Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

Abstract:

INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a prospective cohort of 59 samples from newly diagnosed patients eligible for high-dose therapy (HDT) and 67 samples from previous HDT patients with progressive disease. We used Affymetrix Human Gene 1.1 ST microarrays for GEP. Nine GEP risk signatures were translated by probe set match and applied to our data in multivariate Cox regression analysis for progression-free survival and overall survival in combination with clinical, cytogenetic and biochemical risk markers, including the International Staging System (ISS). RESULTS:Median follow-up was 66 months (range 42-87). Various translated GEP risk signatures or combinations hereof were significantly correlated with survival: among newly diagnosed patients mainly in combination with cytogenetic high-risk markers and among relapsed patients mainly in combination with ISS stage III. CONCLUSION:Translated GEP risk signatures maintain significant prognostic power in HDT myeloma patients. We suggest probe set matching for GEP risk signature translation as part of the efforts towards a microarray-independent GEP risk standard. (ClicinalTrials.gov identifier: NCT00639054).

journal_name

Int J Lab Hematol

authors

Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

doi

10.1111/ijlh.12486

subject

Has Abstract

pub_date

2016-06-01 00:00:00

pages

298-307

issue

3

eissn

1751-5521

issn

1751-553X

journal_volume

38

pub_type

临床试验,杂志文章,多中心研究
  • Abrogation of red blood cell G6PD enzyme activity through Heat treatment: development of survey material for the UK NEQAS G6PD scheme.

    abstract:INTRODUCTION:Participation in external quality assessment (EQA) is central to the maintenance of high-quality laboratory results in patient diagnosis and clinical trials. Laboratories in the TAF112582 DETECTIVE study (ClinicalTrials.gov identifier: NCT01376167) are enrolled in the United Kingdom National Quality Assess...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12627

    authors: Roper DR,De la Salle B,Soni V,Fletcher K,Green JA

    更新日期:2017-06-01 00:00:00

  • Acute myeloid leukaemia: How to combine multiple tools.

    abstract::The pathogenesis of acute myeloid leukaemias (AML) frequently requires at least 3 mutations in different cellular pathways. In many cases, mutations in proliferation/survival mechanisms and differentiation pathways are involved. Genetic aberrations explain the pathogenesis of AML, provide prognostic criteria and guide...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12831

    authors: Merino A,Boldú L,Ermens A

    更新日期:2018-05-01 00:00:00

  • Assessing maternal clotting function with novel global coagulation assays: A prospective pilot study.

    abstract:INTRODUCTION:Women are at higher risk of venous thromboembolism (VTE) during pregnancy and the puerperium. Global coagulation assays (GCAs), including thromboelastography (TEG), thrombin generation using the calibrated automated thrombogram (CAT) and fibrin generation using the overall haemostatic potential assay (OHP)...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13389

    authors: O'Keefe D,Lim HY,Tham J,Ho P,Hui L

    更新日期:2020-11-10 00:00:00

  • The automation of routine light transmission platelet aggregation.

    abstract:INTRODUCTION:The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS:We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12161

    authors: Lawrie AS,Kobayashi K,Lane PJ,Mackie IJ,Machin SJ

    更新日期:2014-08-01 00:00:00

  • CD34, RAB20, PU.1 and GFI1 mRNA expression in myelodysplastic syndrome.

    abstract::Myelodysplastic syndrome (MDS) with hypocellular bone marrow (BM) is often difficult to distinguish from aplastic anemia (AA). Furthermore, the diagnosis of MDS with low blast counts and normal karyotype may be problematic. These issues highlight the need for a reliable marker for the diagnosis of MDS. This study was ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01056.x

    authors: Huh HJ,Chae SL,Lee M,Hong KS,Mun YC,Seong CM,Chung WS,Huh JW

    更新日期:2009-06-01 00:00:00

  • Flow cytometry in the diagnosis of mature B-cell lymphoproliferative disorders.

    abstract::B-lineage lymphoproliferative disorders (LPD) are rather frequent diseases, associated with specific clinical or biological features but also sometimes of fortuitous discovery. Multiparameter flow cytometry plays a major role for a rapid diagnostic indication, on peripheral blood or bone marrow samples in most instanc...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13170

    authors: Debord C,Wuillème S,Eveillard M,Theisen O,Godon C,Le Bris Y,Béné MC

    更新日期:2020-06-01 00:00:00

  • Entonox as a sedative for bone marrow aspiration and biopsy.

    abstract::Bone marrow aspiration and biopsy can be a painful procedure. Sedation techniques may make this investigation more acceptable to patients, but have the potential to cause life-threatening complications, as well as requiring additional staff and equipment for safe administration. We assessed the use of Entonox, a 50 : ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1751-553X.2007.00905.x

    authors: Gudgin EJ,Besser MW,Craig JI

    更新日期:2008-02-01 00:00:00

  • Multicentric evaluation of the new HemosIL Acustar® chemiluminescence ADAMTS13 activity assay.

    abstract:INTRODUCTION:Thrombotic thrombocytopenic purpura (TTP) is a rare life-threatening thrombotic microangiopathy (TMA) characterized by the severe deficiency of ADAMTS13 activity (<10%). Rapid ADAMTS13 testing is crucial for early diagnosis and optimal management of TTP patients and other TMAs. The objective of this study ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13414

    authors: Pascual C,Nieto JM,Fidalgo T,Seguí IG,Díaz-Ricart M,Docampo MF,Del Rio J,Salinas R

    更新日期:2020-12-02 00:00:00

  • Technological advances in diagnostic testing for von Willebrand disease: new approaches and challenges.

    abstract::Diagnostic tests for von Willebrand disease (VWD) are important for the assessment of VWD, which is a commonly encountered bleeding disorder worldwide. Technical innovations have been applied to improve the precision and lower limit of detection of von Willebrand factor (VWF) assays, including the ristocetin cofactor ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12220

    authors: Hayward CP,Moffat KA,Graf L

    更新日期:2014-06-01 00:00:00

  • Hemostasis critical values among Iranian clinical laboratories "National Survey of 157 Clinical Laboratories".

    abstract:BACKGROUND:Immediate reporting of critical values or test results significantly outside the normal range has a growing role in the management of patients, especially in life-threatening conditions. Due to the lack of international consensus, diverse approaches are used for determination of thresholds, reporting, docume...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13109

    authors: Dorgalaleh A,Shiravand Y,Dabbagh A,Tabibian S,Hosseini MS,Mansouri Tourghabeh H,Rashidpanah J,Narouei F,Shams M,Gholami MS,Saneei Moghaddam E,Shahreki H

    更新日期:2019-12-01 00:00:00

  • The importance of β globin deletion analysis in the evaluation of patients with β thalassemia.

    abstract:INTRODUCTION:Beta globin deletion/duplication analysis may serve as a useful adjunct to sequence analysis. Our purpose was to develop a robust assay for beta globin deletion/duplication analysis and determine its role in evaluating patients with beta thalassemia. METHODS:A single tube semi-quantitative fluorescent PCR...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01287.x

    authors: Mikula M,Buller-Burckle A,Gallivan M,Sun W,Franklin CR,Strom CM

    更新日期:2011-06-01 00:00:00

  • JAK2V617F mutation in patients with thrombosis: to screen or not to screen?

    abstract:INTRODUCTION:Thrombotic complications are a main concern in patients with myeloproliferative neoplasms. Recently, a gain-of-function mutation of the gene encoding the JAK2 tyrosine kinase that results in a valine-to-phenylalanine substitution at position 617 (V617F) has been described. Since the description of the JAK2...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2010.01275.x

    authors: Xavier SG,Gadelha T,Rezende SM,Zalcberg IR,Spector N

    更新日期:2011-04-01 00:00:00

  • Analysis of polymorphisms of TNF-α, LT-α, IL-10, IL-12 and CTLA-4 in patients with warm autoimmune haemolytic anaemia.

    abstract:INTRODUCTION:Autoimmune haemolytic anaemia (AIHA) is defined as the increased destruction of red blood cells (RBCs) in the presence of anti-RBC autoantibodies and/or complement. Its pathogenesis is multifactorial and includes changes in mechanisms of cytokine production and functionality. A number of recent studies hav...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01400.x

    authors: D'Abronzo LS,Barros MM,Bordin JO,Figueiredo MS

    更新日期:2012-08-01 00:00:00

  • Live remote digital microscopy in peripheral blood smear evaluation: Intraobserver concordance and experience.

    abstract:INTRODUCTION:Peripheral blood smear (PBS) review is a routine laboratory test which requires pathologist's interpretation when abnormal indices, atypical cells, or critical findings are identified. Real-time remote digital microscopy (DM) can potentially facilitate rapid review when an on-site pathologist is not availa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12914

    authors: Haninger DM,Nassiri M,Settembre ED,Zhang S,Zhou J

    更新日期:2018-12-01 00:00:00

  • Red cell membrane disorders.

    abstract::Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12657

    authors: Narla J,Mohandas N

    更新日期:2017-05-01 00:00:00

  • Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.

    abstract::The PENTRA 60C(+) hematology analyzer provides a complete blood cell (CBC) count, including a five-part differential (5-DIFF) count and two leukocyte subpopulations, i.e. large immature cells (LIC's) and atypical lymphocytes (ALY's). We evaluated its analytical performance and assessed agreement with the ADVIA 2120, i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01011.x

    authors: Guerti K,Vertessen F,Daniëls L,Van Der Planken M

    更新日期:2009-04-01 00:00:00

  • Blood parameters of preterm neonates: postnatal evolution according to gestational age.

    abstract:INTRODUCTION:The blood count provides qualitative and quantitative essential information on bloodlines. Reference hematologic parameters have been established in children and neonates, but few data are available regarding the premature population during the first month of life. The main objective of this study was to e...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12629

    authors: Roudil P,Vasselon C,Trombert-Paviot B,Berger C,Patural H

    更新日期:2017-06-01 00:00:00

  • A level-headed approach to measuring direct oral anticoagulants: A 2-year retrospective analysis of DOAC levels from a tertiary UK centre.

    abstract:INTRODUCTION:Direct oral anticoagulants (DOAC) are commonly prescribed and measuring drug levels may be useful in a number of contexts. However, data on DOAC level measurement and their clinical utility in real-world studies are limited. METHODS:We carried out a 2-year retrospective cohort study of DOAC levels measure...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12944

    authors: Denny NDR,Keighley L,Siganporia Z,Thachil J,Nash MJ

    更新日期:2019-04-01 00:00:00

  • Usefulness of thyrogastric immune features as predictors of pernicious anaemia that lacks intrinsic factor antibody.

    abstract:INTRODUCTION:The study aims to evaluate the diagnostic utility of thyrogastric immune features in the identification of intrinsic factor antibody negative (IFA -ve) pernicious anaemia (PA) patients. METHODS:Clinico-pathological features of 'intrinsic factor antibody positive (IFA +ve) PA' and 'IFA -ve presumed PA' Chi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01295.x

    authors: Chan J,Chan HY

    更新日期:2011-08-01 00:00:00

  • The applicability of multiparameter flow cytometry for the detection of minimal residual disease using different-from-normal panels to predict relapse in patients with acute myeloid leukemia after allogeneic transplantation.

    abstract:BACKGROUND:The MRD status detected using multiparameter flow cytometry (MFC) before allogeneic hematopoietic stem cell transplantation (allo-HSCT) has crucial prognostic value for patients with acute myeloid leukemia (AML) in morphologic complete remission (CR). We designed a novel panel of antibodies to identify aberr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13070

    authors: Wang Z,Guo M,Zhang Y,Xu S,Cheng H,Wu J,Zhang W,Hu X,Yang J,Wang J,Tang G

    更新日期:2019-10-01 00:00:00

  • Strategies for basic laboratory diagnostics of the hemoglobinopathies in multi-ethnic societies: interpretation of results and pitfalls.

    abstract::The consistent multi-ethnic migrations of the last decades have considerably changed the epidemiology of the hemoglobinopathies. Healthy carriers of these conditions are present today in many nonendemic parts of the world, and severely affected children are now born where these diseases were previously rare or unknown...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12037

    authors: Giordano PC

    更新日期:2013-10-01 00:00:00

  • Performance evaluation of the new hematology analyzer Sysmex XN-series.

    abstract:INTRODUCTION:The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. METHODS:The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the ma...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12254

    authors: Seo JY,Lee ST,Kim SH

    更新日期:2015-04-01 00:00:00

  • Performance evaluation of a new Stago® automated haemostasis analyser: The STA R Max® 2.

    abstract:INTRODUCTION:The STA R Max® 2 is a new coagulation analyser developed by Diagnostica Stago, able to perform clotting, chromogenic and immuno-turbidimetric tests. A pre-analytical module build into the cap-piercing needle performs the sample integrity verification (sample tube filling and measurement of haemolysis, icte...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13100

    authors: Cupaiolo R,Govaerts D,Blauwaert M,Cauchie P

    更新日期:2019-12-01 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • Factor XIII-A subunit Val34Leu polymorphism in fatal hemorrhagic stroke.

    abstract::Blood coagulation factor XIII (FXIII) plays a key role in the protection of fibrin clot against fibrinolysis, in the cross-linking of fibrin and its mechanical strength. The role of the FXIII-A subunit Val34Leu polymorphism with fatal primary intracerebral hemorrhages (PICH) has not been studied. We evaluated retrospe...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01465.x

    authors: Antalfi B,Pongrácz E,Csiki Z,Mezei ZA,Shemirani AH

    更新日期:2013-02-01 00:00:00

  • A rare case of Lennert's type peripheral T-cell lymphoma with t(14;19)(q11.2;q13.3).

    abstract::Although most patients with peripheral T-cell lymphoma (PTCL) show clonal rearrangement of T-cell receptor genes, few PTCLs show recurrent chromosomal abnormalities. We describe here a rare chromosomal rearrangement, t(14;19)(q11.2;q13.3), in a Lennert's lymphoma, a variant of PTCL, not otherwise specified. Sequential...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01385.x

    authors: Shin SY,Jang S,Park CJ,Chi HS,Lee KH,Huh J,Seo EJ

    更新日期:2012-06-01 00:00:00

  • Low expression of TET2 gene in pediatric acute lymphoblastic leukemia is associated with poor clinical outcome.

    abstract:INTRODUCTION:TET2, a member of the Ten-Eleven translocation gene family, catalyzes the conversion of 5-methylcytosine to 5-hydroxymethylcytosine in DNA. Low expression of TET2 has been reported as a prognostic factor for several types of malignancies in adult patients. However, there have been few data on the effect of...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13099

    authors: Zhang P,Weng WW,Chen P,Zhang Y,Ruan JF,Ba DD,Xu WQ,Tang YM

    更新日期:2019-10-01 00:00:00

  • Red blood cell morphology.

    abstract::The foundation of laboratory hematologic diagnosis is the complete blood count and review of the peripheral smear. In patients with anemia, the peripheral smear permits interpretation of diagnostically significant red blood cell (RBC) findings. These include assessment of RBC shape, size, color, inclusions, and arrang...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12082

    authors: Ford J

    更新日期:2013-06-01 00:00:00

  • Analytical comparison between two hematological analyzer systems: CAL-8000 vs. XN-9000.

    abstract:INTRODUCTION:This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL-8000 and XN-9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). METHODS:A total of 1025 peripheral blo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12597

    authors: Buoro S,Mecca T,Seghezzi M,Manenti B,Azzarà G,Dominoni P,Crippa A,Ottomano C,Lippi G

    更新日期:2017-04-01 00:00:00

  • Evaluation of small-volume tubes for venous and capillary PT (INR) samples.

    abstract:INTRODUCTION:Frequent PT (INR) testing may represent a problem for patients on warfarin treatment, and capillary or small-volume tubes may be more appropriate for such patients. A demand for small-volume tubes also comes from pediatric wards. Yet, while various small-volume tubes are available, they have not been prope...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12387

    authors: Onelöv L,Basmaji R,Svensson A,Nilsson M,Antovic JP

    更新日期:2015-10-01 00:00:00