Abstract:
PURPOSE:If a prostate cancer patient treated with (125)I brachytherapy dies within 12 months after the treatment, prostate removal before cremation is recommended to avoid problems related to radioactivity in the ashes, such as inhalation of airborne particulate matter by crematorium staff or nearby residents. To provide guidance for such cases, a manual prepared under the editorial supervision of several professional associations was issued in 2008 in Japan. Herein, we investigated the incidence and causes of death, and the actions taken subsequent to death, among prostate cancer patients who died within 12 months after (125)I brachytherapy over a 10-year period in Japan; and we compared the results before and after the manual was issued. METHODS AND MATERIALS:Data extracted from the Japan Radioisotope Association database for the period from September 2003 to the end of December 2013 were used. RESULTS:Of 27,976 patients who underwent (125)I brachytherapy during the specified period, 79 died within 12 months after implantation, including 3 who died in the 2011 earthquake and tsunami. The prostate and brachytherapy source were retrieved at autopsy from 69 of the 79 patients. Autopsy could not be performed on the other 10 patients, 2 of whom died in the earthquake. Autopsy and retrieval of the brachytherapy source were significantly more common after issuance of the manual than before (22/28 cases before; 47/49 cases after; p=0.021). CONCLUSION:In most cases of early death after (125)I brachytherapy in Japan, the brachytherapy source was retrieved.
journal_name
Brachytherapyjournal_title
Brachytherapyauthors
Satoh T,Dokiya T,Yamanaka H,Saito S,Ishiyama H,Itami J,Shibuya H,Nakano T,Shigematsu N,Aoki M,Egawa S,Hashimoto M,Nishimura T,Yorozu Adoi
10.1016/j.brachy.2014.08.043subject
Has Abstractpub_date
2015-03-01 00:00:00pages
136-41issue
2eissn
1538-4721issn
1873-1449pii
S1538-4721(14)00632-1journal_volume
14pub_type
杂志文章,评审相关文献
Brachytherapy文献大全abstract:PURPOSE:To investigate the safety and feasibility of intraluminal brachytherapy using 125I seed strand for locally advanced pancreatic ductal adenocarcinoma with obstructive jaundice. METHODS AND MATERIALS:From January 2010 to February 2015, 18 consecutive patients diagnosed with locally advanced, nonmetastatic, inope...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2016.05.004
更新日期:2016-01-01 00:00:00
abstract:OBJECTIVE:To evaluate the feasibility and intermediate-term results of a short course of high-dose-rate (HDR) intravaginal brachytherapy only after hysterectomy. METHODS AND MATERIALS:From December 1999 to February 2005, 50 patients with International federation of gynecology and obstetrics Stages IA-IIB endometrioid ...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2007.04.001
更新日期:2007-07-01 00:00:00
abstract:PURPOSE:To quantify the percentage doses received by salivary glands (SGDs) in head and neck interstitial brachytherapy (BT). METHODS AND MATERIALS:The study included 43 patients who underwent high-dose rate iridium-192 implant for oral cavity and oropharyngeal lesions treated with BT as a boost. BT dose varied with d...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2010.03.001
更新日期:2011-01-01 00:00:00
abstract:PURPOSE:Certain subsets of patients have an increased risk of all-cause mortality when androgen deprivation therapy (ADT) is used with definitive radiotherapy. We evaluated the relationship between pretreatment serum testosterone, age, and comorbidities on survival after prostate brachytherapy in men treated with and w...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2009.06.008
更新日期:2010-01-01 00:00:00
abstract:PURPOSE:Low-dose-rate brachytherapy using iodine-125 seeds is a highly efficacious treatment for low-risk prostate cancer. We propose a bioeffect model may be used to target an ablative dose to the tumor with a lower, therapeutic dose to low-risk regions to maintain high rates of tumor control with reduced toxicity. We...
journal_title:Brachytherapy
pub_type: 杂志文章,多中心研究
doi:10.1016/j.brachy.2013.04.008
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:The purpose of this work was to evaluate whether the delivered dose to the skin surface and at the prescription depth when using a Freiburg flap applicator is in agreement with the one predicted by the treatment planning system (TPS) using the TG-43 dose-calculation formalism. METHODS AND MATERIALS:Monte Carlo...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2011.11.005
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To evaluate the effect of hormonal manipulation on catheter dependency, the resolution of urinary symptomatology, and the need for postbrachytherapy transurethral/transincisional resection (TURP/TUIP). METHODS AND MATERIALS:Seven hundred sixteen consecutive patients (median follow-up, 29 months) underwent brac...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2003.12.001
更新日期:2004-01-01 00:00:00
abstract:OBJECTIVES:Men with higher body mass index (BMI) tend to have more fatty tissue in prostate-rectum interface, which may reduce the rectal wall dose by the inverse square law. We hypothesized that men with higher BMI will have a lower dose to the rectal wall and less rectal toxicity after permanent prostate implant. ME...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2008.12.001
更新日期:2009-04-01 00:00:00
abstract:PURPOSE:Persistent disease after definitive external beam radiation therapy for head and neck (H&N) malignancies negatively impacts survival. In this series, the effectiveness of low-dose-rate brachytherapy in the management of persistent H&N disease is explored. METHODS:All patients who received brachytherapy for per...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2008.12.007
更新日期:2009-07-01 00:00:00
abstract:PURPOSE:With accumulating evidence supporting partial-breast irradiation, we conducted a Phase I/II study to evaluate the role of a second conservative surgery and brachytherapy for patients presenting with a local recurrence/new primary in a breast who has previously undergone a lumpectomy and external radiation thera...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2007.10.006
更新日期:2008-01-01 00:00:00
abstract:PURPOSE:Accurate patient-specific dosimetry in intravascular brachytherapy (IVBT) is generally difficult due to the extremely high-dose gradient, complexity of treatment device, and patient-specific geometry (e.g., calcification, stent, curvature, movement of target). The purpose of this study is to analyze quantitativ...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2005.07.004
更新日期:2005-01-01 00:00:00
abstract:PURPOSE:To assess the toxicity and efficacy of salvage wide resection (SWR) with intraoperative electron beam radiation therapy (IOERT) or perioperative high-dose-rate brachytherapy (PHDRB) in previously unirradiated patients (PUP) vs. previously irradiated patients (PIP) with isolated local recurrence of soft tissue s...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2014.09.003
更新日期:2015-01-01 00:00:00
abstract:PURPOSE:To evaluate the efficacy and side effect profile of adjuvant vaginal vault brachytherapy alone after hysterectomy in Stage I endometrial carcinoma. METHODS AND MATERIALS:Between 23/11/1992 and 16/05/2005, a total of 173 patients with early endometrial carcinoma treated with vaginal vault brachytherapy alone po...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2008.01.001
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:The aim of this study was to estimate the incidence of complications after (90)Y microsphere radioembolization for unresectable hepatic tumors and evaluate risk factors for late complications. METHODS AND MATERIALS:A cohort of 112 consecutive patients from two institutions underwent (90)Y microsphere radioembo...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2013.05.008
更新日期:2013-11-01 00:00:00
abstract:PURPOSE:To describe the use of dual source strength implants for focal low-dose-rate brachytherapy. METHODS AND MATERIALS:An interneedle dual source strength planning strategy is described for focal low-dose-rate brachytherapy of the prostate. The implanted treatment plans were designed using peripheral (except near t...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2016.04.388
更新日期:2016-09-01 00:00:00
abstract:PURPOSE:Accelerated partial breast irradiation (APBI) continues to increase in popularity. Up to 14% of patients treated with the MammoSite (MS) report some degree of chronic pain, which may be related to chest wall toxicity. Reports from several institutions using the multicatheter (MC) technique have not shown associ...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2008.11.007
更新日期:2009-04-01 00:00:00
abstract::While brachytherapy applications are not widely used for cancer diagnoses in the upper GI tract (including the esophagus, liver, stomach, and pancreas), they have a clear role in palliation and symptom management and occasionally definitive locoregional treatment. With the increasing use of image-guided techniques, th...
journal_title:Brachytherapy
pub_type: 杂志文章,评审
doi:10.1016/j.brachy.2020.11.010
更新日期:2020-12-22 00:00:00
abstract:BACKGROUND:To determine the feasibility of combined perioperative high-dose-rate brachytherapy (PHDRB) and intermediate-dose external beam radiation therapy (EBRT) as an alternative to full-dose adjuvant EBRT in patients with unirradiated squamous cell cancer (SCC) of the oral cavity and oropharynx. METHODS AND MATERI...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2008.10.002
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:GammaTile cesium-131 (131Cs) permanent brain implant has received Food and Drug Administration (FDA) clearance as a promising treatment for certain brain tumors. Our center was the first institution in the United States after FDA clearance to offer the clinical use of GammaTile brachytherapy outside of a clinic...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2020.12.005
更新日期:2021-01-21 00:00:00
abstract:PURPOSE:To analyze the dosimetric impact and periprocedural outcomes with a bioabsorbable hydrogel rectal spacer injected during low-dose-rate (LDR) prostate brachytherapy implants. METHODS AND MATERIALS:A consecutive series of 80 patients implanted with stranded I-125 LDR brachytherapy seeds were evaluated, of which ...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2019.11.002
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:In this study, computer modeling was used to compare the relative doses with the bladder, rectum, and bowel when two different brachytherapy modalities were used to treat cervical cancer with a tandem and ovoid applicator. A standard high-dose rate (HDR) (192)Ir treatment plan was compared with a "mixed-source"...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2010.08.009
更新日期:2011-03-01 00:00:00
abstract:PURPOSE:The aim of this work was to analyze the exposure rates measured in the proximity of patients who underwent prostate low-dose-rate brachytherapy with I-125 implant. Effective doses to relatives and to population were computed to estimate the time to reach radioprotection dose constraints. METHODS AND MATERIALS:...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2020.09.003
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:The objective of this overview was to critically evaluate the effect of polyethylene glycol (PEG)-based hydrogel spacers during prostate brachytherapy with regard to dosimetric and clinical benefits, as well as procedure-related toxicity. METHODS AND MATERIALS:A systematic search in the PubMed database was per...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2019.08.009
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:TG43 does not account for a lack of scatter and tissue and applicator heterogeneities. The advanced collapsed-cone engine (ACE) algorithm available for use in the Oncentra Brachy treatment planning system (Elekta AB, Stockholm, Sweden) can model these conditions more accurately and is evaluated for esophageal a...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2020.09.006
更新日期:2020-10-15 00:00:00
abstract:PURPOSE:We sought to develop an activity nomogram for magnetic resonance (MR)-planned permanent seed prostate brachytherapy to improve quality assurance through a secondary dosimetric check. METHODS AND MATERIALS:Patients undergoing MRI-assisted radiosurgery (MARS), whereby MRI is used for preoperative planning and po...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2019.10.002
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:To analyze the effect of tungsten shields present in a Fletcher-Suit-Delclos ovoid by comparing the dose distribution computed by a treatment planning system (TPS) to the delivered dose distribution measured by radiochromic film dosimetry. METHODS AND MATERIALS:Gafchromic/EBT films were carefully wrapped aroun...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2010.08.008
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:To provide longitudinal follow-up and assess the intermediate outcomes in breast cancer patients treated with the MammoSite radiation therapy system. METHODS AND MATERIAL:Ninety-two patients with histologically proven stage 0-II breast cancer were treated with MammoSite accelerated partial breast irradiation a...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2008.07.005
更新日期:2009-01-01 00:00:00
abstract:PURPOSE:While the noninvasive breast brachytherapy (NIBB) treatment procedure, known as AccuBoost, for breast cancer patients is well established, the treatment quality can be improved by the efficiency of the workflow delivery. A formalized approach evaluated the current workflow through failure modes and effects anal...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2020.01.007
更新日期:2020-01-01 00:00:00
abstract:PURPOSE:To choose the optimal brachytherapeutic modality for uterine cervical cancer, we performed simulation analysis. METHODS AND MATERIALS:For each high-risk clinical target volume (HR CTV), we compared four modalities [classical conventional intracavitary brachytherapy (ConvICBT), Image-guided ICBT (IGICBT), intra...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2015.10.002
更新日期:2016-01-01 00:00:00
abstract:PURPOSE:To present a clinical procedure that readjusts catheters to its planned positions based on pretreatment computed tomography (CT) for patients undergoing high-dose-rate (HDR) prostate brachytherapy, and evaluate the magnitude and dosimetric impact of the adjustments. METHODS AND MATERIALS:Patients received a pr...
journal_title:Brachytherapy
pub_type: 杂志文章
doi:10.1016/j.brachy.2012.08.008
更新日期:2013-05-01 00:00:00