The use of indirect immunofluorescence to evaluate the gel filtration method of fractionating human immunoglobulins.

Abstract:

:The indirect immunofluorescent technique has been shown to be a more sensitive method than either immunoelectrophoresis or gel filtration for testing the efficacy of the gel filtration method in fractionating human immunoglobulins. It has been confirmed that IgM fractions of some sera from patients with multiple sclerosis, contain antibody which reacts with measles virus-infected tissue culture cells.

journal_name

J Immunol Methods

authors

Hannon R,Haire M,Wisdom GB,Neill DW

doi

10.1016/0022-1759(75)90078-2

subject

Has Abstract

pub_date

1975-01-01 00:00:00

pages

29-36

issue

1-2

eissn

0022-1759

issn

1872-7905

pii

0022-1759(75)90078-2

journal_volume

8

pub_type

杂志文章
  • Multiplexed combinatorial tetramer staining in a mouse model of virus infection.

    abstract::Use of fluorescently labelled multimers, particularly tetramers of peptide and MHC class I glycoprotein (pMHC-I) complexes, is essential for the analysis of CD8+ T cell immunity in basic research and clinical settings. A recently described combinatorial approach using pMHC-I multimers coupled to a unique combination o...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2010.06.003

    authors: Cukalac T,Valkenburg SA,La Gruta NL,Turner SJ,Doherty PC,Kedzierska K

    更新日期:2010-08-31 00:00:00

  • Suitability of commercially available POC-CCA tests for schistosomiasis: Considerations for efficiency, reproducibility and decision making criteria for field application in areas of low endemicity.

    abstract:BACKGROUND:Point of care tests would be valuable for field diagnosis. However, high sensitivity will likely be required in low endemicity sets where individuals with low schistosome burden are hard to diagnose. METHODS:Commercially available POC tests (POC-CCA® and Urine CCA (Schisto) ECO Teste®) were evaluated to evi...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2019.06.006

    authors: Grenfell RFQ,Pedrosa ML,Couto FFB,Almeida A,Coelho PMZ,Katz N

    更新日期:2019-09-01 00:00:00

  • Development of a continuous IL-7-dependent murine pre-B cell line PB-1 suitable for the biological characterisation and assay of human IL-7.

    abstract::Human interleukin-7 (IL-7) is a cytokine that appears to be critical for early T- and B-cell development and although IL-7 is currently under investigation as a therapeutic agent in a variety of hematolymphopoietic disorders, there have been few instances of the detection or investigation of this cytokine using a biol...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/s0022-1759(99)00237-9

    authors: Mire-Sluis AR,Healey L,Griffiths S,Hockley D,Thorpe R

    更新日期:2000-03-06 00:00:00

  • Use of biotin-labeled monoclonal antibodies and avidin-peroxidase conjugates for the determination of epitope specificities in a solid-phase competitive enzyme immunoassay.

    abstract::The epitope specificities of monoclonal antibodies against carcinoembryonic antigen (CEA) were determined in a solid-phase, biotin-avidin enzyme immunoassay. Constant amounts of biotin-labeled antibodies were incubated with the immobilized antigen in the presence of decreasing amounts of unlabeled antibodies. The biot...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(84)90157-1

    authors: Wagener C,Fenger U,Clark BR,Shively JE

    更新日期:1984-03-30 00:00:00

  • Isolation of foot-and-mouth disease virus specific bovine antibody fragments from phage display libraries.

    abstract::Foot-and-mouth disease virus (FMDV) is an important veterinary pathogen which can cause widespread epidemics. Due to the high antigenic variability of FMDV, it is important to undertake mutation analysis under immunological pressure. To study the bovine antibody response at a molecular level, phage display technology ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2004.01.002

    authors: Kim YJ,Lebreton F,Kaiser C,Crucière C,Rémond M

    更新日期:2004-03-01 00:00:00

  • Automatic detection of hypoxia in renal tissue stained with HIF-1alpha.

    abstract:OBJECTIVE:The objective of this study was the identification of the stain HIF-alpha using the Image Cytometry, and to help to count the positive cells (with HIF-alpha) and the negative cells (without HIF-alpha) from the same sample. METHOD:17 images of renal tissues from male rats of Winstar lineage; overall, there we...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2017.02.005

    authors: Buzin AR,Macedo ND,De Araujo IB,Nogueira BV,de Andrade TU,Endringer DC,Lenz D

    更新日期:2017-05-01 00:00:00

  • Simultaneous detection of allotypes in native and activated human C2 by isoelectric focusing and silver staining.

    abstract::A simple and highly sensitive analytical isoelectric focusing (IEF) technique using immunofixation with anti-C2 serum followed by silver staining has been developed in order to study simultaneously the structural polymorphism of both native C2 and C2 activation fragments (C2a MW 74,000 and C2b MW 34,000). Structural C...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(89)90112-9

    authors: Segurado OG,Arnaiz-Villena A

    更新日期:1989-02-08 00:00:00

  • Ligand binding analysis of interleukin-2 receptor complexes using surface plasmon resonance.

    abstract::In this study we have employed surface plasmon resonance to examine the kinetic binding constants of a new class of soluble cytokine receptor complexes. The solution assembly of both homomeric and heteromeric interleukin-2 receptor ectodomain complexes has been achieved using coiled-coil molecular recognition. These c...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(95)00040-h

    authors: Wu Z,Johnson KW,Ciardelli TL

    更新日期:1995-06-14 00:00:00

  • Sensitive immunometric assays for secretory peroxidase and myeloperoxidase in human saliva.

    abstract::We have developed specific immunoassays for secretory peroxidase (SP) and for myeloperoxidase (MP) (polymorphonuclear leukocyte-derived peroxidase) in human saliva. Antibodies against SP and MP were produced using bovine milk lactoperoxidase (LP) and human MP as the immunogens, respectively. The methods developed are ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(91)90154-8

    authors: Vilja P,Lumikari M,Tenovuo J,Sievers G,Tuohimaa P

    更新日期:1991-08-09 00:00:00

  • Production and characterization of monoclonal antibodies against non-A1c glycated hemoglobin.

    abstract::Hybridomas secreting monoclonal antibodies specific for hemoglobin nonenzymatically glycated in the non-A1c position were produced by fusion of SP 2/0 myeloma cells with spleen cells from BALB/c mice immunized with nonenzymatically glycated hemoglobin prepared from human erythrocytes. Wells containing hydridomas secre...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(91)90364-l

    authors: Steward LA,Wu VY,Shea E,Cohen MP

    更新日期:1991-07-05 00:00:00

  • Preparation of human antibodies to insulin.

    abstract::Insulin was directly coupled and also indirectly coupled by a side chain to Sepharose 4B to form immunoabsorbents for affinity chromatography of insulin antibodies. The two direct derivatives were insulin lysyl and insulin phenylalanyl sepharose. The indirect derivative, insulin carboxyhexyl sepharose, was prepared in...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(77)90130-2

    authors: Jackson PA,Dixon K

    更新日期:1977-01-01 00:00:00

  • A simple reliable method for producing electron dense markers of uniform size for use in immunoelectron microscopy.

    abstract::A method is presented for the preparation of electron dense markers of defined size for use in immunoelectron microscopy, The electron dense markers were formed by the covalent binding of rabbit IgG and horse spleen ferritin mediated by glutaraldehyde. We demonstrated that the conjugate size, i.e. the number of ferrit...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(82)90124-7

    authors: Morris RE,Saelinger CB

    更新日期:1982-03-26 00:00:00

  • Preparation of soluble immune response suppressor and macrophage-derived suppressor factor.

    abstract::Concanavalin A-activated murine suppressor T cells act via the mediator, soluble immune response suppressor (SIRS) which non-specifically suppresses IgM and IgG antibody responses to a variety of antigens, cytotoxic T lymphocyte responses and proliferative responses to alloantigens and mitogens in vitro. SIRS is a pro...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(82)90235-6

    authors: Aune TM,Pierce CW

    更新日期:1982-08-27 00:00:00

  • A new method for double immunolabelling with primary antibodies from identical species.

    abstract::There are several double immunolabelling methods but each has its drawbacks. More often than not, antibodies with the required specificities are available in only one species and their use normally produces false labels due to cross-reactivity. We describe a new and reliable technique for staining with primary antibod...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(95)00281-2

    authors: Eichmüller S,Stevenson PA,Paus R

    更新日期:1996-04-19 00:00:00

  • A rapid method for isolation of antigenically active human cell surface antigens associated with beta 2-microglobulin using a monoclonal antibody.

    abstract::Serologically and biochemically pure HLA antigens and other beta 2-microglobulin-associated proteins were isolated using a rapid immunoprecipitation technique with a monoclonal anti-beta 2-microglobulin reagent A88. Elution of the immunoprecipitate with beta 2-microglobulin isolated from kidney patients proved to be e...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(81)90237-4

    authors: LeClair K,Van Agthoven A,Terhorst C

    更新日期:1981-01-01 00:00:00

  • Engineering higher affinity T cell receptors using a T cell display system.

    abstract::The T cell receptor (TCR) determines the cellular response to antigens, which are presented on the surface of target cells in the form of a peptide bound to a product of the major histocompatibility complex (pepMHC). The response of the T cell depends on the affinity of the TCR for the pepMHC, yet many TCRs have been ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2008.09.016

    authors: Chervin AS,Aggen DH,Raseman JM,Kranz DM

    更新日期:2008-12-31 00:00:00

  • Flow cytometric analysis of cytokine receptor signal transduction.

    abstract::Cytokines are critical regulators of the development and maturation of hematopoietic cells. Signal transduction via cytokine receptors proceeds through activation of the JAK-STAT pathway to stimulate cell proliferation, differentiation and effector functions. Phosphorylation of intracellular STAT molecules by the rece...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/s0022-1759(03)00177-7

    authors: Ilangumaran S,Finan D,Rottapel R

    更新日期:2003-07-01 00:00:00

  • Rapid and simple measurement of human C5a-des-Arg level in plasma or serum using monoclonal antibodies.

    abstract::A new sandwich immunoassay method for measuring human C5a-des-Arg was developed using monoclonal antibody specifically reactive with C5a-des-Arg. Monoclonal antibodies were obtained from a panel of hybridomas produced by fusion of mouse myeloma cells, P3 X 63-AG8,653, with spleen cells from a CBF1(C57BL/6 X BALB/c) mo...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(87)90159-1

    authors: Takeda J,Kinoshita T,Takata Y,Kozono H,Tanaka E,Hong K,Inoue K

    更新日期:1987-08-03 00:00:00

  • Measurement of immunoperoxidase activity. A rapid and reproducible immunoassay for quantitation of cellular antigens.

    abstract::A procedure is described making it possible to obtain quantitative data with the immunohistochemical peroxidase anti--peroxidase (PAP) technique. After applying PAP on fixed fibroblast preparations, peroxidase enzymic activity is measured on solubilized immune-complexes. The results show this technique to be sensitive...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(78)90114-x

    authors: Van Leuven F,Cassiman JJ,Van den Berghe H

    更新日期:1978-01-01 00:00:00

  • Comparative methodologies of regulatory T cell depletion in a murine melanoma model.

    abstract::There has been recent interest in the depletion of regulatory T cells (Tregs) as part of a multi-faceted approach to the immunotherapy of melanoma patients. This is in part due recent findings that convincingly show that Tregs are an integral part of regulating and even suppressing an immune response to growing tumor ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2008.01.012

    authors: Matsushita N,Pilon-Thomas SA,Martin LM,Riker AI

    更新日期:2008-04-20 00:00:00

  • An improved clonogenic culture method for thymic epithelial cells.

    abstract::A clonogenic assay system for thymic epithelial cells (TECs) is of crucial importance for identifying thymic epithelial stem and/or progenitor cells, evaluating their activities, and understanding the mechanisms of thymic involution. However, current systems are not sufficiently sensitive at detecting and quantifying ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2019.02.003

    authors: Sekai M,Wang J,Minato N,Hamazaki Y

    更新日期:2019-04-01 00:00:00

  • Sensitive ELISA for IgG and IgM anti-albumin autoantibodies not influenced by HBsAg-associated polyalbumin receptors.

    abstract::An enzyme immunoassay for the detection of IgG and IgM anti-polymerized albumin autoantibodies (AAA) is described. It was found that polyalbumin receptors on HBsAg particles interfere in the detection of IgG AAA when polymerized human albumin (pHSA), but not polymerized bovine albumin (pBSA), is used as coating antige...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(85)90484-3

    authors: Nardiello S,Pizzella T,Russo M,Galanti B

    更新日期:1985-01-21 00:00:00

  • An enzyme-linked immunosorbent assay (ELISA) for quantification of human collectin 11 (CL-11, CL-K1).

    abstract::Collectin 11 (CL-11), also referred to as collectin kidney 1 (CL-K1), is a pattern recognition molecule that belongs to the collectin group of proteins involved in innate immunity. It interacts with glycoconjugates on pathogen surfaces and has been found in complex with mannose-binding lectin-associated serine proteas...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2011.10.010

    authors: Selman L,Henriksen ML,Brandt J,Palarasah Y,Waters A,Beales PL,Holmskov U,Jørgensen TJ,Nielsen C,Skjodt K,Hansen S

    更新日期:2012-01-31 00:00:00

  • Expression of full-length immunoglobulins in Escherichia coli: rapid and efficient production of aglycosylated antibodies.

    abstract::Many research and clinical applications require large quantities of full-length antibodies with long circulating half-lives, and production of these complex multi-subunit proteins has in the past been restricted to eukaryotic hosts. In this report, we demonstrate that efficient secretion of heavy and light chains in a...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/s0022-1759(02)00036-4

    authors: Simmons LC,Reilly D,Klimowski L,Raju TS,Meng G,Sims P,Hong K,Shields RL,Damico LA,Rancatore P,Yansura DG

    更新日期:2002-05-01 00:00:00

  • Multiplex measurement of proinflammatory cytokines in human serum: comparison of the Meso Scale Discovery electrochemiluminescence assay and the Cytometric Bead Array.

    abstract::Serum cytokine profiling is a powerful tool to link host immune defense with disease pathogenesis. Although several multiplex assays are commercially available, none has been rigorously validated in the context of chronic infectious disease (such as HIV infection). Here we compared the measurement of proinflammatory c...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2011.06.033

    authors: Dabitao D,Margolick JB,Lopez J,Bream JH

    更新日期:2011-09-30 00:00:00

  • An anti-human t-lymphocyte antiserum. Further characterization of the specificity for T-cell subpopulations and a comparison of methods for identification of T-lymphocytes in tissue sections.

    abstract::An anti-human T-lymphocyte antiserum has been further studied for specificity for T-cell subpopulations and application in tissue sections. Using a complement-dependent microcytotoxicity assay about 60% of normal peripheral blood T-cells were found to be sensitive to lysis, while 40% were resistant. When the T-cell su...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(80)90149-0

    authors: Braathen LR

    更新日期:1980-01-01 00:00:00

  • Software compensation improves the analysis of heterogeneous tumor samples stained for multiparameter DNA flow cytometry.

    abstract:BACKGROUND:High concentrations of propidium iodide (PI), in combination with fluorescein isothiocyanate (FITC) and R-phycoerythrin (RPE) used for multiparameter DNA flow cytometry (FCM), cause spectral cross-talk into the green fluorescence channel (FL1). We have evaluated the use of post-acquisition software compensat...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/s0022-1759(01)00550-6

    authors: Corver WE,Fleuren GJ,Cornelisse CJ

    更新日期:2002-02-01 00:00:00

  • Performance evaluation of the MBio Diagnostics point-of-care CD4 counter.

    abstract::The measurement of the absolute CD4 T-cell count is critical in the initial evaluation and staging of HIV-infected persons, yet access to this technology remains limited in many low resource settings where disease burden is highest. Here we evaluate the performance of a prototype point-of-care device (POC) to quantify...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/j.jim.2012.10.002

    authors: Logan C,Givens M,Ives JT,Delaney M,Lochhead MJ,Schooley RT,Benson CA

    更新日期:2013-01-31 00:00:00

  • An improved, ultrasensitive method for the detection of IgM oligoclonal bands in cerebrospinal fluid.

    abstract::A new, 10-fold more sensitive method, based on an improved immunofixation technique, has been devised to detect oligoclonal IgM bands in unconcentrated cerebrospinal fluid (CSF). Using agarose gel electrophoresis, 5 microliters of an unconcentrated sample containing oligoclonal bands was separated and blotted on to a ...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/s0022-1759(97)00023-9

    authors: Rijcken CA,Thompson EJ,Teelken AW

    更新日期:1997-04-25 00:00:00

  • A new and rapid method for immunoglobulin class and subclass determination of mouse monoclonal antibodies using a solid-phase immunoradiometric assay.

    abstract::A solid-phase immunoradiometric assay is described for the detection of mouse immunoglobulin classes and subclasses in unpurified and unconcentrated supernatants of hybridomas. IgG fractions from rabbit antisera specific for mouse immunoglobulin classes and subclasses are used for coating the wells of flexible microti...

    journal_title:Journal of immunological methods

    pub_type: 杂志文章

    doi:10.1016/0022-1759(84)90161-3

    authors: Storch MJ,Lohmann-Matthes ML

    更新日期:1984-03-30 00:00:00