Central echogenic areas in thyroid nodules: Diagnostic performance in prediction of papillary cancer.

Abstract:

PURPOSE:To determine the diagnostic performance of the "central echogenic area" sonographic finding in differentiating papillary carcinomas from benign nodules and to how this finding may be used to improve fine needle aspiration(FNA) technique/utilization. MATERIALS AND METHODS:We retrospectively analyzed ultrasound guided FNAs of thyroid nodules between 1 and 3 cm for central echogenic areas. 92 patients (evenly distributed benign vs papillary carcinoma) were evaluated by a blinded reader for areas of non-shadowing homogenously echogenic centers within the nodules and correlated with FNA proven pathologic diagnosis. A selection of nodules with the central echogenic area finding were selected for further slide review to establish a pathologic basis for the finding. RESULTS:Diagnostic performance of the "central echogenic area" feature in papillary thyroid cancers was 52.2% sensitive and 91.3% specific for papillary thyroid carcinoma with a PPV of 85.7% and NPV of 65.6%. There was a significant correlation with a p < 0.01 between the central echogenic area finding and papillary carcinoma. On pathologic slide review, nodules with central echogenic areas consistently demonstrated a central scar with conglomerate fibrosis and very few viable cells. CONCLUSION:Despite its relatively low sensitivity, the central echogenic area finding is highly specific for papillary carcinoma of the thyroid and can be a useful sonographic finding in decisions regarding FNA. Additionally, due to the paucity of cells and high density of conglomerate fibrosis, central echogenic areas should be avoided during FNA to decrease the chance of an inadequate sample collection.

journal_name

Eur J Radiol

authors

Siebert SM,Jeffrey RB,Gomez AJ,Kamaya A

doi

10.1016/j.ejrad.2018.01.029

subject

Has Abstract

pub_date

2018-04-01 00:00:00

pages

45-49

eissn

0720-048X

issn

1872-7727

pii

S0720-048X(18)30037-8

journal_volume

101

pub_type

杂志文章
  • Effect of digital edge-enhancement on the visibility of normal parenchymal lung markings.

    abstract::Digital 'conventional-like' (C-L) and edge-enhanced (E-E) posteroanterior chest roentgenograms of 42 healthy individuals were ranked twice (interval of at least 5 days) in the order of increasing lung parenchymal markings (a total of four rankings). This was done by three radiologists, two residents, one medical stude...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(94)90275-5

    authors: Vehmas T,Korhola O,Pölönen P,Knuutila T,Kivisaari A,Holmberg J,Bondestam S,Tikkanen H

    更新日期:1994-05-01 00:00:00

  • Artificial intelligence assistance improves reporting efficiency of thoracic aortic aneurysm CT follow-up.

    abstract:OBJECTIVE:Follow-up of aortic aneurysms by computed tomography (CT) is crucial to balance the risks of treatment and rupture. Artificial intelligence (AI)-assisted radiology reporting promises time savings and reduced inter-reader variabilities. METHODS:The influence of AI assistance on the efficiency and accuracy of ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109424

    authors: Rueckel J,Reidler P,Fink N,Sperl J,Geyer T,Fabritius MP,Ricke J,Ingrisch M,Sabel BO

    更新日期:2021-01-01 00:00:00

  • Analysis of left atrial appendix by dual-source CT coronary angiography: morphologic classification and imaging by volume rendered CT images.

    abstract:AIM:We investigated the evaluability of left atrial appendix by dual source coronary CT angiography and analyzed morphologic features. MATERIALS AND METHODS:We included 106 consecutive patients who underwent coronary CT angiography for various indications. Technical parameters were slice thickness 0.6 mm, reconstructi...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.11.008

    authors: Erol B,Karcaaltincaba M,Aytemir K,Cay N,Hazirolan T,Akata D

    更新日期:2011-12-01 00:00:00

  • Diagnostic performance of fractional flow reserve derived from coronary CT angiography for detection of lesion-specific ischemia: A multi-center study and meta-analysis.

    abstract:PURPOSE:To evaluate the diagnostic performance of coronary computed tomography angiography derived fractional flow reserve (CT-FFR) with invasive fractional flow reserve (FFR) in patients with coronary artery disease" before "with invasive fractional flow reserve serving as the reference standard. MATERIALS AND METHOD...

    journal_title:European journal of radiology

    pub_type: 杂志文章,meta分析,多中心研究

    doi:10.1016/j.ejrad.2019.04.011

    authors: Tang CX,Wang YN,Zhou F,Schoepf UJ,Assen MV,Stroud RE,Li JH,Zhang XL,Lu MJ,Zhou CS,Zhang DM,Yi Y,Yan J,Lu GM,Xu L,Zhang LJ

    更新日期:2019-07-01 00:00:00

  • Portosystemic pressure reduction achieved with TIPPS and impact of portosystemic collaterals for the prediction of the portosystemic-pressure gradient in cirrhotic patients.

    abstract:PURPOSE:The portosystemic pressure gradient is an important factor defining prognosis in hepatic disease. However, noninvasive prediction of the gradient and the possible reduction by establishment of a TIPSS is challenging. A cohort of patients receiving TIPSS was evaluated with regard to imaging features of collatera...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2013.08.017

    authors: Grözinger G,Wiesinger B,Schmehl J,Kramer U,Mehra T,Grosse U,König C

    更新日期:2013-12-01 00:00:00

  • Textural differences between renal cell carcinoma subtypes: Machine learning-based quantitative computed tomography texture analysis with independent external validation.

    abstract:OBJECTIVE:To develop externally validated, reproducible, and generalizable models for distinguishing three major subtypes of renal cell carcinomas (RCCs) using machine learning-based quantitative computed tomography (CT) texture analysis (qCT-TA). MATERIALS AND METHODS:Sixty-eight RCCs were included in this retrospect...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2018.08.014

    authors: Kocak B,Yardimci AH,Bektas CT,Turkcanoglu MH,Erdim C,Yucetas U,Koca SB,Kilickesmez O

    更新日期:2018-10-01 00:00:00

  • Detection accuracy of in vitro approximal caries by cone beam computed tomography images.

    abstract:AIMS:To evaluate the diagnostic accuracy of approximal carious lesions among five CBCT systems and to assess the effect of detector types employed by different CBCT systems on the accuracy of approximal caries diagnosis. MATERIALS AND METHODS:Thirty-nine extracted non-cavitated human permanent teeth were employed in t...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.05.063

    authors: Qu X,Li G,Zhang Z,Ma X

    更新日期:2011-08-01 00:00:00

  • Clinical value of Doppler ultrasound in the first two months after kidney transplant.

    abstract::The ability of PI measurements to differentiate between acute rejection and ATN was investigated in 37 patients, who were frequently examined by duplex Doppler after kidney transplant. Absolute PI values as well as increase in PI were recorded and the clinical course was correlated with these pulsatility measurements....

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/0720-048x(92)90057-g

    authors: van Leeuwen MS,Hené RJ,Muller AF,Beek FJ,Meyer R,Ganpat R

    更新日期:1992-01-01 00:00:00

  • Risk assessment of osteoradionecrosis associated with periodontitis using 18F-FDG PET/CT.

    abstract:PURPOSE:Osteoradionecrosis (ORN) is a serious complication after radiotherapy (RT), even in the era of intensity modulated radiation therapy (IMRT). The purpose of this study was to evaluate whether 18F-FDG PET/CT can predict ORN associated with periodontal disease in patients with oropharyngeal or oral cavity squamous...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109259

    authors: Ito K,Takumi K,Meibom SK,Qureshi MM,Fujima N,Andreu-Arasa VC,Truong MT,Salama AR,Kaneda T,Sakai O

    更新日期:2020-11-01 00:00:00

  • PET/MRI of the breast.

    abstract::The future clinical use of the combination of positron emission tomography (PET) with 2-Fluoro[F-18]-2-Deoxy-d-Glucose (FDG)and MRI is still unclear. If a patient requires a PET and breast DCE-MRI for staging purposes, both scans can be done in the same visit. In the breast, DCE-MRI is better at lesion detection (sens...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2017.05.006

    authors: Plecha DM,Faulhaber P

    更新日期:2017-09-01 00:00:00

  • Using low tube voltage (80kVp) quadruple phase liver CT for the detection of hepatocellular carcinoma: two-year experience and comparison with Gd-EOB-DTPA enhanced liver MRI.

    abstract:PURPOSE:To validate the diagnostic performance of quadruple phase low tube voltage liver CT through the comparison with Gd-EOB-DTPA enhanced liver MRI for the detection of HCC. MATERIALS AND METHODS:Non-obese patients (38 men, eight women) with 68 HCCs underwent quadruple-phase CT at 16 MDCT (using low tube voltage, 8...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2011.12.033

    authors: Lee CH,Kim KA,Lee J,Park YS,Choi JW,Park CM

    更新日期:2012-04-01 00:00:00

  • T1 mapping of the ischemic myocardium: Review of potential clinical use.

    abstract::Cardiac magnetic resonance imaging (CMR) is an indispensable part of the diagnostic algorithm in cardiology. CMR has become a gold standard in various disorders; moreover, it is well established also as a surrogate end-point in experimental and clinical studies. Particularly, the ability to directly display myocardial...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2016.04.010

    authors: Baxa J,Ferda J,Hromádka M

    更新日期:2016-10-01 00:00:00

  • Usefulness of CT virtual endoscopy in imaging a large esophagorespiratory fistula.

    abstract::A 73-year-old woman with a large esophagorespiratory fistula underwent bronchoscopy and computed tomographic (CT) virtual endoscopy before stenting. Noninvasive CT virtual endoscopy showed the large fistula, and the CT findings agreed with the bronchoscopic findings. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/s0720-048x(99)00100-x

    authors: Sonomura T,Kishi K,Ishii S,Kawai N,Masuda M,Terada M,Nakamine H,Sato M

    更新日期:2000-04-01 00:00:00

  • Mesenteric findings of CT enterography are well correlated with the endoscopic severity of Crohn's disease.

    abstract:BACKGROUND:Maintenance of mucosal healing is a primary goal when treating Crohn's disease (CD). Endoscopy is the most precise method for the assessment of mucosal healing, but is considered overly invasive for patients with CD. In contrast, CT enterography (CTE) is less invasive, but little is known about the correlati...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2016.10.022

    authors: Sakurai T,Katsuno T,Saito K,Yoshihama S,Nakagawa T,Koseki H,Taida T,Ishigami H,Okimoto KI,Maruoka D,Matsumura T,Arai M,Yokosuka O

    更新日期:2017-04-01 00:00:00

  • Prognostic value of pre-treatment DCE-MRI parameters in predicting disease free and overall survival for breast cancer patients undergoing neoadjuvant chemotherapy.

    abstract::The purpose of this study was to investigate whether dynamic contrast enhanced MRI (DCE-MRI) data, both pharmacokinetic and empirical, can predict, prior to neoadjuvant chemotherapy, which patients are likely to have a shorter disease free survival (DFS) and overall survival (OS) interval following surgery. Traditiona...

    journal_title:European journal of radiology

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.ejrad.2008.05.007

    authors: Pickles MD,Manton DJ,Lowry M,Turnbull LW

    更新日期:2009-09-01 00:00:00

  • Hyperintense HCC on hepatobiliary phase images of gadoxetic acid-enhanced MRI: correlation with clinical and pathological features.

    abstract:PURPOSE:To retrospectively determine whether the hyperintense hepatocellular carcinomas (HCCs) seen on the hepatobiliary phase of gadoxetic acid-enhanced MR imaging (EOB-MRI) might have different histologic characteristics from usual hypointense HCCs. MATERIALS AND METHODS:Two hundred three surgically proven HCCs from...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2012.07.021

    authors: Kim JY,Kim MJ,Kim KA,Jeong HT,Park YN

    更新日期:2012-12-01 00:00:00

  • Image quality of mammographic systems.

    abstract::The image quality in mammography was evaluated for all the 56 equipment-image receptor combinations used in Finland with two phantoms containing test objects of three types and different sizes. We obtained 2-8 fold variations for the smallest sizes of the three objects (specks, fibres and masses) visible in the X-ray ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Karila KT

    更新日期:1987-08-01 00:00:00

  • Current concepts in the classification, diagnosis and treatment of vascular anomalies.

    abstract::Patients with extended vascular anomalies may suffer from significant aesthetic and functional impairment and represent a challenge to therapeutic planning, which is best met by an interdisciplinary concept. In agreement with the International Society for the Study of Vascular Anomalies (ISSVA), vascular lesions are c...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2010.04.009

    authors: Ernemann U,Kramer U,Miller S,Bisdas S,Rebmann H,Breuninger H,Zwick C,Hoffmann J

    更新日期:2010-07-01 00:00:00

  • Image quality and radiation dose of single heartbeat 640-slice coronary CT angiography: a comparison between patients with chronic atrial fibrillation and subjects in normal sinus rhythm by propensity analysis.

    abstract:OBJECTIVES:To evaluate image quality and radiation dose of single heartbeat 640-slice coronary CT angiography (CCTA) in patients with chronic Atrial Fibrillation (cAF) in comparison with subjects in normal sinus rhythm. METHODS:A cohort of 71 patients with cAF was matched with 71 subjects in normal sinus rhythm (NSR) ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2014.11.035

    authors: Di Cesare E,Gennarelli A,Di Sibio A,Felli V,Splendiani A,Gravina GL,Masciocchi C

    更新日期:2015-04-01 00:00:00

  • COV is a readily available quantitative indicator of metabolic heterogeneity for predicting survival of patients with early and locally advanced NSCLC manifesting as central lung cancer.

    abstract:OBJECTIVES:The aim of our study was to investigate the value of a simple metabolic heterogeneity parameter, COV (coefficient of variation), by 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in the prognosis prediction of central lung cancer in early and locally advanced non-small-cell lung cancer (NSC...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2020.109338

    authors: Yu T

    更新日期:2020-11-01 00:00:00

  • Para-oesophageal synovial sarcoma.

    abstract::An unusual case of mediastinal synovial sarcoma with secondary invasion of the oesophagus simulating an intra-oesophageal mass is reported. The location and radiological appearance of this tumour are exceptional, and, to the authors' knowledge, have not been reported previously. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Pulpeiro JR,Cruz R,Arenas A,Perez-Espejo G

    更新日期:1988-05-01 00:00:00

  • Pixel-wise derivation of pulmonary regurgitation index could influence clinical decision: A phase-contrast MR imaging study on patients with repaired tetralogy of Fallot.

    abstract:PURPOSE:Regurgitant fraction (RF) measured from 2D phase-contrast MRI has been used as a standard to quantitate the degree of pulmonary regurgitation and serves as a determinant indicator of prognosis for tetralogy of Fallot after surgical repair. This study demonstrated the potential underestimate of RF using the conv...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.05.027

    authors: Wu PH,Chung HW,Wu MT,Ko CW

    更新日期:2017-08-01 00:00:00

  • Modern imaging lymph node staging of the head and neck region.

    abstract::The aim of this paper is to describe the modern imaging methods, their techniques, ability, and performance in staging head and neck lymph nodes. Also, the imaging morphologies of benign and malignant lymph nodes according to the different imaging techniques will be delineated. The imaging techniques of ultrasound inc...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2005.12.040

    authors: Krestan C,Herneth AM,Formanek M,Czerny C

    更新日期:2006-06-01 00:00:00

  • Imaging positron emitting radionuclides generated during radiation therapy.

    abstract::In vivo generated positron emitting radioisotopes, primarily C-11 and N-13, have been documented following therapy with accelerators larger than 10 MeV. Six patients had positron emission tomography 15 to 25 minutes after radiation therapy with a 42 MeV accelerator. Five patients had recurrent colorectal malignancy, a...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Strauss LG,Clorius JH,Kimmig B,Dimitrakopoulou A,Marin-Grez M,Engenhart R,Schraube P

    更新日期:1989-11-01 00:00:00

  • Delayed-enhancement magnetic resonance imaging at 3.0T using 0.15mmol/kg of contrast agent for the assessment of chronic myocardial infarction.

    abstract:OBJECTIVE:A recent international, multicenter, double-blinded, randomized trial shows delayed-enhanced magnetic resonance imaging (DE-MRI) using contrast doses of ≥0.2mmol/kg is effective in the detection and assessment of myocardial infarction (MI), and 0.1mmol/kg is not enough; intermediate doses between 0.1 and 0.2m...

    journal_title:European journal of radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.ejrad.2014.01.012

    authors: Yang J,Ma H,Liu J,Wang C,Shi Y,Xie H,Huo F,Liu F,Lin K

    更新日期:2014-05-01 00:00:00

  • Evaluating the effect of rectal distension on prostate multiparametric MRI image quality.

    abstract:PURPOSE:To evaluate the effect of rectal distension on the quality of anatomical and functional prostate multiparametric (mp) MRI. MATERIALS AND METHODS:Multiparametric (mp) 3T-MRI images of 173 patients were independently evaluated by two radiologists in this retrospective study. Planimetry rectal volumes were derive...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2017.02.029

    authors: Caglic I,Hansen NL,Slough RA,Patterson AJ,Barrett T

    更新日期:2017-05-01 00:00:00

  • Gall bladder infarction: a radiographic mimic of emphysematous cholecystitis.

    abstract::A case is reported in which the typical radiographic appearances of acute emphysematous cholecystitis were due to acute gall bladder infarction following thrombotic occlusion of the superior mesenteric artery. ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:

    authors: Loughran CF,Thind CR

    更新日期:1985-05-01 00:00:00

  • Measurement of canine pancreatic perfusion using dynamic computed tomography: influence of input-output vessels on deconvolution and maximum slope methods.

    abstract:OBJECTIVE:We investigated whether the prerequisite of the maximum slope and deconvolution methods are satisfied in pancreatic perfusion CT and whether the measured parameters between these algorithms are correlated. METHODS:We examined nine beagles injected with iohexol (200 mgI kg(-1)) at 5.0 ml s(-1). The abdominal ...

    journal_title:European journal of radiology

    pub_type: 杂志文章

    doi:10.1016/j.ejrad.2009.06.016

    authors: Kishimoto M,Tsuji Y,Katabami N,Shimizu J,Lee KJ,Iwasaki T,Miyake Y,Yazumi S,Chiba T,Yamada K

    更新日期:2011-01-01 00:00:00

  • Spinal tumors.

    abstract::Spinal tumors are uncommon lesions but may cause significant morbidity in terms of limb dysfunction. In establishing the differential diagnosis for a spinal lesion, location is the most important feature, but the clinical presentation and the patient's age and gender are also important. Magnetic resonance (MR) imaging...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2003.10.021

    authors: Van Goethem JW,van den Hauwe L,Ozsarlak O,De Schepper AM,Parizel PM

    更新日期:2004-05-01 00:00:00

  • Volume perfusion-CT of the liver: insights and applications.

    abstract::The purpose of this article is to provide an up-to-date view on the spectrum of applications of volume perfusion-CT in the liver. Volume perfusion-CT yields important information on liver architecture and function by enabling quantification of dual liver parenchymal blood supply. Additional characterization of diffuse...

    journal_title:European journal of radiology

    pub_type: 杂志文章,评审

    doi:10.1016/j.ejrad.2011.04.010

    authors: Spira D,Schulze M,Sauter A,Brodoefel H,Brechtel K,Claussen C,Horger M

    更新日期:2012-07-01 00:00:00