Paediatric reference intervals for common coagulation assays in Chinese children as performed on the STA-R coagulation analyzer.

Abstract:

INTRODUCTION:In order to correctly manage the paediatric patients affected with haemostatic disorders, age-appropriate reference intervals should be used. The purpose of this study was to establish age-specific reference intervals for prothrombin time (PT), thrombin time (TT), activated partial thromboplastin time (aPTT) and fibrinogen (Fg). METHODS:In this study, a total of 34 234 apparently healthy children and adolescents aged 0-15 years were chosen as reference individuals. PT, TT, aPTT and Fg were performed on the STA-R coagulation analyzer. Outliers were eliminated using the Dixon D/R ratio rule. Partitioning by age was achieved using Harris and Boyd's standard normal deviate test. The lower (2.5th percentiles) and upper (97.5 percentiles) reference intervals were established using the nonparametric method. RESULTS:Compared with the adult group, the median time of PT was significantly different in the groups consisting of children aged 0-15 days, 15 days-1 month, 1-6 months and 11-15 years. The median time of APTT and TT was significantly prolonged in all paediatric age groups than in the adult group (P < .05). Compared with the adult group, the median values of Fg were significantly different in the groups consisting of children aged 0-15 days and 2-15 years. Our results showed that all coagulation assays required partitioning by age. CONCLUSION:Our results suggest that results of coagulation assays are highly dependent on age, and that age-specific reference intervals must be used to ensure proper evaluation of paediatric coagulation assays.

journal_name

Int J Lab Hematol

authors

Liu J,Dai Y,Yuan E,Li Y,Wang Q,Wang L,Su Y

doi

10.1111/ijlh.13098

subject

Has Abstract

pub_date

2019-10-01 00:00:00

pages

697-701

issue

5

eissn

1751-5521

issn

1751-553X

journal_volume

41

pub_type

杂志文章
  • Lack of harmonization in high fluorescent cell automated counts with body fluids mode in ascitic, pleural, synovial, and cerebrospinal fluids.

    abstract:INTRODUCTION:Cellular analysis in body fluids (BFs) provides important diagnostic information in various pathological settings. This study was hence aimed at comparing automated cell count obtained with Mindray BC-6800 (BC-BF) vs Sysmex XN-series (XN-BF) and evaluating other quantitative and qualitative information pro...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12968

    authors: Buoro S,Seghezzi M,Dominoni P,Moioli V,Manenti B,Previtali G,Ottomano C,Lippi G

    更新日期:2019-04-01 00:00:00

  • Establishment of reference intervals for pediatric complete capillary blood counts: A multicenter study in Beijing.

    abstract:INTRODUCTION:Clinical reference intervals represent the normal range of clinical parameters for distinguishing healthy and sick individuals, and they show some variation among different populations. Many reference intervals are still lacking for the pediatric population in China. Thus, the aim of this study was to esta...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13150

    authors: Sun Q,Yue Y,Tian Y,Wang Q

    更新日期:2020-10-01 00:00:00

  • Association of mean platelet volume and platelet count with the development and prognosis of ischemic and hemorrhagic stroke.

    abstract:INTRODUCTION:Mean platelet volume (MPV) and platelet (PLT) count are the two major parameters that reflect the functions and activities of PLTs. The associations of MPV and PLT count with the occurrence and prognosis of stroke have not been fully clarified. This study aimed to investigate the association of MPV and PLT...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/ijlh.12474

    authors: Du J,Wang Q,He B,Liu P,Chen JY,Quan H,Ma X

    更新日期:2016-06-01 00:00:00

  • Evaluation of the CellaVision DM automated microscope in pediatrics.

    abstract::The DM is an automated microscope, which performs WBC differential counts and monitors red cell morphology. The user either validates the cell recognition if the DM has correctly identified the WBCs or reclassifies the WBCs in the good category in case of a DM mis-assignment. Morphological anomalies of leukocytes, red...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01219.x

    authors: Billard M,Lainey E,Armoogum P,Alberti C,Fenneteau O,Da Costa L

    更新日期:2010-10-01 00:00:00

  • How I investigate Eosinophilia.

    abstract::Eosinophilia is typically secondary, that is, reactive, in nature and is associated with a wide variety of neoplastic and non-neoplastic disorders. Clonal eosinophilia is also seen in a wide variety of hematopoietic neoplasms, and sub-classification can be diagnostically challenging. A proper evaluation of persistent ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12955

    authors: Larsen RL,Savage NM

    更新日期:2019-04-01 00:00:00

  • The HemoScreen hematology point-of-care device is suitable for rapid evaluation of acute leukemia patients.

    abstract:BACKGROUND:Hematological patients, receiving intensive chemotherapy (predominantly acute leukemia patients), have repeated postchemotherapy periods with severe bone marrow suppression. As a result, these patients require regular monitoring of the complete blood counts (CBC) for optimal patient care. To reduce the strai...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13330

    authors: Kristian Kur D,Thøgersen D,Kjeldsen L,Friis-Hansen L

    更新日期:2021-02-01 00:00:00

  • Evaluation of small-volume tubes for venous and capillary PT (INR) samples.

    abstract:INTRODUCTION:Frequent PT (INR) testing may represent a problem for patients on warfarin treatment, and capillary or small-volume tubes may be more appropriate for such patients. A demand for small-volume tubes also comes from pediatric wards. Yet, while various small-volume tubes are available, they have not been prope...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12387

    authors: Onelöv L,Basmaji R,Svensson A,Nilsson M,Antovic JP

    更新日期:2015-10-01 00:00:00

  • Multiplex fluorescence in situ hybridization in identifying chromosome involvement of complex karyotypes in de novo myelodysplastic syndromes and acute myeloid leukemia.

    abstract::Complex chromosomal aberrations (CCA) can be detected in a substantial proportion of myelodysplastic syndromes (MDS) and acute myeloid leukemia (AML), which are associated with very poor prognosis. Conventional cytogenetics (CC) cannot accurately define the specific alterations in CCA. Multiplex fluorescence in situ h...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01101.x

    authors: Xu W,Li JY,Liu Q,Zhu Y,Pan JL,Qiu HR,Xue YQ

    更新日期:2010-02-01 00:00:00

  • Entonox as a sedative for bone marrow aspiration and biopsy.

    abstract::Bone marrow aspiration and biopsy can be a painful procedure. Sedation techniques may make this investigation more acceptable to patients, but have the potential to cause life-threatening complications, as well as requiring additional staff and equipment for safe administration. We assessed the use of Entonox, a 50 : ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1751-553X.2007.00905.x

    authors: Gudgin EJ,Besser MW,Craig JI

    更新日期:2008-02-01 00:00:00

  • Abrogation of red blood cell G6PD enzyme activity through Heat treatment: development of survey material for the UK NEQAS G6PD scheme.

    abstract:INTRODUCTION:Participation in external quality assessment (EQA) is central to the maintenance of high-quality laboratory results in patient diagnosis and clinical trials. Laboratories in the TAF112582 DETECTIVE study (ClinicalTrials.gov identifier: NCT01376167) are enrolled in the United Kingdom National Quality Assess...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12627

    authors: Roper DR,De la Salle B,Soni V,Fletcher K,Green JA

    更新日期:2017-06-01 00:00:00

  • Iron status determination in pregnancy using the Thomas plot.

    abstract:INTRODUCTION:Physiological changes during pregnancy affect routine tests for iron deficiency. The reticulocyte haemoglobin equivalent (RET-He) and serum-soluble transferrin receptor (sTfR) assay are newer diagnostic parameters for the detection of iron deficiency, combined in the Thomas diagnostic plot. We used this pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12448

    authors: Weyers R,Coetzee MJ,Nel M

    更新日期:2016-04-01 00:00:00

  • Inappropriate use of protein C, protein S, and antithrombin testing for hereditary thrombophilia screening: an experience from a large university hospital.

    abstract:INTRODUCTION:Deficiencies of protein C, protein S, and antithrombin are the main inherited risk factors in Thai patients with venous thromboembolism, although the prevalence is not high. METHODS:To evaluate the appropriate use of the testing for these proteins, the test orders of 503 patients were retrospectively revi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01332.x

    authors: Tientadakul P,Chinthammitr Y,Sanpakit K,Wongwanit C,Nilanont Y

    更新日期:2011-12-01 00:00:00

  • Paroxysmal nocturnal haemoglobinuria. Experience over a 10 years period.

    abstract:INTRODUCTION:Paroxysmal nocturnal hemoglobinuria (PNH) is a hemolytic, clonal and acquired disorder of the hematopoietic stem cell with a deficiency of all glycophosphatidyl-inositol (GPI) linked proteins. The aim of this retrospective study was to analyse haematological and biochemical data from 152 patients referred ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12156

    authors: Canalejo K,Riera Cervantes N,Felippo M,Sarandría C,Aixalá M

    更新日期:2014-04-01 00:00:00

  • Strategies for basic laboratory diagnostics of the hemoglobinopathies in multi-ethnic societies: interpretation of results and pitfalls.

    abstract::The consistent multi-ethnic migrations of the last decades have considerably changed the epidemiology of the hemoglobinopathies. Healthy carriers of these conditions are present today in many nonendemic parts of the world, and severely affected children are now born where these diseases were previously rare or unknown...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12037

    authors: Giordano PC

    更新日期:2013-10-01 00:00:00

  • A level-headed approach to measuring direct oral anticoagulants: A 2-year retrospective analysis of DOAC levels from a tertiary UK centre.

    abstract:INTRODUCTION:Direct oral anticoagulants (DOAC) are commonly prescribed and measuring drug levels may be useful in a number of contexts. However, data on DOAC level measurement and their clinical utility in real-world studies are limited. METHODS:We carried out a 2-year retrospective cohort study of DOAC levels measure...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12944

    authors: Denny NDR,Keighley L,Siganporia Z,Thachil J,Nash MJ

    更新日期:2019-04-01 00:00:00

  • The impact of long-haul air travel on variables of the athlete's biological passport.

    abstract:INTRODUCTION:Dehydration, fluid shifts or changes in coagulation occurring during air travel can trigger distinct reactions in the haematological system. Athletes are concerned that these effects might impair sporting performance, increase the risk of thrombosis or cause abnormalities in blood values that might be mist...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01450.x

    authors: Schumacher YO,Klodt F,Nonis D,Pottgiesser T,Alsayrafi M,Bourdon PC,Voss SC

    更新日期:2012-12-01 00:00:00

  • Acquired haemophilia masked by warfarin therapy.

    abstract::Acquired haemophilia is a rare phenomenon and prompt diagnosis is essential for successful treatment. Early laboratory detection could minimize its potentially devastating consequences and reduce mortality but when a masking element such as anticoagulant therapy is present, delay in diagnosis is not uncommon. A prolon...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00867.x

    authors: Vadikolia CM,Riddell A,Brooks S,Yee TT,Brown S,Lee C

    更新日期:2007-02-01 00:00:00

  • A hierarchical approach in the diagnostic workflow of chronic myelomonocytic leukemia: Pivotal role of the "Mono-dysplasia-score" combined with flow cytometric quantification of monocyte subsets.

    abstract:INTRODUCTION:Monocytosis is a frequent trigger for blood smear review in a routine hematology laboratory whereas chronic myelomonocytic leukemia (CMML) is infrequent and arises mostly in elderly patients. In order to define the best workflow for monocytosis, we studied three diagnostic approaches: the classical morphol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13115

    authors: Zhu J,Sourdeau E,Aubert H,Clauser S,Maillon A,Capron C,Jondeau K,Ronez E,Schillinger F,Garnache-Ottou F,Cornet E,Bardet V

    更新日期:2019-12-01 00:00:00

  • Analytical comparison between two hematological analyzer systems: CAL-8000 vs. XN-9000.

    abstract:INTRODUCTION:This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL-8000 and XN-9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). METHODS:A total of 1025 peripheral blo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12597

    authors: Buoro S,Mecca T,Seghezzi M,Manenti B,Azzarà G,Dominoni P,Crippa A,Ottomano C,Lippi G

    更新日期:2017-04-01 00:00:00

  • CD34, RAB20, PU.1 and GFI1 mRNA expression in myelodysplastic syndrome.

    abstract::Myelodysplastic syndrome (MDS) with hypocellular bone marrow (BM) is often difficult to distinguish from aplastic anemia (AA). Furthermore, the diagnosis of MDS with low blast counts and normal karyotype may be problematic. These issues highlight the need for a reliable marker for the diagnosis of MDS. This study was ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01056.x

    authors: Huh HJ,Chae SL,Lee M,Hong KS,Mun YC,Seong CM,Chung WS,Huh JW

    更新日期:2009-06-01 00:00:00

  • Limitation of the activated partial thromboplastin time as a monitoring method of the direct thrombin inhibitor argatroban.

    abstract:BACKGROUND:Argatroban is licensed for patients with heparin-induced thrombocytopenia and monitoring is conventionally by activated partial thromboplastin time (APTT) ratio with a target of 1.5-3.0 and not exceeding 100 s. The APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Variabl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12414

    authors: Guy S,Kitchen S,Maclean R,Van Veen JJ

    更新日期:2015-12-01 00:00:00

  • Usefulness of automated fragmented red blood cell percentage in the diagnosis of paediatric haemolytic uraemic syndrome.

    abstract:INTRODUCTION:Presence of schistocytes in peripheral blood smear supporting haemolysis is important for diagnosis and decision-making in paediatric haemolytic uraemic syndrome (HUS). High observer dependency and requirement of expertise for peripheral smear evaluation propels us to think of other modalities to overcome ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13324

    authors: Govindarajan S,Bhatia P,Dawman L,Tiewsoh K

    更新日期:2021-02-01 00:00:00

  • Direct international normalized ratio determination using multicalibrators is more responsive than the conventional method for measuring prothrombin time.

    abstract::Direct international normalized ratio (INR) determination using certified INR plasmas was shown to improve precision and accuracy. We evaluated the utility of a multicalibrator in determining INR. INR values were measured in 493 blood samples from patients subjected to anticoagulation therapy (320) and control subject...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01195.x

    authors: Cha CH,Park CJ,Kim DH,Kim MJ,Cho YU,Jang S,Chi HS

    更新日期:2010-08-01 00:00:00

  • Establishment of reference interval for immature platelet fraction.

    abstract:INTRODUCTION:Immature platelet fraction (IPF) is a parameter for reticulated platelets. A high percentage IPF (%-IPF) is indicative of consumptive or recovering thrombocytopenic disorders in contrast to a low %-IPF seen in aplastic states. Absolute IPF (A-IPF) specifically reflects the number of immature platelets in c...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12049

    authors: Ko YJ,Kim H,Hur M,Choi SG,Moon HW,Yun YM,Hong SN

    更新日期:2013-10-01 00:00:00

  • Case report of HbC/beta(0)-thalassemia from India.

    abstract::This 22-year-old women presented to the ante-natal clinic of this hospital for prenatal screening for beta-thalassemia. Cation exchange high performance liquid chromatography (HPLC) using 'Beta Thalassemia Short Program' on Bio-Rad 'Variant' system revealed HbC value of 81.6%. The CBC showed microcytic hypochromic ane...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00850.x

    authors: Kumar S,Rana M,Handoo A,Saxena R,Verma IC,Bhargava M,Sood SK

    更新日期:2007-10-01 00:00:00

  • Use of a capillary specimen in the laboratory to verify a point-of-care international normalized ratio: Avoidance of a venipuncture in a pediatric setting.

    abstract:INTRODUCTION:Point-of-care (POC) international normalized ratio (INR) values above an institutional cutoff are confirmed in the laboratory using a gold standard venous specimen. This can be problematic in a pediatric setting. METHOD:In this study, 449 consecutive POC INR results were compared to an INR performed in th...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12920

    authors: Williams VK

    更新日期:2019-02-01 00:00:00

  • Detection of malignant cells in serous body fluids by counting high-fluorescent cells on the Sysmex XN-2000 hematology analyzer.

    abstract:INTRODUCTION:The body fluid mode of the Sysmex XN-2000 hematology analyzer differentiates cells into mononuclear and polymorphonuclear white blood cells (WBC) and high-fluorescent cells (HFC). The aim of this study was to evaluate the performance of the HFC count for detecting malignant cells in serous body fluids. ME...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12393

    authors: Labaere D,Boeckx N,Geerts I,Moens M,Van den Driessche M

    更新日期:2015-10-01 00:00:00

  • Clinical performance evaluation of the new hematology analyzer Mindray BC-6000.

    abstract:INTRODUCTION:With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. METHO...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13075

    authors: Shen Y,Cao J,Zhou Z,Wang Y,Shen Y,He J

    更新日期:2019-10-01 00:00:00

  • Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.

    abstract:INTRODUCTION:Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ijlh.13189

    authors: Sommer JM,Sadeghi-Khomami A,Barnowski C,Wikén M,Willemze AJ

    更新日期:2020-06-01 00:00:00

  • Diagnostic and prognostic utility of WBC counts and cell population data in patients with COVID-19.

    abstract:INTRODUCTION:Early diagnosis and identification of potential critical cases for timely treatment are crucial for COVID-19 patients. The aim of this study was to analyze the diagnostic and prognostic implications of WBC and cell population data (CPD) abnormalities related to COVID-19 at disease onset. METHODS:Baseline ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13395

    authors: Naoum FA,Ruiz ALZ,Martin FHO,Brito THG,Hassem V,Oliveira MGL

    更新日期:2020-11-15 00:00:00