Common wearable devices demonstrate variable accuracy in measuring heart rate during supraventricular tachycardia.

Abstract:

BACKGROUND:Wearable devices are used as a noninvasive method of monitoring health. The accuracy of wearables for heart rate (HR) monitoring has been extensively studied in sinus rhythm, but evidence for tachyarrhythmias, particularly supraventricular tachycardia (SVT), is sparse. OBJECTIVE:The purpose of this study was to examine the accuracy of 4 common wearable devices-Apple Watch, Fitbit Charge HR, Garmin VivoSmart HR, and Polar A360-in measuring HR during paroxysmal SVT. METHODS:Data were gathered from 52 patients by placing 1 device on each wrist during an electrophysiological study at which SVT was induced. The device-measured HR was obtained by using the highest HR measured by the device during each SVT episode. This HR was compared with measurements from a 12-lead electrocardiogram (ECG), for which the rate during the last 5 seconds of SVT was averaged. RESULTS:For SVT episodes <15 seconds, the Apple, Fitbit, Garmin, and Polar devices registered an increase from baseline HR in 18.7%, 19.5%, 1.5%, and 37.7% of episodes, respectively. For episodes 15-60 seconds, the Apple, Fitbit, Garmin, and Polar devices registered an increase in 67.6%, 42.4%, 24.3%, and 65.5% of episodes, respectively. For episodes ≥60 seconds, the Apple and Polar devices had 23 of 23 and 19 of 21 episodes with at least 90% agreement between device-measured and ECG-measured HR, whereas the Fitbit and Garmin devices had 7 of 20 and 8 of 22 episodes with at least 90% agreement. CONCLUSION:All wearable devices are inaccurate for short-duration SVT. Some devices are accurate for longer duration SVT.

journal_name

Heart Rhythm

journal_title

Heart rhythm

authors

Sequeira N,D'Souza D,Angaran P,Aves T,Dorian P

doi

10.1016/j.hrthm.2020.02.018

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

854-859

issue

5 Pt B

eissn

1547-5271

issn

1556-3871

pii

S1547-5271(20)30120-X

journal_volume

17

pub_type

杂志文章
  • Atrial Fibrillation is an Independent Predictor for In-hospital Mortality in Patients Admitted with SARS-CoV-2 Infection.

    abstract:BACKGROUND:Atrial fibrillation (AF) is the most encountered arrhythmia and has been associated with worse in-hospital outcomes. OBJECTIVE:To determine the incidence of AF among patients hospitalized with COVID-19 as well as its impact on in-hospital mortality. METHODS:Patients hospitalized with a positive COVID-19 po...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2021.01.018

    authors: Mountantonakis SE,Saleh M,Fishbein J,Gandomi A,Lesser M,Chelico J,Gabriels J,Qiu M,Epstein LM,Northwell COVID-19 Research Consortium.

    更新日期:2021-01-22 00:00:00

  • Autonomic regulation therapy suppresses quantitative T-wave alternans and improves baroreflex sensitivity in patients with heart failure enrolled in the ANTHEM-HF study.

    abstract:BACKGROUND:Autonomic regulation therapy (ART) with chronic vagus nerve stimulation improves ventricular function in patients with chronic heart failure, but its effects on quantitative T-wave alternans (TWA), ventricular tachycardia (VT), baroreflex sensitivity, and autonomic tone remained unknown. OBJECTIVE:Effects o...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.hrthm.2015.11.030

    authors: Libbus I,Nearing BD,Amurthur B,KenKnight BH,Verrier RL

    更新日期:2016-03-01 00:00:00

  • Electrophysiologic substrate and intraventricular left ventricular dyssynchrony in nonischemic heart failure patients undergoing cardiac resynchronization therapy.

    abstract:BACKGROUND:Electrocardiographic imaging (ECGI) is a method for noninvasive epicardial electrophysiologic mapping. ECGI previously has been used to characterize the electrophysiologic substrate and electrical synchrony in a very heterogeneous group of patients with varying degrees of coronary disease and ischemic cardio...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2011.01.017

    authors: Ghosh S,Silva JN,Canham RM,Bowman TM,Zhang J,Rhee EK,Woodard PK,Rudy Y

    更新日期:2011-05-01 00:00:00

  • Transvenous extraction of implantable cardioverter-defibrillator leads under advisory--a comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads.

    abstract:BACKGROUND:Comparative safety and efficacy associated with transvenous lead extraction (TLE) of recalled and non-recalled implantable cardioverter-defibrillator (ICD) leads has not been well characterized. OBJECTIVES:To compare the indications, techniques, and procedural outcomes of recalled vs non-recalled ICD lead e...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2013.06.021

    authors: Brunner MP,Cronin EM,Jacob J,Duarte VE,Tarakji KG,Martin DO,Callahan T,Borek PP,Cantillon DJ,Niebauer MJ,Saliba WI,Kanj M,Wazni O,Baranowski B,Wilkoff BL

    更新日期:2013-10-01 00:00:00

  • Fungal infection of implantable cardioverter-defibrillators: case series of five patients managed over 22 years.

    abstract:BACKGROUND:With the increasing use of implantable cardioverter-defibrillators (ICDs), device complications are becoming more common. Fungal-related ICD infections have rarely been reported, and little is known about the presentation, prevalence, and treatment options for these morbid infections. OBJECTIVES:The purpose...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2006.04.012

    authors: Ho IC,Milan DJ,Mansour MC,Mela T,Guy ML,Ruskin JN,Ellinor PT

    更新日期:2006-08-01 00:00:00

  • Complications arising from catheter ablation of atrial fibrillation: temporal trends and predictors.

    abstract:BACKGROUND:The reported complication rate of catheter ablation of atrial fibrillation (AF) varies. OBJECTIVE:Our goal was to assess temporal trends and the effect of both institutional and individual operators' experience on the incidence of complications. METHODS:All patients undergoing AF ablation at Johns Hopkins ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2011.07.025

    authors: Hoyt H,Bhonsale A,Chilukuri K,Alhumaid F,Needleman M,Edwards D,Govil A,Nazarian S,Cheng A,Henrikson CA,Sinha S,Marine JE,Berger R,Calkins H,Spragg DD

    更新日期:2011-12-01 00:00:00

  • A common missense variant in the neuregulin 1 gene is associated with both schizophrenia and sudden cardiac death.

    abstract:BACKGROUND:Both schizophrenia and epilepsy have been linked to increased risk of sudden cardiac death (SCD). We hypothesized that DNA variants within genes previously associated with schizophrenia and epilepsy may contribute to an increased risk of SCD. OBJECTIVE:To investigate the contribution to SCD susceptibility o...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.hrthm.2013.03.020

    authors: Huertas-Vazquez A,Teodorescu C,Reinier K,Uy-Evanado A,Chugh H,Jerger K,Ayala J,Gunson K,Jui J,Newton-Cheh C,Albert CM,Chugh SS

    更新日期:2013-07-01 00:00:00

  • A retrospective analysis of proceduralist-directed, nurse-administered propofol sedation for implantable cardioverter-defibrillator procedures.

    abstract:BACKGROUND:There is controversy whether proceduralist-directed, nurse-administered propofol sedation (PDNAPS) is safe. OBJECTIVE:To assess the frequency of adverse events when PDNAPS is used for implantable cardioverter-defibrillator (ICD)-related procedures and to determine the patient and procedural characteristics ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2011.10.009

    authors: Sayfo S,Vakil KP,Alqaqa'a A,Flippin H,Bhakta D,Yadav AV,Miller JM,Groh WJ

    更新日期:2012-03-01 00:00:00

  • Incidence of pulmonary vein conduction recovery in patients without clinical recurrence after ablation of paroxysmal atrial fibrillation: mechanistic implications.

    abstract:BACKGROUND:Pulmonary vein (PV) isolation has become the mainstay acute procedural end point for paroxysmal atrial fibrillation (AF) ablation. OBJECTIVE:To examine the incidence of conduction recovery in the PVs in patients without clinical recurrence of AF after paroxysmal AF ablation. METHODS:From August 2008 to Mar...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2014.03.015

    authors: Jiang RH,Po SS,Tung R,Liu Q,Sheng X,Zhang ZW,Sun YX,Yu L,Zhang P,Fu GS,Jiang CY

    更新日期:2014-06-01 00:00:00

  • QRS narrowing is associated with reverse remodeling in patients with chronic right ventricular pacing upgraded to cardiac resynchronization therapy.

    abstract:BACKGROUND:Patients with chronic right ventricular pacing (RVP) upgraded to cardiac resynchronization therapy (CRT) have been excluded from the majority of clinical trials of CRT. Little is known about the predictors of response in this population. We hypothesized that reversal of RVP-induced electrical dyssynchrony (i...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2012.09.018

    authors: Rickard J,Cheng A,Spragg D,Cantillon D,Chung MK,Tang WH,Wilkoff BL,Varma N

    更新日期:2013-01-01 00:00:00

  • Focal impulse and rotor modulation as a stand-alone procedure for the treatment of paroxysmal atrial fibrillation: A within-patient controlled study with implanted cardiac monitoring.

    abstract:BACKGROUND:Focal impulse and rotor modulation (FIRM) has been proposed as a novel approach for the treatment of atrial fibrillation (AF). OBJECTIVE:This study aimed to investigate the efficacy of FIRM as a stand-alone procedure for the treatment of paroxysmal AF. METHODS:A total of 27 patients with paroxysmal AF unde...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2016.04.016

    authors: Berntsen RF,Håland TF,Skårdal R,Holm T

    更新日期:2016-09-01 00:00:00

  • Differential diagnosis of regular, narrow-QRS tachycardias.

    abstract::We present an update on clinical and electrophysiological criteria used for the differential diagnosis of regular supraventricular tachycardias. Although several electrocardiographic clues may assist in the differential diagnosis, this is usually accomplished at electrophysiology study, and most often, the differentia...

    journal_title:Heart rhythm

    pub_type: 杂志文章,评审

    doi:10.1016/j.hrthm.2015.03.046

    authors: Katritsis DG,Josephson ME

    更新日期:2015-07-01 00:00:00

  • Distinctive property and pharmacology of voltage-gated sodium current in rat atrial vs ventricular myocytes.

    abstract:BACKGROUND:Several mammalian species display distinct biophysical properties between atrial and ventricular voltage-gated sodium current (INa); however, the potential mechanism behind this phenomenon is unknown. OBJECTIVE:The purpose of this study was to investigate the potential molecular identities of the different ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2015.11.022

    authors: Chen KH,Xu XH,Sun HY,Du XL,Liu H,Yang L,Xiao GS,Wang Y,Jin MW,Li GR

    更新日期:2016-03-01 00:00:00

  • Temporary autonomic modulation with botulinum toxin type A to reduce atrial fibrillation after cardiac surgery.

    abstract:BACKGROUND:Postoperative atrial fibrillation (POAF) frequently complicates cardiac surgery and is associated with worse outcomes. The cardiac autonomic nervous system is implicated in the pathogenesis of POAF. OBJECTIVE:The purpose of this study was to determine the efficacy and safety of selective cardiac autonomic m...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.hrthm.2018.08.021

    authors: Waldron NH,Cooter M,Haney JC,Schroder JN,Gaca JG,Lin SS,Sigurdsson MI,Fudim M,Podgoreanu MV,Stafford-Smith M,Milano CA,Piccini JP,Mathew JP

    更新日期:2019-02-01 00:00:00

  • High resistance of atrioventricular node to cryoablation: a great safety margin targeting perinodal arrhythmic substrates.

    abstract:BACKGROUND:Findings from animal studies and small series of patients support the greater safety of cryoenergy over radiofrequency in the ablation of arrhythmic substrates near the AV node. OBJECTIVES:The purpose of this study was to systematically evaluate the electrophysiologic effects of successive cryoenergy applic...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2006.06.002

    authors: Pérez-Castellano N,Villacastín J,Moreno J,Isa R,Ruiz E,Doblado M,Moreno M,Morales R,Macaya C

    更新日期:2006-10-01 00:00:00

  • Nonspecific intraventricular conduction delay: Definitions, prognosis, and implications for cardiac resynchronization therapy.

    abstract::Cardiac resynchronization therapy (CRT) is an electrical treatment of heart failure with reduced ejection fraction and wide QRS. It aims to correct the electrical dyssynchrony present in 30% to 50% of patients in this population. Dyssynchrony results in widening of the QRS complex on the electrocardiogram (ECG). CRT w...

    journal_title:Heart rhythm

    pub_type: 杂志文章,评审

    doi:10.1016/j.hrthm.2015.01.023

    authors: Eschalier R,Ploux S,Ritter P,Haïssaguerre M,Ellenbogen KA,Bordachar P

    更新日期:2015-05-01 00:00:00

  • Ablation for longstanding permanent atrial fibrillation: results from a randomized study comparing three different strategies.

    abstract:BACKGROUND:This prospective multicenter randomized study aimed to compare the efficacy of 3 common ablation methods used for longstanding permanent atrial fibrillation (AF). METHODS:A total of 144 patients with longstanding permanent AF (median duration 28 months) were randomly assigned to circumferential pulmonary ve...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.hrthm.2008.09.016

    authors: Elayi CS,Verma A,Di Biase L,Ching CK,Patel D,Barrett C,Martin D,Rong B,Fahmy TS,Khaykin Y,Hongo R,Hao S,Pelargonio G,Dello Russo A,Casella M,Santarelli P,Potenza D,Fanelli R,Massaro R,Arruda M,Schweikert RA,Nata

    更新日期:2008-12-01 00:00:00

  • The effect of reverse remodeling on long-term survival in mildly symptomatic patients with heart failure receiving cardiac resynchronization therapy: results of the REVERSE study.

    abstract:BACKGROUND:Cardiac resynchronization therapy (CRT) reduces mortality, improves functional status, and induces reverse left ventricular remodeling in selected populations with heart failure (HF). The magnitude of reverse remodeling predicts survival with many HF medical therapies. However, there are few studies assessin...

    journal_title:Heart rhythm

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1016/j.hrthm.2014.11.014

    authors: Gold MR,Daubert C,Abraham WT,Ghio S,St John Sutton M,Hudnall JH,Cerkvenik J,Linde C

    更新日期:2015-03-01 00:00:00

  • Radiofrequency ablation of atrial fibrillation under therapeutic international normalized ratio: a safe and efficacious periprocedural anticoagulation strategy.

    abstract:BACKGROUND:The best periprocedural anticoagulation strategy at the time of pulmonary vein isolation (PVI) is not known. Most centers stop administering warfarin (Coumadin) and use bridging with heparin or enoxaparin. OBJECTIVE:The purpose of this study was to evaluate the efficacy and safety of PVI under therapeutic i...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2009.07.007

    authors: Hussein AA,Martin DO,Saliba W,Patel D,Karim S,Batal O,Banna M,Williams-Andrews M,Sherman M,Kanj M,Bhargava M,Dresing T,Callahan T,Tchou P,Di Biase L,Beheiry S,Lindsay B,Natale A,Wazni O

    更新日期:2009-10-01 00:00:00

  • Unmasking atrial repolarization to assess alternans, spatiotemporal heterogeneity, and susceptibility to atrial fibrillation.

    abstract:BACKGROUND:Detection of atrial repolarization waves free of far-field signal contamination by ventricular activation would allow investigation of atrial electrophysiology and factors that influence susceptibility to atrial tachycardia and atrial fibrillation (AF). OBJECTIVE:The purpose of this study was to identify me...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2015.11.019

    authors: Verrier RL,Fuller H,Justo F,Nearing BD,Rajamani S,Belardinelli L

    更新日期:2016-04-01 00:00:00

  • Antitachycardia pacing for reduction of implantable cardioverter-defibrillator shocks.

    abstract::Antitachycardia pacing (ATP) strategies represent safe, effective, and painless therapy for ventricular tachyarrhythmias, with a large body of clinical evidence supporting their routine use in both primary and secondary implantable cardioverter-defibrillator recipients. This article details the evidence supporting the...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2015.02.024

    authors: Cantillon DJ,Wilkoff BL

    更新日期:2015-06-01 00:00:00

  • Determination of myocardial infarct size by noncontact mapping.

    abstract:BACKGROUND:Once chamber geometry is determined, the EnSite 3000 noncontact mapping system can create a voltage map during a single cardiac cycle. The EnSite uses an inverse solution to the Laplace equation to process the amplified far-field signals from the noncontact catheter. This process creates a three-dimensional ...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2007.10.026

    authors: Voss F,Steen H,Bauer A,Giannitsis E,Katus HA,Becker R

    更新日期:2008-02-01 00:00:00

  • Catheter ablation of polymorphic ventricular tachycardia/fibrillation in patients with and without structural heart disease.

    abstract:BACKGROUND:Catheter ablation for polymorphic ventricular tachycardia and ventricular fibrillation (PMVT/VF) may target triggering premature ventricular contractions (PVCs). Targeting ventricular scar has also been suggested, but data are limited. OBJECTIVE:The purpose of this study was to characterize the electrophysi...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2019.01.032

    authors: Nakamura T,Schaeffer B,Tanigawa S,Muthalaly RG,John RM,Michaud GF,Tedrow UB,Stevenson WG

    更新日期:2019-07-01 00:00:00

  • Biventricular pacing does not affect microvolt T-wave alternans in heart failure patients.

    abstract:BACKGROUND:Microvolt T-wave alternans (MTWA) is a valuable tool for stratification of patients at risk for sudden death and has recently been approved for this purpose by Medicare. Although right atrial (RA) pacing has been applied for MTWA testing, the effects of other pacing modalities on MTWA have not been systemati...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2007.10.032

    authors: Ehrlich JR,Wegener FT,Anneken L,Duray G,Israel CW,Hohnloser SH

    更新日期:2008-03-01 00:00:00

  • Subclavian venoplasty by the implanting physicians in 373 patients over 11 years.

    abstract:BACKGROUND:The need to add a lead(s) despite subclavian/innominate obstruction is increasing. Subclavian venoplasty may be a good alternative to the commonly employed options; however, there are few reports in the literature, and all are by interventional radiologists. OBJECTIVE:To describe the procedural details, res...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2010.12.014

    authors: Worley SJ,Gohn DC,Pulliam RW,Raifsnider MA,Ebersole BI,Tuzi J

    更新日期:2011-04-01 00:00:00

  • Time until diagnosis of clinical events with different remote monitoring systems in implantable cardioverter-defibrillator patients.

    abstract:BACKGROUND:Remote monitoring (RM) is an established technology integrated into routine follow-up of patients with an implantable cardioverter-defibrillator (ICD). Current RM systems differ according to transmission frequency and alert definition. OBJECTIVE:The purpose of this study was to compare the time difference b...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2018.05.025

    authors: Söth-Hansen M,Witt CT,Rasmussen M,Kristensen J,Gerdes C,Nielsen JC

    更新日期:2018-11-01 00:00:00

  • Ten-year ablation outcomes of patients with paroxysmal atrial fibrillation undergoing pulmonary vein isolation.

    abstract:BACKGROUND:Pulmonary vein isolation (PVI) is commonly performed in patients with drug-refractory symptomatic paroxysmal atrial fibrillation (PAF). However, the very long-term follow-up result is limited. OBJECTIVE:We aimed to investigate 10-year ablation outcomes in patients with PAF and long-term follow-up results af...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2019.03.028

    authors: Cheng WH,Lo LW,Lin YJ,Chang SL,Hu YF,Hung Y,Chung FP,Liao JN,Tuan TC,Chao TF,Tsai TY,Liu SH,Chen SA

    更新日期:2019-09-01 00:00:00

  • Electrophysiologic delineation of the tachycardia circuit in the slow-slow form of atrioventricular nodal reentrant tachycardia.

    abstract:BACKGROUND:Little is known about the exact boundaries of the reentrant circuit in the slow-slow form of atrioventricular nodal reentrant tachycardia (AVNRT). OBJECTIVE:The purpose of this study was to examine the tachycardia circuit in the slow-slow form of AVNRT. METHODS:Single extrastimuli were delivered during the...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2007.02.010

    authors: Yamabe H,Tanaka Y,Morihisa K,Uemura T,Kawano H,Nagayoshi Y,Kojima S,Ogawa H

    更新日期:2007-06-01 00:00:00

  • Effect of ranolazine on ventricular repolarization in class III antiarrhythmic drug-treated rabbits.

    abstract:BACKGROUND:Ranolazine exhibits a synergistic effect in combination with class III drugs to suppress atrial fibrillation. OBJECTIVE:To investigate whether a combination therapy affects repolarization and provokes ventricular tachyarrhythmias (VT) in a sensitive model of proarrhythmia. METHODS:Thirty-seven rabbits were...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2012.08.029

    authors: Frommeyer G,Kaiser D,Uphaus T,Kaese S,Osada N,Rajamani S,Belardinelli L,Breithardt G,Eckardt L,Milberg P

    更新日期:2012-12-01 00:00:00

  • Follow-up imaging after left atrial appendage closure.

    abstract:BACKGROUND:Because device-related thrombus (DRT) portends a poor prognosis after left atrial appendage closure with the Watchman device, surveillance transesophageal echocardiography (TEE) is recommended at 45 days and 1 year. However, oral anticoagulants are just discontinued at 45 days, rendering this early TEE unlik...

    journal_title:Heart rhythm

    pub_type: 杂志文章

    doi:10.1016/j.hrthm.2020.06.024

    authors: Kuroki K,Doshi SK,Whang W,Vanderzee S,Ducharme CB,Enomoto Y,Hanon S,Koruth JS,Miller MA,Choudry S,Sofi A,Langan N,Ellsworth B,Dukkipati SR,Reddy VY

    更新日期:2020-11-01 00:00:00