Traumatic amputation of the upper limb: the use of body-powered prostheses and employment consequences.

Abstract:

:Forty three patients with unilateral traumatic amputations were reviewed as to the use of prostheses and employment consequences of the amputation. Seventeen of 19 below-elbow amputees, and 12 of 24 above-elbow amputees used their prostheses. Non-users compared to users of prostheses were characterized by: 1) Higher level of amputation 2) Non-dominant arm amputation and 3) Younger age at the time of amputation. However non-users usually did well on the labour market for various reasons.

journal_name

Prosthet Orthot Int

authors

Stürup J,Thyregod HC,Jensen JS,Retpen JB,Boberg G,Rasmussen E,Jensen S

doi

10.3109/03093648809079390

subject

Has Abstract

pub_date

1988-04-01 00:00:00

pages

50-2

issue

1

eissn

0309-3646

issn

1746-1553

journal_volume

12

pub_type

杂志文章
  • Comparison of the efficacy of laterally wedged insoles and bespoke unloader knee orthoses in treating medial compartment knee osteoarthritis.

    abstract:BACKGROUND:Patients suffering from medial compartment knee osteoarthritis (OA) may be treated with unloader knee orthoses or laterally wedged insoles. OBJECTIVES:The aim of this study was to identify and compare the effects of them on the gait parameters and pain in these patients. STUDY DESIGN:Quasi-experimental. M...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,随机对照试验

    doi:10.1177/0309364612447094

    authors: Arazpour M,Bani MA,Maleki M,Ghomshe FT,Kashani RV,Hutchins SW

    更新日期:2013-02-01 00:00:00

  • Development of a method for fabricating polypropylene non-articulated dorsiflexion assist ankle foot orthoses with predetermined stiffness.

    abstract:BACKGROUND:A non-articulated plantarflexion resist ankle foot orthosis (AFO), commonly known as a posterior leaf spring AFO, is indicated for patients with motor impairment to the dorsiflexors. The AFO is often custom molded to a patient's lower limb anatomy and fabricated from polypropylene. There are no established g...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364610394477

    authors: Ramsey JA

    更新日期:2011-03-01 00:00:00

  • Measurement of maximal end-weight-bearing in lower limb amputees.

    abstract::Modern sockets for lower limb amputees utilize total contact and distribute some weight on the stump end. Its tolerance to bear weight varies but is better after joint disarticulation, however, systematic measures have been missing. Different levels, indications, shapes etc. were analysed with 102 measurements in 69 p...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648209166575

    authors: Persson BM,Liedberg E

    更新日期:1982-12-01 00:00:00

  • A mechanically-actuated wave mattress.

    abstract::A polio victim who has been in a negative pressure ventilator ("iron lung") since 1950 was in need of an activated mattress to combat the hallucinatory effects of complete immobilization and to assist with body pressure distribution. A mechanical method was used to give the patient's mattress a moving wave form of ver...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093647809177773

    authors: Brearley MN,Motloch WM

    更新日期:1978-08-01 00:00:00

  • Weight bearing and velocity in trans-tibial and trans-femoral amputees.

    abstract::The purpose of this study was to review the clinical utility of static weight bearing (SWB) and maximal self-selected ambulatory velocity as objective quantifiable measures in an outpatient lower limb prosthetic clinic. Seventy-three (n = 73) consecutive trans-tibial (TTA) and trans-femoral amputees (TFA) attending an...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.3109/03093649709164553

    authors: Jones ME,Bashford GM,Mann JM

    更新日期:1997-12-01 00:00:00

  • Analysis of the swing phase dynamics and muscular effort of the above-knee amputee for varying prosthetic shank loads.

    abstract::The purpose of this study was to determine the effect of varying prosthetic shank mass, while maintaining the mass centre location and moment of inertia, on the swing phase kinematics, kinetics and hip muscular effort of free speed above-knee (AK) amputee gait. Six AK amputees, wearing similar prosthetic designs, had ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649009080338

    authors: Hale SA

    更新日期:1990-12-01 00:00:00

  • CIR Casting System for making transtibial sockets.

    abstract::This paper describes a new casting system for transtibial socket fabrication. Like the earlier CIR Sand Casting System, the CIR Casting System is based on the 'dilatancy' principle that is similar to the packaging process for coffee beans by which loose beans become a solid mass when a vacuum is applied. The main diff...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802446703

    authors: Wu Y,Casanova HR,Reisinger KD,Smith WK,Childress DS

    更新日期:2009-03-01 00:00:00

  • Variability of kinetic variables during gait in unilateral transtibial amputees.

    abstract:BACKGROUND:Prosthetic gait increases demands on stability. Some variability measures can be used to investigate the stability of movement for prosthetic feet. OBJECTIVES:The purpose of this study was to determine the influence of the prosthetic foot on ground reaction force variability for transtibial amputee gait. S...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364612439572

    authors: Svoboda Z,Janura M,Cabell L,Elfmark M

    更新日期:2012-06-01 00:00:00

  • The importance of being earnest about shank and thigh kinematics especially when using ankle-foot orthoses.

    abstract::This paper reviews and summarizes the evidence for important observations of normal and pathological gait and presents an approach to rehabilitation and orthotic management, which is based on the significance of shank and thigh kinematics for standing and gait. It discusses normal gait biomechanics, challenging some t...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.3109/03093646.2010.485597

    authors: Owen E

    更新日期:2010-09-01 00:00:00

  • Comparison of CAD-CAM and hand made sockets for PTB prostheses.

    abstract::The aim of the present study was to compare sockets for below-knee (BK) prostheses made by Computer Aided Design-Computer Aided Manufacture (CAD-CAM) to those made by hand. The patients in the study were provided with two prostheses each, which apart from the sockets, were identical. One socket was made by the CAD-CAM...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648909079405

    authors: Köhler P,Lindh L,Netz P

    更新日期:1989-04-01 00:00:00

  • Taxonomy of clinical encounters during the first 90 days post-delivery of an initial lower limb prosthesis.

    abstract:BACKGROUND:The incidence and etiology of prosthetic services utilization is poorly understood during the first 90 days post-delivery of the initial lower limb prosthesis. This period is of critical importance, as prevailing policy dictates limits on the reimbursement for certain services provided during this time perio...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364618774053

    authors: Lee DJ,Wininger M,Mahler D,Parisi M

    更新日期:2018-10-01 00:00:00

  • Changes in the corticospinal tract after wearing prosthesis in bilateral transtibial amputation.

    abstract:BACKGROUND:After amputation, the brain is known to be reorganized especially in the primary motor cortex. We report a case to show changes in the corticospinal tract in a patient with serial bilateral transtibial amputations using diffusion tensor imaging. Case Description and Methods: A 78-year-old man had a transtibi...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章,评审

    doi:10.1177/0309364616684216

    authors: Lee SY,Kang SH,Kim DK,Seo KM,Ro HJ,Kim JK

    更新日期:2017-10-01 00:00:00

  • Contact dermatitis to cobalt chloride with an unusual mechanism.

    abstract:BACKGROUND:Contact dermatitis is a frequent inflammatory skin disease. A suspected diagnosis is based on clinical symptoms, a plausible contact to allergens and a suitable history of dermatitis. Therefore, careful diagnosis by patch testing is of great importance because the patch testing is important to find out which...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614534293

    authors: Arslan S,Aksan S,Ucar R,Caliskaner AZ

    更新日期:2015-10-01 00:00:00

  • A study of 200 cases of congenital limb deficiencies.

    abstract::An analysis of 200 patients with congenital limb deficiency who attended the Artificial Limb Centre, Pune from January 1984 to April 1990 is presented. This group is representative of the congenital limb deficient population of the country. The commonest deficiencies were transverse phalangeal total/partial deficiency...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164402

    authors: Jain SK

    更新日期:1994-12-01 00:00:00

  • The DEKA Arm: its features, functionality, and evolution during the Veterans Affairs Study to optimize the DEKA Arm.

    abstract:BACKGROUND AND AIM:DEKA Integrated Solutions Corp. (DEKA) was charged by the Defense Advanced Research Project Agency to design a prosthetic arm system that would be a dramatic improvement compared with the existing state of the art. The purpose of this article is to describe the two DEKA Arm prototypes (Gen 2 and Gen ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364613506913

    authors: Resnik L,Klinger SL,Etter K

    更新日期:2014-12-01 00:00:00

  • New concept of spinal orthosis for weakened back muscles.

    abstract::An anterior bending posture of the trunk during walking is often seen among the elderly commonly due to weakened thoraco-lumbar and gluteal muscles. For the management of this debilitating condition, the authors have developed a modified design of thoraco-lumbosacral orthosis (TLSO). Incorporated in this device are po...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649509078233

    authors: Watanabe H,Kutsuna T,Asami T,Inoue E

    更新日期:1995-04-01 00:00:00

  • Rasch analysis of the Locomotor Capabilities Index-5 in people with lower limb amputation.

    abstract::The aim of this study was to perform a Rasch analysis on the 5-level ordinal scale version of the Locomotor Capabilities Index (LCI-5), in order to investigate rating scale quality and conduct reliability and validity assessments. A questionnaire was mailed to 144 subjects who had undergone lower limb amputation (LLA)...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640701253952

    authors: Franchignoni F,Giordano A,Ferriero G,Muñoz S,Orlandini D,Amoresano A

    更新日期:2007-12-01 00:00:00

  • Importance of neurological evaluation before reverse shoulder arthroplasty in patients with previous poliomyelitis.

    abstract::We present a case report of a patient, affected by post-polio syndrome and cuff tear arthropathy of his right shoulder, who underwent reverse shoulder arthroplasty. A previous radial deficiency was unmasked in the post-operative follow-up, with passive elbow bending when the forearm was put in an antigravitational pos...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640802425459

    authors: Castoldi F,Lollino N,Caranzano F,Assom M

    更新日期:2009-06-01 00:00:00

  • Functional outcome of lower-limb amputees: a prospective descriptive study in a general hospital.

    abstract::This paper describes functional outcome of a population of lower limb amputees five months after amputation compared with their preoperative functional abilities and studies the relationship between potential determinants and functional outcome. Twenty out of 26 patients who underwent a lower limb amputation between D...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649609164423

    authors: Greive AC,Lankhorst GJ

    更新日期:1996-08-01 00:00:00

  • Failures in through-knee amputation.

    abstract::Long-term results over a period of more than 10 years give evidence of the superiority of the through-knee compared to the above-knee stump. However, failures in through-knee stumps before, during and after operation and pitfalls in prosthetic fitting are still too frequent. They are mostly due to errors because the p...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648309166986

    authors: Baumgartner R

    更新日期:1983-08-01 00:00:00

  • A CAD analysis programme for prosthetics and orthotics.

    abstract::A CAD (computer aided design) analysis software package (CADVIEW) was designed for use with prosthetic and orthotic CAD CAM (computer aided design/computer aided manufacture) systems. Using the Microsoft Windows 3.1 environment, CADVIEW provides a series of anatomical shape viewing and analysis tools. These tools incl...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649409164393

    authors: Lemaire E

    更新日期:1994-08-01 00:00:00

  • Comparison of prosthetic outcomes between adolescent transtibial and transfemoral amputees after Sichuan earthquake using Step Activity Monitor and Prosthesis Evaluation Questionnaire.

    abstract:BACKGROUND:The devastating earthquake in Sichuan in 2008 has left many adolescent amputees. However, little research has been focused on the adolescent amputees who have high potential to return to premorbid activity level. OBJECTIVES:To investigate daily step activities and prosthesis-related quality of life of the a...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364614556837

    authors: Chu CK,Wong MS

    更新日期:2016-02-01 00:00:00

  • A reference shape library for computer aided socket design in above-knee prostheses.

    abstract::A Reference Library of socket shapes for an Above-Knee Computer Aided Socket Design (CASD) System has been created. This library forms part of a more general CASD System (Dean & Saunders, 1985; Novicov & Foort, 1982). It consists of a matrix of reference shapes representing above-knee socket characteristics and is bas...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648909079421

    authors: Torres-Moreno R,Foort J,Morrison JB,Saunders CG

    更新日期:1989-12-01 00:00:00

  • Principal structural testing of trans-tibial prosthetic assemblies: specimen preparation.

    abstract::A simple alignment apparatus and the method of transferring the offset test load to the prosthetic assembly through an aligned mandrel for the principal structural tests in accordance with ISO 10328 is presented. The new alignment apparatus was used to prepare test specimens consisting of traditional laminated prosthe...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1080/03093640008726554

    authors: Neo LD,Lee PV,Goh JC

    更新日期:2000-12-01 00:00:00

  • Multi-segment kinematic model to assess three-dimensional movement of the spine and back during gait.

    abstract:BACKGROUND:Relatively little is known about spine during gait compared to movement analysis of the lower extremities. The trunk is often regarded and analysed as a single rigid segment and there is a paucity of information on inter-segmental movement within the spine and its relationship to pelvis and lower limbs. OBJ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364615579319

    authors: Needham R,Naemi R,Healy A,Chockalingam N

    更新日期:2016-10-01 00:00:00

  • The treatment of longitudinal ulnar deficiency.

    abstract::Longitudinal ulnar deficiency, whose detailed anatomy is varied, is often accompanied by other abnormalities and appears as part of several syndromes. The history of its classification is reviewed, and the treatments, which have been offered, described. Follow-up of a series shows that the function achieved is good an...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649109164643

    authors: Lovett RJ

    更新日期:1991-08-01 00:00:00

  • Results of the pilot phase of a clinical evaluation of computer aided design of trans-tibial prosthesis sockets.

    abstract::This study served as a pilot to develop the methodology for a larger number of clinical trials. Ten trans-tibial amputees compared sockets made by conventional methods with sockets made using computer aided socket design (CASD). Prosthetists, paired for experience, fitted each subject with one prosthesis using each me...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093648609164519

    authors: Holden JM,Fernie GR

    更新日期:1986-12-01 00:00:00

  • Function after through-knee compared with below-knee and above-knee amputation.

    abstract::Fifty-nine amputees, 24 below-knee (BK), 17 through-knee (TK) and 18 above-knee (AK) who had prosthetic replacements, were evaluated using a questionnaire which provided a quantitative and qualitative assessment scale for the prosthetic function. The ability to apply or don the prosthesis was noted in 100% of the BK, ...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.3109/03093649209164336

    authors: Hagberg E,Berlin OK,Renström P

    更新日期:1992-12-01 00:00:00

  • Comparison of gait between healthy participants and persons with spinal cord injury when using the advanced reciprocating gait orthosis.

    abstract:BACKGROUND:The advanced reciprocating gait orthosis (ARGO) has a rigid structure which provides restricted movement at the hip, knee, and ankle joints and incorporates a pelvic section with an extended section in the lumbar region. Healthy subjects, when walking with an RGO in situ, could feasibly demonstrate the level...

    journal_title:Prosthetics and orthotics international

    pub_type: 杂志文章

    doi:10.1177/0309364615592699

    authors: Arazpour M,Joghtaei M,Bahramizadeh M,Ahmadi Bani M,Hutchins SW,Curran S,Mousavi ME,Sharifi G,Mardani MA

    更新日期:2016-04-01 00:00:00

  • A new approach for the pistoning measurement in transtibial prosthesis.

    abstract:BACKGROUND:Good suspension lessens the pistoning (vertical displacement) of the residual limb inside the prosthetic socket. Several methods are used for measuring the pistoning. STUDY DESIGN:Clinical trial. OBJECTIVES:To introduce and evaluate a new simple method for measuring the pistoning between the soft liner and...

    journal_title:Prosthetics and orthotics international

    pub_type: 临床试验,杂志文章

    doi:10.1177/0309364611423130

    authors: Gholizadeh H,Abu Osman NA,Lúvíksdóttir Á,Eshraghi A,Kamyab M,Wan Abas WA

    更新日期:2011-12-01 00:00:00