Histological and histomorphometric evaluation of anorganic bovine bone used for maxillary sinus floor augmentation: a six-month and five-year follow-up of one clinical case.

Abstract:

BACKGROUND:Anorganic bovine bone (ABB) is widely used in maxillary sinus floor augmentation procedures. Nevertheless, long-term human clinical cases data are very rare but still important to understand the behavior of the xenograft. The objective of this study was to analyze and to compare the histological and histomorphometric results of maxillary sinus floor augmentation using ABB at 6-month and 5-year post surgery on the same human clinical case. MATERIALS AND METHODS:Bone samples from a single patient received slight specific decalcification process before histologic and histomorphometric analyzes. RESULTS:At 6-month postoperative, the histological section showed numerous remaining ABB particles integrated inside the newly formed bone architecture. The histomorphometric results were 21.1% of newly formed bone, 30.5% of ABB xenograft, and 48.4% of marrow/connective tissue. At 5-year postoperative, small residual particles of ABB were surrounded by large areas of newly formed bone. The histomorphometric mean rates were 44.0% ± 0.1% of newly formed bone, 3.5% ± 0.3% of ABB xenograft, 6.8% ± 0.7% of bone marrow, and 45.8% ± 0.1% of connective tissue. CONCLUSION:The 6-month and 5-year postoperative histomorphometric data of this clinical case confirmed the long-term continuous ongoing resorption process of the ABB and increasing newly formed bone rate.

journal_name

Implant Dent

journal_title

Implant dentistry

authors

Ohayon L

doi

10.1097/ID.0000000000000095

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

239-44

issue

3

eissn

1056-6163

issn

1538-2982

journal_volume

23

pub_type

杂志文章
  • Evaluation of human periimplant soft tissues around nonsubmerged machined standard and platform-switched abutments.

    abstract:PURPOSE:This study evaluated the effect of the platform-switching phenomenon, the use of a smaller diameter abutment on a larger diameter implant platform. Clinical and histological outcomes of the periimplant mucosa around titanium abutments in a nonsubmerged implant were evaluated. MATERIALS AND METHODS:Ten healthy ...

    journal_title:Implant dentistry

    pub_type: 临床试验,杂志文章

    doi:10.1097/ID.0000000000000209

    authors: Collins JR,Berg RW,Rodríguez M,Rodríguez I,Coelho PG,Tovar N

    更新日期:2015-02-01 00:00:00

  • The influence of implant type, material, coating, diameter, and length on periotest values at second-stage surgery: DICRG interim report no. 4. Dental Implant Clinical Research Group.

    abstract::Many of the presently used methods of evaluating osseointegration at second-stage surgery are highly subjective. The Periotest is claimed to offer a more objective means to assess osseointegration by means of microcomputer-controlled percussion. In 1991 the Dental Implant Clinical Research Group initiated a long-term ...

    journal_title:Implant dentistry

    pub_type: 临床试验,杂志文章

    doi:10.1097/00008505-199409000-00003

    authors: Ochi S,Morris HF,Winkler S

    更新日期:1994-10-01 00:00:00

  • Mini-lateral windows for minimally invasive maxillary sinus augmentation: case series of a new technique.

    abstract:OBJECTIVES:The purpose of this article was to introduce a new technique for minimally invasive lateral window sinus augmentation, developed to maximize the amount of residual lateral wall after the procedure. MATERIALS AND METHODS:Fourteen consecutive patients requiring maxillary sinus augmentation by a lateral approa...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000119

    authors: Pariente L,Dada K,Daas M

    更新日期:2014-08-01 00:00:00

  • Osteotome-Mediated Sinus Floor Elevation With or Without a Grafting Material: A Systematic Review and Meta-analysis of Long-term Studies (≥5-Years).

    abstract:OBJECTIVE:To test the hypothesis of no difference in the long-term treatment outcome after osteotome-mediated sinus floor elevation with or without a grafting material. MATERIALS AND METHODS:A MEDLINE/PubMed, Cochrane Library, and EMBASE search in combination with a hand-search of relevant journals was conducted, incl...

    journal_title:Implant dentistry

    pub_type: 杂志文章,meta分析

    doi:10.1097/ID.0000000000000798

    authors: Aludden H,Mordenfeld A,Hallman M,Christensen AE,Starch-Jensen T

    更新日期:2018-08-01 00:00:00

  • The possible association among bone density values, resonance frequency measurements, tactile sense, and histomorphometric evaluations of dental implant osteotomy sites: a preliminary study.

    abstract:PURPOSE:The aim of the clinical preliminary trial was to determine the possible relationship among radiologic bone density, primary implant stability, and tactile sense measurements, and to clarify their possible association with histological measurements at endosseous implant osteotomy sites. MATERIALS:Eleven mandibu...

    journal_title:Implant dentistry

    pub_type: 临床试验,杂志文章

    doi:10.1097/ID.0b013e31819ecc12

    authors: Aksoy U,Eratalay K,Tözüm TF

    更新日期:2009-08-01 00:00:00

  • Evaluation of Outcomes of Dental Implants Inserted by Flapless or Flapped Procedure: A Meta-Analysis.

    abstract:PURPOSE:The purpose of this meta-analysis was to evaluate the failure risk and marginal bone loss of dental implants inserted by flapless or flapped procedure. MATERIALS AND METHODS:Studies were identified by searching PubMed, Web of Knowledge, and the Cochrane Library within 10 years, along with a hand search of the ...

    journal_title:Implant dentistry

    pub_type: 杂志文章,meta分析

    doi:10.1097/ID.0000000000000820

    authors: Zhuang J,Zhao D,Wu Y,Xu C

    更新日期:2018-10-01 00:00:00

  • Accuracy of interchangeable implant impression systems: an in vitro pilot study.

    abstract:PURPOSE:To evaluate the accuracy of impressions on changing the implant component (coping and abutment replica) between Brånemark and BIOMET 3i and between Straumann and Allfit. MATERIALS AND METHODS:Two master casts were constructed, one containing pair of Brånemark self-tap Mk II fixtures (Nobel Biocare) labeled Mas...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000231

    authors: AlFarraj Aldosari AM,AlBaker AM,AlShihri AA,AlJadeed MI,AlBwardi LA,Anil S

    更新日期:2015-06-01 00:00:00

  • Sinus Elevation Through Transcrestal Window Approach and Delayed Implant Placement in 1- to 2-mm Residual Alveolar Bone: A Case Report.

    abstract::Sinus augmentation with a lateral window technique and delayed implant placement are the traditional treatment schedules when the residual alveolar bone height in atrophic posterior maxilla is less than 5 mm. This article presents a transcrestal window approach (TWA) to replace a missing first molar in an atrophic pos...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000503

    authors: Wang M,Yan M,Xia H,Zhao Y

    更新日期:2016-12-01 00:00:00

  • Implant-retained removable prosthesis with ball attachments in partially edentulous maxilla.

    abstract::This clinical report presents a restorative option for the partially edentulous maxilla utilizing an implant-retained removable partial denture without retentive clasps. This approach required (1) fewer patient visits and laboratory procedures; (2) the use of minimal number of implants; (3) lower financial obligations...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/00008505-200110000-00012

    authors: de Carvalho WR,Barboza EP,Caúla AL

    更新日期:2001-01-01 00:00:00

  • Simultaneous Block Bone Grafting Using "L-Shaped Notch" Preparation in Mandible: Case Series and 1-Year Follow-up.

    abstract:PURPOSE:A novel autogenous block bone grafting technique with simultaneous placement of dental implants is described for several cases of horizontal ridge augmentation. METHODS:Seven patients with a mandibular horizontal ridge that was inadequate for proper implant placement were included in this study. Simultaneous i...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000311

    authors: Lee DW,Lee JW,Lim HC,Kang KL,Choi SH,Yu JA

    更新日期:2015-10-01 00:00:00

  • Direct Contact Test for Evaluating Bacterial Growth on Machined and Rough Surface Implants: An In Vitro Study.

    abstract:OBJECTIVE:To use a modified direct contact test (DCT) to evaluate the bacterial growth on 3 commercially available implants. MATERIALS AND METHODS:Streptococcus salivarius growth was tested on 1 machined surface and 2 commercial rough surface implants. Seven implants from each group were fixed to the cover of a 96-wel...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000697

    authors: Slutzkey S,Moses O,Tal H,Meirowitz A,Matalon S

    更新日期:2017-12-01 00:00:00

  • Implant support for removable partial overdentures: a case report.

    abstract::Functional stability and the preservation of remaining alveolar bone are primary, and often elusive, goals when restoring the partially edentulous arch. The incorporation of dental implants for the partial support of removable prostheses offers a practical adjunct in the fulfillment of these objectives. Planning for c...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/00008505-199901000-00009

    authors: Halterman SM,Rivers JA,Keith JD,Nelson DR

    更新日期:1999-01-01 00:00:00

  • Machine-driven versus manual insertion mode: influence on primary stability of orthodontic mini-implants.

    abstract:PURPOSE:The study aimed to explore the effect of the insertion method on maximal insertion torque as a measure of primary stability while controlling for the effect of cortical bone thickness, mini-implant length and diameter, and vertical insertion force on insertion torque. METHODS:Six types of mini-implants (Dual T...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000174

    authors: Novsak D,Trinajstic Zrinski M,Spalj S

    更新日期:2015-02-01 00:00:00

  • Alveolar Ridge Preservation Using Autologous Demineralized Tooth Matrix and Platelet-Rich Fibrin Versus Platelet-Rich Fibrin Alone: A Split-Mouth Randomized Controlled Clinical Trial.

    abstract:OBJECTIVE:To assess the potential of using autologous demineralized tooth matrix (aDTM) in combination with platelet-rich fibrin (PRF) membrane (aDTM/PRF) or PRF membrane alone (control) to preserve the ridge dimension and facilitate bone healing after tooth extraction. MATERIALS AND METHODS:Forty premolar sockets wer...

    journal_title:Implant dentistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/ID.0000000000000918

    authors: Ouyyamwongs W,Leepong N,Suttapreyasri S

    更新日期:2019-10-01 00:00:00

  • Brisk, pulsatile bleeding from the anterior mandibular incisive canal during implant surgery: a case report and use of an active hemostatic matrix to terminate acute bleeding.

    abstract::Dental implant surgery in the anterior mandible is considered a relatively routine and safe procedure with minimal morbidity. A case of brisk, pulsatile bleeding from the anterior mandibular incisive canal and its management using an active hemostatic matrix is presented. In addition, a review of the literature regard...

    journal_title:Implant dentistry

    pub_type: 杂志文章,评审

    doi:10.1097/ID.0b013e318264d70d

    authors: Lee CY,Yanagihara LC,Suzuki JB

    更新日期:2012-10-01 00:00:00

  • A new "platinum" standard for bone grafting: autogenous stem cells.

    abstract::Autogenous bone has long been considered the gold standard of all bone grafting materials. However, complications have been associated with autogenous bone-harvesting procedures. This article suggests that an alternative approach, grafting with autogenous bone marrow aspirate, may become a new platinum standard. Bone ...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/01.id.0000190419.04705.ef

    authors: Soltan M,Smiler DG,Gailani F

    更新日期:2005-12-01 00:00:00

  • A strain gauge analysis comparing external and internal implant-abutment connections.

    abstract:PURPOSE:This study compared the load transfer characteristics of a complete-arch restoration supported by 4 implants, with external and internal implant-abutment connections. Three loading positions were applied to the prostheses. MATERIALS AND METHODS:Epoxy resin models were used to simulate bone. Two types of implan...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000063

    authors: Asvanund P

    更新日期:2014-04-01 00:00:00

  • Re-osseointegration of Dental Implants After Periimplantitis Treatments: A Systematic Review.

    abstract:PURPOSE:This review considers possible surgical treatment modalities for induced periimplantitis to regain re-osseointegration as reported in the recent literature. MATERIALS AND METHODS:Electronic searches in MEDLINE/PubMed and Google Scholar databases were performed on experimental studies considering induced periim...

    journal_title:Implant dentistry

    pub_type: 杂志文章,评审

    doi:10.1097/ID.0000000000000712

    authors: Madi M,Htet M,Zakaria O,Alagl A,Kasugai S

    更新日期:2018-02-01 00:00:00

  • Rehabilitation of Postextractive Socket in the Premaxilla: A 12-Year Study on 27 Titanium Plasma Spray Resorbable Calcium Phosphate Coated Single Implants.

    abstract:OBJECTIVES:The purpose of this study was to evaluate the peri-implant bone tissue level on postextractive resorbable calcium phosphate coated single implants placed in premaxillary sites grafted with autologous bone, anorganic bovine bone (ABB), platelet-rich plasma (PRP), and keratinized epithelial connective graft ov...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000790

    authors: Perrotti V,Vozza I,Tumedei M,Pompa G,Iaculli F,Quaranta A

    更新日期:2018-08-01 00:00:00

  • Guided bone regeneration using nonexpanded polytetrafluoroethylene membranes in preparation for dental implant placements--a report of 420 cases.

    abstract::The biologic principle of guided bone regeneration has been successfully used to prevent bone loss in extraction sites. This study comprises 420 cases of alveolar ridge maintenance in preparation for dental implant placements. Nonexpanded polytetrafluoroethylene membranes were positioned over all extraction sites and ...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0b013e3181cda72c

    authors: Barboza EP,Stutz B,Ferreira VF,Carvalho W

    更新日期:2010-02-01 00:00:00

  • An evaluation of new designs in implant-abutment connections: a finite element method assessment.

    abstract:PURPOSE:This research sought first to evaluate the differences in the finite element method (FEM) analysis of 4 different implant surfaces, including internal and external connections of the same manufacturer with additional modifications. METHODS:In this study, 4 dental implants from the same manufacturer were compar...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0b013e318292625f

    authors: Covani U,Ricci M,Tonelli P,Barone A

    更新日期:2013-06-01 00:00:00

  • The abutment seating jig: a prosthodontic implant adjunct.

    abstract::Rapid, accurate seating of screw-retained implant abutment heads, where timing is controlled by internal or external hex designs, can be readily accomplished with individual, custom-cast abutment head location devices. The devices are especially useful when the abutment head-implant body complex is to be permanently c...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/00008505-199700610-00003

    authors: Judy KW

    更新日期:1997-04-01 00:00:00

  • Bone quality and the immediate loading of implants-critical aspects based on literature, research, and clinical experience.

    abstract::Immediate loading of oral implants has been extensively described in the international literature and the requirements for long-term success are evaluated. The author presents here the critical aspects of the criteria for success as well as describes the characteristics of an implant macro- and microdesign for immedia...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0b013e3181991248

    authors: Romanos GE

    更新日期:2009-06-01 00:00:00

  • Accessory mandibular foramen during dental implant placement: case report and review of literature.

    abstract::Accurate knowledge of vital anatomical structures, such as the inferior alveolar nerve, mental nerve, and mental foramen, is critical to achieve favorable results during oral surgical procedures and dental implant placement. Although uncommon, variations in mandibular foramina have been reported and if unnoticed and, ...

    journal_title:Implant dentistry

    pub_type: 杂志文章,评审

    doi:10.1097/ID.0000000000000056

    authors: Pancer B,Garaicoa-Pazmiño C,Bashutski JD

    更新日期:2014-04-01 00:00:00

  • Long-Term Retrospective Evaluation of Dental Implants Placed in Resorbed Jaws Reconstructed With Appositional Fresh-Frozen Bone Allografts.

    abstract:INTRODUCTION:The aim of this study was to evaluate the outcome of fresh-frozen bone allografts in preprosthetic surgery for implant placement purposes. MATERIALS AND METHODS:The cohort comprised 45 patients treated with fresh-frozen bone block grafts and dental implants. Clinical and radiological evaluations were perf...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000412

    authors: Maiorana C,Poli PP,Borgonovo AE,Rancitelli D,Frigo AC,Pieroni S,Santoro F

    更新日期:2016-06-01 00:00:00

  • Prevention of lingual inclination of the transport segment in vertical distraction osteogenesis in the mandible.

    abstract::Vertical distraction osteogenesis can extend not only to hard tissues but also to soft tissues. There is a tendency to cause progressive lingual inclination of the distracted segment. This study describes a method for preventing the lingual inclination of the transport segment in patients with vertical distraction ost...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0b013e3182660ecd

    authors: Shibuya Y,Takata N,Ishida S,Takeuchi J,Kobayashi M,Suzuki H,Komori T

    更新日期:2012-10-01 00:00:00

  • Histomorphometric Evaluation of Ridge Preservation With and Without Connective Tissue Graft Over Buccal Plate Using Different Types of Bone Substitute: An Animal Study.

    abstract:PURPOSE:The aim of this investigation was to assess the efficacy of using subepithelial connective tissue graft (CTG) over the buccal plate in conjunction with 2 different bone graft materials in fresh extraction sites. MATERIALS AND METHODS:Five mongrel dogs were used. Bilateral third (P3) mandibular premolars were e...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000307

    authors: Mendoza-Azpur G,Olaechea A,Pinazo M,Gomez C,Salinas E,de la Rosa M,Khouly I

    更新日期:2015-12-01 00:00:00

  • Cancellous and cortical microparticulate allograft for dental implantation: an experimental study in non-human primates.

    abstract:BACKGROUND:: A comparison of freeze-dried cancellous and cortical particulate bone allograft was made using a non-human primate model. METHODS AND MATERIALS:: Microparticulate bone allograft (90-300 μm size) made from either cortical or cancellous bone was used to pack standard bone defects in the lower extremities of...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0b013e3181ad18d6

    authors: Malinin T,Temple HT,Garg A

    更新日期:2009-10-01 00:00:00

  • Investigation of influence of different implant size and placement on stress distribution with 3-dimensional finite element analysis.

    abstract:PURPOSE:The purpose of this study was to analyze the biomechanical behavior of implants with varying number, inclination, and size, using 3-dimensional finite element (FE) analysis. MATERIAL AND METHODS:A total of 10 FE models were constructed to simulate 5 implant placement configurations: 4 and 5 axial implants, 4 i...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/ID.0000000000000158

    authors: Balkaya MC

    更新日期:2014-12-01 00:00:00

  • Effect of configuration of surgical burs on osseointegration of dental implants: a pilot study.

    abstract::Cannon burs with only one cutting surface and round burs with multiple cutting surfaces were evaluated in preparing bone sites for root form implant placement in five Macaca fascicularis monkeys. The cannon burs did not appear to produce a bone surface more conducive to osseointegration than the round burs. Bone cutti...

    journal_title:Implant dentistry

    pub_type: 杂志文章

    doi:10.1097/00008505-199404000-00009

    authors: Boyne PJ,Herford AS

    更新日期:1994-04-01 00:00:00