Application of addition-cured silicone denture relining materials to adjust mouthguards.

Abstract:

:The purposes of this study were to examine the shock absorption capability of addition-cured silicone denture relining materials and the bonding strength of addition-cured silicone denture relining materials and a commercial mouthguard material to determine its applicability to mouthguard adjustment. Two addition-cured silicone denture relining materials and eleven commercial mouthguard materials were selected as test materials. The impact test was applied by a free-falling steel ball. On the other hand, bonding strength was determined by a delamination test. After prepared surface treatments using acrylic resin on MG sheet surface, 2 types of addition-cured silicone denture relining materials were glued to MG surface. The peak intensity, the time to peak intensity from the onset of the transmitted force and bonding strength were statistically analyzed using ANOVA and Tukey's honest significant difference post hoc test (p<0.05). These results suggest that the silicone denture relining materials could be clinically applicable as a mouthguard adjustment material.

journal_name

Dent Mater J

journal_title

Dental materials journal

authors

Fukasawa S,Churei H,Chowdhury RU,Shirako T,Shahrin S,Shrestha A,Wada T,Uo M,Takahashi H,Ueno T

doi

10.4012/dmj.2015-378

subject

Has Abstract

pub_date

2016-01-01 00:00:00

pages

635-43

issue

4

eissn

0287-4547

issn

1881-1361

journal_volume

35

pub_type

杂志文章
  • Bonding durability between orthodontic brackets and human enamel treated with megabond self-etching primer using 4-META/MMA-TBB resin cement.

    abstract::The purpose of this study was to determine the bonding durability when a Megabond self-etching primer is used with 4-META/MMA-TBB resin to bond metal orthodontic brackets to human premolar enamel. Three conditions of enamel were prepared: Megabond self-etching primer without saliva contamination, Megabond self-etching...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.251

    authors: Sirirungrojying S,Hayakawa T,Saito K,Meguro D,Nemoto K,Kasai K

    更新日期:2004-09-01 00:00:00

  • A study of in vivo degradation of two vital home bleaching gels.

    abstract::This study investigated hydrogen peroxide (H2O2) concentration of two home bleaching gels, in their dispensing syringes and their degradation in vivo in intraoral bleaching trays. Two bleaching gels were studied, 7.5% hydrogen peroxide (HP) and 20% carbamide peroxide (CP). The concentration of H2O2 was determined in d...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2012-317

    authors: Alonso De La Peña V,Rodriguez Carreira A,Corral Aneiros R,López Ratón M,Guitián Rivera F

    更新日期:2013-01-01 00:00:00

  • Micro computed tomography evaluation of the Self-adjusting file and ProTaper Universal system on curved mandibular molars.

    abstract::The aim of this investigation was to compare the cleaning and shaping efficiency of Self-adjusting file and Protaper, and to assess the correlation between root canal curvature and working time in mandibular molars using micro-computed tomography. Twenty extracted mandibular molars instrumented with Protaper and Self-...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2016-255

    authors: Serefoglu B,Piskin B

    更新日期:2017-09-26 00:00:00

  • Influence of three specimen fixation modes on the micro-tensile bond strength of adhesives to dentin.

    abstract::The aim of this study was to investigate in how far the way the specimen is fixed to the testing device influences the micro-tensile bond strength of adhesives to dentin. Compared to a flat jig, a notched jig enables the specimen to be aligned easier and more accurately perpendicular to the interface, thereby concentr...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.694

    authors: Poitevin A,De Munck J,Van Landuyt K,Coutinho E,Peumans M,Lambrechts P,Van Meerbeek B

    更新日期:2007-09-01 00:00:00

  • Effect of thermal misfit between different veneering ceramics and zirconia frameworks on in vitro fracture load of single crowns.

    abstract::Thermal misfit is deemed as one reason for the chipping of veneered zirconia restorations. Aim of the present study was to assess the effect of thermal misfit on the fracture load of veneered zirconia frameworks and to evaluate the applicability of a universal veneering ceramic for both zirconia and titanium framework...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.26.766

    authors: Fischer J,Stawarczyk B,Tomic M,Strub JR,Hämmerle CH

    更新日期:2007-11-01 00:00:00

  • Influence of resin coating materials on Porphyromonas gingivalis attachment.

    abstract::Resin coating materials have been used for composite resin or provisional restoration in order to prevent plaque accumulation on their surfaces. However, it is not clear whether the coating materials influence attachment of periodontal bacteria. Therefore, we investigated the effect of resin coating materials on the a...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2011-164

    authors: Kumada A,Matsuka Y,Mine A,Ono M,Uehara J,Sonoi N,Ito T,Takashiba S,Kuboki T

    更新日期:2012-02-03 00:00:00

  • Spectroscopic characterization of enamel surfaces irradiated with Er:YAG laser.

    abstract::The purpose of this study was to investigate the effect of laser irradiation on the enamel surface spectroscopically. Polished bovine enamel surface was irradiated with an Er:YAG laser apparatus and chemically analyzed using X-ray photoelectron spectroscopy (XPS). XPS detected core electron peaks such as carbon (C 1s)...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.214

    authors: Mine A,Yoshida Y,Suzuki K,Nakayama Y,Yatani H,Kuboki T

    更新日期:2006-06-01 00:00:00

  • Microstructure and homogeneity of dental porcelain frits.

    abstract::The microstructure and homogeneity of three commercial dentin and incisal unfired porcelain frits (one conventional and two ultra-low fusing types, fused-to metal were analyzed by X-ray diffractometry, scanning electron microspectroscopy, and wavelength- and energy dispersive X-ray microspectroscopy. The average conte...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.17.264

    authors: Ban S,Matsuo K,Mizutani N,Iwase H,Kani T,Hasegawa J

    更新日期:1998-12-01 00:00:00

  • Effects of fluoride and dissolved oxygen concentrations on the corrosion behavior of pure titanium and titanium alloys.

    abstract::The effects of dissolved-oxygen concentration and fluoride concentration on the corrosion behaviors of commercial pure titanium, Ti-6Al-4V and Ti-6Al-7Nb alloys and experimentally produced Ti-0.2Pd and Ti-0.5Pt alloys were examined using the corrosion potential measurements. The amount of dissolved Ti was analyzed by ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.83

    authors: Nakagawa M,Matsuya S,Udoh K

    更新日期:2002-06-01 00:00:00

  • Microhardness evaluation of resin composites polymerized by three different light sources.

    abstract::This study examined the surface microhardness of four kinds of resin composites with different fillers and resin matrices. Ten specimens of 2 mm thickness and 4 mm diameter of each resin composite were polymerized using a halogen light, a blue light-emitted diode, and a plasma arc unit. Microhardness evaluation was pe...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:

    authors: Hubbezoğlu I,Bolayir G,Doğan OM,Doğan A,Ozer A,Bek B

    更新日期:2007-11-01 00:00:00

  • Radiopacity of experimental composite resins containing radiopaque materials.

    abstract::This study aimed to investigate the relationship between the radiopacity of an experimental light-cured composite resin and the amount and type of its radiopaque material: Ti, SrCO3, ZrO2, BaSO4, or Bi2O3. Radiopacity of each material was evaluated in terms of aluminum equivalent thickness using an aluminum step wedge...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.24.315

    authors: Aoyagi Y,Takahashi H,Iwasaki N,Honda E,Kurabayashi T

    更新日期:2005-09-01 00:00:00

  • Comparative evaluation of various miniplate systems for the repair of mandibular corpus fractures.

    abstract::Miniplates have been used during the last decade to facilitate stability between bony fragments in the maxillofacial region and are currently the preferred surgical method for the fixation of fractures and osteotomies. The aim of this study was to evaluate and compare the biomechanical behaviors of six different types...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-315

    authors: Ergun S,Ofluoğlu D,Saruhanoğlu A,Karataşli B,Deniz E,Özel S,Tanyeri H

    更新日期:2014-01-01 00:00:00

  • High temperature characteristics and solidification microstructures of dental metallic materials. Part II. ADAS Type 3 gold alloy.

    abstract::Previously, high temperature properties of the silver-palladium-copper-gold alloy were investigated. In this study, the thermal expansion percentage and coefficient, and high temperature strengths of ADAS Type 3 gold alloy were investigated up to the liquidus temperature. Furthermore, microstructural and compositional...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.81

    authors: Nagasawa S,Yoshida T,Terashima N,Mizoguchi T,Yagasaki H,Kamijo K,Ito M,Platt JA,Oshida Y

    更新日期:2004-06-01 00:00:00

  • Nanostructure evaluation of healthy and fluorotic dentin by atomic force microscopy before and after phosphoric acid etching.

    abstract::The aim was to characterize by atomic force microscopy (AFM) the nanostructure of human dentin surfaces affected by dental fluorosis (DF) before and after phosphoric acid etching. This study included 240 human dentin samples classified according to the severity of DF, which were divided into four groups using the Thyl...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-023

    authors: Zavala-Alonso V,Aguilera-Flores R,Patiño-Marin N,Martinez-Castañon GA,Anusavice KJ,Loyola-Rodriguez JP

    更新日期:2011-01-01 00:00:00

  • Effect of dentin cleansers on the bonding efficacy of dentin adhesive.

    abstract::The relation between the bonding efficacy of the dentin adhesive and the physical change of the dentin after treatment with various dentin cleansers was investigated. The dentin surface was cleaned with one of the seven experimental dentin cleansers, 5, 10, 20, 30 and 40% of the phosphoric acid, neutralized 0.5 M EDTA...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.8.76

    authors: Chiba M,Itoh K,Wakumoto S

    更新日期:1989-06-01 00:00:00

  • Calcium-ion incorporation into titanium surfaces accompanied by electrochemical apatite-deposition.

    abstract::The depths of calcium-ion incorporation into a commercially pure titanium and an experimental beta-type titanium alloy were determined using Auger electron spectroscopy. After the electrochemical deposition of apatite, new compositional gradients appeared in the profiles in which the Ca and P concentrations gradually ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.21.306

    authors: Ban S,Kamiya A,Sonoda T

    更新日期:2002-12-01 00:00:00

  • Influence of filling technique and curing mode on the bond strengths of composite cores to pulpal floor dentin.

    abstract::This study evaluated the influence of filling technique and curing mode on the microtensile bond strengths (MTBS) of composite cores to pulpal floor dentin. Access cavities of human molars with pulpal floor dentin were restored with a two-step self-etch adhesive system, Clearfil Liner Bond 2V and a composite core, Cle...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2009-104

    authors: Ariyoshi M,Nikaido T,Foxton RM,Tagami J

    更新日期:2010-10-01 00:00:00

  • Application of thermography in dentistry--visualization of temperature distribution on oral tissues.

    abstract::The purpose of this study was to devise and propose appropriate conditions for the photographing of thermal images in the oral cavity and to evaluate which thermography techniques can be applied to dentistry by evaluating the differences in temperature among oral tissues. Thermal images of oral cavities of 20 voluntee...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.22.436

    authors: Komoriyama M,Nomoto R,Tanaka R,Hosoya N,Gomi K,Iino F,Yashima A,Takayama Y,Tsuruta M,Tokiwa H,Kawasaki K,Arai T,Hosoi T,Hirashita A,Hirano S

    更新日期:2003-12-01 00:00:00

  • Effect of adding spherical silica filler on physico-mechanical properties of resin modified glass-ionomer cement.

    abstract::This study investigated the effects of spherical silica fillers on the physical and mechanical properties of resin-modified glass-ionomer cement (RMGIC). Specimens were fabricated by mixing untreated (UF) or silanized (SF) spherical silica filler into the powder of a commercially prepared RMGIC. The original RMGIC and...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.23.146

    authors: Tjandrawinata R,Irie M,Yoshida Y,Suzuki K

    更新日期:2004-06-01 00:00:00

  • The extent of polymerization of Class II light-cured composite resin restorations; effects of incremental placement technique, exposure time and heating for resin inlays.

    abstract::The extent of polymerization of light-cured composite resins cured in relatively large class II cavities was estimated by measuring Knoop hardness on sectioned surfaces of resin restorations. The influences of the incremental placement technique, exposure time, and post-curing of resin inlay on the extent of polymeriz...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.12.159

    authors: Hirabayashi S,Hood JA,Hirasawa T

    更新日期:1993-12-01 00:00:00

  • Analysis of fracture surface of titanium-porcelain bonding by electron spectroscopy for chemical analysis.

    abstract::Three commercially available porcelains bonded to titanium were evaluated to determine the weakest zone of the titanium-porcelain bonding structures. Tensile bond tests were performed for these specimens (NO, DU, and VI) and for Ni-Cr alloy-porcelain bonding samples that served as controls. The maximum bond strengths ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-263

    authors: Kannari Y,Endo K,Ida Y,Ochi M,Ohno H

    更新日期:2014-01-01 00:00:00

  • Grindability of alpha-case formed on cast titanium.

    abstract::The hardened alpha-case (alpha-case) layer inevitably forms on the surface of titanium castings when prepared by investment casting. Because the hardness of the alpha-case is incomparable to that of the interior structure, the perception exists that the alpha-case is difficult to remove during cutting, grinding and po...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.28.587

    authors: Koike M,Jacobson D,Chan KS,Okabe T

    更新日期:2009-09-01 00:00:00

  • Effects of a barbituric acid/CuCl2 initiator system on resin adhesion to dentin.

    abstract::The effectiveness of a barbituric acid/copper (II) chloride initiator system in dentin was examined in terms of the effects of barbituric acid structures and dentin conditioners on bond strength. Curing times and tensile bond strengths to bovine dentin were measured for PMMA/MMA resins in conjunction with initiators c...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.14.221

    authors: Suzuki A,Imai Y

    更新日期:1995-12-01 00:00:00

  • Stress analysis of endodontically treated anterior teeth restored with different types of post material.

    abstract::Finite element analysis was performed to evaluate stress distribution in maxillary central incisors treated endodontically and restored with a post and an all-ceramic crown. Tensile stress at tooth root was analyzed using two-dimensional finite element models with different post diameters and lengths. One post length ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.25.145

    authors: Nakamura T,Ohyama T,Waki T,Kinuta S,Wakabayashi K,Mutobe Y,Takano N,Yatani H

    更新日期:2006-03-01 00:00:00

  • The effects of glass ionomer and flowable composite liners on the fracture resistance of open-sandwich class II restorations.

    abstract::This in vitro study aimed to investigate the effects of glass-ionomer and flowable composite liners on the fracture resistance of Class II amalgam and composite restorations. Group 1 cavities were restored with amalgam and Group 4 cavities with nanofill composite after the application of a dentin-bonding agent. For th...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2013-053

    authors: Güray Efes B,Yaman BC,Gümüştaş B,Tıryakı M

    更新日期:2013-01-01 00:00:00

  • Effect of different beverages on the color stability and degree of conversion of nano and microhybrid composites.

    abstract::This study sought to evaluate the effects of different staining solutions on the colour stability of nanocomposites compared with microhybrid resin and to evaluate the degree of conversion of these two materials. Two different shades of two different composites were cured in polytetraflouroethylene disk rings. Coffee,...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2011-267

    authors: Al Kheraif AA,Qasim SS,Ramakrishnaiah R,Ihtesham ur Rehman

    更新日期:2013-01-01 00:00:00

  • Novel, multi-purpose, PMMA-type adhesive resin with newly synthesized microcapsule of radical polymerization initiators.

    abstract::The behavior of microencapsulated polymerization initiators in dental adhesives is unknown. This study investigated the effects of new microencapsulated initiators in novel, multi-purpose, PMMA-type adhesive resin on the bonding performance and polymerization reactivity. Microencapsulated BPO and 1,3,5-trimethylbarbit...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.27.35

    authors: Fuchigami K,Ikemura K,Ichizawa K

    更新日期:2008-01-01 00:00:00

  • Antibacterial activity of composite resin with glass-ionomer filler particles.

    abstract::The purpose of this study was to examine the antibacterial activity of composite resin with glass-ionomer filler particles versus that of contemporary commercial composite resins. Three composite resins were used: Beautifil II (containing S-PRG filler), Clearfil AP-X, and Filtek Z250. Resin blocks were bonded to maxil...

    journal_title:Dental materials journal

    pub_type: 杂志文章,随机对照试验

    doi:10.4012/dmj.2009-050

    authors: Saku S,Kotake H,Scougall-Vilchis RJ,Ohashi S,Hotta M,Horiuchi S,Hamada K,Asaoka K,Tanaka E,Yamamoto K

    更新日期:2010-03-01 00:00:00

  • Effects of polishing on surface roughness and hardness of glass-fiber-reinforced polypropylene.

    abstract::Removable partial dentures (RPDs) with resin-clasp retentive parts, which are known as non-metal-clasp dentures (NMCDs), have been used as alternatives for conventional RPDs with metal clasp, in case of aesthetic prosthodontic treatments. In this study, a profilometer and dynamic micro-indentation tests were used to i...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.2018-012

    authors: Tanimoto Y,Nagakura M

    更新日期:2018-11-30 00:00:00

  • New partition technique for two-chamber pressure casting unit for titanium.

    abstract::Although titanium has been widely used in prosthetic appliances, such as cast removable partial denture frameworks, high quality castings are still difficult to obtain. This study proposes a new partition technique using a metal foil for improving castability of a two-chamber pressure casting unit. The metal foil was ...

    journal_title:Dental materials journal

    pub_type: 杂志文章

    doi:10.4012/dmj.19.307

    authors: Watanabe K,Okawa S,Kanatani M,Nakano S,Miyakawa O,Kobayashi M

    更新日期:2000-09-01 00:00:00