Abstract:
:Anterior cruciate ligament (ACL) is a key fibrous connective tissue that maintains the stability of a knee joint and it is the most commonly injured ligament of the knee. A synthetic prosthesis in the form of a braided structure can be an attractive alternative to biological grafts provided that the mechanical properties can be tailored to mimic the natural ACL. In the present work, the polypropylene based structurally gradient braided prostheses have been designed and developed by understanding their tensile properties. Circular braiding process was employed to fabricate structurally gradient braided prostheses by systematically placing different types of braids in defined set of layers. An analytical model for predicting the tensile properties of structurally gradient braided prostheses has been presented by modifying and combining the existing models available in the literature. Specifically, the full set of stress-strain behaviour of structurally gradient braided prostheses has been computed based upon braid structural characteristics, constituent strand properties and braid kinematics. A triaxial braid in the outer layer of braided prostheses was found to withstand higher tensile stresses in comparison to a biaxial braid having same structural characteristics. A comparison has been made between the theoretical and experimental results of tensile properties of structurally gradient braided prostheses. The tensile properties of structurally gradient braided prostheses predicted through analytical route matched reasonably well with the experimental results.
journal_name
J Mech Behav Biomed Materauthors
Rawal A,Sibal A,Saraswat H,Quddus Khan Sdoi
10.1016/j.jmbbm.2015.09.018subject
Has Abstractpub_date
2016-02-01 00:00:00pages
305-15eissn
1751-6161issn
1878-0180pii
S1751-6161(15)00355-0journal_volume
54pub_type
杂志文章abstract::An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency depe...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.08.010
更新日期:2012-03-01 00:00:00
abstract::Age-related aortic stiffening is associated with cardiovascular diseases such as heart failure. The mechanical functions of the main structural components of the aorta, such as collagen and elastin, are determined in part by their organisation at the micrometer length scale. With age and disease both components underg...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.07.018
更新日期:2016-12-01 00:00:00
abstract::The age-related deterioration in the quality (e.g., strength and fracture resistance) and quantity (e.g., bone-mineral density) of human bone, together with increased life expectancy, is responsible for increasing incidence of bone fracture in the elderly. The present study describes ex vivo fracture experiments to qu...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.05.020
更新日期:2011-10-01 00:00:00
abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.12.010
更新日期:2015-04-01 00:00:00
abstract::Biochemical signals related to a mechanosensory mechanism by which cells sense mechanical stimuli have been gradually clarified by biological approaches such as blocking specific signaling pathways; however, mechanical signals such as deformation/strain, which is transduced into biochemical signals through this mechan...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2007.06.003
更新日期:2008-01-01 00:00:00
abstract::Bone fracture is a major health issue worldwide and consequently there have been extensive investigations into the fracture behavior of human cortical bone. However, the fracture properties of human cortical bone under fall-like loading conditions remains poorly documented. Further, most published research has been pe...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.03.015
更新日期:2017-07-01 00:00:00
abstract::Despite the great potential of Mg and its alloys as material for biodegradable implants, their low resistance to the simultaneous action of corrosion and mechanical stresses in the human body have hampered their use. Stress Corrosion Cracking has been reported as one of the most critical failure modes to overcome to a...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103724
更新日期:2020-06-01 00:00:00
abstract::Titanium alloys (Ti-6Al-4V) are promising materials as bone implants in clinical surgeries owing to their excellent performances. However, wear debris caused by the tribological behavior of the cortical bone and titanium alloy interface were found to be paramount for implant stability. The contact environment between ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.10.031
更新日期:2019-02-01 00:00:00
abstract::The use of highly sensitive soft materials has become increasingly apparent in the last few years in numerous industrial fields, due to their viscous and damping nature. Unfortunately these materials remain difficult to characterize using conventional techniques, mainly because of the very low internal forces supporte...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.06.008
更新日期:2016-10-01 00:00:00
abstract::In the present study, inflation tests with free axial extension of 15 human vena saphena magna were conducted ex vivo to obtain data suitable for multi-axial constitutive modeling at overloading conditions (pressures up to approximately 15kPa). Subsequently the data were fitted with a hyperelastic, nonlinear and aniso...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.01.023
更新日期:2015-05-01 00:00:00
abstract::The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and t...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.05.005
更新日期:2015-09-01 00:00:00
abstract::Current guidelines for abdominal aortic aneurysm (AAA) repair are primarily based on the maximum diameter. Since these methods lack robustness in decision making, new image-based methods for mechanical characterization have been proposed. Recently, time-resolved 3D ultrasound (4D US) in combination with finite element...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103571
更新日期:2020-03-01 00:00:00
abstract::In this study, Polylactic acid (PLA)/phosphate glass fibres (PGF) composites were prepared by compression moulding. Fibres produced from phosphate based glasses P2O5-CaO-MgO-Na2O (P45B0), P2O5-CaO-MgO-Na2O-B2O3 (P45B5), P2O5-CaO-MgO-Na2O-Fe2O3 (P45Fe3) and P2O5-CaO-MgO-Na2O-B2O3-Fe2O3 (P45B5Fe3) were used to reinforce...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.12.011
更新日期:2016-06-01 00:00:00
abstract::CAD/CAM restorations can be produced from several ceramic and hybrid materials. The moderate mechanical properties of PMMA based resin have hindered its use for permanent restorations. Recently, a graphene reinforced PMMA namely G-CAM has been introduced for permanent CAD/CAM restorations. Although graphene family mat...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103388
更新日期:2019-12-01 00:00:00
abstract::Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.02.006
更新日期:2013-05-01 00:00:00
abstract::The biomechanical behavior of human corneal stroma under uniaxial tension was investigated by the experimental analysis of cornea stromal lenticules taken out by corneal refractive surgery. Uniaxial tests were conducted to determine their stress-strain relationship and tensile strength. The Gasser-Ogden-Holzapfel (GOH...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.05.042
更新日期:2018-09-01 00:00:00
abstract::New processing methods for shape-memory polymers allow for tailoring material properties for numerous applications. Shape-memory nonwovens have been previously electrospun, but melt blow processing has yet to be evaluated. In order to determine the process parameters affecting shape-memory behavior, this study examine...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.05.038
更新日期:2016-09-01 00:00:00
abstract::The spatial and temporal changes of morphological and mechanical properties of living cells reflect complex functionally-associated processes. Monitoring these modifications could provide a direct information on the cellular functional state. Here we present an integrated biophysical approach to the quantification of ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103581
更新日期:2020-03-01 00:00:00
abstract::Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.04.018
更新日期:2012-09-01 00:00:00
abstract::Poly(ethylene glycol) hydrogels are currently under investigation as possible scaffold materials for bone regeneration. The main purpose of this research was to analyse the mechanical properties and thermal behaviour of novel photopolymerised poly(ethylene glycol) dimethacrylate (PEGDMA) based hydrogels. The effect of...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.04.004
更新日期:2011-10-01 00:00:00
abstract::Processing scaffolds that mimic the extracellular matrix (ECM) of natural bone in structure and chemical composition is a potential promising option for engineering physiologically functional bone tissue. In this article, we report a novel method, by combining electrospinning and mineralization, to process a series of...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2008.01.007
更新日期:2008-07-01 00:00:00
abstract::One of the most important alterations that occur in man and experimental animals during spaceflight concerns the skeletal system, and entails important bone loss and degradation of mechanical properties. In the present work we investigate ex vivo the long-term effects of weightlessness (simulated microgravity) on bone...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.01.002
更新日期:2015-04-01 00:00:00
abstract::Intervertebral disc (IVD) degeneration is a naturally, irreparable process that causes loss in IVD hydration, cellularity, and, mechanical stability. Invasive surgical attempts to ease back pain and, radiculopathy have shown to cause increased degeneration along the rest, of the spine. Due to its highly tunable mechan...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.05.014
更新日期:2017-08-01 00:00:00
abstract::We aimed to investigate the fatigue strength of Co-Cr-Mo clasps for removable partial dentures prepared by selective laser melting (SLM). The Co-Cr-Mo alloy specimens for tensile tests (dumbbell specimens) and fatigue tests (clasp specimens) were prepared by SLM with varying angles between the building and longitudina...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.02.032
更新日期:2016-06-01 00:00:00
abstract::Although great progresses in the fracture mechanisms and deformation behaviors of cortical bones have been achieved, the effective methods to predict the surface fracture path of cortical bones are still difficult. By using depth-sensing nanoindentation measurement technique, the hardness distribution map of cortical ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.104303
更新日期:2021-01-20 00:00:00
abstract:OBJECTIVES:The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device. MATERIAL AND METHODS:Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardi...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.07.003
更新日期:2018-11-01 00:00:00
abstract::It is generally accepted that calcium phosphate (CaP) is one of the most important biomaterials in implant coating applications mainly because of its excellent bioactivity. However, its relatively poor mechanical properties limits its application. This entails that a better understanding of the mechanical properties o...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2010.01.002
更新日期:2010-05-01 00:00:00
abstract::The inelastic deformability of the mineralised matrix in bones is critical to their high toughness, but the nanoscale mechanisms are incompletely understood. Antler is a tough bone type, with a nanostructure composed of mineralised collagen fibrils ∼100nm diameter. We track the fibrillar deformation of antler tissue d...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.03.020
更新日期:2013-12-01 00:00:00
abstract::Titanium and its alloys are common biomedical materials owing to their combination of mechanical properties, corrosion resistance and biocompatibility. Powder metallurgy (PM) techniques can be used to fabricate biomaterials with tailored properties because changing the processing parameters, such as the sintering temp...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.12.005
更新日期:2017-03-01 00:00:00
abstract::Metallic implant materials are biomaterials that have experienced major development over the last fifty years, yet some demands posed to them have not been addressed. For the osseointegration process and the outcome of endosseous implantation, it is crucial to reduce the stress shielding effect and achieve sufficient ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.10.008
更新日期:2019-02-01 00:00:00