Photon pathlength determination based on spatially resolved diffuse reflectance.

Abstract:

:A method for the prediction of the average photon pathlength in turbid media has been developed. The method is based on spatially resolved diffuse reflectance with discrete source detector distances up to 2 mm. Light reflectance was simulated using a Monte Carlo technique with a one-layer model utilizing a wide range of optical properties, relevant to human skin. At a source detector separation of 2 mm, the pathlength can vary sixfold due to differences in optical properties. By applying various preprocessing and prediction techniques, the pathlength can be predicted with a root-mean-square error of approximately 5%. Estimation of the photon pathlength can be used, e.g., to remove the influence of optical properties on laser Doppler flowmetry perfusion readings, which are almost linearly related to the average photon pathlength.

journal_name

J Biomed Opt

authors

Nilsson H,Larsson M,Nilsson GE,Strömberg T

doi

10.1117/1.1482378

subject

Has Abstract

pub_date

2002-07-01 00:00:00

pages

478-85

issue

3

eissn

1083-3668

issn

1560-2281

journal_volume

7

pub_type

杂志文章
  • Changes induced by peripheral nerve injury in the morphology and nanomechanics of sensory neurons.

    abstract::Peripheral nerve injury in vivo promotes a regenerative growth in vitro characterized by an improved neurite regrowth. Knowledge of the conditioning injury effects on both morphology and mechanical properties of live sensory neurons could be instrumental to understand the cellular and molecular mechanisms leading to t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.106014

    authors: Benzina O,Szabo V,Lucas O,Saab MB,Cloitre T,Scamps F,Gergely C,Martin M

    更新日期:2013-10-01 00:00:00

  • Loss of image quality in photobleaching during microscopic imaging of fluorescent probes bound to chromatin.

    abstract::Prolonged excitation of fluorescent probes leads eventually to loss of their capacity to emit light. A decrease in the number of detected photons reduces subsequently the resolving power of a fluorescence microscope. Adverse effects of fluorescence intensity loss on the quality of microscopic images of biological spec...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2136313

    authors: Bernas T,Robinson JP,Asem EK,Rajwa B

    更新日期:2005-11-01 00:00:00

  • Perspective review on applications of optics in spinal surgery.

    abstract::Optical technologies may be applied to multiple facets of spinal surgery from diagnostics to intraoperative image guidance to therapeutics. In diagnostics, the current standard remains cross-sectional static imaging. Optical surface scanning tools may have an important role; however, significant work is required to cl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.6.060601

    authors: Guha D,Yang VXD

    更新日期:2018-06-01 00:00:00

  • Real-time brightfield, darkfield, and phase contrast imaging in a light-emitting diode array microscope.

    abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106002

    authors: Liu Z,Tian L,Liu S,Waller L

    更新日期:2014-01-01 00:00:00

  • Spatiotemporal laser speckle contrast analysis for blood flow imaging with maximized speckle contrast.

    abstract::Laser speckle contrast imaging is a technique used for imaging blood flow without scanning. Though several studies have attempted to combine spatial and temporal statistics of laser speckle images for reducing image noise as well as preserving acceptable spatiotemporal resolution, the statistical accuracy of these spa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3290804

    authors: Qiu J,Li P,Luo W,Wang J,Zhang H,Luo Q

    更新日期:2010-01-01 00:00:00

  • Innovative Troxler-free measurement of macular pigment and lens density with correction of the former for the aging lens.

    abstract::Simplified measurement of macular pigment optical density (MPOD) is important because of the ocular health benefits that are attributed to these retinal carotenoids. Here, we describe a novel instrument designed for this purpose, based on heterochromatic flicker photometry (HFP), which removes a number of difficulties...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.107003

    authors: Bone RA,Mukherjee A

    更新日期:2013-10-01 00:00:00

  • Quantitative diffuse reflectance and fluorescence spectroscopy: tool to monitor tumor physiology in vivo.

    abstract::This study demonstrates the use of optical spectroscopy for monitoring tumor oxygenation and metabolism in response to hyperoxic gas breathing. Hemoglobin saturation and redox ratio were quantified for a set of 14 and 9 mice, respectively, measured at baseline and during carbogen breathing (95% O(2), 5% CO(2)). In par...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3103586

    authors: Palmer GM,Viola RJ,Schroeder T,Yarmolenko PS,Dewhirst MW,Ramanujam N

    更新日期:2009-03-01 00:00:00

  • Preliminary evaluation of optical glucose sensing in red cell concentrations using near-infrared diffuse-reflectance spectroscopy.

    abstract::Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.017004

    authors: Suzuki Y,Maruo K,Zhang AW,Shimogaki K,Ogawa H,Hirayama F

    更新日期:2012-01-01 00:00:00

  • Intraoperative hyperspectral determination of human tissue properties.

    abstract::We address the automatic differentiation of human tissue using multispectral imaging with promising potential for automatic visualization during surgery. Currently, tissue types have to be continuously differentiated based on the surgeon's knowledge only. Further, automatic methods based on optical in vivo properties ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091409

    authors: Wisotzky EL,Uecker FC,Arens P,Dommerich S,Hilsmann A,Eisert P

    更新日期:2018-05-01 00:00:00

  • Delineation of an oral cancer lesion with swept-source optical coherence tomography.

    abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2960632

    authors: Tsai MT,Lee HC,Lu CW,Wang YM,Lee CK,Yang CC,Chiang CP

    更新日期:2008-07-01 00:00:00

  • Continuous monitoring of arthritis in animal models using optical imaging modalities.

    abstract::Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities—cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging—for continuous evaluation ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106010

    authors: Son T,Yoon HJ,Lee S,Jang WS,Jung B,Kim WU

    更新日期:2014-01-01 00:00:00

  • Identifying molecular contributors to autofluorescence of neoplastic and normal colon sections using excitation-scanning hyperspectral imaging.

    abstract::Autofluorescence, the endogenous fluorescence present in cells and tissues, has historically been considered a nuisance in biomedical imaging. Many endogenous fluorophores, specifically, collagen, elastin, nicotinamide adenine dinucleotide, and flavin adenine dinucleotide (FAD), are found throughout the human body. In...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.021207

    authors: Deal J,Mayes S,Browning C,Hill S,Rider P,Boudreaux C,Rich TC,Leavesley SJ

    更新日期:2018-12-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

    abstract::We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.3.032008

    authors: Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

    更新日期:2019-11-01 00:00:00

  • Determination of penetration profiles of topically applied substances by means of tape stripping and optical spectroscopy: UV filter substance in sunscreens.

    abstract::Penetration profiles of topically applied drugs and cosmetic products provide important information on their efficacy. The application of tape stripping in combination with UV/VIS spectroscopy is checked to determine the local position of topically applied substances inside the stratum corneum, the penetration profile...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1854683

    authors: Weigmann HJ,Jacobi U,Antoniou C,Tsikrikas GN,Wendel V,Rapp C,Gers-Barlag H,Sterry W,Lademann J

    更新日期:2005-01-01 00:00:00

  • Sensing dynamic cytoplasm refractive index changes of adherent cells with quantitative phase microscopy using incorporated microspheres as optical probes.

    abstract::The intracellular refractive index is an important parameter that describes the optical density of the cytoplasm and the concentration of the intracellular solutes. The refractive index of adherently grown cells is difficult to access. We present a method in which silica microspheres in living cells are used to determ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097001

    authors: Przibilla S,Dartmann S,Vollmer A,Ketelhut S,Greve B,von Bally G,Kemper B

    更新日期:2012-09-01 00:00:00

  • Photodynamic therapy-induced nitric oxide production in neuronal and glial cells.

    abstract::Nitric oxide (NO) has been recently demonstrated to enhance apoptosis of glial cells induced by photodynamic therapy (PDT), but to protect glial cells from PDT-induced necrosis in the crayfish stretch receptor, a simple neuroglial preparation that consists of a single mechanosensory neuron enveloped by satellite glial...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.105005

    authors: Kovaleva VD,Uzdensky AB

    更新日期:2016-10-01 00:00:00

  • Photonic approach to the selective inactivation of viruses with a near-infrared subpicosecond fiber laser.

    abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3275477

    authors: Tsen KT,Tsen SW,Fu Q,Lindsay SM,Kibler K,Jacobs B,Wu TC,Karanam B,Jagu S,Roden RB,Hung CF,Sankey OF,Ramakrishna B,Kiang JG

    更新日期:2009-11-01 00:00:00

  • Measuring hemoglobin spectra: searching for carbamino-hemoglobin.

    abstract:SIGNIFICANCE:The arterial carbon dioxide (CO2) partial pressure PaCO2 is a clinically relevant variable. However, its measurement requires arterial blood sampling or bulky and expensive transcutaneous PtcCO2 meters. While the spectrophotometric determination of hemoglobin species-such as oxy-hemoglobin (O2Hb) and deoxy...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.10.105001

    authors: Dervieux E,Bodinier Q,Uhring W,Théron M

    更新日期:2020-10-01 00:00:00

  • Spatial distribution of vastus lateralis blood flow and oxyhemoglobin saturation measured at the end of isometric quadriceps contraction by multichannel near-infrared spectroscopy.

    abstract::Muscle blood flow (MBF) and muscle oxygen saturation (SmO(2)) were measured at eight locations (four proximal, four distal) over a 4 x 8 cm(2) area of the vastus lateralis at rest and immediately after isometric, maximal quadriceps contraction using multichannel, frequency-domain, near-infrared spectroscopy. A venous ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1646417

    authors: Quaresima V,Ferrari M,Franceschini MA,Hoimes ML,Fantini S

    更新日期:2004-03-01 00:00:00

  • Selecting optimal spectral bands for improved detection of autofluorescent biomarkers in multiphoton microscopy.

    abstract:SIGNIFICANCE:In multiphoton microscopy, two-photon excited fluorescence (TPEF) spectra carry valuable information on morphological and functional biological features. For measuring these biomarkers, separation of different parts of the fluorescence spectrum into channels is typically achieved by the use of optical band...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.7.071206

    authors: Meyer BO,Stella MPJ,Holst B,Nielsen BS,Holmstrøm K,Andersen PE,Marti D

    更新日期:2020-07-01 00:00:00

  • Analyzing reflectance spectra of human skin in legal medicine.

    abstract::Our current research in the framework of an interdisciplinary project focuses on modelling the dynamics of the hemoglobin reoxygenation process in post-mortem human skin by reflectance spectrometry. The observations of reoxygenation of hemoglobin in livores after postmortem exposure to a cold environment relate the re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.017004

    authors: Belenki L,Sterzik V,Schulz K,Bohnert M

    更新日期:2013-01-01 00:00:00

  • Comparison of the sensitivity and image contrast in spontaneous Raman and coherent Stokes Raman scattering microscopy of geometry-controlled samples.

    abstract::We experimentally compare the performance and image contrast of spontaneous Raman and coherent Stokes Raman scattering microscopy. We demonstrate the differences between these techniques on a series of geometry-controlled samples that range in complexity from a point (array of tips) to one-dimensional (line grating) a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533310

    authors: Kim H,Michaels CA,Bryant GW,Stranick SJ

    更新日期:2011-02-01 00:00:00

  • Cell membrane and gold nanoparticles effects on optical immersion experiments with noncancerous and cancerous cells: finite-difference time-domain modeling.

    abstract::Pilot results on the application of the finite-difference time-domain (FDTD) approach for studying the implementation of the optical immersion technique for the visualization of single and multiple gold nanoparticles in biological cells are presented. We focus on two different scenarios considering single biological c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400239

    authors: Tanev S,Tuchin VV,Paddon P

    更新日期:2006-11-01 00:00:00

  • Monte Carlo simulation of multiphoton fluorescence microscopic imaging through inhomogeneous tissuelike turbid media.

    abstract::Image resolution and signal level in fluorescence microscopy through inhomogeneous turbid media consisting of scatterers of multiple sizes under single- (1p), two- (2p), and three-photon (3p) excitation have been investigated based on a modified Monte Carlo model. The effects of the size distribution and the concentra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1577116

    authors: Deng X,Gan X,Gu M

    更新日期:2003-07-01 00:00:00

  • Imaging corneal pathology in a transgenic mouse model using nonlinear microscopy.

    abstract::A transgenic mouse model with a Clim [co-factor of LIM (a combination of first letters of Lin-11 (C. elegans), ISL1 (rat), and Mec-3 (C. elegans) gene names) domain proteins] gene partially blocked in the epithelial compartment of its tissues is used to establish the sensitivity of intrinsic reflectance nonlinear opti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2163254

    authors: Lyubovitsky JG,Spencer JA,Krasieva TB,Andersen B,Tromberg BJ

    更新日期:2006-01-01 00:00:00

  • Hybrid method for fast Monte Carlo simulation of diffuse reflectance from a multilayered tissue model with tumor-like heterogeneities.

    abstract::We present a hybrid method that combines a multilayered scaling method and a perturbation method to speed up the Monte Carlo simulation of diffuse reflectance from a multilayered tissue model with finite-size tumor-like heterogeneities. The proposed method consists of two steps. In the first step, a set of photon traj...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.010501

    authors: Zhu C,Liu Q

    更新日期:2012-01-01 00:00:00

  • Modulated electron-multiplied fluorescence lifetime imaging microscope: all-solid-state camera for fluorescence lifetime imaging.

    abstract::We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.jbo.17.12.126020

    authors: Zhao Q,Schelen B,Schouten R,van den Oever R,Leenen R,van Kuijk H,Peters I,Polderdijk F,Bosiers J,Raspe M,Jalink K,Geert Sander de Jong J,van Geest B,Stoop K,Young IT

    更新日期:2012-12-01 00:00:00

  • Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain.

    abstract::Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.087001

    authors: Gerega A,Milej D,Weigl W,Botwicz M,Zolek N,Kacprzak M,Wierzejski W,Toczylowska B,Mayzner-Zawadzka E,Maniewski R,Liebert A

    更新日期:2012-08-01 00:00:00

  • Adaptive optics for fluorescence wide-field microscopy using spectrally independent guide star and markers.

    abstract::We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3603847

    authors: Vermeulen P,Muro E,Pons T,Loriette V,Fragola A

    更新日期:2011-07-01 00:00:00