Establishment of reference intervals for pediatric complete capillary blood counts: A multicenter study in Beijing.

Abstract:

INTRODUCTION:Clinical reference intervals represent the normal range of clinical parameters for distinguishing healthy and sick individuals, and they show some variation among different populations. Many reference intervals are still lacking for the pediatric population in China. Thus, the aim of this study was to establish and validate pediatric reference intervals for capillary blood cell counts. METHODS:A total of 9942 children were enrolled from 10 medical institutions in Beijing, China, for capillary complete blood count (CCBC) values according to the EP28-A3c guideline issued by the Clinical and Laboratory Standards Institute. RESULTS:Pediatric reference intervals for 17 CCBC parameters were established for children aged 6 months to 7 years. The red blood cell count and red blood cell distribution width were generally higher in males than in females, and the mean corpuscular hemoglobin and mean corpuscular volume were higher in females than in males. The red blood cell, hemoglobin, hematocrit, and neutrophil percentages increased while the percentage of lymphocytes decreased with age. The overall trends for each reference interval were relatively similar in different ethnic groups and regions in the world, but with variation in the upper and lower limits, which confirms the existence of racial and geographical differences. Further validation with 508 healthy subjects showed that the verified proportions were within 90.9%-100% of the reference intervals. CONCLUSIONS:This study offers local reference intervals for CCBC values for the pediatric population in Beijing, China, and thus provides basic criteria for the diagnosis, treatment, and health assessment of childhood diseases in China.

journal_name

Int J Lab Hematol

authors

Sun Q,Yue Y,Tian Y,Wang Q

doi

10.1111/ijlh.13150

subject

Has Abstract

pub_date

2020-10-01 00:00:00

pages

533-543

issue

5

eissn

1751-5521

issn

1751-553X

journal_volume

42

pub_type

杂志文章
  • Different kinetic patterns of BCR-ABL transcript levels in imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response.

    abstract::Bone marrow BCR-ABL transcript levels were monitored serially by real-time quantitative PCR in 46 imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response (CCyR) for a median of 42 months (range: 9-53). Of 41 patients in continuous CCyR, 32 and nine could achieve a >/=3-log (MMo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00962.x

    authors: Qin YZ,Liu YR,Zhu HH,Li JL,Ruan GR,Zhang Y,Jiang Q,Jiang H,Li LD,Chang Y,Huang XJ,Chen SS

    更新日期:2008-08-01 00:00:00

  • A hierarchical approach in the diagnostic workflow of chronic myelomonocytic leukemia: Pivotal role of the "Mono-dysplasia-score" combined with flow cytometric quantification of monocyte subsets.

    abstract:INTRODUCTION:Monocytosis is a frequent trigger for blood smear review in a routine hematology laboratory whereas chronic myelomonocytic leukemia (CMML) is infrequent and arises mostly in elderly patients. In order to define the best workflow for monocytosis, we studied three diagnostic approaches: the classical morphol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13115

    authors: Zhu J,Sourdeau E,Aubert H,Clauser S,Maillon A,Capron C,Jondeau K,Ronez E,Schillinger F,Garnache-Ottou F,Cornet E,Bardet V

    更新日期:2019-12-01 00:00:00

  • Guidance for storing blood samples in laboratories performing complete blood count with differential.

    abstract:INTRODUCTION:The complete blood count (CBC) with differential leukocyte count (DIFF) is an important part of clinical laboratory analyses and provides crucial data for clinicians. Delivery time after blood collection and conditions of storage is known to affect the reliability of results of some hematologic parameters....

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01452.x

    authors: Cornet E,Behier C,Troussard X

    更新日期:2012-12-01 00:00:00

  • Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.

    abstract:INTRODUCTION:The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in pa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01305.x

    authors: Lima-Oliveira G,Lippi G,Salvagno GL,Montagnana M,Scartezini M,Guidi GC,Picheth G

    更新日期:2011-10-01 00:00:00

  • Hemostasis critical values among Iranian clinical laboratories "National Survey of 157 Clinical Laboratories".

    abstract:BACKGROUND:Immediate reporting of critical values or test results significantly outside the normal range has a growing role in the management of patients, especially in life-threatening conditions. Due to the lack of international consensus, diverse approaches are used for determination of thresholds, reporting, docume...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13109

    authors: Dorgalaleh A,Shiravand Y,Dabbagh A,Tabibian S,Hosseini MS,Mansouri Tourghabeh H,Rashidpanah J,Narouei F,Shams M,Gholami MS,Saneei Moghaddam E,Shahreki H

    更新日期:2019-12-01 00:00:00

  • Blood parameters of preterm neonates: postnatal evolution according to gestational age.

    abstract:INTRODUCTION:The blood count provides qualitative and quantitative essential information on bloodlines. Reference hematologic parameters have been established in children and neonates, but few data are available regarding the premature population during the first month of life. The main objective of this study was to e...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12629

    authors: Roudil P,Vasselon C,Trombert-Paviot B,Berger C,Patural H

    更新日期:2017-06-01 00:00:00

  • Performance evaluation of a new Stago® automated haemostasis analyser: The STA R Max® 2.

    abstract:INTRODUCTION:The STA R Max® 2 is a new coagulation analyser developed by Diagnostica Stago, able to perform clotting, chromogenic and immuno-turbidimetric tests. A pre-analytical module build into the cap-piercing needle performs the sample integrity verification (sample tube filling and measurement of haemolysis, icte...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13100

    authors: Cupaiolo R,Govaerts D,Blauwaert M,Cauchie P

    更新日期:2019-12-01 00:00:00

  • Factor XIII-A subunit Val34Leu polymorphism in fatal hemorrhagic stroke.

    abstract::Blood coagulation factor XIII (FXIII) plays a key role in the protection of fibrin clot against fibrinolysis, in the cross-linking of fibrin and its mechanical strength. The role of the FXIII-A subunit Val34Leu polymorphism with fatal primary intracerebral hemorrhages (PICH) has not been studied. We evaluated retrospe...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01465.x

    authors: Antalfi B,Pongrácz E,Csiki Z,Mezei ZA,Shemirani AH

    更新日期:2013-02-01 00:00:00

  • Limitation of the activated partial thromboplastin time as a monitoring method of the direct thrombin inhibitor argatroban.

    abstract:BACKGROUND:Argatroban is licensed for patients with heparin-induced thrombocytopenia and monitoring is conventionally by activated partial thromboplastin time (APTT) ratio with a target of 1.5-3.0 and not exceeding 100 s. The APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Variabl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12414

    authors: Guy S,Kitchen S,Maclean R,Van Veen JJ

    更新日期:2015-12-01 00:00:00

  • A rare case of Lennert's type peripheral T-cell lymphoma with t(14;19)(q11.2;q13.3).

    abstract::Although most patients with peripheral T-cell lymphoma (PTCL) show clonal rearrangement of T-cell receptor genes, few PTCLs show recurrent chromosomal abnormalities. We describe here a rare chromosomal rearrangement, t(14;19)(q11.2;q13.3), in a Lennert's lymphoma, a variant of PTCL, not otherwise specified. Sequential...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01385.x

    authors: Shin SY,Jang S,Park CJ,Chi HS,Lee KH,Huh J,Seo EJ

    更新日期:2012-06-01 00:00:00

  • Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

    abstract:INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12486

    authors: Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

    更新日期:2016-06-01 00:00:00

  • Expression of CD4 is correlated with an unfavorable prognosis in wild-type NPM1, FLT3-ITD-negative cytogenetically normal adult acute myeloid leukemia.

    abstract:INTRODUCTION:In the cytogenetically normal population of AML (CN-AML), FLT3-ITD-positive and wild-type NPM1 is correlated with a worse outcome, and FLT3-ITD-negative with NPM1-mut is correlated with a better outcome. This leaves a large subpopulation of CN-AML patients without NPM1 or FLT3-ITD mutations with heterogene...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12649

    authors: Guo RJ,Atenafu EG,Schimmer AD,Minden MD,Chang H

    更新日期:2017-08-01 00:00:00

  • Platelet size has diagnostic predictive value for bone marrow metastasis in patients with solid tumors.

    abstract::Though not very common, solid tumor involvement of the bone marrow (BM) may have serious consequences. Recent studies have shown that mean platelet volume (MPV) is a good indicator for BM disease in the differential diagnosis of thrombocytopenia. We investigated the significance of MPV in the diagnosis of BM metastasi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00947.x

    authors: Aksoy S,Kilickap S,Hayran M,Harputluoglu H,Koca E,Dede DS,Erman M,Turker A

    更新日期:2008-06-01 00:00:00

  • Flow cytometry in the diagnosis of mature B-cell lymphoproliferative disorders.

    abstract::B-lineage lymphoproliferative disorders (LPD) are rather frequent diseases, associated with specific clinical or biological features but also sometimes of fortuitous discovery. Multiparameter flow cytometry plays a major role for a rapid diagnostic indication, on peripheral blood or bone marrow samples in most instanc...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13170

    authors: Debord C,Wuillème S,Eveillard M,Theisen O,Godon C,Le Bris Y,Béné MC

    更新日期:2020-06-01 00:00:00

  • Low expression of TET2 gene in pediatric acute lymphoblastic leukemia is associated with poor clinical outcome.

    abstract:INTRODUCTION:TET2, a member of the Ten-Eleven translocation gene family, catalyzes the conversion of 5-methylcytosine to 5-hydroxymethylcytosine in DNA. Low expression of TET2 has been reported as a prognostic factor for several types of malignancies in adult patients. However, there have been few data on the effect of...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13099

    authors: Zhang P,Weng WW,Chen P,Zhang Y,Ruan JF,Ba DD,Xu WQ,Tang YM

    更新日期:2019-10-01 00:00:00

  • Falciparum malaria parasitemia index for predicting severe malaria.

    abstract:INTRODUCTION:While hyperparasitemia is considered an important indicator for the development of severe malaria, there is currently no consensus on the quantitative definition of hyperparasitemia. This study was conducted to establish a cutoff point for peripheral parasitemia among patients with Plasmodium falciparum ma...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01398.x

    authors: Tangpukdee N,Krudsood S,Kano S,Wilairatana P

    更新日期:2012-06-01 00:00:00

  • Evaluation of a new venom-based clotting assay of protein C.

    abstract::Congenital protein C deficiency significantly increases the risk of venous thromboembolism, a serious and potentially lethal condition. Protein C levels can be determined by chromogenic, clotting and antigenic assays, each type of assay has differences in specificity and sensitivity to protein C deficiency. In princip...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00972.x

    authors: Cooper PC,Cooper SM,Goodfellow KJ,Hickey KP,Kitchen S,Makris M

    更新日期:2008-10-01 00:00:00

  • Establishment of reference intervals for complete blood count parameters in venous blood for children in the Xiamen area, China.

    abstract:OBJECTIVES:To observe changes in the complete blood count (CBC) venous blood parameters of healthy children and establish appropriate reference intervals (RIs). METHODS:Overall, 4066 healthy children were selected and divided into four groups: infants, toddlers, preschool-age children and school-age children. Venous b...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13095

    authors: Li J,Zhang H,Huang X,Zhang J,Wu X

    更新日期:2019-10-01 00:00:00

  • Live remote digital microscopy in peripheral blood smear evaluation: Intraobserver concordance and experience.

    abstract:INTRODUCTION:Peripheral blood smear (PBS) review is a routine laboratory test which requires pathologist's interpretation when abnormal indices, atypical cells, or critical findings are identified. Real-time remote digital microscopy (DM) can potentially facilitate rapid review when an on-site pathologist is not availa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12914

    authors: Haninger DM,Nassiri M,Settembre ED,Zhang S,Zhou J

    更新日期:2018-12-01 00:00:00

  • Usefulness of automated fragmented red blood cell percentage in the diagnosis of paediatric haemolytic uraemic syndrome.

    abstract:INTRODUCTION:Presence of schistocytes in peripheral blood smear supporting haemolysis is important for diagnosis and decision-making in paediatric haemolytic uraemic syndrome (HUS). High observer dependency and requirement of expertise for peripheral smear evaluation propels us to think of other modalities to overcome ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13324

    authors: Govindarajan S,Bhatia P,Dawman L,Tiewsoh K

    更新日期:2021-02-01 00:00:00

  • Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer.

    abstract:INTRODUCTION:The Hematoflow (Beckman Coulter, USA) is a new automated hematology analyzer, which provides a 16-part white blood cell count (WBC) differential. METHODS:We evaluated the differential WBC count performance of the Hematoflow. 101 blood samples from patients were selected for comparison analysis. RESULTS:T...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01432.x

    authors: Kim JE,Kim BR,Woo KS,Han JY

    更新日期:2012-10-01 00:00:00

  • Signal transducer and activator of transcription 3 (STAT3) gene polymorphisms are associated with treatment outcomes in acute myeloid leukemia.

    abstract:INTRODUCTION:In the Janus kinase/signal transducer and activator of transcription (JAK/STAT) signaling pathway, STAT3 is one of the most prominent prognosis factors for cancer and leukemia. STAT3 activation might promote cellular transformation and therefore have an important role in human tumors. This study aimed to i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01406.x

    authors: Zhong Y,Feng J,Chen B,Cheng L,Li Y,Qian J,Ding J,Gao F,Xia G

    更新日期:2012-08-01 00:00:00

  • Multiplex fluorescence in situ hybridization in identifying chromosome involvement of complex karyotypes in de novo myelodysplastic syndromes and acute myeloid leukemia.

    abstract::Complex chromosomal aberrations (CCA) can be detected in a substantial proportion of myelodysplastic syndromes (MDS) and acute myeloid leukemia (AML), which are associated with very poor prognosis. Conventional cytogenetics (CC) cannot accurately define the specific alterations in CCA. Multiplex fluorescence in situ h...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01101.x

    authors: Xu W,Li JY,Liu Q,Zhu Y,Pan JL,Qiu HR,Xue YQ

    更新日期:2010-02-01 00:00:00

  • Red blood cell morphology.

    abstract::The foundation of laboratory hematologic diagnosis is the complete blood count and review of the peripheral smear. In patients with anemia, the peripheral smear permits interpretation of diagnostically significant red blood cell (RBC) findings. These include assessment of RBC shape, size, color, inclusions, and arrang...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12082

    authors: Ford J

    更新日期:2013-06-01 00:00:00

  • Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer.

    abstract:INTRODUCTION:We developed and validated reflex testing rules for the microscopic examination (ME) of body fluids (BFs) on the Sysmex XN-550 (Sysmex Corporation) instrument. METHODS:We assessed the detection limits, precision, linearity, and carryover. To develop the reflex testing rules (derivation arm), we tested 515...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12774

    authors: Cho YU,You E,Jang S,Park CJ

    更新日期:2018-06-01 00:00:00

  • Detection of malignant cells in serous body fluids by counting high-fluorescent cells on the Sysmex XN-2000 hematology analyzer.

    abstract:INTRODUCTION:The body fluid mode of the Sysmex XN-2000 hematology analyzer differentiates cells into mononuclear and polymorphonuclear white blood cells (WBC) and high-fluorescent cells (HFC). The aim of this study was to evaluate the performance of the HFC count for detecting malignant cells in serous body fluids. ME...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12393

    authors: Labaere D,Boeckx N,Geerts I,Moens M,Van den Driessche M

    更新日期:2015-10-01 00:00:00

  • Evaluation of the CellaVision DM automated microscope in pediatrics.

    abstract::The DM is an automated microscope, which performs WBC differential counts and monitors red cell morphology. The user either validates the cell recognition if the DM has correctly identified the WBCs or reclassifies the WBCs in the good category in case of a DM mis-assignment. Morphological anomalies of leukocytes, red...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01219.x

    authors: Billard M,Lainey E,Armoogum P,Alberti C,Fenneteau O,Da Costa L

    更新日期:2010-10-01 00:00:00

  • Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    abstract::The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were anal...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12083

    authors: Zantek ND,Hsu P,Refaai MA,Ledford-Kraemer M,Meijer P,Van Cott EM

    更新日期:2013-06-01 00:00:00

  • A study of disseminated intravascular coagulation in acute leukemia reveals markedly elevated D-dimer levels are a sensitive indicator of acute promyelocytic leukemia.

    abstract:INTRODUCTION:While the presence of disseminated intravascular coagulation (DIC) has been implicated in worse clinical outcome in acute leukemia, the relationship between different subtypes of acute leukemia and the clinicopathologic features of DIC has not been systematically well studied. METHODS:In this study, we re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12636

    authors: Shahmarvand N,Oak JS,Cascio MJ,Alcasid M,Goodman E,Medeiros BC,Arber DA,Zehnder JL,Ohgami RS

    更新日期:2017-08-01 00:00:00

  • Toward routine detection of extracellular vesicles in clinical samples.

    abstract::The majority, if not all, of human cell types secrete extracellular vesicles (EVs) into their environment, at least partly as a means of intercellular communication. These secreted vesicles can be detected in most bodily fluids including blood, urine, and saliva. The number of secreted vesicles and their composition i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12247

    authors: van der Meel R,Krawczyk-Durka M,van Solinge WW,Schiffelers RM

    更新日期:2014-06-01 00:00:00