Cross-sectional imaging of primary osseous hemangiopericytoma.

Abstract:

:The aim of this study was to assess cross-sectional imaging features and the value of CT and MRI in primary hemangiopericytoma of bone. In five patients with histologically proven primary osseous hemangiopericytoma CT and MR scans were evaluated retrospectively. Both CT and MRI were available in four patients each. In three patients both imaging techniques were available. On CT primary hemangiopericytoma of bone presents as an expansive lytic lesion with bone destruction and inhomogeneous contrast enhancement. Magnetic resonance imaging depicts osseous hemangiopericytoma as hyperintense lesion on T2-weighted images with intermediate signal intensity on T1-weighted images. Curvilinear tubular structures of signal void in the tumor matrix on T1-weighted images and corresponding hyperintense structures on T2-weighted and on fat-suppressed short tau inversion recovery images were present in three patients. Although cross-sectional imaging findings are non-specific, they add to the diagnosis and provide valuable information about the extent of bone destruction and local tumor spread in patients with primary osseous hemangiopericytoma. While CT demonstrates the extent of bone destruction best, MRI better visualizes medullary and soft tissue extension of the tumor. Curvilinear signal abnormalities support the diagnosis of hemangiopericytoma of bone. This imaging pattern is best visualized on fat-suppressed or contrast enhanced T1-weighted MR images.

journal_name

Eur Radiol

journal_title

European radiology

authors

Mahnken AH,Tacke J,Wolter P,Büttner R,Haller JS,Günther RW

doi

10.1007/s003300101027

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

85-9

issue

1

eissn

0938-7994

issn

1432-1084

journal_volume

12

pub_type

杂志文章
  • Quantification of blood flow.

    abstract::Traditionally, Doppler ultrasound has been used to estimate blood flow as the mean velocity multiplied by the vessel area, but this is subject to significant errors and may be difficult to perform accurately. Microbubbles, developed as contrast agents for ultrasound, were initially envisaged as useful for increasing t...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s003300100985

    authors: Cosgrove D,Eckersley R,Blomley M,Harvey C

    更新日期:2001-01-01 00:00:00

  • The clinical value of a negative multi-detector computed tomographic angiography in patients suspected of coronary artery disease: A meta-analysis.

    abstract::The aim of this meta-analysis was to calculate the sensitivity of contrast-enhanced multi-detector computed tomography (MDCT) compared with coronary angiography (CAG) in incident patients suspected of coronary artery disease (CAD). We searched PubMed, Embase, bibliographies of original papers and reviews to identify o...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-006-0312-4

    authors: van der Zaag-Loonen HJ,Dikkers R,de Bock GH,Oudkerk M

    更新日期:2006-12-01 00:00:00

  • The effect of tube voltage combination on image artefact and radiation dose in dual-source dual-energy CT: comparison between conventional 80/140 kV and 80/150 kV plus tin filter for gout protocol.

    abstract:OBJECTIVES:In dual-source CT, dual-energy (DE) performance is affected by various X-ray tube voltage combinations with and without tin filter (Sn). The purpose of this study was to assess the utility of the 80/150 Sn kV voltage combination in terms of image artefact and radiation dose for DECT gout protocol, compared w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5622-9

    authors: Jeon JY,Lee SW,Jeong YM,Baek HJ

    更新日期:2019-03-01 00:00:00

  • Comparison of hybrid 68Ga-PSMA-PET/CT and 99mTc-DPD-SPECT/CT for the detection of bone metastases in prostate cancer patients: Additional value of morphologic information from low dose CT.

    abstract:PURPOSE:This study compared 68Gallium-prostate-specific-membrane-antigen based Positron-emission-tomography (68Ga-PSMA-PET) and 99metastabletechnetium-3,3-diphospho-1,2-propanedicarbonacid (99mTc-DPD-SPECT) in performing skeletal staging in prostate cancer (PC) patients and evaluated the additional value of the informa...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4994-6

    authors: Janssen JC,Meißner S,Woythal N,Prasad V,Brenner W,Diederichs G,Hamm B,Makowski MR

    更新日期:2018-02-01 00:00:00

  • Scrotal arteriovenous malformation and its preoperative embolization.

    abstract::Arteriovenous malformations of the scrotum are extremely rare. A case of scrotal arteriovenous malformation and its preoperative embolization in a child is presented. ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050686

    authors: Konus OL,Ilgit ET,Yücel C,Ozbek E,Onal B

    更新日期:1999-01-01 00:00:00

  • Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation.

    abstract:OBJECTIVE:The aim of the study was to assess the performance and diagnostic value of a dual energy CT approach to reduce metal artefacts in subjects with metallic implants. METHODS:31 patients were examined in the area of their metallic implants using a dual energy CT protocol (filtered 140 kVp and 100 kVp spectrum, t...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2062-1

    authors: Bamberg F,Dierks A,Nikolaou K,Reiser MF,Becker CR,Johnson TR

    更新日期:2011-07-01 00:00:00

  • Detection of Active Sacroiliitis with Ankylosing Spondylitis through Intravoxel Incoherent Motion Diffusion-Weighted MR Imaging.

    abstract:OBJECTIVE:To confirm feasibility and assess intravoxel incoherent motion (IVIM) to differentiate active sacroiliitis and ankylosing spondylitis.. METHODS:Forty-one patients were divided into two groups, an active group (n = 20) and a chronic group (n = 21), according to the Bath Ankylosing Spondylitis (AS) Disease Act...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3634-2

    authors: Zhao YH,Li SL,Liu ZY,Chen X,Zhao XC,Hu SY,Liu ZH,M S YJ,Chan Q,Liang CH

    更新日期:2015-09-01 00:00:00

  • T2 mapping of the meniscus is a biomarker for early osteoarthritis.

    abstract:PURPOSE:To evaluate in vivo T2 mapping as quantitative, imaging-based biomarker for meniscal degeneration in humans, by studying the correlation between T2 relaxation time and degree of histological degeneration as reference standard. METHODS:In this prospective validation study, 13 menisci from seven patients with ra...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06091-1

    authors: Eijgenraam SM,Bovendeert FAT,Verschueren J,van Tiel J,Bastiaansen-Jenniskens YM,Wesdorp MA,Nasserinejad K,Meuffels DE,Guenoun J,Klein S,Reijman M,Oei EHG

    更新日期:2019-10-01 00:00:00

  • Significance of hyperechoic marks observed during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules.

    abstract:OBJECTIVE:To examine the association between the appearance of hyperechoic marks (HEMs) during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules and nodule shrinkage at 6 months. METHODS:One hundred and thirty-six patients who underwent HIFU for benign thyroid nodule were analysed. An indepen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5207-z

    authors: Lang BHH,Woo YC,Chiu KW

    更新日期:2018-06-01 00:00:00

  • Infrahyoid spread of deep neck abscess: anatomical consideration.

    abstract::The aim of this study was to determine the pathway of infrahyoid extension of the oropharyngeal abscess considering the anatomy of the fascial spaces by cross-sectional imaging. CT scans and MR images were retrospectively reviewed in ten patients with known infrahyoid extension of oropharyngeal abscesses (eight with a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050495

    authors: Ojiri H,Tada S,Ujita M,Ariizumi M,Ishii C,Mizunuma K,Fukuda K

    更新日期:1998-01-01 00:00:00

  • Whole-tumour diffusion kurtosis MR imaging histogram analysis of rectal adenocarcinoma: Correlation with clinical pathologic prognostic factors.

    abstract:OBJECTIVE:To investigate potential relationships between diffusion kurtosis imaging (DKI)-derived parameters using whole-tumour volume histogram analysis and clinicopathological prognostic factors in patients with rectal adenocarcinoma. MATERIAL AND METHODS:79 consecutive patients who underwent MRI examination with re...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5094-3

    authors: Cui Y,Yang X,Du X,Zhuo Z,Xin L,Cheng X

    更新日期:2018-04-01 00:00:00

  • Congenital absence of the internal carotid artery and the basilar artery with persistent trigeminal artery associated with coarctation of the aorta.

    abstract::We report a case of congenital absence of the cervical and petrous part of the left internal carotid artery, the middle and proximal part of the basilar artery, and the V4 segment of the left vertebral artery associated with a left persistent trigeminal artery and a coarctation of the aorta. The left cerebral vessels ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000500

    authors: Jaeger HJ,Mehring UM,Gissler HM,Mathias KD

    更新日期:2000-01-01 00:00:00

  • Clinical indications for image guided interventional procedures in the musculoskeletal system: a Delphi-based consensus paper from the European Society of Musculoskeletal Radiology (ESSR)-part III, nerves of the upper limb.

    abstract:BACKGROUND:Image-guided interventional procedures of the nerves are commonly performed by physicians from different medical specialties, although there is a lack of clinical indications for these types of procedures. This Delphi-based consensus provided a list of indications on image-guided interventional procedures fo...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06479-z

    authors: Sconfienza LM,Adriaensen M,Albano D,Allen G,Aparisi Gómez MP,Bazzocchi A,Beggs I,Bignotti B,Chianca V,Corazza A,Dalili D,De Dea M,Del Cura JL,Di Pietto F,Drakonaki E,Facal de Castro F,Filippiadis D,Gielen J,Gitto S,

    更新日期:2020-03-01 00:00:00

  • Focal nodular hyperplasia of the liver on ferumoxides-enhanced MR imaging: features on conventional spin-echo, fast spin-echo and gradient-echo pulse sequences.

    abstract::The aim of this study was to assess the efficacy of a superparamagnetic iron oxide, ferumoxides, in the detection and characterization of focal nodular hyperplasia (FNH) on MR conventional spin-echo (SE), fast spin-echo (FSE) and gradient-echo (GRE) images. Fourteen adults with 27 FNHs were evaluated at 1.5 T before a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050879

    authors: Precetti-Morel S,Bellin MF,Ghebontni L,Zaïm S,Opolon P,Poynard T,Mathurin P,Cluzel P

    更新日期:1999-01-01 00:00:00

  • T2 black lesions on routine knee MRI: differential considerations.

    abstract::The majority of abnormal findings or lesions on T2-weighted fast spin-echo (FSE) magnetic resonance imaging (MRI) are hyperintense due to increased perfusion or fluid content, such as infections, tumours or synovitis. Hypointense lesions on T2-weighted images (both fat-suppressed and non-fat-suppressed) are less commo...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-015-4027-2

    authors: Wadhwa V,Cho G,Moore D,Pezeshk P,Coyner K,Chhabra A

    更新日期:2016-07-01 00:00:00

  • Clinical feasibility of a myocardial signal intensity threshold-based semi-automated cardiac magnetic resonance segmentation method.

    abstract:OBJECTIVES:To assess the accuracy and efficiency of a threshold-based, semi-automated cardiac MRI segmentation algorithm in comparison with conventional contour-based segmentation and aortic flow measurements. METHODS:Short-axis cine images of 148 patients (55 ± 18 years, 81 men) were used to evaluate left ventricular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3952-4

    authors: Varga-Szemes A,Muscogiuri G,Schoepf UJ,Wichmann JL,Suranyi P,De Cecco CN,Cannaò PM,Renker M,Mangold S,Fox MA,Ruzsics B

    更新日期:2016-05-01 00:00:00

  • Acute cerebral stroke imaging and brain perfusion with the use of high-concentration contrast media.

    abstract::Acute cerebral stroke remains a major cause of death among adults and the emergence of new therapies has created a need for early and rapid imaging at a time when conventional CT is either normal or demonstrates subtle abnormalities that are easy to misinterpret. Perfusion CT uses the temporal changes in cerebral and ...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-003-2104-4

    authors: Miles KA

    更新日期:2003-12-01 00:00:00

  • Acute idiopathic scrotal edema: ultrasonographic findings at an emergency unit.

    abstract::We evaluated the US findings in acute idiopathic scrotal edema (AISE) in order to identify diagnostic features that may help to avoid unnecessary surgical intervention. We investigated 12 boys with AISE diagnosed according to the clinical course and US findings. We assessed the thickness, compressibility, and vascular...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1356-z

    authors: Lee A,Park SJ,Lee HK,Hong HS,Lee BH,Kim DH

    更新日期:2009-08-01 00:00:00

  • Does CT have an additional diagnostic value over ultrasound in the evaluation of acute inflammatory neck masses in children?

    abstract:OBJECTIVES:We assessed the additional value of contrast-enhanced CT versus US for evaluation of acute cervical inflammatory masses and choosing treatment strategy. METHODS:We retrospectively reviewed 210 files of paediatric patients admitted with an acute inflammatory neck mass from 2005 to 2008 (M:F = 108:102, mean a...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-009-1563-7

    authors: Rozovsky K,Hiller N,Koplewitz BZ,Simanovsky N

    更新日期:2010-02-01 00:00:00

  • Renal trauma in occult ureteropelvic junction obstruction: CT findings.

    abstract::The aim of this study was to present CT findings of occult ureteropelvic junction obstruction in patients with renal trauma and to describe the clinical signs and singular CT features that are characteristically observed with trauma and are relevant to management of these patients. We retrospectively reviewed 82 helic...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050718

    authors: Sebastià MC,Rodriguez-Dobao M,Quiroga S,Pallisa E,Martinez-Rodriguez M,Alvarez-Castells A

    更新日期:1999-01-01 00:00:00

  • Applicability and accuracy of pretest probability calculations implemented in the NICE clinical guideline for decision making about imaging in patients with chest pain of recent onset.

    abstract:OBJECTIVES:To analyse the implementation, applicability and accuracy of the pretest probability calculation provided by NICE clinical guideline 95 for decision making about imaging in patients with chest pain of recent onset. METHODS:The definitions for pretest probability calculation in the original Duke clinical sco...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5322-5

    authors: Roehle R,Wieske V,Schuetz GM,Gueret P,Andreini D,Meijboom WB,Pontone G,Garcia M,Alkadhi H,Honoris L,Hausleiter J,Bettencourt N,Zimmermann E,Leschka S,Gerber B,Rochitte C,Schoepf UJ,Shabestari AA,Nørgaard B,Sato A,

    更新日期:2018-09-01 00:00:00

  • Use of dual-energy CT for renal mass assessment.

    abstract::Although dual-energy CT (DECT) may prove useful in a variety of abdominal imaging tasks, renal mass evaluation represents the area where this technology can be most impactful in abdominal imaging compared to routinely performed contrast-enhanced-only single-energy CT exams. DECT post-processing techniques, such as cre...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-07426-z

    authors: Thiravit S,Brunnquell C,Cai LM,Flemon M,Mileto A

    更新日期:2020-11-18 00:00:00

  • Three-dimensional cholangio-spiral CT demonstration of a post-traumatic bile leak in a child.

    abstract::Bilioma is a rare complication of traumatic liver injury, and the precise site of bile leak is often difficult to demonstrate with a non-invasive technique. We report a case of post-traumatic bile leak in a 15-year-old girl in whom spiral CT after intravenous cholangiography allowed excellent preoperative demonstratio...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050637

    authors: Wicky S,Gudinchet F,Barghouth G,Schnyder P

    更新日期:1999-01-01 00:00:00

  • Functional diagnosis of placenta accreta by intravoxel incoherent motion model diffusion-weighted imaging.

    abstract:OBJECTIVES:To investigate the diagnostic value of intravoxel incoherent motion (IVIM) DWI for placenta accreta by comparing diffusion and perfusion characteristics of placentas with accreta lesions (APs) with those of normal placentas (NPs). METHODS:Twenty-five pregnant women with AP and 24 with NP underwent 3-T magne...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07200-1

    authors: Bao Y,Pang Y,Sun Z,Li Q,Tang D,Xia L

    更新日期:2021-02-01 00:00:00

  • CT colonography polyp matching: differences between experienced readers.

    abstract::The purpose of this study was to investigate if experienced readers differ when matching polyps shown by both CT colonography (CTC) and optical colonoscopy (OC) and to explore the reasons for discrepancy. Twenty-eight CTC cases with corresponding OC were presented to eight experienced CTC readers. Cases represented a ...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-009-1328-3

    authors: Liedenbaum MH,de Vries AH,Halligan S,Bossuyt PM,Dachman AH,Dekker E,Florie J,Gryspeerdt SS,Jensch S,Johnson CD,Laghi A,Taylor SA,Stoker J

    更新日期:2009-07-01 00:00:00

  • Effectiveness of a three-dimensional dual gradient echo two-point Dixon technique for the characterization of adrenal lesions at 3 Tesla.

    abstract:OBJECTIVE:To compare the sensitivity, specificity, and diagnostic accuracy of fat-only datasets reconstructed using a two-point Dixon technique, with corresponding opposed-phase (OP) and in-phase (IP) datasets for characterization of adrenal lesions at 3 Tesla (T). METHODS:Fifty-nine patients (21 male, 38 female) with...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-011-2244-x

    authors: Marin D,Dale BM,Bashir MR,Ziemlewicz TJ,Ringe KI,Boll DT,Merkle EM

    更新日期:2012-01-01 00:00:00

  • Hepatic cysts treated with percutaneous ethanol sclerotherapy: time to extend the indications to haemorrhagic cysts and polycystic liver disease.

    abstract:OBJECTIVES:To describe the long-term clinical and morphological outcome of symptomatic hepatic cysts treated with percutaneous ethanol sclerotherapy (PES). METHODS:From December 2003 to September 2011, all patients with hepatic cysts undergoing PES with a follow-up after 12 months were included. Evolution of the volum...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3117-x

    authors: Benzimra J,Ronot M,Fuks D,Abdel-Rehim M,Sibert A,Farges O,Vilgrain V

    更新日期:2014-05-01 00:00:00

  • Dose reduction in dynamic perfusion CT of the brain: effects of the scan frequency on measurements of cerebral blood flow, cerebral blood volume, and mean transit time.

    abstract::The influence of the frequency of computed tomography (CT) image acquisition on the diagnostic quality of dynamic perfusion CT (PCT) studies of the brain was investigated. Eight patients with clinically suspected acute ischemia of one hemisphere underwent PCT, performed on average 3.4 h after the onset of symptoms. Si...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1083-x

    authors: Wiesmann M,Berg S,Bohner G,Klingebiel R,Schöpf V,Stoeckelhuber BM,Yousry I,Linn J,Missler U

    更新日期:2008-12-01 00:00:00

  • Local staging of endometrial carcinoma: role of multidetector CT.

    abstract::The purpose was to evaluate the accuracy of multidetector CT (MDCT) on a 16-row CT scanner in local staging of endometrial carcinoma and more specifically in the assessment of the depth of myometrial invasion and presence of cervical infiltration. This prospective study includes 21 women with newly diagnosed endometri...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-007-0839-z

    authors: Tsili AC,Tsampoulas C,Dalkalitsis N,Stefanou D,Paraskevaidis E,Efremidis SC

    更新日期:2008-05-01 00:00:00

  • Thyroid nodules with initially non-diagnostic, fine-needle aspiration results: comparison of core-needle biopsy and repeated fine-needle aspiration.

    abstract:OBJECTIVE:To evaluate the role of core-needle biopsy (CNB) by comparing the results of CNB and repeated fine-needle aspiration (FNA) for thyroid nodules with initially non-diagnostic FNA results. METHODS:From October 2008 to December 2011, 360 nodules - 180 consecutive repeated FNAs and 180 consecutive CNBs -- from 36...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-014-3325-4

    authors: Choi SH,Baek JH,Lee JH,Choi YJ,Hong MJ,Song DE,Kim JK,Yoon JH,Kim WB

    更新日期:2014-11-01 00:00:00