide.

    abstract::The identification of nicotinamide-N1-oxide as a metabolite in the urine of a schizophrenic patient prompted a study of the relative metabolism of nicotinic acid and nicotinamide in mental patients and healthy volunteers. Metabolites quantified included N1-methyl-2-pyridone-5-carboxamide, N1-methyl-4-pyridone-3-carbox...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mrochek JE,Jolley RL,Young DS,Turner WJ

    更新日期:1976-11-01 00:00:00

  • Creatine kinase BB: a new tumor-associated marker.

    abstract::Creatine kinase isoenzyme BB (CK-BB) is found in the serum of patients with various types of cancer. Using both radioimmunoassay and agarose electrophoresis, we found abnormal amounts of this isoenzyme in the serum of 15 of 17 patients with untreated prostatic carcinoma. Among patients with other types of adenocarcino...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Zweig MH,Van Steirteghem AC,Tökés ZA

    更新日期:1979-08-01 00:00:00

  • Estimate of uncertainty of measurement from a single-laboratory validation study: application to the determination of lead in blood.

    abstract:BACKGROUND:Lead is an environmental pollutant, and human exposure is assessed by monitoring lead concentrations in blood. Because the main source of environmental exposure has been the use of leaded gasoline, its phase-out has led to decreased lead concentrations in the general population. Therefore, validated analytic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.029223

    authors: Patriarca M,Castelli M,Corsetti F,Menditto A

    更新日期:2004-08-01 00:00:00

  • Chemometrics: measurement reliability.

    abstract::Applying the principles of chemometrics can lead to development of a powerful, simple, comprehensive system for characterizing measurement reliability of analytical processes. The system described here consists of a format for specifications, definitions, and decision rules for evaluating and comparing analytical proc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Castañeda-Méndez K

    更新日期:1988-12-01 00:00:00

  • Automated enhanced latex agglutination assay for rheumatoid factors in serum.

    abstract::This improved assay of rheumatoid factors in serum, described here for use with the Baker "Encore" centrifugal analyzer, is efficient, with 250-sample throughput per hour; reproducible, with between-batch CV = 5% and within-batch CV = 2% (mid-assay range); and results correlate well (r = 0.9) with those by other metho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkles JW,Lunec J,Gray L

    更新日期:1989-02-01 00:00:00

  • Immunological measurement of transforming growth factor-beta 1 (TGF-beta1) in blood; assay development and comparison.

    abstract::Development of a new, sensitive immunoassay for measuring transforming growth factor beta 1 (TGF-beta1) is described and compared with four commercially available TGF-beta1 immunoassays. Preanalytical conditions were evaluated. The nonlinearity found in serum or plasma is due to masking of TGF-beta1 by binding protein...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kropf J,Schurek JO,Wollner A,Gressner AM

    更新日期:1997-10-01 00:00:00

  • Interference by p-hydroxyphenobarbital in the 125I-radioimmunoassay of serum and urinary phenobarbital.

    abstract::A radioimmunoassay for barbiturates is shown to be equally sensitive to phenobarbital and its major urinary metabolite, p-hydroxyphenobarbital, in serum and urine. Interference by the metabolite can be essentially eliminated by selectively extracting phenobarbital into chloroform. The extraction efficiency of the meth...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Viswanathan CT,Booker HE,Welling PG

    更新日期:1977-05-01 00:00:00

  • Cannabinoids in exhaled breath following controlled administration of smoked cannabis.

    abstract:BACKGROUND:Δ(9)-Tetrahydrocannabinol (THC), 11-nor-9-carboxy-THC (THCCOOH), and cannabinol (CBN) were measured in breath following controlled cannabis smoking to characterize the time course and windows of detection of breath cannabinoids. METHODS:Exhaled breath was collected from chronic (≥4 times per week) and occas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.207407

    authors: Himes SK,Scheidweiler KB,Beck O,Gorelick DA,Desrosiers NA,Huestis MA

    更新日期:2013-12-01 00:00:00

  • Clinical pharmacology of anti-epileptic drugs: a summary of current information.

    abstract::This compendium represents what we believe to be the most current and reliable pharmacological data on anticonvulsant drugs. The information presented is derived from determinations of the drugs in plasma or serum by gas--liquid chromatography in studies of the efficacy of anti-epileptic agents. We present information...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Leal KW,Troupin AS

    更新日期:1977-11-01 00:00:00

  • Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins.

    abstract::Fast lipoprotein chromatography (FLPC) is a novel method for quantifying lipoproteins. Plasma proteins are separated by fast-flow gel filtration. Lipoproteins are detected by post-column derivatization with an enzymatic cholesterol reagent. FLPC resolves very-low-, low-, and high-density lipoproteins (VLDL, LDL, and H...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: März W,Siekmeier R,Scharnagl H,Seiffert UB,Gross W

    更新日期:1993-11-01 00:00:00

  • Continuous-flow (Autoanalyzer I) analysis for plasma thiocyanate as an index to tobacco smoking.

    abstract::We describe a procedure for determining thiocyanate in plasma with a Technicon AutoAnalyzer I, modified with a 50-mm tubular flow cell to increase the sensitivity of thiocyanate detection. The procedure is suitable for distinguishing cigarette smokers from non-smokers, the mean for smokers being 151 (SD 43) micromol/L...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dalferes ER Jr,Webber LS,Radhakrishnamurthy B,Berenson GS

    更新日期:1980-03-01 00:00:00

  • Tentacle Probes: differentiation of difficult single-nucleotide polymorphisms and deletions by presence or absence of a signal in real-time PCR.

    abstract:BACKGROUND:False-positive results are a common problem in real-time PCR identification of DNA sequences that differ from near neighbors by a single-nucleotide polymorphism (SNP) or deletion. Because of a lack of sufficient probe specificity, post-PCR analysis, such as a melting curve, is often required for mutation dif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.091488

    authors: Satterfield BC,Kulesh DA,Norwood DA,Wasieloski LP Jr,Caplan MR,West JA

    更新日期:2007-12-01 00:00:00

  • Specific 125I-radioimmunoassay for cholyglycine, a bile acid, in serum.

    abstract::The concentration of the conjugated bile acid, cholylglycine, in serum is a sensitive and specific indicator of hepatic function. We describe a convenient, specific, and precise radioimmunoassay for cholylglycine, in which 125I-labeled cholylglycyltyrosine is used as tracer. In addition, a blocking agent in the buffer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller P,Weiss S,Cornell M,Dockery J

    更新日期:1981-10-01 00:00:00

  • Use of magnetic circular dichroism spectroscopy for biologic monitoring of occupational exposures to toxicants.

    abstract::Zinc protoporphyrin is the predominent fluorescent porphyrin accumulating in erythrocytes as a result of chronic lead absorption or iron-deficiency anemia. Although diagnostic concentrations or thresholds for it in erythrocytes have been inferred, normal adult averages have not been established. We quantitatively asse...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Zygowicz ER,Hollebone BR,Perkins HM

    更新日期:1980-09-01 00:00:00

  • Measurement of prostate-specific antigen by radioimmunoassay.

    abstract::We describe the performance of an RIA for the measurement of prostate-specific antigen (PA). Between-assay precision (CV) for control sera with various analyte concentrations was as follows: mean = 1.67 micrograms/L, CV = 7.1%; mean = 4.47 micrograms/L, CV = 5.6%; mean = 7.15 micrograms/L, CV = 5.5% (n = 19 each). Ana...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Liedtke RJ,Batjer JD

    更新日期:1984-05-01 00:00:00

  • A method for direct estimation of imprecision profiles, with reference to immunoassay data.

    abstract::A three-parameter model for directly estimating imprecision profiles from replicated immunoassay results is compared with a six-parameter indirect profile model obtained by the usual method of combining error in the raw response measurements with the slope of the standard curve. Direct estimation is likely to be less ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sadler WA,Smith MH,Legge HM

    更新日期:1988-06-01 00:00:00

  • Measurement of the energy-generating capacity of human muscle mitochondria: diagnostic procedure and application to human pathology.

    abstract:BACKGROUND:Diagnosis of mitochondrial disorders usually requires a muscle biopsy to examine mitochondrial function. We describe our diagnostic procedure and results for 29 patients with mitochondrial disorders. METHODS:Muscle biopsies were from 43 healthy individuals and 29 patients with defects in one of the oxidativ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.062414

    authors: Janssen AJ,Trijbels FJ,Sengers RC,Wintjes LT,Ruitenbeek W,Smeitink JA,Morava E,van Engelen BG,van den Heuvel LP,Rodenburg RJ

    更新日期:2006-05-01 00:00:00

  • Use of a quality-control plasma sample to decrease interassay variation in radioimmunoassays of apolipoprotein A-I.

    abstract::The apolipoprotein A-I (apo A-I) radioimmunoassay established in our laboratory involves use of purified apo A-I as the primary standard for quantifying apo A-I in plasma and a pooled plasma (quality-control sample) as a secondary standard to decrease interassay variation. The measured values for apo A-I increased ove...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Au YP,Hallaway BJ,Kottke BA

    更新日期:1986-07-01 00:00:00

  • Addition of triglyceride to serum for use in quality control and reference.

    abstract::We describe a simple method in which a water-soluble mixture of triocatanoin and a surfactant, "Triton X-114," are used in preparing solutions of triglycerides (triacylglycerols) in either human serum, solutions of albumin, or water. Analytical recovery added triglyceride was quantitative by two methods. The addition ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bonderman DP,Proksch GJ,Bonderman PW

    更新日期:1976-08-01 00:00:00

  • Optimized serum pancreolauryl test for differentiating patients with and without chronic pancreatitis.

    abstract::The serum pancreolauryl test has limited sensitivity for detecting mild pancreatic insufficiency. The aim of this study was to optimize the serum pancreolauryl test so as to increase the probability of positive results in patients with chronic pancreatitis. The study had three parts. First, the sampling time was optim...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Domínguez-Muñoz JE,Malfertheiner P

    更新日期:1998-04-01 00:00:00

  • Bias in sensitivity and specificity caused by data-driven selection of optimal cutoff values: mechanisms, magnitude, and solutions.

    abstract:BACKGROUND:Optimal cutoff values for tests results involving continuous variables are often derived in a data-driven way. This approach, however, may lead to overly optimistic measures of diagnostic accuracy. We evaluated the magnitude of the bias in sensitivity and specificity associated with data-driven selection of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.096032

    authors: Leeflang MM,Moons KG,Reitsma JB,Zwinderman AH

    更新日期:2008-04-01 00:00:00

  • Critical assessment of phospholipid measurement in amniotic fluid.

    abstract::We assessed several methods of inorganic phosphate assay for their suitability in estimating phospholipids in digested extracts of amniotic fluids. The extraction and digestion procedures used for phospholipids from amniotic fluid were also examined critically. The effect of contamination by blood or obstetric cream h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Badham LP,Worth HG

    更新日期:1975-09-01 00:00:00

  • Evaluation of preanalytical variables associated with measurement of prothrombin fragment 1.2.

    abstract::We have used a monoclonal antibody-based ELISA for plasma prothrombin fragment 1.2 (F1.2) to establish appropriate sample collection and storage conditions for this biomarker of thrombin generation. F1.2 concentrations were not altered by exogenous factor Xa, thrombin, or thromboplastin if blood was collected by routi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Greenberg CS,Hursting MJ,Macik BG,Ortel TL,Kane WH,Moore BM

    更新日期:1994-10-01 00:00:00

  • Circulating human hepcidin-25 concentrations display a diurnal rhythm, increase with prolonged fasting, and are reduced by growth hormone administration.

    abstract:BACKGROUND:Hepcidin-25 reduces iron absorption by binding to the intestinal iron transporter ferroportin and causing its degradation. Currently, little is known about the basal regulation of circulating hepcidin-25. In addition, although erythropoietin administration has been reported to decrease the circulating hepcid...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.186866

    authors: Troutt JS,Rudling M,Persson L,Ståhle L,Angelin B,Butterfield AM,Schade AE,Cao G,Konrad RJ

    更新日期:2012-08-01 00:00:00

  • Diagnostic utility of C-terminal parathyrin measurement as compared with measurements of N-terminal parathyrin and calcium in serum.

    abstract::We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal ho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simon M,Cuan J

    更新日期:1980-11-01 00:00:00

  • Sex and age differences in lipoprotein subclasses measured by nuclear magnetic resonance spectroscopy: the Framingham Study.

    abstract:BACKGROUND:The sex differential in coronary heart disease (CHD) risk, which is not explained by male/female differences in lipid and lipoprotein concentrations, narrows with age. We examined whether this differential CHD risk might, in part, be attributable to the sizes of lipoprotein particles or concentrations of lip...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.032763

    authors: Freedman DS,Otvos JD,Jeyarajah EJ,Shalaurova I,Cupples LA,Parise H,D'Agostino RB,Wilson PW,Schaefer EJ

    更新日期:2004-07-01 00:00:00

  • Cardiac troponin I associated with the development of unrecognized myocardial infarctions detected with MRI.

    abstract:BACKGROUND:Late enhancement MRI (LE-MRI) and cardiac troponin I (cTnI) are sensitive methods to detect subclinical myocardial injury. We sought to investigate the relation between plasma concentrations of cTnI measured with a high-sensitivity assay (hs-cTnI) and the development of unrecognized myocardial infarctions (U...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2014.222430

    authors: Barbier CE,Themudo R,Bjerner T,Johansson L,Lindahl B,Venge P,Lind L,Ahlström H

    更新日期:2014-10-01 00:00:00

  • Inadequate hemolysis of erythrocytes on reagent strips at low pH causes false-negative readings.

    abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levin K,Engström I

    更新日期:1984-11-01 00:00:00

  • Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone.

    abstract:BACKGROUND:Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and childr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052167

    authors: Kushnir MM,Rockwood AL,Roberts WL,Pattison EG,Bunker AM,Fitzgerald RL,Meikle AW

    更新日期:2006-01-01 00:00:00

  • For goodness' sake: expected therapeutic benefit as a basis for healthcare delivery.

    abstract::The current debate on our healthcare system has focused primarily on the cost of care. Because of drastically rising costs and their burden on our economy, government and the private sector have developed many approaches to reduce these costs. Managed care, special contracting arrangements, and government fiat have al...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Denton TA,Diamond GA

    更新日期:1995-05-01 00:00:00