High-throughput on-chip leukemia diagnosis.

Abstract:

:Advances in lab-on-a-chip technologies enabled programmable, reconfigurable, and scalable manipulation of a variety of laboratory procedures. Samples, reagents, and fluids can be precisely controlled; buffer temperature, pH, and concentration control systems as well as a variety of detection systems can be integrated on a small chip. These advantages have attracted attention in various fields of clinical application including leukemia diagnosis and research. A lot of research on lab-on-a-chip based diagnosis has been reported and the field is rapidly expanding. This review describes recent developments of lab-on-a-chip technologies as solutions to challenges for high-throughput leukemia diagnosis.

journal_name

Int J Lab Hematol

authors

Park S,Moon HS,Lee DS,Kim HC,Chun H

doi

10.1111/ijlh.12054

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

480-90

issue

5

eissn

1751-5521

issn

1751-553X

journal_volume

35

pub_type

杂志文章,评审
  • Comparison of five point-of-care D-dimer assays with the standard laboratory method.

    abstract:INTRODUCTION:D-dimer (DD) assays are effective for the exclusion of deep-vein thrombosis (DVT), but point-of-care (POC) DD assays have not been fully evaluated. METHODS:We have compared five POC DD assays (Pathfast, Cardiac, Vidas, Stratus and NycoCard) with our routine DD method (Tinaquant), testing 60 samples from p...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01421.x

    authors: Antovic JP,Höög Hammarström K,Forslund G,Eintrei J,Sten-Linder M

    更新日期:2012-10-01 00:00:00

  • Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer.

    abstract:INTRODUCTION:We developed and validated reflex testing rules for the microscopic examination (ME) of body fluids (BFs) on the Sysmex XN-550 (Sysmex Corporation) instrument. METHODS:We assessed the detection limits, precision, linearity, and carryover. To develop the reflex testing rules (derivation arm), we tested 515...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12774

    authors: Cho YU,You E,Jang S,Park CJ

    更新日期:2018-06-01 00:00:00

  • Limitation of the activated partial thromboplastin time as a monitoring method of the direct thrombin inhibitor argatroban.

    abstract:BACKGROUND:Argatroban is licensed for patients with heparin-induced thrombocytopenia and monitoring is conventionally by activated partial thromboplastin time (APTT) ratio with a target of 1.5-3.0 and not exceeding 100 s. The APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Variabl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12414

    authors: Guy S,Kitchen S,Maclean R,Van Veen JJ

    更新日期:2015-12-01 00:00:00

  • Auer rod-like intracytoplasmic inclusions in multiple myeloma. A case report and review of the literature.

    abstract::Several intracytoplasmic morphological changes in the plasma cells of multiple myeloma have been described previously. However, Auer rod-like inclusions are rarely found in these types of cells. Here, we report a case of multiple myeloma with Auer rod-like, needle-shaped intracytoplasmic inclusions in plasma cells. A ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2007.01023.x

    authors: Hütter G,Nowak D,Blau IW,Thiel E

    更新日期:2009-04-01 00:00:00

  • Paroxysmal nocturnal haemoglobinuria. Experience over a 10 years period.

    abstract:INTRODUCTION:Paroxysmal nocturnal hemoglobinuria (PNH) is a hemolytic, clonal and acquired disorder of the hematopoietic stem cell with a deficiency of all glycophosphatidyl-inositol (GPI) linked proteins. The aim of this retrospective study was to analyse haematological and biochemical data from 152 patients referred ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12156

    authors: Canalejo K,Riera Cervantes N,Felippo M,Sarandría C,Aixalá M

    更新日期:2014-04-01 00:00:00

  • ICSH guidelines for the standardization of bone marrow specimens and reports.

    abstract::The bone marrow examination is an essential investigation for the diagnosis and management of many disorders of the blood and bone marrow. The aspirate and trephine biopsy specimens are complementary and when both are obtained, they provide a comprehensive evaluation of the bone marrow. The final interpretation requir...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,实务指引

    doi:10.1111/j.1751-553X.2008.01100.x

    authors: Lee SH,Erber WN,Porwit A,Tomonaga M,Peterson LC,International Council for Standardization In Hematology.

    更新日期:2008-10-01 00:00:00

  • The biological characteristics of dendritic cells derived in vitro from myelogeneous leukemia cells and healthy donor cells.

    abstract::Successful adoptive immunotherapy for leukemia depends on the generation of T cells that can specifically react with malignant cells. Dendritic cells (DCs) are important antigen-presenting cells in the development of antileukemia T-cell responses. Mononuclear cells (MNC) were isolated from peripheral blood or bone mar...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00986.x

    authors: Tong XM,Yao HP,Qian WB,Zhu LF,Fu ZH,Huang ZL,Jin J

    更新日期:2008-10-01 00:00:00

  • The mutual control of iron and erythropoiesis.

    abstract:BACKGROUND:Iron is essential for hemoglobin synthesis during terminal erythropoiesis. To supply adequate iron the carrier transferrin is required together with transferrin receptor endosomal cycle and normal mitochondrial iron utilization. Iron and iron protein deficiencies result in different types of anemia. Iron-def...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12505

    authors: Camaschella C,Pagani A,Nai A,Silvestri L

    更新日期:2016-05-01 00:00:00

  • Detection of malignant cells in serous body fluids by counting high-fluorescent cells on the Sysmex XN-2000 hematology analyzer.

    abstract:INTRODUCTION:The body fluid mode of the Sysmex XN-2000 hematology analyzer differentiates cells into mononuclear and polymorphonuclear white blood cells (WBC) and high-fluorescent cells (HFC). The aim of this study was to evaluate the performance of the HFC count for detecting malignant cells in serous body fluids. ME...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12393

    authors: Labaere D,Boeckx N,Geerts I,Moens M,Van den Driessche M

    更新日期:2015-10-01 00:00:00

  • Flow cytometry in the diagnosis of mature B-cell lymphoproliferative disorders.

    abstract::B-lineage lymphoproliferative disorders (LPD) are rather frequent diseases, associated with specific clinical or biological features but also sometimes of fortuitous discovery. Multiparameter flow cytometry plays a major role for a rapid diagnostic indication, on peripheral blood or bone marrow samples in most instanc...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13170

    authors: Debord C,Wuillème S,Eveillard M,Theisen O,Godon C,Le Bris Y,Béné MC

    更新日期:2020-06-01 00:00:00

  • Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.

    abstract::The PENTRA 60C(+) hematology analyzer provides a complete blood cell (CBC) count, including a five-part differential (5-DIFF) count and two leukocyte subpopulations, i.e. large immature cells (LIC's) and atypical lymphocytes (ALY's). We evaluated its analytical performance and assessed agreement with the ADVIA 2120, i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01011.x

    authors: Guerti K,Vertessen F,Daniëls L,Van Der Planken M

    更新日期:2009-04-01 00:00:00

  • The hematology laboratory's response to the COVID-19 pandemic: A scoping review.

    abstract::The ongoing COVID-19 pandemic has had a profound worldwide impact on the laboratory hematology community. Nevertheless, the pace of COVID-19 hematology-related research has continued to accelerate and has established the role of laboratory hematology data for many purposes including disease prognosis and outcome. The ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13381

    authors: Bell R,Zini G,d'Onofrio G,Rogers HJ,Lee YS,Frater JL

    更新日期:2020-11-12 00:00:00

  • Strategies for basic laboratory diagnostics of the hemoglobinopathies in multi-ethnic societies: interpretation of results and pitfalls.

    abstract::The consistent multi-ethnic migrations of the last decades have considerably changed the epidemiology of the hemoglobinopathies. Healthy carriers of these conditions are present today in many nonendemic parts of the world, and severely affected children are now born where these diseases were previously rare or unknown...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12037

    authors: Giordano PC

    更新日期:2013-10-01 00:00:00

  • Accuracy of serum transferrin receptor levels in the diagnosis of iron deficiency among hospital patients in a population with a high prevalence of thalassaemia trait.

    abstract::The diagnosis of iron deficiency in hospital patients can be difficult in the presence of inflammation. A raised serum transferrin receptor (sTfR) level is useful as a marker of iron deficiency as it is unaffected by inflammation. However, diseases that cause an increase in erythropoietic activity can also result in a...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00982.x

    authors: Ong KH,Tan HL,Tam LP,Hawkins RC,Kuperan P

    更新日期:2008-12-01 00:00:00

  • DOAC plasma levels measured by chromogenic anti-Xa assays and HPLC-UV in apixaban- and rivaroxaban-treated patients from the START-Register.

    abstract:INTRODUCTION:To measure direct factor Xa inhibitor (apixaban, edoxaban, rivaroxaban) concentrations, dedicated chromogenic anti-Xa assays are recommended as suitable methods to provide rapid drug quantification. Moreover, the high-performance liquid chromatography with ultraviolet detection (HPLC-UV) is reported as a r...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13159

    authors: Cini M,Legnani C,Padrini R,Cosmi B,Dellanoce C,De Rosa G,Marcucci R,Pengo V,Poli D,Testa S,Palareti G

    更新日期:2020-04-01 00:00:00

  • Diagnostic and prognostic utility of WBC counts and cell population data in patients with COVID-19.

    abstract:INTRODUCTION:Early diagnosis and identification of potential critical cases for timely treatment are crucial for COVID-19 patients. The aim of this study was to analyze the diagnostic and prognostic implications of WBC and cell population data (CPD) abnormalities related to COVID-19 at disease onset. METHODS:Baseline ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13395

    authors: Naoum FA,Ruiz ALZ,Martin FHO,Brito THG,Hassem V,Oliveira MGL

    更新日期:2020-11-15 00:00:00

  • A study of disseminated intravascular coagulation in acute leukemia reveals markedly elevated D-dimer levels are a sensitive indicator of acute promyelocytic leukemia.

    abstract:INTRODUCTION:While the presence of disseminated intravascular coagulation (DIC) has been implicated in worse clinical outcome in acute leukemia, the relationship between different subtypes of acute leukemia and the clinicopathologic features of DIC has not been systematically well studied. METHODS:In this study, we re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12636

    authors: Shahmarvand N,Oak JS,Cascio MJ,Alcasid M,Goodman E,Medeiros BC,Arber DA,Zehnder JL,Ohgami RS

    更新日期:2017-08-01 00:00:00

  • Performance evaluation of the new hematology analyzer Sysmex XN-series.

    abstract:INTRODUCTION:The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. METHODS:The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the ma...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12254

    authors: Seo JY,Lee ST,Kim SH

    更新日期:2015-04-01 00:00:00

  • Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.

    abstract:INTRODUCTION:Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ijlh.13189

    authors: Sommer JM,Sadeghi-Khomami A,Barnowski C,Wikén M,Willemze AJ

    更新日期:2020-06-01 00:00:00

  • Novel chromosomal translocations in multiple myeloma: t(13;16)(q14;q24) and t(1;15)(q10;q26).

    abstract::Multiple myeloma (MM) is a malignant plasma cell disorder that involves multiple genetic abnormalities. Chimeric transcription factors, created by gene fusion as a result of chromosomal translocations, have been implicated in the pathogenesis of the disease. Here, we report the conventional cytogenetic analysis of a M...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2006.00837.x

    authors: Akalin I,Kutlay NY,Ilhan O,Tukun A

    更新日期:2007-06-01 00:00:00

  • Technological advances in diagnostic testing for von Willebrand disease: new approaches and challenges.

    abstract::Diagnostic tests for von Willebrand disease (VWD) are important for the assessment of VWD, which is a commonly encountered bleeding disorder worldwide. Technical innovations have been applied to improve the precision and lower limit of detection of von Willebrand factor (VWF) assays, including the ristocetin cofactor ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12220

    authors: Hayward CP,Moffat KA,Graf L

    更新日期:2014-06-01 00:00:00

  • Proteasome inhibitor bortezomib overcomes P-gp-mediated multidrug resistance in resistant leukemic cell lines.

    abstract:INTRODUCTION:To study the effect of bortezomib alone or in combination with daunorubicin (DNR) on an mdr1 single-factor drug-resistant leukemia cell line K562/MDR1, a multifactor-resistant cell line K562/A02, a drug-sensitive cell line K562, and primary cells from acute myeloid leukemia patients. METHODS:The cell line...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01384.x

    authors: Zheng B,Zhou R,Gong Y,Yang X,Shan Q

    更新日期:2012-06-01 00:00:00

  • Chronic active Epstein-Barr virus infection: A heterogeneous entity requiring a high index of suspicion for diagnosis.

    abstract::Chronic active Epstein-Barr virus infection of T- and NK-cell type, systemic form, is a rare entity within the spectrum of EBV-driven T- and NK-cell lymphoproliferative disorders. Established diagnostic criteria and a characteristic clinical course help to differentiate it from other closely related EBV-positive neopl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13199

    authors: Ondrejka SL,Hsi ED

    更新日期:2020-06-01 00:00:00

  • Clinical and hematological characteristics of 88 patients with COVID-19.

    abstract:INTRODUCTION:To retrospectively analyze epidemiological, clinical and hematological characteristics of COVID-19 patients. METHODS:The demographic, symptoms, and physiological parameters of 88 patients were collected and analyzed. The performance of complete blood count (CBC) indexes for monitoring and predicting the s...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13291

    authors: Zhang H,Cao X,Kong M,Mao X,Huang L,He P,Pan S,Li J,Lu Z

    更新日期:2020-12-01 00:00:00

  • An investigation of the protective effect of alpha+-thalassaemia against severe Plasmodium falciparum amongst children in Kumasi, Ghana.

    abstract:INTRODUCTION:Several factors influence the severity of Plasmodium falciparum; here, we investigate the impact of alpha+-thalassaemia genotype on P. falciparum parasitemia and prevalence of severe anaemia amongst microcytic children from Kumasi, Ghana. METHODS:Seven hundred and thirty-two children (≤10 years) with P. f...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12122

    authors: Opoku-Okrah C,Gordge M,Kweku Nakua E,Abgenyega T,Parry M,Robertson C,Smith CL

    更新日期:2014-02-01 00:00:00

  • Paediatric reference intervals for common coagulation assays in Chinese children as performed on the STA-R coagulation analyzer.

    abstract:INTRODUCTION:In order to correctly manage the paediatric patients affected with haemostatic disorders, age-appropriate reference intervals should be used. The purpose of this study was to establish age-specific reference intervals for prothrombin time (PT), thrombin time (TT), activated partial thromboplastin time (aPT...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13098

    authors: Liu J,Dai Y,Yuan E,Li Y,Wang Q,Wang L,Su Y

    更新日期:2019-10-01 00:00:00

  • JAK2V617F mutation in patients with thrombosis: to screen or not to screen?

    abstract:INTRODUCTION:Thrombotic complications are a main concern in patients with myeloproliferative neoplasms. Recently, a gain-of-function mutation of the gene encoding the JAK2 tyrosine kinase that results in a valine-to-phenylalanine substitution at position 617 (V617F) has been described. Since the description of the JAK2...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2010.01275.x

    authors: Xavier SG,Gadelha T,Rezende SM,Zalcberg IR,Spector N

    更新日期:2011-04-01 00:00:00

  • A hierarchical approach in the diagnostic workflow of chronic myelomonocytic leukemia: Pivotal role of the "Mono-dysplasia-score" combined with flow cytometric quantification of monocyte subsets.

    abstract:INTRODUCTION:Monocytosis is a frequent trigger for blood smear review in a routine hematology laboratory whereas chronic myelomonocytic leukemia (CMML) is infrequent and arises mostly in elderly patients. In order to define the best workflow for monocytosis, we studied three diagnostic approaches: the classical morphol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13115

    authors: Zhu J,Sourdeau E,Aubert H,Clauser S,Maillon A,Capron C,Jondeau K,Ronez E,Schillinger F,Garnache-Ottou F,Cornet E,Bardet V

    更新日期:2019-12-01 00:00:00

  • Red cell membrane disorders.

    abstract::Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12657

    authors: Narla J,Mohandas N

    更新日期:2017-05-01 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00