Tracheobronchial stent insertions in the management of major airway obstruction in a patient with Hunter syndrome (type-II mucopolysaccharidosis).

Abstract:

:We report a case of a 22-year-old male with Hunter syndrome who developed progressive major airway obstruction and was treated with insertion of plastic and metallic stents, with dramatic improvement in the patient's symptomatic and functional status. To the best of our knowledge, this is the first reported case of endoluminal stents being used in the management of major airway obstruction in a patient with Hunter syndrome.

journal_name

Eur Radiol

journal_title

European radiology

authors

Davitt SM,Hatrick A,Sabharwal T,Pearce A,Gleeson M,Adam A

doi

10.1007/s003300100932

subject

Has Abstract

pub_date

2002-02-01 00:00:00

pages

458-62

issue

2

eissn

0938-7994

issn

1432-1084

journal_volume

12

pub_type

杂志文章
  • Testicular microlithiasis: clinical significance and review of the literature.

    abstract::Testicular microlithiasis (TM) is an uncommon condition characterized by calcium deposits within the seminiferous tubules. On ultrasound (US), it is seen as multiple, uniform, nonshadowing echogenic foci in the testis. Although its true prevalence in the general population is still unknown, reported prevalences range ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2014-5

    authors: Kim B,Winter TC 3rd,Ryu JA

    更新日期:2003-12-01 00:00:00

  • Iopentol (Imagopaque 300 and 350) compared with iohexol (Omnipaque 300 and 350) in cerebral and aortic arch angiography. A clinical trial assessing adverse events and diagnostic information.

    abstract::The safety of the non-ionic contrast medium iopentol (Imagopaque, Nycomed Imaging AS, Oslo, Norway) when used in cerebral angiography and aortic arch angiography, was the focus of this investigation. Overall quality of visualization and changes in heart rate and blood pressure were, however, also assessed. In total, 3...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/pl00006884

    authors: Ericsson K,Bjartveit K

    更新日期:1997-01-01 00:00:00

  • Growing Region Segmentation Software (GRES) for quantitative magnetic resonance imaging of multiple sclerosis: intra- and inter-observer agreement variability: a comparison with manual contouring method.

    abstract::Lesion area measurement in multiple sclerosis (MS) is one of the key points in evaluating the natural history and in monitoring the efficacy of treatments. This study was performed to check the intra- and inter-observer agreement variability of a locally developed Growing Region Segmentation Software (GRES), comparing...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300100978

    authors: Parodi RC,Sardanelli F,Renzetti P,Rosso E,Losacco C,Ferrari A,Levrero F,Pilot A,Inglese M,Mancardi GL

    更新日期:2002-04-01 00:00:00

  • Ultrasound guidance to perform intra-articular injection of gadolinium-based contrast material for magnetic resonance arthrography as an alternative to fluoroscopy: the time is now.

    abstract:UNLABELLED:Magnetic resonance (MR) imaging has been definitively established as the reference standard in the evaluation of joints in the body. Similarly, magnetic resonance arthrography has emerged as a technique that has been proven to increase significantly the diagnostic performance if compared with conventional MR...

    journal_title:European radiology

    pub_type: 社论

    doi:10.1007/s00330-015-3945-3

    authors: Messina C,Banfi G,Aliprandi A,Mauri G,Secchi F,Sardanelli F,Sconfienza LM

    更新日期:2016-05-01 00:00:00

  • Correction to: T1 and T2 MR fingerprinting measurements of prostate cancer and prostatitis correlate with deep learning-derived estimates of epithelium, lumen, and stromal composition on corresponding whole mount histopathology.

    abstract::The original version of this article, published on 02 September 2020, unfortunately contained a mistake. ...

    journal_title:European radiology

    pub_type: 已发布勘误

    doi:10.1007/s00330-020-07285-8

    authors: Shiradkar R,Panda A,Leo P,Janowczyk A,Farre X,Janaki N,Li L,Pahwa S,Mahran A,Buzzy C,Fu P,Elliott R,MacLennan G,Ponsky L,Gulani V,Madabhushi A

    更新日期:2020-09-18 00:00:00

  • An isolated fourth ventricle in neurosarcoidosis: MRI findings.

    abstract::We report on an isolated enlargement of the fourth ventricle in a patient with neurosarcoidosis which developed 3 years after the insertion of a ventriculo-atrial shunt. Repeated MRI images were obtained in a patient with known neurosarcoidosis between 1995 and 2000. Imaging findings were correlated to the medical cou...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1369-3

    authors: Hesselmann V,Wedekind C,Terstegge K,Schulte O,Voges J,Krug B,Lackner K

    更新日期:2002-12-01 00:00:00

  • Everyman's prostate phantom: kiwi-fruit substitute for human prostates at magnetic resonance imaging, diffusion-weighted imaging and magnetic resonance spectroscopy.

    abstract:OBJECTIVES:To apply an easy-to-assemble phantom substitute for human prostates in T2-weighted magnetic resonance imaging (T2WI), diffusion-weighted imaging (DWI) and 3D magnetic resonance spectroscopy (MRS). METHODS:Kiwi fruit were fixed with gel hot and cold compress packs on two plastic nursery pots, separated by a ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4706-7

    authors: Mueller-Lisse UG,Murer S,Mueller-Lisse UL,Kuhn M,Scheidler J,Scherr M

    更新日期:2017-08-01 00:00:00

  • Management of patient dose and image noise in routine pediatric CT abdominal examinations.

    abstract::The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were the...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-003-2206-z

    authors: Verdun FR,Lepori D,Monnin P,Valley JF,Schnyder P,Gudinchet F

    更新日期:2004-05-01 00:00:00

  • Correlation between quantitative assessment of contrast enhancement in contrast-enhanced spectral mammography (CESM) and histopathology-preliminary results.

    abstract:OBJECTIVES:Contrast-enhanced spectral mammography (CESM) is a novel method for breast cancer detection. The aim of this study is to check if there is a possibility of quantitative assessment of contrast enhancement in CESM and if there is any correlation between quantitative assessment of contrast enhancement in CESM a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06232-6

    authors: Rudnicki W,Heinze S,Niemiec J,Kojs Z,Sas-Korczynska B,Hendrick E,Luczynska E

    更新日期:2019-11-01 00:00:00

  • 3D motion adapted gating (3D MAG): a new navigator technique for accelerated acquisition of free breathing navigator gated 3D coronary MR-angiography.

    abstract::This study aimed to evaluate the influence of a new navigator technique (3D MAG) on navigator efficiency, total acquisition time, image quality and diagnostic accuracy. Fifty-six patients with suspected coronary artery disease underwent free breathing navigator gated coronary MRA (Intera, Philips Medical Systems, 1.5 ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-2731-z

    authors: Hackenbroch M,Nehrke K,Gieseke J,Meyer C,Tiemann K,Litt H,Dewald O,Naehle CP,Schild H,Sommer T

    更新日期:2005-08-01 00:00:00

  • Correction to: Prevalence and prognostic value of late gadolinium enhancement on CMR in aortic stenosis: meta-analysis.

    abstract::The original version of this article, published on 12 August 2019, unfortunately contained a mistake. The funding note was incorrect; the correct funding note is given below. ...

    journal_title:European radiology

    pub_type: 已发布勘误

    doi:10.1007/s00330-020-06818-5

    authors: Balciunaite G,Skorniakov V,Rimkus A,Zaremba T,Palionis D,Valeviciene N,Aidietis A,Serpytis P,Rucinskas K,Sogaard P,Glaveckaite S

    更新日期:2020-09-01 00:00:00

  • Quantification of bronchial dimensions at MDCT using dedicated software.

    abstract::This study aimed to assess the feasibility of quantification of bronchial dimensions at MDCT using dedicated software (BronCare). We evaluated the reliability of the software to segment the airways and defined criteria ensuring accurate measurements. BronCare was applied on two successive examinations in 10 mild asthm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-006-0496-7

    authors: Brillet PY,Fetita CI,Beigelman-Aubry C,Saragaglia A,Perchet D,Preteux F,Grenier PA

    更新日期:2007-06-01 00:00:00

  • ACCURATUM: improved calcium volume scoring using a mesh-based algorithm--a phantom study.

    abstract::To overcome the limitations of the classical volume scoring method for quantifying coronary calcifications, including accuracy, variability between examinations, and dependency on plaque density and acquisition parameters, a mesh-based volume measurement method has been developed. It was evaluated and compared with th...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1181-9

    authors: Saur SC,Alkadhi H,Desbiolles L,Székely G,Cattin PC

    更新日期:2009-03-01 00:00:00

  • Presinusoidal portal hypertension does not affect hepatic artery resistance index.

    abstract::We aimed to determine the mean hepatic artery resistance index (RI) in presinusoidal portal hypertension and to compare the values with those in sinusoidal portal hypertension. The hepatic artery RIs of 11 patients with presinusoidal portal hypertension, 12 patients with sinusoidal portal hypertension and 16 healthy s...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050806

    authors: Erden A,Altuntaş B,Olçer T,Cumhur T

    更新日期:1999-01-01 00:00:00

  • Dual-Phase Dual-Energy CT in Patients Treated with Erlotinib for Advanced Non-Small Cell Lung Cancer: Possible Benefits of Iodine Quantification in Response Assessment.

    abstract:OBJECTIVES:To investigate the relationship of dual-phase dual-energy CT (DE-CT) and tumour size in the evaluation of the response to anti-EGFR therapy in patients with advanced non-small cell lung cancer (NSCLC). METHODS:Dual-phase DE-CT was performed in 31 patients with NSCLC before the onset of anti-EGFR (erlotinib)...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-4092-6

    authors: Baxa J,Matouskova T,Krakorova G,Schmidt B,Flohr T,Sedlmair M,Bejcek J,Ferda J

    更新日期:2016-08-01 00:00:00

  • Larger corpus callosum and reduced orbitofrontal cortex homotopic connectivity in codeine cough syrup-dependent male adolescents and young adults.

    abstract:OBJECTIVES:To characterize interhemispheric functional and anatomical connectivity and their relationships with impulsive behaviour in codeine-containing cough syrup (CCS)-dependent male adolescents and young adults. METHODS:We compared volumes of corpus callosum (CC) and its five subregion and voxel-mirrored homotopi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4465-5

    authors: Qiu YW,Lv XF,Jiang GH,Su HH,Ma XF,Tian JZ,Zhuo FZ

    更新日期:2017-03-01 00:00:00

  • Prophylactic balloon occlusion of internal iliac arteries, common iliac arteries and infrarenal abdominal aorta in pregnancies complicated by placenta accreta: a retrospective cohort study.

    abstract:OBJECTIVES:To evaluate the efficacy of prophylactic balloon occlusion (PBO), and to compare haemostatic effects and perioperative outcomes of PBO of the internal iliac arteries (IIA), common iliac arteries (CIA) and infrarenal abdominal aorta (IAA) in patients with placenta accreta. METHODS:One hundred and ninety-nine...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5527-7

    authors: Li K,Zou Y,Sun J,Wen H

    更新日期:2018-12-01 00:00:00

  • MR and CT findings in a case of hibernoma of the thigh extending into the pelvis.

    abstract::Review of the literature shows no report of hibernoma of the thigh extending into the pelvis. Herein we report a case of hibernoma which appeared on CT and MR as a well-defined pelvic mass with contrast enhancement extending through the obturator foramen into the thigh. Fat was demonstrated by CT, whereas MR, using mu...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300050419

    authors: Mugel T,Ghossain MA,Guinet C,Buy J,Bethoux J,Texier P,Vadrot D

    更新日期:1998-01-01 00:00:00

  • Non-tuberculous iliopsoas abscess due to perforated diverticulitis presenting with intestinal obstruction and a groin mass.

    abstract::Psoas abscess is an uncommon condition and, contrary to traditional teaching, tends to be of non-tuberculous aetiology in developed countries. Diagnosis can be delayed since presenting features are non-specific and in many instances misleading, necessitating a high degree of clinical suspicion and early resort to cros...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000661

    authors: Kaul V,Jackson M,Farrugia M

    更新日期:2001-01-01 00:00:00

  • High b-value diffusion-weighted MRI for detecting gallbladder carcinoma: preliminary study and results.

    abstract::The aim of this preliminary study was to retrospectively evaluate the usefulness of high b-value diffusion-weighted MR imaging (DWI) in the detection of gallbladder carcinoma. Fifteen patients with gallbladder carcinoma and 14 other patients were included in this study. All patients and subjects underwent DWI, and ima...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1322-9

    authors: Sugita R,Yamazaki T,Furuta A,Itoh K,Fujita N,Takahashi S

    更新日期:2009-07-01 00:00:00

  • Soft tissue Burkitt's lymphoma: radiological findings.

    abstract::An unusual case is reported of a soft tissue mass in the lower extremity, without bone involvement, in an 85-year-old woman; the histopathological diagnosis was Burkitt's lymphoma. Pertinent clinical history, histological examination, and imaging procedures allowed early diagnosis. To our knowledge, the radiological f...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050605

    authors: García-Barredo R,Fernández Echevarría MA,del Riego M,Canga A

    更新日期:1998-01-01 00:00:00

  • Small peripheral lung carcinomas with five-year post-surgical follow-up: assessment by semi-automated volumetric measurement of tumour size, CT value and growth rate on TSCT.

    abstract:OBJECTIVES:To retrospectively assess the utility of semi-automated measurements by stratification of CT values of tumour size, CT value and doubling time (DT) using thin-section computed tomography (CT) images. The post-surgical outcomes of favourable and problematic tumours (more advanced p stage than IA, post-surgica...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-011-2241-0

    authors: Sone S,Hanaoka T,Ogata H,Takayama F,Watanabe T,Haniuda M,Kaneko K,Kondo R,Yoshida K,Honda T

    更新日期:2012-01-01 00:00:00

  • Diagnostic imaging of tumors of the hand and wrist.

    abstract::Tumors of the hand and wrist most commonly result from dystrophic lesions and hamartomas. Neoplastic lesions are rare. Imaging modalities are required for their detection and accurate location, careful assessment of the internal structure and borders, evaluation of the relation with surrounding tendons, nerves, and ve...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300000751

    authors: Garcia J,Bianchi S

    更新日期:2001-01-01 00:00:00

  • Perirenal textiloma: MR and serial CT appearance.

    abstract::We describe changes in imaging features of a textiloma (retained surgical sponge or retained foreign body) left in the renal fossa after exploratory renal surgery. One year after the initial surgery, the MR aspect of the textiloma was not specific, with a homogeneous low signal intensity on T1-weighted images. Serial ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050338

    authors: Bellin M,Hornoy B,Richard F,Davy-Miallou C,Fadel Y,Zaim S,Challier E,Grenier P

    更新日期:1998-01-01 00:00:00

  • Seminal vesicle invasion in prostate cancer: prediction with combined T2-weighted and diffusion-weighted MR imaging.

    abstract::The aim of this study was to evaluate the usefulness of diffusion-weighted imaging (DWI) in detecting seminal vesicle invasion (SVI). A total of 283 patients underwent conventional MRI and DWI before prostate cancer surgery. The apparent diffusion coefficient (ADC) values of all PCa foci, SVI and seminal vesicle were ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1428-0

    authors: Ren J,Huan Y,Wang H,Ge Y,Chang Y,Yin H,Sun L

    更新日期:2009-10-01 00:00:00

  • Assessment of myocardial viability by MR imaging.

    abstract::Diagnosis of myocardial viability after infarction focuses on the prediction of functional improvement of dysfunctional myocardium after revascularization therapy. Magnetic resonance imaging provides different approaches for the detection of myocardial viability. Measurement of end-diastolic wall thickness is easy to ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1701-y

    authors: Sandstede JJ

    更新日期:2003-01-01 00:00:00

  • Bone marrow edema around the hip in non-traumatic pain: dual-energy CT vs MRI.

    abstract:OBJECTIVES:To evaluate the diagnostic accuracy of dual-energy computed tomography (DECT) in identifying bone marrow edema (BME) around the hip joint in non-traumatic patients. METHODS:This prospective IRB-approved study was conducted between January 2019 and October 2019 and included 59 consecutive patients (18 males,...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-06775-z

    authors: Foti G,Faccioli N,Silva R,Oliboni E,Zorzi C,Carbognin G

    更新日期:2020-07-01 00:00:00

  • Non-traumatic vascular emergencies: imaging and intervention in acute arterial conditions.

    abstract::Methods of imaging and intervention in acute non-traumatic vascular arterial conditions has changed substantially during recent years. Computed tomography, MRI angiography and, more recently, intravascular ultrasonography (IVUS) have replaced to a large extent conventional diagnostic angiography. An increasing number ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-002-1526-8

    authors: Cwikiel W,Midia M,Williams D

    更新日期:2002-11-01 00:00:00

  • A new technique for noise reduction at coronary CT angiography with multi-phase data-averaging and non-rigid image registration.

    abstract:OBJECTIVES:To investigate the feasibility of a newly developed noise reduction technique at coronary CT angiography (CTA) that uses multi-phase data-averaging and non-rigid image registration. METHODS:Sixty-five patients underwent coronary CTA with prospective ECG-triggering. The range of the phase window was set at 7...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3381-9

    authors: Tatsugami F,Higaki T,Nakamura Y,Yamagami T,Date S,Fujioka C,Kiguchi M,Kihara Y,Awai K

    更新日期:2015-01-01 00:00:00

  • Comparison of three multichannel transmit/receive radiofrequency coil configurations for anatomic and functional cardiac MRI at 7.0T: implications for clinical imaging.

    abstract:OBJECTIVES:To implement, examine, and compare three multichannel transmit/receive coil configurations for cardiovascular MR (CMR) at 7T. METHODS:Three radiofrequency transmit-receive (TX/RX) coils with 4-, 8-, and 16-coil elements were used. Ten healthy volunteers (seven males, age 28 ± 4 years) underwent CMR at 7T. F...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-012-2487-1

    authors: Winter L,Kellman P,Renz W,Gräßl A,Hezel F,Thalhammer C,von Knobelsdorff-Brenkenhoff F,Tkachenko V,Schulz-Menger J,Niendorf T

    更新日期:2012-10-01 00:00:00