IgG subclasses of FVIII inhibitors in an argentine cohort of severe hemophilia A patients: Analysis by flow cytometry.

Abstract:

INTRODUCTION:FVIII inhibitors consist of a polyclonal population of antibodies. Previous studies have demonstrated different distribution of IgG subclasses. IgG4 was associated to high level of FVIII inhibitors and failure of immune tolerance induction (ITI) treatment. This study monitored the relative distribution of IgG subclasses of anti-FVIII in patients with severe hemophilia A (SHA). METHODS:Anti-FVIII antibodies were measured employing an immunomethod, developed in our laboratory, that combines flow cytometry (FC) with microspheres coupled (FVIII-m) or not (Control-m) to FVIII. Seventy-five patients with SHA were studied, 17 without inhibitors (Group I); 58 with inhibitor history, 13 low responders: (LR: Group II), and 45 high responders (HR: Group III). Eight patients undergoing ITI were also included. RESULTS:We found anti-FVIII antibodies in 11 of 27 patients (40%) without inhibitors and in 45 of 48 with inhibitors at the moment of the study. IgG4 was predominant only in the Group III: P=0.02 in patients with low level of inhibitors and P=0.0001 with high titer of inhibitors. Longitudinal analysis performed on patients undergoing ITI showed a gradual decrease of IgG4 values that was associated to improvement of clinical parameters during treatment. CONCLUSION:We suggest the use of the FC method to supplement functional traditional assays and to help to improve the management of patients with SHA.

journal_name

Int J Lab Hematol

authors

Irigoyen MB,Primiani L,Felippo M,Candela M,de Bracco MME,Galassi NV

doi

10.1111/ijlh.12696

subject

Has Abstract

pub_date

2017-12-01 00:00:00

pages

569-576

issue

6

eissn

1751-5521

issn

1751-553X

journal_volume

39

pub_type

杂志文章
  • Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer.

    abstract:INTRODUCTION:The Hematoflow (Beckman Coulter, USA) is a new automated hematology analyzer, which provides a 16-part white blood cell count (WBC) differential. METHODS:We evaluated the differential WBC count performance of the Hematoflow. 101 blood samples from patients were selected for comparison analysis. RESULTS:T...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01432.x

    authors: Kim JE,Kim BR,Woo KS,Han JY

    更新日期:2012-10-01 00:00:00

  • Use of a capillary specimen in the laboratory to verify a point-of-care international normalized ratio: Avoidance of a venipuncture in a pediatric setting.

    abstract:INTRODUCTION:Point-of-care (POC) international normalized ratio (INR) values above an institutional cutoff are confirmed in the laboratory using a gold standard venous specimen. This can be problematic in a pediatric setting. METHOD:In this study, 449 consecutive POC INR results were compared to an INR performed in th...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12920

    authors: Williams VK

    更新日期:2019-02-01 00:00:00

  • The adsorption of dabigatran is as efficient as addition of idarucizumab to neutralize the drug in routine coagulation assays.

    abstract:INTRODUCTION:The direct thrombin inhibitor dabigatran interferes with thrombophilia screening and with the diagnosis of hemostasis disorders that develop during treatment with the anticoagulant. In vitro addition of idarucizumab, a humanized antibody fragment that binds dabigatran, to plasma samples containing dabigatr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12807

    authors: Jacquemin M,Toelen J,Feyen L,Schoeters J,Van Horenbeeck I,Vanlinthout I,Debasse M,Vanassche T,Peerlinck K,Verhamme P

    更新日期:2018-08-01 00:00:00

  • Different kinetic patterns of BCR-ABL transcript levels in imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response.

    abstract::Bone marrow BCR-ABL transcript levels were monitored serially by real-time quantitative PCR in 46 imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response (CCyR) for a median of 42 months (range: 9-53). Of 41 patients in continuous CCyR, 32 and nine could achieve a >/=3-log (MMo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00962.x

    authors: Qin YZ,Liu YR,Zhu HH,Li JL,Ruan GR,Zhang Y,Jiang Q,Jiang H,Li LD,Chang Y,Huang XJ,Chen SS

    更新日期:2008-08-01 00:00:00

  • Osmotic gradient ektacytometry: A valuable screening test for hereditary spherocytosis and other red blood cell membrane disorders.

    abstract:INTRODUCTION:New generation osmotic gradient ektacytometry has become a powerful procedure for measuring red blood cell deformability and therefore for the diagnosis of red blood cell membrane disorders. In this study, we aim to provide further support to the usefulness of osmotic gradient ektacytometry for the differe...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/ijlh.12746

    authors: Llaudet-Planas E,Vives-Corrons JL,Rizzuto V,Gómez-Ramírez P,Sevilla Navarro J,Coll Sibina MT,García-Bernal M,Ruiz Llobet A,Badell I,Velasco-Puyó P,Dapena JL,Mañú-Pereira MM

    更新日期:2018-02-01 00:00:00

  • Platelet size has diagnostic predictive value for bone marrow metastasis in patients with solid tumors.

    abstract::Though not very common, solid tumor involvement of the bone marrow (BM) may have serious consequences. Recent studies have shown that mean platelet volume (MPV) is a good indicator for BM disease in the differential diagnosis of thrombocytopenia. We investigated the significance of MPV in the diagnosis of BM metastasi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00947.x

    authors: Aksoy S,Kilickap S,Hayran M,Harputluoglu H,Koca E,Dede DS,Erman M,Turker A

    更新日期:2008-06-01 00:00:00

  • ICSH guidelines for the standardization of bone marrow specimens and reports.

    abstract::The bone marrow examination is an essential investigation for the diagnosis and management of many disorders of the blood and bone marrow. The aspirate and trephine biopsy specimens are complementary and when both are obtained, they provide a comprehensive evaluation of the bone marrow. The final interpretation requir...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,实务指引

    doi:10.1111/j.1751-553X.2008.01100.x

    authors: Lee SH,Erber WN,Porwit A,Tomonaga M,Peterson LC,International Council for Standardization In Hematology.

    更新日期:2008-10-01 00:00:00

  • The hematology laboratory's response to the COVID-19 pandemic: A scoping review.

    abstract::The ongoing COVID-19 pandemic has had a profound worldwide impact on the laboratory hematology community. Nevertheless, the pace of COVID-19 hematology-related research has continued to accelerate and has established the role of laboratory hematology data for many purposes including disease prognosis and outcome. The ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13381

    authors: Bell R,Zini G,d'Onofrio G,Rogers HJ,Lee YS,Frater JL

    更新日期:2020-11-12 00:00:00

  • Telomerase activity and telomere length in acute leukemia: correlations with disease progression, subtypes and overall survival.

    abstract::The progressive shortening of telomeres and the activation of telomerase are considered to be one of the important mechanisms in cellular immortalization and disease progression. Bone marrow samples were collected from 148 patients with acute leukemia (AL). Based on the stage of the disease, patients were divided into...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01178.x

    authors: Wang Y,Fang M,Sun X,Sun J

    更新日期:2010-04-01 00:00:00

  • Performance evaluation of the new hematology analyzer Sysmex XN-series.

    abstract:INTRODUCTION:The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. METHODS:The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the ma...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12254

    authors: Seo JY,Lee ST,Kim SH

    更新日期:2015-04-01 00:00:00

  • Evaluation of automated capillary complete blood counts for routine clinical decision making in a large cohort of hematological patients, using Mindray BC-3000 Plus Auto and Sysmex XE-5000 hematology analyzers.

    abstract:INTRODUCTION:Venous blood (VB) sampling for complete blood count (CBC) via venipuncture is the basic method for the daily evaluation of hematological patients. However, several issues during this process, such as venipuncture difficulty and repetitive attempts, may cause pain, phlebitis, hematomas, inadequate sampling,...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13237

    authors: Oudatzis G,Tsagarakis NJ,Paterakis G,Vasileiou P,Xenou E,Maraki P,Pangrati T,Angelopoulou MK,Vassilakopoulos TP,Konstantopoulos K

    更新日期:2020-10-01 00:00:00

  • Technological advances in diagnostic testing for von Willebrand disease: new approaches and challenges.

    abstract::Diagnostic tests for von Willebrand disease (VWD) are important for the assessment of VWD, which is a commonly encountered bleeding disorder worldwide. Technical innovations have been applied to improve the precision and lower limit of detection of von Willebrand factor (VWF) assays, including the ristocetin cofactor ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12220

    authors: Hayward CP,Moffat KA,Graf L

    更新日期:2014-06-01 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • Strategies for basic laboratory diagnostics of the hemoglobinopathies in multi-ethnic societies: interpretation of results and pitfalls.

    abstract::The consistent multi-ethnic migrations of the last decades have considerably changed the epidemiology of the hemoglobinopathies. Healthy carriers of these conditions are present today in many nonendemic parts of the world, and severely affected children are now born where these diseases were previously rare or unknown...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12037

    authors: Giordano PC

    更新日期:2013-10-01 00:00:00

  • A study of disseminated intravascular coagulation in acute leukemia reveals markedly elevated D-dimer levels are a sensitive indicator of acute promyelocytic leukemia.

    abstract:INTRODUCTION:While the presence of disseminated intravascular coagulation (DIC) has been implicated in worse clinical outcome in acute leukemia, the relationship between different subtypes of acute leukemia and the clinicopathologic features of DIC has not been systematically well studied. METHODS:In this study, we re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12636

    authors: Shahmarvand N,Oak JS,Cascio MJ,Alcasid M,Goodman E,Medeiros BC,Arber DA,Zehnder JL,Ohgami RS

    更新日期:2017-08-01 00:00:00

  • Assessing nonvitamin K antagonist oral anticoagulants (NOACs) in the laboratory.

    abstract::Nonvitamin K antagonist oral anticoagulants (NOACs) are being used with increasing frequency due to their safety profile, ease of use, and given that therapeutic monitoring is not required. As these agents have only recently been FDA approved, their effect on routine and specialty coagulation assays is not well apprec...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12350

    authors: Gosselin RC,Adcock DM

    更新日期:2015-05-01 00:00:00

  • The role of automated measurement of red cell subpopulations on the Sysmex XE 5000 analyzer in the differential diagnosis of microcytic anemia.

    abstract::Cell counter-based formulae have been used in the differential diagnosis of microcytic anemia. The measurement of new red cell parameters is now available on the Sysmex XE 5000 analyzer. Derived from the percentages of microcytic and hypochromic red cells, the authors describe the new formula %microcytic-%hypochromic,...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01237.x

    authors: Urrechaga E,Borque L,Escanero JF

    更新日期:2011-02-01 00:00:00

  • Nontransferrin-bound iron in transfused patients with sickle cell disease.

    abstract::The value of nontransferrin-bound iron (NTBI) as an index of iron overload in patients with thalassemia has been evaluated; however, data in patients with sickle cell disease (SCD) is limited. NTBI levels were evaluated in a cross-sectional study of 43 transfused patients with SCD. Patient charts were reviewed for dem...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01224.x

    authors: Inati A,Musallam KM,Cappellini MD,Duca L,Taher AT

    更新日期:2011-04-01 00:00:00

  • Paroxysmal nocturnal haemoglobinuria. Experience over a 10 years period.

    abstract:INTRODUCTION:Paroxysmal nocturnal hemoglobinuria (PNH) is a hemolytic, clonal and acquired disorder of the hematopoietic stem cell with a deficiency of all glycophosphatidyl-inositol (GPI) linked proteins. The aim of this retrospective study was to analyse haematological and biochemical data from 152 patients referred ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12156

    authors: Canalejo K,Riera Cervantes N,Felippo M,Sarandría C,Aixalá M

    更新日期:2014-04-01 00:00:00

  • The automation of routine light transmission platelet aggregation.

    abstract:INTRODUCTION:The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS:We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12161

    authors: Lawrie AS,Kobayashi K,Lane PJ,Mackie IJ,Machin SJ

    更新日期:2014-08-01 00:00:00

  • Hematopoietic stem cell lodgment in the adult bone marrow stem cell niche.

    abstract::Treatment of malignant blood disorders, such as leukemia, that can provide a better chance of long-term remission involves myeloablation followed by transplantation of matched donor hematopoietic stem cells (HSCs). For successful engraftment and re-establishment of hematopoiesis to occur in the recipient, the transpla...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2010.01250.x

    authors: Lam BS,Adams GB

    更新日期:2010-12-01 00:00:00

  • The importance of β globin deletion analysis in the evaluation of patients with β thalassemia.

    abstract:INTRODUCTION:Beta globin deletion/duplication analysis may serve as a useful adjunct to sequence analysis. Our purpose was to develop a robust assay for beta globin deletion/duplication analysis and determine its role in evaluating patients with beta thalassemia. METHODS:A single tube semi-quantitative fluorescent PCR...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01287.x

    authors: Mikula M,Buller-Burckle A,Gallivan M,Sun W,Franklin CR,Strom CM

    更新日期:2011-06-01 00:00:00

  • Standardization of haematology critical results management in adults: an International Council for Standardization in Haematology, ICSH, survey and recommendations.

    abstract:INTRODUCTION:These recommendations are intended to develop a consensus in the previously published papers as to which parameters and what values should be considered critical. A practical guide on the standardization of critical results management in haematology laboratories would be beneficial as part of good laborato...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12526

    authors: Keng TB,De La Salle B,Bourner G,Merino A,Han JY,Kawai Y,Peng MT,McCafferty R,International Council for Standardization in Haematology (ICSH).

    更新日期:2016-10-01 00:00:00

  • Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.

    abstract:INTRODUCTION:The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in pa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01305.x

    authors: Lima-Oliveira G,Lippi G,Salvagno GL,Montagnana M,Scartezini M,Guidi GC,Picheth G

    更新日期:2011-10-01 00:00:00

  • Accuracy of serum transferrin receptor levels in the diagnosis of iron deficiency among hospital patients in a population with a high prevalence of thalassaemia trait.

    abstract::The diagnosis of iron deficiency in hospital patients can be difficult in the presence of inflammation. A raised serum transferrin receptor (sTfR) level is useful as a marker of iron deficiency as it is unaffected by inflammation. However, diseases that cause an increase in erythropoietic activity can also result in a...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00982.x

    authors: Ong KH,Tan HL,Tam LP,Hawkins RC,Kuperan P

    更新日期:2008-12-01 00:00:00

  • Association of Janus kinase 2 (JAK2) polymorphisms with acute leukemia susceptibility.

    abstract:INTRODUCTION:Aberrant activation of Janus kinase (JAK)/signal transducer and activator of transcription (STAT) pathway leads to deregulated proliferation, differentiation, or apoptosis of normal cells. One of the members of this family, JAK2, plays a very important role in metabolizing carcinogens and medications. This...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01386.x

    authors: Zhong Y,Wu J,Ma R,Cao H,Wang Z,Ding J,Cheng L,Feng J,Chen B

    更新日期:2012-06-01 00:00:00

  • Upregulation of long noncoding RNA Lnc-IRF2-3 and Lnc-ZNF667-AS1 is associated with poor survival in B-chronic lymphocytic leukemia.

    abstract:BACKGROUND:Lnc-IRF2-3 and Lnc-ZNF667-AS1 were recently studied as a positive biomarker for many tumor cells. However, experimental studies found that they are associated with worse outcomes in B-CLL. METHODS:A prospective case study was conducted on 135 B-CLL patients that were compared to thirty healthy controls. The...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13167

    authors: El-Khazragy N,Esmaiel MA,Mohamed MM,Hassan NS

    更新日期:2020-06-01 00:00:00

  • The presence of leukaemia-associated phenotypes is an independent predictor of induction failure in acute myeloid leukaemia.

    abstract::Immunophenotyping of acute myeloid leukaemia (AML) has controversial implications with regards to prognosis. The aims of the present study were to determine the frequency of leukaemia-associated phenotypes (LAP) in AML and to correlate their presence with response to induction chemotherapy. We analysed bone marrow sam...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01003.x

    authors: Al-Mawali A,To LB,Gillis D,Hissaria P,Mundy J,Lewis I

    更新日期:2009-02-01 00:00:00

  • Quantification of hemoglobin Constant Spring in heterozygote and homozygote by a capillary electrophoresis method.

    abstract:INTRODUCTION:Capillary electrophoresis (CE) is a high-resolution method for detection of hemoglobin Constant Spring (Hb CS). METHODS:The levels of Hb CS quantified by CE were compared among three groups of samples including heterozygote and homozygote of Hb CS as well as Hb H-CS disease classified by DNA molecular dia...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01371.x

    authors: Pornprasert S,Panyasai S,Waneesorn J,Kongthai K,Singboottra P

    更新日期:2012-04-01 00:00:00

  • Flow cytometry data analysis: Recent tools and algorithms.

    abstract::Flow cytometry (FCM) allows scientists to rapidly quantify up to 50 parameters for millions of cells per sample. The bottleneck in the application of the technology is data analysis, and the high number of parameters measured by the current generation of instruments requires the use of advanced computational algorithm...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13016

    authors: Montante S,Brinkman RR

    更新日期:2019-05-01 00:00:00