Calculation of cross-sectional geometry of bone from CT images with application in postmenopausal women.

Abstract:

OBJECTIVE:The objectives of this study were to develop a software program that calculates bone cross-sectional area (CSA) and moments of inertia from digital images, test the computations for accuracy, and implement the software in a study of longitudinal changes in bone properties in a large group of postmenopausal women. MATERIALS AND METHODS:A program called SLICE was adapted to use computed tomography (CT) bone images as input. The main outcome variables of the resulting program, SLICE_CT, were bone CSA, areal moments of inertia, and mass-weighted moments of inertia. SLICE_CT was tested for accuracy using representative arrays of CT numbers that approximate cross-sections of cortical bone. Then the technique was applied to images from a 3 year longitudinal study of the radius in 86 postmenopausal women who underwent quantitative CT of the dominant radius at 30% the distance from the wrist to the elbow. The mean age of the subjects at entry into the study was 57 years. Images at baseline and at 3 years were analyzed, and the null hypothesis of no change in cross-sectional geometry was tested by a paired difference two-tailed t test. RESULTS:The error of SLICE_CT was < 1% with proper segmentation, using half-maximal height as the threshold. In the longitudinal study of postmenopausal women, the mean change of CSA of the radius was -1.4% (SD = 3.0%; p < 0.001). However, there was a compensatory 2.4% increase in the cross-sectional second polar moment of inertia (SD = 3.7%; p < 0.001). CONCLUSION:SLICE_CT is an accurate method with which to determine cross-sectional geometry of digital images and can be used to detect changes in cross-sectional geometry of the radius with age in postmenopausal women. The results indicate that the radius remodels to compensate for bone loss and decreasing material properties of bone associated with aging.

journal_name

J Comput Assist Tomogr

authors

Corcoran TA,Sandler RB,Myers ER,Lebowitz HH,Hayes WC

doi

10.1097/00004728-199407000-00021

subject

Has Abstract

pub_date

1994-07-01 00:00:00

pages

626-33

issue

4

eissn

0363-8715

issn

1532-3145

journal_volume

18

pub_type

杂志文章
  • CT of appendicitis in children.

    abstract:PURPOSE:Our goal was to review the CT findings and to help define the role of CT in the evaluation of appendicitis in children. METHOD:Of 730 children with surgically proven appendicitis, 22 underwent preoperative CT evaluation. Their CT scans and operative and pathology records were retrospectively reviewed. The CT s...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199707000-00028

    authors: Jabra AA,Shalaby-Rana EI,Fishman EK

    更新日期:1997-07-01 00:00:00

  • Additional coronal images using low-milliamperage multidetector-row computed tomography: effectiveness in the diagnosis of bronchiectasis.

    abstract:PURPOSE:The aim of our study was to evaluate the effectiveness of additional coronal images using low-milliamperage multidetector-row computed tomography (CT) in the diagnosis of bronchiectasis. METHODS:Helical volumetric CT scans (120 kVp, 70 mA, 2.5-mm collimation, table speed of 15 mm/s, table rotation time of 1 se...

    journal_title:Journal of computer assisted tomography

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004728-200307000-00006

    authors: Sung YM,Lee KS,Yi CA,Yoon YC,Kim TS,Kim S

    更新日期:2003-07-01 00:00:00

  • Optimal scan delay in spiral CT for the diagnosis of acute pulmonary embolism.

    abstract:PURPOSE:The purpose of this work was to assess whether easily obtained clinical parameters can predict optimal scan delay for contrast-enhanced spiral CT of pulmonary arteries and to compare image quality between individualized contrast timing versus a fixed scan delay. METHOD:We used an individualized delay in 85 pat...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004728-200201000-00004

    authors: Hartmann IJ,Lo RT,Bakker J,de Monyé W,van Waes PF,Pattynama PM

    更新日期:2002-01-01 00:00:00

  • Vascular encasement by pancreatic cancer: correlation of CT findings with surgical and pathologic results.

    abstract:PURPOSE:The purpose of this study was to correlate thin-slice high-resolution helical CT findings of arterial and venous involvement in pancreatic cancers with surgical and histopathologic results. METHOD:Forty-eight patients with pancreatic cancer underwent preoperative thin-slice high-resolution helical CT, followed...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200105000-00002

    authors: Nakayama Y,Yamashita Y,Kadota M,Takahashi M,Kanemitsu K,Hiraoka T,Hirota M,Ogawa M,Takeya M

    更新日期:2001-05-01 00:00:00

  • Risk Factors Associated With Incomplete Colonoscopy Based on the Analysis of Computed Tomographic Colonography Findings.

    abstract:OBJECTIVE:This study aimed to identify the computed tomographic colonography (CTC) findings of incomplete colonoscopy compared with those of complete colonoscopy. METHODS:The clinical data and CTC imaging data from January 2004 to December 2012 were retrospectively obtained at 2 different institutions and reviewed by ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000741

    authors: Lee ES,Kim BC,Hur BY,Kim MJ,Park HJ,Park SB,Lee JB,Sohn DK,Han KS,Hong CW

    更新日期:2018-09-01 00:00:00

  • Role of magnetic resonance imaging as an adjunct to clinical staging in cervical carcinoma.

    abstract::Magnetic resonance imaging depicts the morphological details of the female pelvis and is useful for evaluating both benign and malignant cervical masses. Clinical assessment of the extent of cervical cancer is crucial in determining the optimal treatment strategy, but clinical staging by itself has limitations. Clinic...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181ed3090

    authors: Bhosale P,Peungjesada S,Devine C,Balachandran A,Iyer R

    更新日期:2010-11-01 00:00:00

  • Effects of chemonucleolysis demonstrated by MR imaging.

    abstract::In a study designed to assess the diagnostic and prognostic usefulness of magnetic resonance (MR) imaging in patients to be treated with chymopapain, 39 patients with a clinicoradiographic picture of herniated lumbar disk were scanned. Twenty-one of these, who were actually treated, were rescanned 3 months following t...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198611000-00004

    authors: Masaryk TJ,Boumphrey F,Modic MT,Tamborrello C,Ross JS,Brown MD

    更新日期:1986-11-01 00:00:00

  • Computed tomography of a benign mesenchymoma of soft tissue.

    abstract::Computed tomography of a benign mesenchymoma in a 7-year-old boy demonstrated bone and fat intermingled with nonspecific soft tissue. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198501000-00041

    authors: Hudson TM,Bertoni F,Enneking WF

    更新日期:1985-01-01 00:00:00

  • Computed tomographic distinction of perirenal liposarcoma from exophytic angiomyolipoma: a feature analysis study.

    abstract:PURPOSE:To identify computed tomographic (CT) findings that distinguish perirenal liposarcomas from exophytic angiomyolipomas. MATERIALS AND METHODS:We identified CT scans of 20 patients (13 women and 7 men; mean age, 63 years) with either perirenal liposarcoma (n = 11) proven at histopathology or large exophytic angi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181507534

    authors: Ellingson JJ,Coakley FV,Joe BN,Qayyum A,Westphalen AC,Yeh BM

    更新日期:2008-07-01 00:00:00

  • Dynamic helical CT of breast tumors.

    abstract:PURPOSE:The purpose of our study was to test dynamic helical CT (hCT) in the evaluation of breast tumors. METHOD:Thirty-six patients with 39 suspected lesions underwent breast hCT before and 1, 3, and 8 min after intravenous contrast medium administration. A marked enhancement (> or = 100%) at 1 or 3 min without incre...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199805000-00010

    authors: Sardanelli F,Calabrese M,Zandrino F,Melani E,Parodi R,Imperiale A,Massa T,Parodi G,Canavese G

    更新日期:1998-05-01 00:00:00

  • Utilization patterns and diagnostic yield of 3421 consecutive multidetector row computed tomography pulmonary angiograms in a busy emergency department.

    abstract:OBJECTIVE:To compare examination volume and diagnostic yield of computed tomography (CT) pulmonary angiography (CTPA) and ventilation-perfusion (V/Q) scintigraphy for detection of suspected pulmonary embolism (PE) in emergency department patients. METHODS:Every CTPA and V/Q scan result for emergency department patient...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31812e6af3

    authors: Donohoo JH,Mayo-Smith WW,Pezzullo JA,Egglin TK

    更新日期:2008-05-01 00:00:00

  • Limitations of CT in evaluation of neoplasms involving chest wall.

    abstract::We reviewed the CT of 20 patients with peripheral lung malignancies in which CT appearance suggested chest wall invasion on the basis of extension of mass around ribs into fat or muscle of the chest wall, or definite bone destruction. We correlated these findings with other radiographic studies and surgical and autops...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198703000-00019

    authors: Pearlberg JL,Sandler MA,Beute GH,Lewis JW Jr,Madrazo BL

    更新日期:1987-03-01 00:00:00

  • Assessment of global left ventricular function: comparison of cardiac multidetector-row computed tomography with angiocardiography.

    abstract:OBJECTIVE:Evaluation of left ventricular function using electrocardiogram (ECG)-gated multidetector row CT (MDCT) by using 3 different volumetric assessment methods in comparison to assessment of the left ventricular function by invasive ventriculography. METHODS:Thirty patients with suspected or known coronary artery...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000160426.41014.b1

    authors: Hundt W,Siebert K,Wintersperger BJ,Becker CR,Knez A,Reiser MF,Rubin GD

    更新日期:2005-05-01 00:00:00

  • Peripheral Nerve Sheath Tumors of Head and Neck: Imaging-Based Review of World Health Organization Classification.

    abstract::We aim to review the imaging appearance of peripheral nerve sheath tumors (PNSTs) of head and neck according to updated fourth edition of World Health Organization classification. Peripheral nerve sheath tumor can be sporadic or associated with neurofibromatosis type 1, neurofibromatosis type 2, and schwannomatosis. S...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/RCT.0000000000001109

    authors: Abdel Razek AAK,Gamaleldin OA,Elsebaie NA

    更新日期:2020-11-01 00:00:00

  • Physiological Laterality of Superficial Cerebral Veins on Susceptibility-Weighted Imaging.

    abstract:OBJECTIVE:The purpose of this study is to evaluate whether laterality of the superficial cerebral veins can be seen on susceptibility-weighted imaging (SWI) in patients with no intracranial lesions that affect venous visualization. METHODS:We retrospectively evaluated 386 patients who underwent brain magnetic resonanc...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000637

    authors: Matsushima S,Shimizu T,Gomi T,Fukuda K

    更新日期:2018-01-01 00:00:00

  • Adaptive Nonlocal Means Method for Denoising Basis Material Images From Dual-Energy Computed Tomography.

    abstract::We propose an adaptive nonlocal means approach for image-domain material decomposition in low-dose dual-energy micro-computed tomography. The key idea is to create a distribution map for decomposition error and assign a smooth weight for a given pixel. This method is applied to the decomposed images of 3 basis materia...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000805

    authors: Yuan Y,Zhang Y,Yu H

    更新日期:2018-11-01 00:00:00

  • Histopathology of uterine cervical carcinoma: diagnostic comparison of endorectal surface coil and standard body coil MRI.

    abstract:OBJECTIVE:We compared body coil (BC) MR images and endorectal surface coil (ERC) images with respect to the visualization of the cervix and adjacent tissues and the histopathologic correlations of the imaging findings. MATERIALS AND METHODS:Twenty-one patients with cervical carcinoma underwent MRI using both coils for...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Kaji Y,Sugimura K,Kitao M,Ishida T

    更新日期:1994-09-01 00:00:00

  • Can Dual-Energy Computed Tomography Quantitative Analysis and Radiomics Differentiate Normal Liver From Hepatic Steatosis and Cirrhosis?

    abstract:OBJECTIVES:This study aimed to assess if dual-energy computed tomography (DECT) quantitative analysis and radiomics can differentiate normal liver, hepatic steatosis, and cirrhosis. MATERIALS AND METHODS:Our retrospective study included 75 adult patients (mean age, 54 ± 16 years) who underwent contrast-enhanced, dual-...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000989

    authors: Doda Khera R,Homayounieh F,Lades F,Schmidt B,Sedlmair M,Primak A,Saini S,Kalra MK

    更新日期:2020-03-01 00:00:00

  • Virtual Monoenergetic Images for Diagnostic Assessment of Hypodense Lesions Within the Liver: Semiautomatic Estimation of Window Settings Using Linear Models.

    abstract:OBJECTIVE:The aim of the study was to establish the reference window settings for display of virtual monoenergetic images (VMIs) from spectral detector computed tomography when assessing hypodense liver lesions. METHODS:In patients with cysts (n = 24) or metastases (n = 26), objective (HU, signal-to-noise ratio [SNR])...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000794

    authors: Große Hokamp N,Obmann VC,Kessner R,Gilkeson RC,Gupta A,Persigehl T,Haneder S,Ramaiya N

    更新日期:2018-11-01 00:00:00

  • "Bridging vascular sign" in the MR diagnosis of exophytic uterine leiomyoma.

    abstract:PURPOSE:The purpose of this study was to evaluate the usefulness of the "bridging vascular sign" in the diagnosis of an exophytic uterine leiomyoma and differentiation of a uterine leiomyoma from some other mass arising in the adnexa on pelvic MRI. METHOD:Of 52 women with a pelvic mass in whom pelvic MRI was performed...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200001000-00012

    authors: Kim JC,Kim SS,Park JY

    更新日期:2000-01-01 00:00:00

  • Prototype Ultrahigh-Resolution Computed Tomography for Chest Imaging: Initial Human Experience.

    abstract:OBJECTIVE:The objective of this study was to evaluate a prototype, ultrahigh-resolution computed tomography offering higher reconstruction matrix (1024 × 1024) and spatial resolution (0.15 mm) for chest imaging. METHODS:Higher (1024) matrix reconstruction enabled by ultrahigh-resolution computed tomography scanner (12...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000917

    authors: Shanbhag SM,Schuzer JL,Steveson C,Rollison S,Bronson KC,Stagliano MS,Rogalla P,Blum A,Prokop M,Chen MY

    更新日期:2019-09-01 00:00:00

  • FDG-PET finding in early-phase Takayasu arteritis.

    abstract::We report a unique case of early-phase Takayasu arteritis in which the vessels demonstrated accumulation of [18F]fluorodeoxyglucose (FDG) on PET scanning. This observation suggests the possible use of FDG-PET for the diagnosis of vasculitis. Early diagnosis of Takayasu arteritis may permit early treatment and possibly...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199901000-00004

    authors: Hara M,Goodman PC,Leder RA

    更新日期:1999-01-01 00:00:00

  • Impact of the Number of Cores on the Prostate Cancer Detection Rate in Men Undergoing in-Bore Magnetic Resonance Imaging-Guided Targeted Biopsies.

    abstract:OBJECTIVE:To determine the incremental detection rate of clinically significant prostate cancer (csPCa) provided by sequential cores during in-bore magnetic resonance imaging (MRI)-guided prostate biopsies. METHODS:Single-center, retrospective interpretation of prospectively acquired data in men without previous diagn...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000001115

    authors: Subramanian N,Recchimuzzi DZ,Xi Y,Diaz de Leon A,Chen H,Xie D,Goldberg K,Rofsky NM,Pedrosa I,Costa DN

    更新日期:2020-12-02 00:00:00

  • Improved Image Quality and Decreased Radiation Dose of Lower Extremity Computed Tomography Angiography Using Low-Tube-Voltage and Adaptive Iterative Reconstruction.

    abstract:OBJECTIVE:The aim of the study was to investigate the feasibility of low-tube-voltage computed tomography (CT) in combination with 3-dimensional adaptive iterative dose reduction (AIDR-3D) algorithm in lower extremity CT angiography. METHODS:The CT data of the 120-kV group (n = 30) were reconstructed with filtered bac...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000356

    authors: Pan YN,Li AJ,Chen ZQ,Ren DW,Zhang J,Jiang MQ,Huang QL

    更新日期:2016-03-01 00:00:00

  • Computed tomography in hydatid disease of the liver: a report on 13 cases.

    abstract::Computed tomography (CT) findings in hydatid disease (echinococciasis) of the liver are described. Disease was caused by Echinococcus granulosus (n = 8) or E. alveolaris (n = 5), respectively. The CT appearance of these two types of echinococciasis is quite different; in disease caused by E. granulosus the CT appearan...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197811000-00018

    authors: Scherer U,Weinzierl M,Sturm R,Schildberg FW,Zrenner M,Lissner J

    更新日期:1978-11-01 00:00:00

  • Comparison and evaluation of rigid, affine, and nonrigid registration of breast MR images.

    abstract:PURPOSE:A new nonrigid registration method, designed to reduce the effect of movement artifact in subtraction images from breast MR, is compared with existing rigid and affine registration methods. METHOD:Nonrigid registration was compared with rigid and affine registration methods and unregistered images using 54 gad...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199909000-00031

    authors: Denton ER,Sonoda LI,Rueckert D,Rankin SC,Hayes C,Leach MO,Hill DL,Hawkes DJ

    更新日期:1999-09-01 00:00:00

  • Detection and mapping of abnormal brain structure with a probabilistic atlas of cortical surfaces.

    abstract:PURPOSE:We have devised, implemented, and tested a technique for creating a comprehensive probabilistic atlas of the human cerebral cortex, based on high-dimensional fluid transformations. The goal of the atlas is to detect and quantify subtle and distributed patterns of deviation from normal cortical anatomy, in a 3D ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199707000-00008

    authors: Thompson PM,MacDonald D,Mega MS,Holmes CJ,Evans AC,Toga AW

    更新日期:1997-07-01 00:00:00

  • Computed tomographic and clinicopathological features of inflammatory pseudotumor of the spleen.

    abstract:OBJECTIVE:Our goal was to elucidate the computed tomographic (CT) and clinicopathological features of inflammatory pseudotumor of the spleen. METHODS:Computed tomographic findings and clinic materials of 4 patients with inflammatory pseudotumor of the spleen were reviewed and compared with pathologic findings. RESULT...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000215

    authors: Lu T,Yang C

    更新日期:2015-05-01 00:00:00

  • Azygos continuation of inferior vena cava: CT appearance.

    abstract::Two cases demonstrating the computed tomographic appearance of azygos continuation of the inferior vena cava (IVC) are presented. One is associated with a retroaortic left renal vein and the other with a duplicated IVC. An enlarged azygos vein should not be confused with retrocrural lymphadenopathy or a mediastinal ma...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198006000-00015

    authors: Breckenridge JW,Kinlaw WB

    更新日期:1980-06-01 00:00:00

  • MR evaluation of the temporomandibular joint in juvenile rheumatoid arthritis.

    abstract::Temporomandibular joint (TMJ) disease is uncommon in children but frequently occurs in juvenile rheumatoid arthritis (JRA). Involvement is often asymptomatic; however, it can lead to growth disturbances and facial deformity. Thirty TMJs in 15 children (11 girls and 4 boys aged 3.5-18 years) with JRA were evaluated cli...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199305000-00022

    authors: Taylor DB,Babyn P,Blaser S,Smith S,Shore A,Silverman ED,Chuang S,Laxer RM

    更新日期:1993-05-01 00:00:00