Chronic active Epstein-Barr virus infection: A heterogeneous entity requiring a high index of suspicion for diagnosis.

Abstract:

:Chronic active Epstein-Barr virus infection of T- and NK-cell type, systemic form, is a rare entity within the spectrum of EBV-driven T- and NK-cell lymphoproliferative disorders. Established diagnostic criteria and a characteristic clinical course help to differentiate it from other closely related EBV-positive neoplasms and clinical states. We present a patient and review the natural history, pathologic features, pathogenesis, and differential diagnosis of this entity.

journal_name

Int J Lab Hematol

authors

Ondrejka SL,Hsi ED

doi

10.1111/ijlh.13199

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

99-106

eissn

1751-5521

issn

1751-553X

journal_volume

42 Suppl 1

pub_type

杂志文章,评审
  • Establishment of reference interval for immature platelet fraction.

    abstract:INTRODUCTION:Immature platelet fraction (IPF) is a parameter for reticulated platelets. A high percentage IPF (%-IPF) is indicative of consumptive or recovering thrombocytopenic disorders in contrast to a low %-IPF seen in aplastic states. Absolute IPF (A-IPF) specifically reflects the number of immature platelets in c...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12049

    authors: Ko YJ,Kim H,Hur M,Choi SG,Moon HW,Yun YM,Hong SN

    更新日期:2013-10-01 00:00:00

  • IgG subclasses of FVIII inhibitors in an argentine cohort of severe hemophilia A patients: Analysis by flow cytometry.

    abstract:INTRODUCTION:FVIII inhibitors consist of a polyclonal population of antibodies. Previous studies have demonstrated different distribution of IgG subclasses. IgG4 was associated to high level of FVIII inhibitors and failure of immune tolerance induction (ITI) treatment. This study monitored the relative distribution of ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12696

    authors: Irigoyen MB,Primiani L,Felippo M,Candela M,de Bracco MME,Galassi NV

    更新日期:2017-12-01 00:00:00

  • A study of disseminated intravascular coagulation in acute leukemia reveals markedly elevated D-dimer levels are a sensitive indicator of acute promyelocytic leukemia.

    abstract:INTRODUCTION:While the presence of disseminated intravascular coagulation (DIC) has been implicated in worse clinical outcome in acute leukemia, the relationship between different subtypes of acute leukemia and the clinicopathologic features of DIC has not been systematically well studied. METHODS:In this study, we re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12636

    authors: Shahmarvand N,Oak JS,Cascio MJ,Alcasid M,Goodman E,Medeiros BC,Arber DA,Zehnder JL,Ohgami RS

    更新日期:2017-08-01 00:00:00

  • Osmotic gradient ektacytometry: A valuable screening test for hereditary spherocytosis and other red blood cell membrane disorders.

    abstract:INTRODUCTION:New generation osmotic gradient ektacytometry has become a powerful procedure for measuring red blood cell deformability and therefore for the diagnosis of red blood cell membrane disorders. In this study, we aim to provide further support to the usefulness of osmotic gradient ektacytometry for the differe...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/ijlh.12746

    authors: Llaudet-Planas E,Vives-Corrons JL,Rizzuto V,Gómez-Ramírez P,Sevilla Navarro J,Coll Sibina MT,García-Bernal M,Ruiz Llobet A,Badell I,Velasco-Puyó P,Dapena JL,Mañú-Pereira MM

    更新日期:2018-02-01 00:00:00

  • Standardization of haematology critical results management in adults: an International Council for Standardization in Haematology, ICSH, survey and recommendations.

    abstract:INTRODUCTION:These recommendations are intended to develop a consensus in the previously published papers as to which parameters and what values should be considered critical. A practical guide on the standardization of critical results management in haematology laboratories would be beneficial as part of good laborato...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12526

    authors: Keng TB,De La Salle B,Bourner G,Merino A,Han JY,Kawai Y,Peng MT,McCafferty R,International Council for Standardization in Haematology (ICSH).

    更新日期:2016-10-01 00:00:00

  • Establishment of reference intervals for complete blood count parameters in venous blood for children in the Xiamen area, China.

    abstract:OBJECTIVES:To observe changes in the complete blood count (CBC) venous blood parameters of healthy children and establish appropriate reference intervals (RIs). METHODS:Overall, 4066 healthy children were selected and divided into four groups: infants, toddlers, preschool-age children and school-age children. Venous b...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13095

    authors: Li J,Zhang H,Huang X,Zhang J,Wu X

    更新日期:2019-10-01 00:00:00

  • The biological characteristics of dendritic cells derived in vitro from myelogeneous leukemia cells and healthy donor cells.

    abstract::Successful adoptive immunotherapy for leukemia depends on the generation of T cells that can specifically react with malignant cells. Dendritic cells (DCs) are important antigen-presenting cells in the development of antileukemia T-cell responses. Mononuclear cells (MNC) were isolated from peripheral blood or bone mar...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00986.x

    authors: Tong XM,Yao HP,Qian WB,Zhu LF,Fu ZH,Huang ZL,Jin J

    更新日期:2008-10-01 00:00:00

  • Case report of HbC/beta(0)-thalassemia from India.

    abstract::This 22-year-old women presented to the ante-natal clinic of this hospital for prenatal screening for beta-thalassemia. Cation exchange high performance liquid chromatography (HPLC) using 'Beta Thalassemia Short Program' on Bio-Rad 'Variant' system revealed HbC value of 81.6%. The CBC showed microcytic hypochromic ane...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00850.x

    authors: Kumar S,Rana M,Handoo A,Saxena R,Verma IC,Bhargava M,Sood SK

    更新日期:2007-10-01 00:00:00

  • 2016 WHO Classification update-What's new in lymphoid neoplasms.

    abstract::In the 8 years since the publication of the 4th edition of the WHO Classification of Hematopoietic and Lymphoid Tumours in 2008, there has been rapid accumulation of knowledge in the molecular genetics, biology, clinical behavior of many hematologic malignancies. Concepts and models have advanced to the point at which...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12650

    authors: Hsi ED

    更新日期:2017-05-01 00:00:00

  • The adsorption of dabigatran is as efficient as addition of idarucizumab to neutralize the drug in routine coagulation assays.

    abstract:INTRODUCTION:The direct thrombin inhibitor dabigatran interferes with thrombophilia screening and with the diagnosis of hemostasis disorders that develop during treatment with the anticoagulant. In vitro addition of idarucizumab, a humanized antibody fragment that binds dabigatran, to plasma samples containing dabigatr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12807

    authors: Jacquemin M,Toelen J,Feyen L,Schoeters J,Van Horenbeeck I,Vanlinthout I,Debasse M,Vanassche T,Peerlinck K,Verhamme P

    更新日期:2018-08-01 00:00:00

  • Development of a biochip-based assay integrated in a global strategy for identification of fusion transcripts in acute myeloid leukemia: a work flow for acute myeloid leukemia diagnosis.

    abstract::Three major types of rearrangements are involved in acute myeloid leukemias (AML): t(8;21)(q22;q22), inv(16)(p13q22), and 11q23/MLL abnormalities. Their precise identification becomes essential for diagnosis, prognosis, and therapeutic choices. Resulting fusion transcripts (FT) are also powerful markers for monitoring...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01201.x

    authors: Giusiano S,Formisano-Tréziny C,Benziane A,Maroc N,Picard C,Hermitte F,Taranger-Charpin C,Gabert J

    更新日期:2010-08-01 00:00:00

  • An investigation of the protective effect of alpha+-thalassaemia against severe Plasmodium falciparum amongst children in Kumasi, Ghana.

    abstract:INTRODUCTION:Several factors influence the severity of Plasmodium falciparum; here, we investigate the impact of alpha+-thalassaemia genotype on P. falciparum parasitemia and prevalence of severe anaemia amongst microcytic children from Kumasi, Ghana. METHODS:Seven hundred and thirty-two children (≤10 years) with P. f...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12122

    authors: Opoku-Okrah C,Gordge M,Kweku Nakua E,Abgenyega T,Parry M,Robertson C,Smith CL

    更新日期:2014-02-01 00:00:00

  • Acute myeloid leukaemia: How to combine multiple tools.

    abstract::The pathogenesis of acute myeloid leukaemias (AML) frequently requires at least 3 mutations in different cellular pathways. In many cases, mutations in proliferation/survival mechanisms and differentiation pathways are involved. Genetic aberrations explain the pathogenesis of AML, provide prognostic criteria and guide...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12831

    authors: Merino A,Boldú L,Ermens A

    更新日期:2018-05-01 00:00:00

  • Clotting and chromogenic factor VIII assay variability in post-infusion and spiked samples containing full-length recombinant FVIII or recombinant factor VIII Fc fusion protein (rFVIIIFc).

    abstract:INTRODUCTION:Variability in FVIII measurement is a recognized problem. There are limited data for samples containing recombinant Factor VIII Fc fusion protein (rFVIIIFc). Many studies use samples for which factor concentrate has been spiked into FVIII deficient plasma in vitro. This approach requires validation. AIM/M...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12940

    authors: Kitchen S,Jennings I,Makris M,Kitchen DP,Woods TAL,Walker ID

    更新日期:2019-04-01 00:00:00

  • Nontransferrin-bound iron in transfused patients with sickle cell disease.

    abstract::The value of nontransferrin-bound iron (NTBI) as an index of iron overload in patients with thalassemia has been evaluated; however, data in patients with sickle cell disease (SCD) is limited. NTBI levels were evaluated in a cross-sectional study of 43 transfused patients with SCD. Patient charts were reviewed for dem...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01224.x

    authors: Inati A,Musallam KM,Cappellini MD,Duca L,Taher AT

    更新日期:2011-04-01 00:00:00

  • International Council for Standardization in Haematology (ICSH) laboratory guidance for the evaluation of haemostasis analyser-reagent test systems. Part 1: Instrument-specific issues and commonly used coagulation screening tests.

    abstract::Before a new method is used for clinical testing, it is essential that it is evaluated for suitability for its intended purpose. This document gives guidance for the performance of verification, validation and implementation processes required by regulatory and accreditation bodies. It covers the planning and executio...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13411

    authors: Gardiner C,Coleman R,de Maat MPM,Dorgalaleh A,Echenagucia M,Gosselin RC,Ieko M,Kitchen S

    更新日期:2020-11-29 00:00:00

  • Establishment of reference intervals for pediatric complete capillary blood counts: A multicenter study in Beijing.

    abstract:INTRODUCTION:Clinical reference intervals represent the normal range of clinical parameters for distinguishing healthy and sick individuals, and they show some variation among different populations. Many reference intervals are still lacking for the pediatric population in China. Thus, the aim of this study was to esta...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13150

    authors: Sun Q,Yue Y,Tian Y,Wang Q

    更新日期:2020-10-01 00:00:00

  • Clinical and hematological characteristics of 88 patients with COVID-19.

    abstract:INTRODUCTION:To retrospectively analyze epidemiological, clinical and hematological characteristics of COVID-19 patients. METHODS:The demographic, symptoms, and physiological parameters of 88 patients were collected and analyzed. The performance of complete blood count (CBC) indexes for monitoring and predicting the s...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13291

    authors: Zhang H,Cao X,Kong M,Mao X,Huang L,He P,Pan S,Li J,Lu Z

    更新日期:2020-12-01 00:00:00

  • Platelet size has diagnostic predictive value for bone marrow metastasis in patients with solid tumors.

    abstract::Though not very common, solid tumor involvement of the bone marrow (BM) may have serious consequences. Recent studies have shown that mean platelet volume (MPV) is a good indicator for BM disease in the differential diagnosis of thrombocytopenia. We investigated the significance of MPV in the diagnosis of BM metastasi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00947.x

    authors: Aksoy S,Kilickap S,Hayran M,Harputluoglu H,Koca E,Dede DS,Erman M,Turker A

    更新日期:2008-06-01 00:00:00

  • Usefulness of automated fragmented red blood cell percentage in the diagnosis of paediatric haemolytic uraemic syndrome.

    abstract:INTRODUCTION:Presence of schistocytes in peripheral blood smear supporting haemolysis is important for diagnosis and decision-making in paediatric haemolytic uraemic syndrome (HUS). High observer dependency and requirement of expertise for peripheral smear evaluation propels us to think of other modalities to overcome ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13324

    authors: Govindarajan S,Bhatia P,Dawman L,Tiewsoh K

    更新日期:2021-02-01 00:00:00

  • Evaluation of amotosalem treated platelets over 7 days of storage with an automated cytometry assay panel.

    abstract:INTRODUCTION:Pathogen Inactivation allows to overcome microbial contamination and growth related to storage of platelets concentrates (PC) at room temperature. The aim of our study was to evaluate the platelet storage lesion extending the storage period of pathogen inactivated platelet concentrates over 7 days using an...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12102

    authors: Diquattro M,De Francisci G,Bonaccorso R,Tagliavia AM,Marcatti M,Palma B,Agliastro R

    更新日期:2013-12-01 00:00:00

  • Flow cytometry data analysis: Recent tools and algorithms.

    abstract::Flow cytometry (FCM) allows scientists to rapidly quantify up to 50 parameters for millions of cells per sample. The bottleneck in the application of the technology is data analysis, and the high number of parameters measured by the current generation of instruments requires the use of advanced computational algorithm...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13016

    authors: Montante S,Brinkman RR

    更新日期:2019-05-01 00:00:00

  • Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.

    abstract:INTRODUCTION:Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ijlh.13189

    authors: Sommer JM,Sadeghi-Khomami A,Barnowski C,Wikén M,Willemze AJ

    更新日期:2020-06-01 00:00:00

  • Paediatric reference intervals for common coagulation assays in Chinese children as performed on the STA-R coagulation analyzer.

    abstract:INTRODUCTION:In order to correctly manage the paediatric patients affected with haemostatic disorders, age-appropriate reference intervals should be used. The purpose of this study was to establish age-specific reference intervals for prothrombin time (PT), thrombin time (TT), activated partial thromboplastin time (aPT...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13098

    authors: Liu J,Dai Y,Yuan E,Li Y,Wang Q,Wang L,Su Y

    更新日期:2019-10-01 00:00:00

  • The mutual control of iron and erythropoiesis.

    abstract:BACKGROUND:Iron is essential for hemoglobin synthesis during terminal erythropoiesis. To supply adequate iron the carrier transferrin is required together with transferrin receptor endosomal cycle and normal mitochondrial iron utilization. Iron and iron protein deficiencies result in different types of anemia. Iron-def...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12505

    authors: Camaschella C,Pagani A,Nai A,Silvestri L

    更新日期:2016-05-01 00:00:00

  • Toward routine detection of extracellular vesicles in clinical samples.

    abstract::The majority, if not all, of human cell types secrete extracellular vesicles (EVs) into their environment, at least partly as a means of intercellular communication. These secreted vesicles can be detected in most bodily fluids including blood, urine, and saliva. The number of secreted vesicles and their composition i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12247

    authors: van der Meel R,Krawczyk-Durka M,van Solinge WW,Schiffelers RM

    更新日期:2014-06-01 00:00:00

  • Analytical comparison between two hematological analyzer systems: CAL-8000 vs. XN-9000.

    abstract:INTRODUCTION:This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL-8000 and XN-9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). METHODS:A total of 1025 peripheral blo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12597

    authors: Buoro S,Mecca T,Seghezzi M,Manenti B,Azzarà G,Dominoni P,Crippa A,Ottomano C,Lippi G

    更新日期:2017-04-01 00:00:00

  • Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

    abstract:INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12486

    authors: Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

    更新日期:2016-06-01 00:00:00

  • The automation of routine light transmission platelet aggregation.

    abstract:INTRODUCTION:The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS:We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12161

    authors: Lawrie AS,Kobayashi K,Lane PJ,Mackie IJ,Machin SJ

    更新日期:2014-08-01 00:00:00

  • Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers.

    abstract::Modern photo-optical coagulometers collect optical data in the form of reaction curves and offer a possibility to determine clotting times at different points of clot formation by using different evaluation modes. The objectives of this study were to determine the possible impact of an evaluation mode on activated par...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01111.x

    authors: Milos M,Herak DC,Zadro R

    更新日期:2010-02-01 00:00:00