Long-term structural changes and outcomes of implants in particulate cellular bone and marrow reconstructed jawbone.

Abstract:

BACKGROUND:Association between long-term structural changes of grafted bone and outcomes of the implants is not clear. PURPOSE:Morphometrical measurements and implant success were analyzed in subjects of particulate cellular bone and marrow (PCBM) reconstruction of the jawbone. MATERIALS AND METHODS:Subjects were 30 implants in 13 patients from a series of 24 PCBM reconstruction cases. The cortical bone thickness and cancellous computed tomography (CT) radiodensity values were retrospectively analyzed from the CT data of 27 subjects. The cumulative success rate of the implants in the PCBM reconstructed cases (pure graft) was compared with that of 127 implants of 56 native bone cases and 42 implants of 28 bone augmentation (partial graft) cases. RESULTS:In areas of PCBM reconstruction, cancellous CT radiodensity values were significantly high immediately after the surgery, and subsequently the values became stable. Cortical thickness was significantly increased, but did not reach that of native bone. Implant success rates were statistically not different (P = 0.783) between the native bone (91.3%), the partially grafted bone (95.2%), and the PCBM reconstructed bone (93.3%). CONCLUSION:Implants in pure grafted bone are mainly supported by cancellous bone, because cortical thickness remained thin for a long period of time.

authors

Matsuo A,Hamada H,Takahashi H,Chikazu D

doi

10.1111/cid.12723

subject

Has Abstract

pub_date

2019-04-01 00:00:00

pages

360-368

issue

2

eissn

1523-0899

issn

1708-8208

journal_volume

21

pub_type

杂志文章
  • Accuracy of two stereolithographic surgical templates: a retrospective study.

    abstract:BACKGROUND:The use of computer software and stereolithography for dental implant therapy has significantly increased during the last few years. The aim of this study was to evaluate and compare the mean accuracy and maximum deviations values of dental implant placement using two stereolithographic (SLA) guide systems. ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00369.x

    authors: Cassetta M,Giansanti M,Di Mambro A,Calasso S,Barbato E

    更新日期:2013-06-01 00:00:00

  • Single-tooth replacement in the anterior maxilla by means of immediate implantation and early loading: clinical and aesthetic results at 5 years.

    abstract:BACKGROUND:The hypothesis of the present study was that the early loading of single implants-supported restorations, replacing single extracting teeth in the anterior region of the maxilla in case of fresh extraction sockets with residual hard and soft tissue preservation, could be a successful procedure. METHODS:Twen...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12111

    authors: Guarnieri R,Ceccherini A,Grande M

    更新日期:2015-04-01 00:00:00

  • A long-term prospective cohort study on immediately restored single tooth implants inserted in extraction sockets and healed ridges: CBCT analyses, soft tissue alterations, aesthetic ratings, and patient-reported outcomes.

    abstract:BACKGROUND:Although many studies have been published on single implants, long-term data remain scarce. PURPOSE:To evaluate immediately restored single implants after at least 8 years of follow-up in terms of buccal bone, soft tissue alterations, aesthetic ratings, and patient-reported outcomes. MATERIALS AND METHODS:...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12613

    authors: Raes S,Eghbali A,Chappuis V,Raes F,De Bruyn H,Cosyn J

    更新日期:2018-08-01 00:00:00

  • Immediate fixed rehabilitation of the edentulous maxilla: a prospective clinical and radiological study after 3 years of loading.

    abstract:PURPOSE:The aim of this study was to prospectively evaluate the clinical and radiographic outcomes of immediate full-arch fixed maxillary prosthesis supported by two axial and four tilted implants after 3 years of loading. MATERIALS AND METHODS:Thirty-two patients with atrophic maxilla were consecutively enrolled and ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2012.00482.x

    authors: Agliardi EL,Pozzi A,Stappert CF,Benzi R,Romeo D,Gherlone E

    更新日期:2014-04-01 00:00:00

  • Overdentures in the edentulous mandible supported by implants and retained by a Dolder bar: a 5-year prospective study.

    abstract:PURPOSE:This prospective study was performed to evaluate the outcomes of XiVE® S plus implants (Dentsply Friadent, Mannheim, Germany) following conventional restoration with bar structures and overdentures in the edentulous mandible. MATERIALS AND METHODS:A total of 39 patients were treated with four interforaminal im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2011.00380.x

    authors: Heschl A,Payer M,Clar V,Stopper M,Wegscheider W,Lorenzoni M

    更新日期:2013-08-01 00:00:00

  • Remodeling of calvarial graft in increased atrophic maxillary thickness. A prospective clinical study.

    abstract:PURPOSE:This study evaluated the autogenous graft resorption rate in a calvarial block graft in the anterior region of an atrophic maxilla and compared it with the thickness of the remaining ridge. MATERIALS AND METHODS:Twelve patients were included in the study. They were submitted to cranial calotte graft surgery, a...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12869

    authors: de Carvalho FA,Ponzoni D,Vedovatto E,de Carvalho PSP

    更新日期:2020-02-01 00:00:00

  • Abutment screw loosening and bending resistance of external hexagon implant system after lateral cyclic loading.

    abstract:BACKGROUND:Rigorous efforts to reduce the recurrence of abutment screw loosening in single-tooth implant restorations have recently been made. However, the behavior of the implant/abutment joint components with respect to critical bending force is still unclear. PURPOSE:This study investigated the effect of different ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2004.tb00216.x

    authors: Khraisat A,Abu-Hammad O,Dar-Odeh N,Al-Kayed AM

    更新日期:2004-01-01 00:00:00

  • A restoratively driven ridge categorization, as determined by incorporating ideal restorative positions on radiographic templates utilizing computed tomography scan analysis.

    abstract:BACKGROUND:The introduction of implants into the field of dentistry has revolutionized the way we evaluate edentulous ridges. In an attempt to evaluate the deficient edentulous ridge, numerous classification systems have been proposed. Each of these classification systems implements a different approach for evaluating ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00125.x

    authors: Elian N,Ehrlich B,Jalbout Z,Cho SC,Froum S,Tarnow D

    更新日期:2009-12-01 00:00:00

  • Deproteinized Bovine Bone Mineral or Autologous Bone at Dehiscence Type Defects at Implants Installed Immediately into Extraction Sockets: An Experimental Study in Dogs.

    abstract:PURPOSE:The aim of this study was to evaluate bone regeneration at surgically created dehiscence buccal defects at implants placed immediately into extraction sockets (IPIES) of small dimensions filled with autogenous bone or deproteinized bovine bone mineral (DBBM) associated with a collagen membrane. MATERIALS AND M...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12328

    authors: Pereira FP,De Santis E,Hochuli-Vieira E,de Souza Faco EF,Pantani F,Salata LA,Botticelli D

    更新日期:2016-06-01 00:00:00

  • Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque.

    abstract:BACKGROUND:Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. PURPOSE:The purpose of the present in vitro study was to evaluate the mechanical behavior of geometric changes in the apex region of dental implants. METHODS:Thirty-five cylindrical de...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12574

    authors: Sciasci P,Casalle N,Vaz LG

    更新日期:2018-06-01 00:00:00

  • Healing of extraction sockets filled with BoneCeramic® prior to implant placement: preliminary histological findings.

    abstract:BACKGROUND:Various grafting materials have been designed to minimize edentulous ridge volume loss following tooth extraction by encouraging new bone formation in healing sockets. BoneCeramic® is a composite of hydroxyapatite and bèta-tricalcium phosphate with pores of 100-500 microns. PURPOSES:The aim of this study wa...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00184.x

    authors: De Coster P,Browaeys H,De Bruyn H

    更新日期:2011-03-01 00:00:00

  • A 3-year retrospective study of Cresco frameworks: preload and complications.

    abstract:PURPOSE:The aim of this retrospective clinical study was to evaluate the clinical outcome of fixed implant-supported complete prostheses on Astra or Brånemark implants when using either conventional cast frameworks or frameworks produced according to the Cresco Ti Precision method (Cresco Ti Systems Sàrl., Lausanne, Sw...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00064.x

    authors: Hjalmarsson L,Smedberg JI

    更新日期:2005-01-01 00:00:00

  • Clinical and radiographic peri-implant outcomes of short dental implants placed in posterior jaws of patients with treated generalized aggressive periodontitis: A 3-year follow-up study.

    abstract:BACKGROUND:Studies assessing clinical and radiographic peri-implant parameters around short dental implants (SDIs) in treated generalized aggressive periodontitis (GAgP) patients are scant. OBJECTIVES:This 3-year follow-up study aimed to compare the clinical peri-implant and radiographic bone status around SDIs placed...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12761

    authors: Akram Z,Vohra F,Sheikh SA,Albaijan R,Bukhari IA,Hussain M

    更新日期:2019-08-01 00:00:00

  • Topography, microhardness, and precision of fit on ready-made zirconia abutment before/after sintering process.

    abstract:BACKGROUND:Sintering porcelain on a ceramic abutment may change the microstructure and result in aging processes that influence the mechanical properties, internal strain, and the three-dimensional form of the abutment, thus causing a possible misfit between the abutment and the fixture. PURPOSE:The aim was to investi...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1708-8208.2007.00044.x

    authors: Kanno T,Milleding P,Wennerberg A

    更新日期:2007-09-01 00:00:00

  • Immediate loading of two implants with a mandibular implant-retained overdenture: a new treatment protocol.

    abstract:PURPOSE:The aim of this study was to present the clinical outcomes of the immediate loading of two bar-splinted implants retaining a mandibular overdenture. MATERIALS AND METHODS:In a clinical trial, 124 edentulous patients were treated according to a new treatment concept, which involves the immediate loading of two ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2009.00210.x

    authors: Stoker GT,Wismeijer D

    更新日期:2011-12-01 00:00:00

  • One-year results of a prospective multicenter study on Brånemark System implants with a TiUnite surface.

    abstract:BACKGROUND:A moderately rough surface implant (TiUnite, Nobel Biocare AB, Göteborg, Sweden) was introduced in 2000. Laboratory studies and some clinical studies have demonstrated excellent bone response in the early healing phase. PURPOSE:The aim of this prospective multicenter study was to follow a large number of co...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/j.1708-8208.2005.tb00077.x

    authors: Friberg B,Dahlin C,Widmark G,Ostman PO,Billström C

    更新日期:2005-01-01 00:00:00

  • Microstructure of titanium-cement-lithium disilicate interface in CAD-CAM dental implant crowns: a three-dimensional profilometric analysis.

    abstract:BACKGROUND:Peri-implantitis is an infection of the implant surface caused by adhesion of bacteria that generate bone resorption and sometimes even consequent implant loss. Both screw-retained and cemented fixed implants are affected. PURPOSE:The purpose of this study is to investigate the morphological defects at the ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12133

    authors: Cresti S,Itri A,Rebaudi A,Diaspro A,Salerno M

    更新日期:2015-01-01 00:00:00

  • Comparison of immediate-load mini dental implants and conventional-size dental implants to retain mandibular Kennedy class I removable partial dentures: A randomized clinical trial.

    abstract:BACKGROUND:Complications of distal extension mandibular removable partial dentures are: loss of retention, irritation, and so forth. Dental implants have been used to support distal extension removable partial dentures. However, many patients have limited bone support in which to place conventional-size dental implants...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12646

    authors: Threeburuth W,Aunmeungtong W,Khongkhunthian P

    更新日期:2018-10-01 00:00:00

  • Time-dependent changes in fresh-frozen bone block grafts: tomographic, histologic, and histomorphometric findings.

    abstract:BACKGROUND:Bone allografts have shown satisfactory clinical results in alveolar ridge reconstructions. However, the process of incorporation and the resorption rates of these grafts are not yet fully understood. PURPOSE:The aim of this study was to use computed tomography (CT), histology, and histomorphometry to asses...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12108

    authors: Deluiz D,Oliveira LS,Pires FR,Tinoco EM

    更新日期:2015-04-01 00:00:00

  • Monolithic implant-supported lithium disilicate (LS2) crowns in a complete digital workflow: A prospective clinical trial with a 2-year follow-up.

    abstract:BACKGROUND:The technical development of digital processing allows the production of anatomically full-contoured implant-supported restorations. PURPOSE:The aim of this prospective clinical trial was to analyze the treatment concept of monolithic lithium disilicate (LS2) single-unit restorations in a complete digital w...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/cid.12472

    authors: Joda T,Ferrari M,Brägger U

    更新日期:2017-06-01 00:00:00

  • Terminal Posterior Tilted Implants Planned as a Sinus Graft Alternative for Fixed Full-Arch Implant-Supported Maxillary Restoration: A Case Series with 10- to 19-Year Results on 44 Consecutive Patients Presenting for Routine Maintenance.

    abstract:PURPOSE:Posterior maxillary tilted implants are gaining prevalence as an alternative to sinus grafts supporting fixed maxillary restorations. This paper reports long-term results after loading using this technique. MATERIALS AND METHODS:Consecutive patients presenting for either routine hygiene maintenance or unplanne...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12433

    authors: Fortin Y,Sullivan RM

    更新日期:2017-02-01 00:00:00

  • The effect of a 2-mm inter-implant distance on esthetic outcomes in immediately non-occlusally loaded platform shifted implants in healed ridges: 12-month results of a randomized clinical trial.

    abstract:BACKGROUND:Three millimeter is considered as the minimum distance to obtain soft and bone tissue stability in case of adjacent implants. The possibility to preserve peri-implant bone level using a platform switching connection has questioned this concept. PURPOSE:The study evaluates soft tissue maintenance and margina...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12926

    authors: Rivara F,Macaluso GM,Toffoli A,Calciolari E,Goldoni M,Lumetti S

    更新日期:2020-08-01 00:00:00

  • Scientific Interests of 21st Century Clinical Oral Implant Research: Topical Trend Analysis.

    abstract:BACKGROUND:Discrimination between ongoing and solved research questions may help to distinguish established dogmas from evidence-based implant dentistry. PURPOSE:The purpose of this study was to investigate topics of interest in the field of oral implant science and evolving thematic trends in clinical studies during ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,评审

    doi:10.1111/cid.12371

    authors: Pommer B,Valkova V,Ubaidha Maheen C,Fürhauser L,Rausch-Fan X,Seeman R

    更新日期:2016-08-01 00:00:00

  • Longitudinal analysis on the effect of insertion torque on delayed single implants: A 3-year randomized clinical study.

    abstract:BACKGROUND:Implant stability is commonly related to insertion torque. Recently, it has been suggested that higher insertion torque may lead to greater bone resorption. PURPOSE:The aim of the present randomized clinical study was to evaluate the role of different insertion torque values in terms of implant success, mar...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12586

    authors: Marconcini S,Giammarinaro E,Toti P,Alfonsi F,Covani U,Barone A

    更新日期:2018-06-01 00:00:00

  • Effects of air abrasive decontamination on titanium surfaces: A systematic review of in vitro studies.

    abstract:BACKGROUND:Air abrasion (AA) is one of the decontamination methods that have demonstrated promising results in treating peri-implant diseases. PURPOSE:This systematic review aimed at evaluating the in vitro effect of AA on surface change, cleaning efficacy, and biocompatibility of titanium surfaces and at comparing it...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12747

    authors: Moharrami M,Perrotti V,Iaculli F,Love RM,Quaranta A

    更新日期:2019-04-01 00:00:00

  • A Human Clinical, Histological, Histomorphometrical, and Radiographical Study on Biphasic HA-Beta-TCP 30/70 in Maxillary Sinus Augmentation.

    abstract:BACKGROUND:By mixing hydroxyapatite (HA) and tricalcium phosphate (TCP), biphasic calcium phosphate ceramics can be obtained, and by varying their ratio it is possible to tailor the characteristics of the biomaterial. PURPOSE:The aim of the present human study was to evaluate the histological and radiographical aspect...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12145

    authors: Mangano C,Sinjari B,Shibli JA,Mangano F,Hamisch S,Piattelli A,Perrotti V,Iezzi G

    更新日期:2015-06-01 00:00:00

  • Location of implant-retained fixed dentures affects oral health-related quality of life.

    abstract:BACKGROUND:The effects of the locations of dental implants on treatment outcomes, as evaluated by oral health-related quality of life (OHRQoL) assessment, remain controversial. PURPOSE:To investigate the association between the locations of dental implants and changes in OHRQoL. MATERIALS AND METHODS:Sixty-eight subj...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12497

    authors: Hara M,Matsumoto T,Yokoyama S,Higuchi D,Baba K

    更新日期:2017-08-01 00:00:00

  • Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: an in vivo study.

    abstract:BACKGROUND:Implant surface topography influences the bone response after implantation. However, the importance of surface orientation is not known. PURPOSE:The aim of this study was to investigate the bone tissue response and the stability of titanium implants prepared with isotropic and anisotropic surfaces of simila...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00042.x

    authors: Göransson A,Wennerberg A

    更新日期:2005-01-01 00:00:00

  • Clinical experience of CNC-milled titanium frameworks supported by implants in the edentulous jaw: a 3-year interim report.

    abstract:BACKGROUND:The use of computer numeric controlled (CNC)-milled titanium frameworks is a new technique for framework fabrication, and few clinical reports have been made on this treatment modality. PURPOSE:The goal of this study was to report the clinical performance of implant-supported prostheses with CNC-milled tita...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2002.tb00159.x

    authors: Ortorp A,Jemt T

    更新日期:2002-01-01 00:00:00

  • CAD/CAM implant crowns in a digital workflow: Five-year follow-up of a prospective clinical trial.

    abstract:BACKGROUND:Implant restorations became the first choice for single-tooth replacement today. PURPOSE:The prospective clinical trial aims to investigate computer-aided-design (CAD)/computer-aided-manufacturing (CAM)-processed implant crowns after 5 years of loading. MATERIALS AND METHODS:Twenty patients were included f...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12681

    authors: Joda T,Bragger U,Zitzmann NU

    更新日期:2019-02-01 00:00:00