The clinical utility of new reticulocyte and erythrocyte parameters on the Sysmex XN 9000 for iron deficiency in pregnant patients.

Abstract:

INTRODUCTION:Iron deficiency (ID) is a major cause of morbidity in pregnancy. Antenatal clinics use a hemoglobin to screen for ID, which delays the diagnosis of subclinical ID. The aim of this study was to investigate the clinical utility of the percentage of microcytic red cells (%Micro-R), percentage of hypochromic red cells (%Hypo-He), and reticulocyte hemoglobin content (Ret-He) on the Sysmex hematology analyzer in pregnant patients. METHODS:For this study, 102 nonanemic patients in the first trimester of pregnancy presenting for the first time to antenatal clinic were screened for ID. There were 50 (49.02%) patients with ID as defined according to iron studies. The independent t test and receiver operating characteristic (ROC) analysis were applied. RESULTS:There was a significant difference in the Ret-He, %Micro-R, and %Hypo-He between the ID and non-ID groups (P < 0.001). The area under curve (AUC) for the Ret-He (0.81, 95% CI 0.71-0.88) indicates that the Ret-He at a cutoff <31.2 pg is the best discriminator of ID (P < 0.0001). The AUC of %Hypo-He (0.78, 95% CI 0.69-0.86) was not superior to the mean cell hemoglobin (0.78, 95% CI 0.69-0.86). The %Micro-R (0.79, 95% CI 0.70-0.87) showed improved diagnostic accuracy compared to mean cell volume (0.75, 95% CI 0.65-0.83). CONCLUSION:The new reticulocyte and erythrocyte parameters are reliable tests for the diagnosis of subclinical ID in pregnant patients. Further studies, however, are required to confirm the diagnostic utility of the erythrocyte parameters in pregnant patients. These tests will benefit the management of pregnant patients attending antenatal clinic.

journal_name

Int J Lab Hematol

authors

Levy S,Schapkaitz E

doi

10.1111/ijlh.12904

subject

Has Abstract

pub_date

2018-12-01 00:00:00

pages

683-690

issue

6

eissn

1751-5521

issn

1751-553X

journal_volume

40

pub_type

临床试验,杂志文章
  • Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.

    abstract:INTRODUCTION:Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ijlh.13189

    authors: Sommer JM,Sadeghi-Khomami A,Barnowski C,Wikén M,Willemze AJ

    更新日期:2020-06-01 00:00:00

  • Case report of HbC/beta(0)-thalassemia from India.

    abstract::This 22-year-old women presented to the ante-natal clinic of this hospital for prenatal screening for beta-thalassemia. Cation exchange high performance liquid chromatography (HPLC) using 'Beta Thalassemia Short Program' on Bio-Rad 'Variant' system revealed HbC value of 81.6%. The CBC showed microcytic hypochromic ane...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00850.x

    authors: Kumar S,Rana M,Handoo A,Saxena R,Verma IC,Bhargava M,Sood SK

    更新日期:2007-10-01 00:00:00

  • Direct international normalized ratio determination using multicalibrators is more responsive than the conventional method for measuring prothrombin time.

    abstract::Direct international normalized ratio (INR) determination using certified INR plasmas was shown to improve precision and accuracy. We evaluated the utility of a multicalibrator in determining INR. INR values were measured in 493 blood samples from patients subjected to anticoagulation therapy (320) and control subject...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01195.x

    authors: Cha CH,Park CJ,Kim DH,Kim MJ,Cho YU,Jang S,Chi HS

    更新日期:2010-08-01 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • Sickle cell-haemoglobin E (HbSE) compound heterozygosity: a clinical and haematological study.

    abstract::The paucity of clinical reports in the world literature suggests that, as a disease entity, haemoglobin SE compound heterozygosity is of negligible importance. In view of the significant community prevalence of this haemoglobinopathy in the Sultanate of Oman where it is the second most prevalent sickling disorder, a h...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1365-2257.2006.00886.x

    authors: Knox-Macaulay HH,Ahmed MM,Gravell D,Al-Kindi S,Ganesh A

    更新日期:2007-08-01 00:00:00

  • How I investigate Eosinophilia.

    abstract::Eosinophilia is typically secondary, that is, reactive, in nature and is associated with a wide variety of neoplastic and non-neoplastic disorders. Clonal eosinophilia is also seen in a wide variety of hematopoietic neoplasms, and sub-classification can be diagnostically challenging. A proper evaluation of persistent ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12955

    authors: Larsen RL,Savage NM

    更新日期:2019-04-01 00:00:00

  • Comparison of five point-of-care D-dimer assays with the standard laboratory method.

    abstract:INTRODUCTION:D-dimer (DD) assays are effective for the exclusion of deep-vein thrombosis (DVT), but point-of-care (POC) DD assays have not been fully evaluated. METHODS:We have compared five POC DD assays (Pathfast, Cardiac, Vidas, Stratus and NycoCard) with our routine DD method (Tinaquant), testing 60 samples from p...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01421.x

    authors: Antovic JP,Höög Hammarström K,Forslund G,Eintrei J,Sten-Linder M

    更新日期:2012-10-01 00:00:00

  • Proteasome inhibitor bortezomib overcomes P-gp-mediated multidrug resistance in resistant leukemic cell lines.

    abstract:INTRODUCTION:To study the effect of bortezomib alone or in combination with daunorubicin (DNR) on an mdr1 single-factor drug-resistant leukemia cell line K562/MDR1, a multifactor-resistant cell line K562/A02, a drug-sensitive cell line K562, and primary cells from acute myeloid leukemia patients. METHODS:The cell line...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01384.x

    authors: Zheng B,Zhou R,Gong Y,Yang X,Shan Q

    更新日期:2012-06-01 00:00:00

  • The evaluation of the relevance of thrombin generation and procoagulant activity in thrombotic risk assessment in BCR-ABL-negative myeloproliferative neoplasm patients.

    abstract:INTRODUCTION:It has been recently suggested that microparticles (MP) play a role in the pathogenesis of thrombotic complications. This study aimed to assess the contribution of procoagulant activity expressed by circulating MP in thrombotic events in MPN patients. METHODS:Seventy-four MPN patients were enrolled in a t...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12676

    authors: Baccouche H,Ben Jemaa M,Chakroun A,Chadi S,Mahjoub S,Sfar I,Gorgi Y,Ben Romdhane N

    更新日期:2017-10-01 00:00:00

  • 2016 WHO Classification update-What's new in lymphoid neoplasms.

    abstract::In the 8 years since the publication of the 4th edition of the WHO Classification of Hematopoietic and Lymphoid Tumours in 2008, there has been rapid accumulation of knowledge in the molecular genetics, biology, clinical behavior of many hematologic malignancies. Concepts and models have advanced to the point at which...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12650

    authors: Hsi ED

    更新日期:2017-05-01 00:00:00

  • Performance evaluation of a new Stago® automated haemostasis analyser: The STA R Max® 2.

    abstract:INTRODUCTION:The STA R Max® 2 is a new coagulation analyser developed by Diagnostica Stago, able to perform clotting, chromogenic and immuno-turbidimetric tests. A pre-analytical module build into the cap-piercing needle performs the sample integrity verification (sample tube filling and measurement of haemolysis, icte...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13100

    authors: Cupaiolo R,Govaerts D,Blauwaert M,Cauchie P

    更新日期:2019-12-01 00:00:00

  • Assessing maternal clotting function with novel global coagulation assays: A prospective pilot study.

    abstract:INTRODUCTION:Women are at higher risk of venous thromboembolism (VTE) during pregnancy and the puerperium. Global coagulation assays (GCAs), including thromboelastography (TEG), thrombin generation using the calibrated automated thrombogram (CAT) and fibrin generation using the overall haemostatic potential assay (OHP)...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13389

    authors: O'Keefe D,Lim HY,Tham J,Ho P,Hui L

    更新日期:2020-11-10 00:00:00

  • Accuracy of serum transferrin receptor levels in the diagnosis of iron deficiency among hospital patients in a population with a high prevalence of thalassaemia trait.

    abstract::The diagnosis of iron deficiency in hospital patients can be difficult in the presence of inflammation. A raised serum transferrin receptor (sTfR) level is useful as a marker of iron deficiency as it is unaffected by inflammation. However, diseases that cause an increase in erythropoietic activity can also result in a...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00982.x

    authors: Ong KH,Tan HL,Tam LP,Hawkins RC,Kuperan P

    更新日期:2008-12-01 00:00:00

  • Abnormal scattergrams and cell population data generated by fully automated hematological analyzers: New tools for screening malaria infection?

    abstract:INTRODUCTION:Malaria is a life-threatening infectious disease, which has been for long confined to specific endemic areas. Nevertheless, the recent increase in immigration flows from endemic regions and imported cases has reemphasized many diagnostic challenges in Western countries, thus paving the way to introduce rap...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12790

    authors: Buoro S,Manenti B,Seghezzi M,Moioli V,Bagorria M,Callegaro A,Ottomano C,Lippi G

    更新日期:2018-06-01 00:00:00

  • Usefulness of thyrogastric immune features as predictors of pernicious anaemia that lacks intrinsic factor antibody.

    abstract:INTRODUCTION:The study aims to evaluate the diagnostic utility of thyrogastric immune features in the identification of intrinsic factor antibody negative (IFA -ve) pernicious anaemia (PA) patients. METHODS:Clinico-pathological features of 'intrinsic factor antibody positive (IFA +ve) PA' and 'IFA -ve presumed PA' Chi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01295.x

    authors: Chan J,Chan HY

    更新日期:2011-08-01 00:00:00

  • The automation of routine light transmission platelet aggregation.

    abstract:INTRODUCTION:The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS:We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12161

    authors: Lawrie AS,Kobayashi K,Lane PJ,Mackie IJ,Machin SJ

    更新日期:2014-08-01 00:00:00

  • CD34, RAB20, PU.1 and GFI1 mRNA expression in myelodysplastic syndrome.

    abstract::Myelodysplastic syndrome (MDS) with hypocellular bone marrow (BM) is often difficult to distinguish from aplastic anemia (AA). Furthermore, the diagnosis of MDS with low blast counts and normal karyotype may be problematic. These issues highlight the need for a reliable marker for the diagnosis of MDS. This study was ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01056.x

    authors: Huh HJ,Chae SL,Lee M,Hong KS,Mun YC,Seong CM,Chung WS,Huh JW

    更新日期:2009-06-01 00:00:00

  • An investigation of the protective effect of alpha+-thalassaemia against severe Plasmodium falciparum amongst children in Kumasi, Ghana.

    abstract:INTRODUCTION:Several factors influence the severity of Plasmodium falciparum; here, we investigate the impact of alpha+-thalassaemia genotype on P. falciparum parasitemia and prevalence of severe anaemia amongst microcytic children from Kumasi, Ghana. METHODS:Seven hundred and thirty-two children (≤10 years) with P. f...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12122

    authors: Opoku-Okrah C,Gordge M,Kweku Nakua E,Abgenyega T,Parry M,Robertson C,Smith CL

    更新日期:2014-02-01 00:00:00

  • Evaluation of the CellaVision DM automated microscope in pediatrics.

    abstract::The DM is an automated microscope, which performs WBC differential counts and monitors red cell morphology. The user either validates the cell recognition if the DM has correctly identified the WBCs or reclassifies the WBCs in the good category in case of a DM mis-assignment. Morphological anomalies of leukocytes, red...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01219.x

    authors: Billard M,Lainey E,Armoogum P,Alberti C,Fenneteau O,Da Costa L

    更新日期:2010-10-01 00:00:00

  • The applicability of multiparameter flow cytometry for the detection of minimal residual disease using different-from-normal panels to predict relapse in patients with acute myeloid leukemia after allogeneic transplantation.

    abstract:BACKGROUND:The MRD status detected using multiparameter flow cytometry (MFC) before allogeneic hematopoietic stem cell transplantation (allo-HSCT) has crucial prognostic value for patients with acute myeloid leukemia (AML) in morphologic complete remission (CR). We designed a novel panel of antibodies to identify aberr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13070

    authors: Wang Z,Guo M,Zhang Y,Xu S,Cheng H,Wu J,Zhang W,Hu X,Yang J,Wang J,Tang G

    更新日期:2019-10-01 00:00:00

  • Expression of CD4 is correlated with an unfavorable prognosis in wild-type NPM1, FLT3-ITD-negative cytogenetically normal adult acute myeloid leukemia.

    abstract:INTRODUCTION:In the cytogenetically normal population of AML (CN-AML), FLT3-ITD-positive and wild-type NPM1 is correlated with a worse outcome, and FLT3-ITD-negative with NPM1-mut is correlated with a better outcome. This leaves a large subpopulation of CN-AML patients without NPM1 or FLT3-ITD mutations with heterogene...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12649

    authors: Guo RJ,Atenafu EG,Schimmer AD,Minden MD,Chang H

    更新日期:2017-08-01 00:00:00

  • Evaluation of amotosalem treated platelets over 7 days of storage with an automated cytometry assay panel.

    abstract:INTRODUCTION:Pathogen Inactivation allows to overcome microbial contamination and growth related to storage of platelets concentrates (PC) at room temperature. The aim of our study was to evaluate the platelet storage lesion extending the storage period of pathogen inactivated platelet concentrates over 7 days using an...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12102

    authors: Diquattro M,De Francisci G,Bonaccorso R,Tagliavia AM,Marcatti M,Palma B,Agliastro R

    更新日期:2013-12-01 00:00:00

  • Expression analysis of BECN1 in acute myeloid leukemia: association with distinct cytogenetic and molecular abnormalities.

    abstract:INTRODUCTION:In acute myeloid leukemia (AML), it has been shown that AML-derived cells often remain sensitive to autophagy-inducing stimuli, leading to the idea that harnessing the autophagy can be pertinent to AML cytotoxic therapy. Despite this promising notion, to date, there is no comprehensive study addressing aut...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12454

    authors: Zare-Abdollahi D,Safari S,Movafagh A,Ghadiani M,Tabarraee M,Riazi-Isfahani S,Gorji S,Keyvan L,Gachkar L

    更新日期:2016-04-01 00:00:00

  • The HemoScreen hematology point-of-care device is suitable for rapid evaluation of acute leukemia patients.

    abstract:BACKGROUND:Hematological patients, receiving intensive chemotherapy (predominantly acute leukemia patients), have repeated postchemotherapy periods with severe bone marrow suppression. As a result, these patients require regular monitoring of the complete blood counts (CBC) for optimal patient care. To reduce the strai...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13330

    authors: Kristian Kur D,Thøgersen D,Kjeldsen L,Friis-Hansen L

    更新日期:2021-02-01 00:00:00

  • Morphologic and cytogenetic variables affect the flow cytometric recovery of plasma cell myeloma cells in bone marrow aspirates.

    abstract:INTRODUCTION:It is widely recognized that plasma cells (PCs) are under-represented in flow cytometry (FC) studies, but the causes of this phenomenon are poorly understood. We sought to study potential variables that affect PC recovery by flow cytometry (FC) in the analysis of plasma cell myeloma (PCM). METHODS:We retr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12411

    authors: Cogbill CH,Spears MD,Vantuinen P,Harrington AM,Olteanu H,Kroft SH

    更新日期:2015-12-01 00:00:00

  • Upregulation of long noncoding RNA Lnc-IRF2-3 and Lnc-ZNF667-AS1 is associated with poor survival in B-chronic lymphocytic leukemia.

    abstract:BACKGROUND:Lnc-IRF2-3 and Lnc-ZNF667-AS1 were recently studied as a positive biomarker for many tumor cells. However, experimental studies found that they are associated with worse outcomes in B-CLL. METHODS:A prospective case study was conducted on 135 B-CLL patients that were compared to thirty healthy controls. The...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13167

    authors: El-Khazragy N,Esmaiel MA,Mohamed MM,Hassan NS

    更新日期:2020-06-01 00:00:00

  • Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

    abstract:INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12486

    authors: Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

    更新日期:2016-06-01 00:00:00

  • Establishment of reference intervals for complete blood count parameters in venous blood for children in the Xiamen area, China.

    abstract:OBJECTIVES:To observe changes in the complete blood count (CBC) venous blood parameters of healthy children and establish appropriate reference intervals (RIs). METHODS:Overall, 4066 healthy children were selected and divided into four groups: infants, toddlers, preschool-age children and school-age children. Venous b...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13095

    authors: Li J,Zhang H,Huang X,Zhang J,Wu X

    更新日期:2019-10-01 00:00:00

  • Different kinetic patterns of BCR-ABL transcript levels in imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response.

    abstract::Bone marrow BCR-ABL transcript levels were monitored serially by real-time quantitative PCR in 46 imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response (CCyR) for a median of 42 months (range: 9-53). Of 41 patients in continuous CCyR, 32 and nine could achieve a >/=3-log (MMo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00962.x

    authors: Qin YZ,Liu YR,Zhu HH,Li JL,Ruan GR,Zhang Y,Jiang Q,Jiang H,Li LD,Chang Y,Huang XJ,Chen SS

    更新日期:2008-08-01 00:00:00

  • Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers.

    abstract::Modern photo-optical coagulometers collect optical data in the form of reaction curves and offer a possibility to determine clotting times at different points of clot formation by using different evaluation modes. The objectives of this study were to determine the possible impact of an evaluation mode on activated par...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01111.x

    authors: Milos M,Herak DC,Zadro R

    更新日期:2010-02-01 00:00:00