Abstract:
:Although spatial resolution of current MR angiography is excellent, temporal resolution has remained unsatisfactory. We evaluated clinical applicability of 2D thick-slice, contrast-enhanced subtraction MR angiography (2D-MR digital subtraction angiography) with sub-second temporal resolution in cerebrovascular occlusive diseases. Twenty-five patients with cerebrovascular occlusive diseases (8 moyamoya diseases, 10 proximal internal carotid occlusions, and 2 sinus thromboses ) were studied with a 1.5-T MR unit. The MR digital subtraction angiography (MRDSA) was performed per 0.97 s continuously just after a bolus injection of 15 ml of gadolinium chelates up to 40 s in sagittal (covering hemisphere) or coronal planes. Subtraction images were generated at a workstation. We evaluated imaging quality and hemodynamic information of MRDSA in comparison with those of routine MR imaging, non-contrast MR angiography, and X-ray intra-arterial DSA. Major cerebral arteries, all of the venous sinuses, and most tributaries were clearly visualized with 2D MRDSA. Also, pure arterial phases were obtained in all cases. The MRDSA technique demonstrated prolonged circulation in sinus thromboses, distal patent lumen of proximal occlusion, and some collateral circulation. Such hemodynamic information was comparable to that of intra-arterial DSA. Two-dimensional thick-slice MRDSA with high temporal resolution has a unique ability to demonstrate cerebral hemodynamics equivalent to that of intra-arterial DSA and may play an important role for evaluation of cerebrovascular occlusive diseases.
journal_name
Eur Radioljournal_title
European radiologyauthors
Aoki S,Yoshikawa T,Hori M,Ishigame K,Nambu A,Kumagai H,Araki Tdoi
10.1007/s003300000584subject
Has Abstractpub_date
2000-01-01 00:00:00pages
1858-64issue
12eissn
0938-7994issn
1432-1084journal_volume
10pub_type
杂志文章abstract:OBJECTIVE:Coronary angiography using multidetector computed tomography (MDCT) allows non-invasive assessment of non-calcified, calcified and mixed plaques. Progression of coronary plaques may be influenced by statins. METHODS:Sixty-three consecutive patients underwent MDCT as a follow-up to their original CT angiograp...
journal_title:European radiology
pub_type: 临床试验,杂志文章
doi:10.1007/s00330-010-1880-x
更新日期:2010-12-01 00:00:00
abstract::The diagnostic relevance of the relative T1-weighted (T1W) and T2-weighted (T2W)/short tau inversion recovery (STIR) MRI signal intensity characteristics of the superior to inferior fluid layers within fluid-fluid levels (FFLs) found in bone tumours was investigated. A retrospective analysis was performed of MRI studi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1060-4
更新日期:2008-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the impact of magnetic resonance neurography (MRN) on diagnostic thinking and therapeutic choices in patients with suspected peripheral neuropathy. METHODS:IRB approval was obtained for this HIPAA-compliant study. Questionnaires were administered to six surgeons regarding the diagnosis and treatm...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3958-y
更新日期:2016-05-01 00:00:00
abstract:OBJECTIVES:To investigate the correlation of right ventricular (RV) to left ventricular (LV) volume ratio measured by chest CT with pulmonary arterial systolic pressure (PASP) estimated by echocardiography. METHODS:104 patients (72.47 ± 13.64 years; 39 male) who had undergone chest CT and echocardiography were divided...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2454-x
更新日期:2012-09-01 00:00:00
abstract::Axillary management in patients with breast cancer has become much less invasive with the introduction of sentinel lymph node biopsy (SLNB). However, over 70 % of SLNBs are negative, questioning the generic use of this invasive procedure. Emerging evidence indicates that breast cancer patients with a low axillary burd...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-013-3009-5
更新日期:2014-02-01 00:00:00
abstract:OBJECTIVE:To evaluate the relationship of the liver-to-thoracic volume ratio (LiTR) by MRI with postnatal survival in foetuses with isolated congenital diaphragmatic hernia (CDH). METHODS:In 30 conservatively managed CDH foetuses and in 31 who underwent fetoscopic endoluminal tracheal occlusion (FETO), logistic regres...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2709-6
更新日期:2013-05-01 00:00:00
abstract::Insulinoma is the most common pancreatic endocrine tumor. Localization of small tumors remains a diagnostic challenge. Recently, Mangafodipir-enhanced MR imaging using a whole-body coil has been shown to be effective in the detection and staging of pancreatic cancer [3]. Localization of even small tumors is improved a...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-003-2017-2
更新日期:2004-05-01 00:00:00
abstract::The usefulness of diffusion-weighted magnetic resonance (MR) imaging (DWI) for differentiating central lung cancer from postobstructive lobar collapse (POC) was investigated. Thirty-three cases suspected of lung cancer and POC on chest bolus computed tomography (CT) underwent thoracic MR imaging examinations. MR exami...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-008-1134-3
更新日期:2009-02-01 00:00:00
abstract:OBJECTIVES:Post-imaging mathematical prediction models (MPMs) provide guidance for the management of solid pulmonary nodules by providing a lung cancer risk score from demographic and radiologists-indicated imaging characteristics. We hypothesized calibrating the MPM risk score threshold to a local study cohort would r...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06168-x
更新日期:2019-10-01 00:00:00
abstract::The aim of the study was to evaluate the role of MR urography (MRU) in the diagnosis of obstructive uropathy in selected groups of patients. The groups involved following pathologies: calculi; strictures of ureteropelvic junction (UPJ); benign and malignancy-induced ureterostenosis. Sixty patients with clinical diagno...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1550-8
更新日期:2003-04-01 00:00:00
abstract:OBJECTIVE:To investigate the value of histogram analysis of diffusion kurtosis imaging (DKI) maps in the evaluation of glioma grading. METHODS:A total of 39 glioma patients who underwent preoperative magnetic resonance imaging (MRI) were classified into low-grade (13 cases) and high-grade (26 cases) glioma groups. Par...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-5108-1
更新日期:2018-04-01 00:00:00
abstract:INTRODUCTION:Numerous publications have studied the regional anatomy of the carpal tunnel to define a "safe zone" to reduce the risk of perioperative neurovascular complications. This zone, located between the ulnar neurovascular bundle and the median nerve, is considered to be safe mainly because of the absence of vas...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06416-0
更新日期:2020-02-01 00:00:00
abstract:OBJECTIVES:To assess the value of a T1-3D black-blood turbo spin echo (TSE) sequence for the diagnosis of abdominal large vessel vasculitis (LVV). MATERIALS AND METHODS:The study included 20 patients with abdominal LVV and 17 controls, who underwent a 3T-MRI scan using a modified T1-3D volumetric isotropic TSE acquisi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06432-0
更新日期:2020-02-01 00:00:00
abstract::Digital imaging (digital image intensifier radiography, storage phosphor/selenium radiography) is increasingly becoming commonplace in radiology departments for diagnostic purposes. Despite 10 years of experience, the advantages and disadvantages of those methods are still heavily discussed among users, financiers and...
journal_title:European radiology
pub_type: 杂志文章
doi:
更新日期:1997-02-21 00:00:00
abstract:OBJECTIVES:To determine whether positioning of the arm in adduction and internal rotation would improve the confidence in the diagnosis of Bankart lesions in first time shoulder dislocators. METHODS:Eleven patients were imaged on an open bore MRI within 1-6 days of traumatic shoulder dislocation with the arm adducted ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2655-3
更新日期:2013-03-01 00:00:00
abstract:OBJECTIVES:To implement, examine, and compare three multichannel transmit/receive coil configurations for cardiovascular MR (CMR) at 7T. METHODS:Three radiofrequency transmit-receive (TX/RX) coils with 4-, 8-, and 16-coil elements were used. Ten healthy volunteers (seven males, age 28 ± 4 years) underwent CMR at 7T. F...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2487-1
更新日期:2012-10-01 00:00:00
abstract::The purpose of this prospective study was to measure lung attenuation at paired HRCT obtained at full inspiratory/expiratory position, to correlate with pulmonary function tests (PFTs) and to characterize different types of ventilatory impairment. One hundred fifty-five patients with and without pulmonary disease unde...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-002-1514-z
更新日期:2002-11-01 00:00:00
abstract:PURPOSE:Late gadolinium enhancement cardiac MR (LGE-CMR) and extracellular volume fraction (ECV-CMR) are widely used to evaluate macroscopic and microscopic myocardial fibrosis. Macrocyclic contrast media are increasingly used off-label for myocardial scar assessment, given the superior safety profile of these agents. ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5956-3
更新日期:2019-08-01 00:00:00
abstract:OBJECTIVES:To analyse the diagnostic accuracy and to establish a predictive score based on diffusion-weighted magnetic resonance imaging (DWMRI) compared to exploratory laparotomy (EL) for predicting suboptimal cytoreductive surgery for different intra-abdominal sites of implants in patients with ovarian cancer. METHO...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-013-2837-7
更新日期:2013-09-01 00:00:00
abstract:OBJECTIVES:At a European Society of Neuroradiology (ESNR) Annual Meeting 2015 workshop, commonalities in practice, current controversies and technical hurdles in glioma MRI were discussed. We aimed to formulate guidance on MRI of glioma and determine its feasibility, by seeking information on glioma imaging practices f...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-018-5314-5
更新日期:2018-08-01 00:00:00
abstract::The aim of the study was differential evaluation of new and classical sonographic features of benign thyroid nodules and thyroid cancer with three-dimensional gray-scale sonography and evaluation of the effectiveness of the thin-slice surface rendered images in comparison with multiplanar reformation (MPR) presentatio...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-2903-x
更新日期:2006-02-01 00:00:00
abstract::The aim of this study was to demonstrate that dose reduction and constant image quality can be achieved by adjusting X-ray dose to patient size. To establish the relation between patient size, image quality and dose we scanned 19 patients with reduced dose. Image noise was measured. Four radiologists scored image qual...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300101039
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVES:To identify CT findings in chronic hypersensitivity pneumonitis (cHP) associated with survival. MATERIAL AND METHODS:Two thoracic radiologists assessed CT scans for specific imaging findings and patterns in 132 subjects with cHP. Survival analyses were performed. RESULTS:The majority of subjects had an inc...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-017-4936-3
更新日期:2017-12-01 00:00:00
abstract::Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed tab...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-004-2288-2
更新日期:2004-07-01 00:00:00
abstract:OBJECTIVES:To compare the efficacy of ethanol ablation (EA) of cystic and predominantly cystic thyroid nodules, and to evaluate factors affecting efficacy. METHODS:From October 2008 to December 2010, a total of 217 thyroid nodules were treated with EA. Nodule volumes, symptoms and cosmetic scores were evaluated before...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-012-2406-5
更新日期:2012-07-01 00:00:00
abstract::To purpose of this paper is to study the relation between normal lung maturation signal and changes in intensity ratios (SIR) and to determine which magnetic resonance imaging sequence provides the strongest correlation of normal lung SIs with gestational age. 126 normal singleton pregnancies (20-37 weeks) were examin...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-006-0409-9
更新日期:2007-03-01 00:00:00
abstract::This report describes a malpractice case involving a delayed diagnosis of a malignant bone tumour in the proximal tibia in a 10-year-old child. This was caused by a combination of factors. The final report on the first examination failed to reach the patient files, and two subsequent X-ray exams failed to diagnose the...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300051021
更新日期:2000-01-01 00:00:00
abstract:OBJECTIVES:To evaluate post-ablation MRI for the detection of incompletely treated spinal osseous metastases (SOM) after cryoablation and to propose a post-ablation imaging classification. METHODS:After IRB consent, all patients treated with cryoablation of SOM between 2011 and 2017 having at least 1-year minimum foll...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-019-06040-y
更新日期:2019-10-01 00:00:00
abstract:PURPOSE:To evaluate the effect of CT perfusion (CTp) protocol modifications on quantitative perfusion parameters, radiation dose and data processing time. MATERIALS & METHODS:CTp datasets of 30 patients (21M:9F) with rectal (n = 24) or retroperitoneal (n = 6) tumours were studied. Standard CTp protocol included 50 sec...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-2048-4
更新日期:2011-06-01 00:00:00
abstract::The original version of this article, published on 01 August 2018, unfortunately contained two mistakes. ...
journal_title:European radiology
pub_type: 杂志文章,已发布勘误
doi:10.1007/s00330-018-5713-7
更新日期:2019-03-01 00:00:00