Multi-Hypergraph Learning for Incomplete Multimodality Data.

Abstract:

:Multi-modality data convey complementary information that can be used to improve the accuracy of prediction models in disease diagnosis. However, effectively integrating multi-modality data remains a challenging problem, especially when the data are incomplete. For instance, more than half of the subjects in the Alzheimer's disease neuroimaging initiative (ADNI) database have no fluorodeoxyglucose positron emission tomography and cerebrospinal fluid data. Currently, there are two commonly used strategies to handle the problem of incomplete data: 1) discard samples having missing features; and 2) impute those missing values via specific techniques. In the first case, a significant amount of useful information is lost and, in the second case, additional noise and artifacts might be introduced into the data. Also, previous studies generally focus on the pairwise relationships among subjects, without considering their underlying complex (e.g., high-order) relationships. To address these issues, in this paper, we propose a multi-hypergraph learning method for dealing with incomplete multimodality data. Specifically, we first construct multiple hypergraphs to represent the high-order relationships among subjects by dividing them into several groups according to the availability of their data modalities. A hypergraph regularized transductive learning method is then applied to these groups for automatic diagnosis of brain diseases. Extensive evaluation of the proposed method using all subjects in the baseline ADNI database indicates that our method achieves promising results in AD/MCI classification, compared with the state-of-the-art methods.

authors

Liu M,Gao Y,Yap PT,Shen D

doi

10.1109/JBHI.2017.2732287

subject

Has Abstract

pub_date

2018-07-01 00:00:00

pages

1197-1208

issue

4

eissn

2168-2194

issn

2168-2208

journal_volume

22

pub_type

杂志文章
  • Cluster-based analysis for personalized stress evaluation using physiological signals.

    abstract::Technology development in wearable sensors and biosignal processing has made it possible to detect human stress from the physiological features. However, the intersubject difference in stress responses presents a major challenge for reliable and accurate stress estimation. This research proposes a novel cluster-based ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章,随机对照试验

    doi:10.1109/JBHI.2014.2311044

    authors: Xu Q,Nwe TL,Guan C

    更新日期:2015-01-01 00:00:00

  • Understanding the Physiological Significance of Four Inertial Gait Features in Multiple Sclerosis.

    abstract::Gait impairment in multiple sclerosis (MS) can result from muscle weakness, physical fatigue, lack of coordination, and other symptoms. Walking speed, as measured by a number of clinician-administered walking tests, is the primary measure of gait impairment used by clinical researchers, but inertial gait features from...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2773629

    authors: Dandu SR,Engelhard MM,Qureshi A,Gong J,Lach JC,Brandt-Pearce M,Goldman MD

    更新日期:2018-01-01 00:00:00

  • Objective study of sensor relevance for automatic cough detection.

    abstract::The development of a system for the automatic, objective, and reliable detection of cough events is a need underlined by the medical literature for years. The benefit of such a tool is clear as it would allow the assessment of pathology severity in chronic cough diseases. Even though some approaches have recently repo...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/jbhi.2013.2239303

    authors: Drugman T,Urbain J,Bauwens N,Chessini R,Valderrama C,Lebecque P,Dutoit T

    更新日期:2013-05-01 00:00:00

  • 40-Hz ASSR for Measuring Depth of Anaesthesia During Induction Phase.

    abstract::This paper proposes an anaesthesia monitoring system that accurately measures the depth of anaesthesia through 40-Hz auditory steady-state response. With accurate and fast depth of anaesthesia measuring, the monitor can reduce the incidence of awareness during surgical operation. The proposed denoising method for extr...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2778140

    authors: Haghighi SJ,Komeili M,Hatzinakos D,Beheiry HE

    更新日期:2018-11-01 00:00:00

  • Accurate Joint-Alignment of Indocyanine Green and Fluorescein Angiograph Sequences for Treatment of Subretinal Lesions.

    abstract::In ophthalmology, aligning images in indocyanine green and fluorescein angiograph sequences is important for the treatment of subretinal lesions. This paper introduces an algorithm that is tailored to align jointly in a common reference space all the images in an angiogram sequence containing both modalities. To overc...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2016.2538265

    authors: Chia-Ling Tsai,Hung-Chuan Hsu,Xin-Chang Wu,Shih-Jen Chen,Wei-Yang Lin

    更新日期:2017-05-01 00:00:00

  • Deep Learning for Fall Detection: Three-Dimensional CNN Combined With LSTM on Video Kinematic Data.

    abstract::Fall detection is an important public healthcare problem. Timely detection could enable instant delivery of medical service to the injured. A popular nonintrusive solution for fall detection is based on videos obtained through ambient camera, and the corresponding methods usually require a large dataset to train a cla...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2018.2808281

    authors: Lu N,Wu Y,Feng L,Song J

    更新日期:2019-01-01 00:00:00

  • Contribution of a Trunk Accelerometer System to the Characterization of Gait in Patients With Mild-to-Moderate Parkinson's Disease.

    abstract:OBJECTIVE:Gait disturbances like shuffling and short steps are obvious at visual observation in patients with advanced Parkinson's disease (PD). However, quantitative methods are increasingly used to evaluate the wide range of gait abnormalities that may occur over the disease course. The goal of this study was to test...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2015.2469540

    authors: Demonceau M,Donneau AF,Croisier JL,Skawiniak E,Boutaayamou M,Maquet D,Garraux G

    更新日期:2015-11-01 00:00:00

  • Optimized Multistable Stochastic Resonance for the Enhancement of Pituitary Microadenoma in MRI.

    abstract::Magnetic resonance imaging (MRI) is the modality of choice as far as imaging diagnosis of pathologies in the pituitary gland is concerned. Furthermore, the advent of dynamic contrast enhanced (DCE) has enhanced the capability of this modality in detecting minute benign but endocrinologically significant tumors called ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2715078

    authors: Singh M,Verma A,Sharma N

    更新日期:2018-05-01 00:00:00

  • A Resampling Based Grid Search Method to Improve Reliability and Robustness of Mixture-Item Response Theory Models of Multimorbid High-Risk Patients.

    abstract::There are many statistics available to the applied statistician for assessing model fit and even more methods for assessing internal and external validity. We detail a useful approach using a grid search technique that balances the internal model consistency with generalizability and can be used with models that natur...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2948734

    authors: Batten AJ,Thorpe J,Piegari RI,Rosland AM

    更新日期:2020-06-01 00:00:00

  • Automatic evaluation of the 30-s chair stand test using inertial/magnetic-based technology in an older prefrail population.

    abstract::The aim of this study was to evaluate the inertial measures of the 30-s chair stand test using modern body-fixed motion sensors. Polynomial data fitting was used to correct the drift effect in the position estimation. Thereafter, the three most important test cycles phases ("impulse," "stand up," and "sit down") were ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2013.2238243

    authors: Millor N,Lecumberri P,Gomez M,Martinez-Ramirez A,Rodriguez-Manas L,Garcia-Garcia FJ,Izquierdo M

    更新日期:2013-07-01 00:00:00

  • The technologically integrated oncosimulator: combining multiscale cancer modeling with information technology in the in silico oncology context.

    abstract::This paper outlines the major components and function of the technologically integrated oncosimulator developed primarily within the Advancing Clinico Genomic Trials on Cancer (ACGT) project. The Oncosimulator is defined as an information technology system simulating in vivo tumor response to therapeutic modalities wi...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2013.2284276

    authors: Stamatakos G,Dionysiou D,Lunzer A,Belleman R,Kolokotroni E,Georgiadi E,Erdt M,Pukacki J,Rüeping S,Giatili S,d'Onofrio A,Sfakianakis S,Marias K,Desmedt C,Tsiknakis M,Graf N

    更新日期:2014-05-01 00:00:00

  • Transfer Learning for Multicenter Classification of Chronic Obstructive Pulmonary Disease.

    abstract::Chronic obstructive pulmonary disease (COPD) is a lung disease that can be quantified using chest computed tomography scans. Recent studies have shown that COPD can be automatically diagnosed using weakly supervised learning of intensity and texture distributions. However, up till now such classifiers have only been e...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2769800

    authors: Cheplygina V,Pena IP,Pedersen JH,Lynch DA,Sorensen L,de Bruijne M

    更新日期:2018-09-01 00:00:00

  • A study on quality assessment for medical ultrasound video compressed via HEVC.

    abstract::The quality of experience and quality of service provided in the healthcare sector are critical in evaluating the reliable delivery of the healthcare services provided. Medical images and videos play a major role in modern e-health services and have become an integral part of medical data communication systems. The qu...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2326891

    authors: Razaak M,Martini MG,Savino K

    更新日期:2014-09-01 00:00:00

  • Unsupervised Bayesian Inference to Fuse Biosignal Sensory Estimates for Personalizing Care.

    abstract::The role of sensing technologies, such as wearables, in delivering precision care is becoming widely acceptable. Given the very large quantities of sensor data that rapidly accumulate, there is a need to employ automated algorithms to label biosignal sensor data. In many real-life clinical applications, no such expert...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2018.2820054

    authors: Zhu T,Pimentel MAF,Clifford GD,Clifton DA

    更新日期:2019-01-01 00:00:00

  • Efficient and Effective Training of COVID-19 Classification Networks With Self-Supervised Dual-Track Learning to Rank.

    abstract::Coronavirus Disease 2019 (COVID-19) has rapidly spread worldwide since first reported. Timely diagnosis of COVID-19 is crucial both for disease control and patient care. Non-contrast thoracic computed tomography (CT) has been identified as an effective tool for the diagnosis, yet the disease outbreak has placed tremen...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3018181

    authors: Li Y,Wei D,Chen J,Cao S,Zhou H,Zhu Y,Wu J,Lan L,Sun W,Qian T,Ma K,Xu H,Zheng Y

    更新日期:2020-10-01 00:00:00

  • Automatic motion analysis system for pyloric flow in ultrasonic videos.

    abstract::Ultrasonography has been widely used to evaluate duodenogastric reflux (DGR). But to the best of our knowledge, no automatic analysis system was developed to realize the quantitative computer-aided analysis. In this paper, we propose a system to perform the automatic detection of DGR in the ultrasonic image sequences ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2013.2272090

    authors: Chen C,Wang Y,Yu J,Zhou Z,Shen L,Chen YQ

    更新日期:2014-01-01 00:00:00

  • Nonnegative matrix factorization for the identification of EMG finger movements: evaluation using matrix analysis.

    abstract::Surface electromyography (sEMG) is widely used in evaluating the functional status of the hand to assist in hand gesture recognition, prosthetics and rehabilitation applications. The sEMG is a noninvasive, easy to record signal of superficial muscles from the skin surface. Considering the nonstationary characteristics...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2326660

    authors: Naik GR,Nguyen HT

    更新日期:2015-03-01 00:00:00

  • User-Intended Doppler Measurement Type Prediction Combining CNNs With Smart Post-Processing.

    abstract::Spectral Doppler measurements are an important part of the standard echocardiographic examination. These measurements give insight into myocardial motion and blood flow providing clinicians with parameters for diagnostic decision making. Many of these measurements are performed automatically with high accuracy, increa...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.3029392

    authors: Gilbert A,Holden M,Eikvil L,Rakhmail M,Babic A,Aase SA,Samset E,McLeod K

    更新日期:2020-10-07 00:00:00

  • A Continuously Updated, Computationally Efficient Stress Recognition Framework Using Electroencephalogram (EEG) by Applying Online Multitask Learning Algorithms (OMTL).

    abstract::Recognizing the factors that cause stress is a crucial step toward early detection of stressors. In this regard, several studies make an effort to recognize individuals' stress using an Electroencephalogram (EEG). However, current EEG-based stress recognition frameworks have several drawbacks. First, they are mostly d...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2018.2870963

    authors: Jebelli H,Mahdi Khalili M,Lee S

    更新日期:2019-09-01 00:00:00

  • A decision-support framework for promoting independent living and ageing well.

    abstract::Artificial intelligence and decision support systems offer a plethora of health monitoring capabilities in ambient assisted living environment. Continuous assessment of health indicators for elderly people living on their own is of utmost importance, so as to prolong their independence and quality of life. Slow varyin...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2336757

    authors: Billis AS,Papageorgiou EI,Frantzidis CA,Tsatali MS,Tsolaki AC,Bamidis PD

    更新日期:2015-01-01 00:00:00

  • Atrial Fibrillation Detection via Accelerometer and Gyroscope of a Smartphone.

    abstract::We present a smartphone-only solution for the detection of atrial fibrillation (AFib), which utilizes the built-in accelerometer and gyroscope sensors [inertial measurement unit, (IMU)] in the detection. Depending on the patient's situation, it is possible to use the developed smartphone application either regularly o...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2688473

    authors: Lahdenoja O,Hurnanen T,Iftikhar Z,Nieminen S,Knuutila T,Saraste A,Kiviniemi T,Vasankari T,Airaksinen J,Pankaala M,Koivisto T

    更新日期:2018-01-01 00:00:00

  • An Adaptive, Data-Driven Personalized Advisor for Increasing Physical Activity.

    abstract::In recent years, there has been growing interest in the use of fitness trackers and smartphone applications for promoting physical activity. Many of these applications use accelerometers to estimate the level of activity that users engage in and provide visual reports of a user's step counts. When provided, most recom...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2018.2879805

    authors: Li Z,Das S,Codella J,Hao T,Lin K,Maduri C,Chen CH

    更新日期:2019-05-01 00:00:00

  • Classification of Opioid Usage Through Semi-Supervised Learning for Total Joint Replacement Patients.

    abstract::Opioid misuse and overdose have become a public health hazard and caused drug addiction and death in the United States due to rapid increase in prescribed and non-prescribed opioid usage. The misuse and overdose are highly related to opioid over-prescription for chronic and acute pain treatment, where a one-size-fits-...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.2992973

    authors: Lee S,Wei S,White V,Bain PA,Baker C,Li J

    更新日期:2021-01-01 00:00:00

  • EMG-Torque Relation in Chronic Stroke: A Novel EMG Complexity Representation With a Linear Electrode Array.

    abstract::This study examines the electromyogram (EMG)-torque relation for chronic stroke survivors using a novel EMG complexity representation. Ten stroke subjects performed a series of submaximal isometric elbow flexion tasks using their affected and contralateral arms, respectively, while a 20-channel linear electrode array ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2016.2626399

    authors: Zhang X,Wang D,Yu Z,Chen X,Li S,Zhou P

    更新日期:2017-11-01 00:00:00

  • A Patient-Centric Health Information Exchange Framework Using Blockchain Technology.

    abstract::Health Information Exchange (HIE) exhibits remarkable benefits for patient care such as improving healthcare quality and expediting coordinated care. The Office of the National Coordinator (ONC) for Health Information Technology is seeking patient-centric HIE designs that shift data ownership from providers to patient...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2020.2993072

    authors: Zhuang Y,Sheets LR,Chen YW,Shae ZY,Tsai JJP,Shyu CR

    更新日期:2020-08-01 00:00:00

  • Assessment of Signal Processing Methods for Measuring the Respiratory Rate in the Neonatal Intensive Care Unit.

    abstract::Knowledge of the pathological instabilities in the breathing pattern can provide valuable insights into the cardiorespiratory status of the critically-ill infant as well as their maturation level. This paper is concerned with the measurement of respiratory rate in premature infants. We compare the rates estimated from...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2019.2898273

    authors: Jorge J,Villarroel M,Chaichulee S,Green G,McCormick K,Tarassenko L

    更新日期:2019-11-01 00:00:00

  • Network-based modeling and intelligent data mining of social media for improving care.

    abstract::Intelligently extracting knowledge from social media has recently attracted great interest from the Biomedical and Health Informatics community to simultaneously improve healthcare outcomes and reduce costs using consumer-generated opinion. We propose a two-step analysis framework that focuses on positive and negative...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2336251

    authors: Akay A,Dragomir A,Erlandsson BE

    更新日期:2015-01-01 00:00:00

  • Tempo-Spatial Compressed Sensing of Organ-on-a-Chip for Pervasive Health.

    abstract::As a micro-engineered biomimetic system to replicate key functions of living organs, organ-on-a-chip (OC) technology provides a high-throughput model for investigating complex cell interactions with both high temporal and spatial resolutions in biological studies. Typically, microscopy and high-speed video cameras are...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2017.2775559

    authors: Song C,Wang A,Lin F,Asmani M,Zhao R,Jin Z,Xiao J,Xu W

    更新日期:2018-03-01 00:00:00

  • PulseGAN: Learning to generate realistic pulse waveforms in remote photoplethysmography.

    abstract::Remote photoplethysmography (rPPG) is a non-contact technique for measuring cardiac signals from facial videos. High-quality rPPG pulse signals are urgently demanded in many fields, such as health monitoring and emotion recognition. However, most of the existing rPPG methods can only be used to get average heart rate ...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2021.3051176

    authors: Song R,Chen H,Cheng J,Li C,Liu Y,Chen X

    更新日期:2021-01-12 00:00:00

  • Exploiting wearable goniometer technology for motion sensing gloves.

    abstract::This paper presents an innovative wearable kinesthetic glove realized with knitted piezoresistive fabric (KPF) sensor technology. The glove is conceived to capture hand movement and gesture by using KPF in a double-layer configuration working as angular sensors (electrogoniometers). The sensing glove prototype is endo...

    journal_title:IEEE journal of biomedical and health informatics

    pub_type: 杂志文章

    doi:10.1109/JBHI.2014.2324293

    authors: Carbonaro N,Dalle Mura G,Lorussi F,Paradiso R,De Rossi D,Tognetti A

    更新日期:2014-11-01 00:00:00