Differentiation of atrioventricular nodal reentrant tachycardia from orthodromic reciprocating tachycardia by the resetting response to ventricular extrastimuli: comparison to response to continuous ventricular pacing.

Abstract:

BACKGROUND:The usefulness of ventricular entrainment to differentiate AV nodal reentrant tachycardia (AVNRT) from orthodromic reciprocating tachycardia (ORT) by substracting the corrected postpacing interval (cPPI) from the tachycardia cycle length (TCL) or the ventriculoatrial interval during stimulation (SA) from that during tachycardia (VA) have been widely validated. However, some tachycardias are interrupted by pacing trains but may not be so by ventricular extrastimuli resulting in resetting. OBJECTIVES:To validate prospectively the diagnostic yield of cPPI-TCL and SA-VA measurements after resetting and to determine the proportion of AVNRT and ORT that can be entrained and/or reset from the right ventricular apex (RVA). METHODS:223 consecutive patients with inducible AVNRT or ORT underwent pacing trains and single extrastimulus (also double extrastimuli if singles did not reset tachycardia) at the RVA. We calculated cPPI-TCL and SA-VA during entrainment and resetting. RESULTS:Entrainment could not be achieved in 15.2% of tachycardias because of consistent tachycardia interruption by pacing; resetting was observed in 99.5%. Values of cPPI-TCL and SA-VA > 110 milliseconds after resetting identified AVNRT as accurately as after entrainment. Values for cPPI-TCL/ SA-VA were: sensitivity: 98/100%; specificity: 96/98%; positive predictive value: 98/99%; negative predictive value: 98/100%. CONCLUSIONS:Determinations of cPPI-TCL and SA-VA after resetting with single or double RVA extrastimuli are useful maneuvers to differentiate AVNRT from ORT and can be used for nearly every inducible AVNRT or ORT, even if they are interrupted by ventricular trains.

authors

Javier García-Fernández F,Almendral J,Marta Pachón,González-Torrecilla E,Martín J,Gallardo R

doi

10.1111/jce.12079

subject

Has Abstract

pub_date

2013-05-01 00:00:00

pages

534-41

issue

5

eissn

1045-3873

issn

1540-8167

journal_volume

24

pub_type

杂志文章
  • Simulated internal defibrillation in humans using an anatomically realistic three-dimensional finite element model of the thorax.

    abstract:INTRODUCTION:Determination of the optimal electrode configuration during implantable cardioverter defibrillator (ICD) implantation remains largely an empirical process. This study investigated the feasibility of using a finite element model of the thorax to predict clinical defibrillation metrics for internal defibrill...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1997.tb00822.x

    authors: Kinst TF,Sweeney MO,Lehr JL,Eisenberg SR

    更新日期:1997-05-01 00:00:00

  • Reversal of deteriorated fractal behavior of heart rate variability by beta-blocker therapy in patients with advanced congestive heart failure.

    abstract:INTRODUCTION:The slope of the power spectrum in heart rate variability (HRV) reflects the fractal or scaling behavior in HR dynamics and recently was confirmed as an independent predictor of postmyocardial infarction survival. Whether or not the new measurement in HRV foresees the functional evolution in patients with ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.2001.00026.x

    authors: Lin LY,Lin JL,Du CC,Lai LP,Tseng YZ,Huang SK

    更新日期:2001-01-01 00:00:00

  • Dissociated pulmonary vein arrhythmia: incidence and characteristics.

    abstract:INTRODUCTION:The incidence and characteristics of dissociated arrhythmia confined to the pulmonary vein (PV) following disconnection have not been described in a large number of patients with paroxysmal atrial fibrillation. METHODS AND RESULTS:This was a prospective study of 152 patients (29 female, mean age 51 +/- 11...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1540-8167.2003.02583.x

    authors: Weerasooriya R,Jaïs P,Scavée C,Macle L,Shah DC,Arentz T,Salerno JA,Raybaud F,Choi KJ,Hocini M,Clémenty J,Haïssaguerre M

    更新日期:2003-11-01 00:00:00

  • The prevalence of early repolarization in patients with noncompaction cardiomyopathy presenting with malignant ventricular arrhythmias.

    abstract:UNLABELLED:Early Repolarization in Noncompaction Cardiomyopathy.  BACKGROUND:Early repolarization (ER) is associated with malignant ventricular arrhythmias, including ventricular fibrillation (VF) and sudden cardiac death (SCD). One possible mechanism is increased trabeculation with deep intramyocardial invagination, ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2012.02325.x

    authors: Caliskan K,Ujvari B,Bauernfeind T,Theuns DA,Van Domburg RT,Akca F,Jordaens L,Simoons ML,Szili-Torok T

    更新日期:2012-09-01 00:00:00

  • Epicardial sock mapping following monophasic and biphasic shocks of equal voltage with an endocardial lead system.

    abstract:INTRODUCTION:The reason for the increased defibrillation efficacy of biphasic shocks over monophasic shock is not definitely known. METHODS AND RESULTS:In six anesthetized pigs, we mapped the epicardium after transvenous defibrillation shocks to compare the activation patterns following successful biphasic shocks with...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1996.tb00533.x

    authors: Usui M,Callihan RL,Walker RG,Walcott GP,Rollins DL,Wolf PD,Smith WM,Ideker RE

    更新日期:1996-04-01 00:00:00

  • Modulation of procainamide's effect on conduction by cellular uncoupling in perfused rabbit hearts.

    abstract:INTRODUCTION:How cell-to-cell electrical coupling influences an antiarrhythmic agent's effect on conduction is largely unknown. To investigate this, we evaluated the effects of procainamide on myocardial conduction at decreasing degrees of cell-to-cell electrical coupling induced by graded doses of heptanol. METHODS A...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1997.tb00781.x

    authors: Spear JF,Hook BG,Josephson ME,Moore EN

    更新日期:1997-02-01 00:00:00

  • Failure of cilostazol in the prevention of ventricular fibrillation in a patient with Brugada syndrome.

    abstract::The ECG appearance in Brugada syndrome is caused by failure of the dome of the action potential to develop. Increased activity of the I(to) current in epicardial cells generates a transmural gradient with repolarization dispersion between the epicardium and the endocardium in the right ventricular wall, thus favoring ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2005.00290.x

    authors: Abud A,Bagattin D,Goyeneche R,Becker C

    更新日期:2006-02-01 00:00:00

  • Drug-induced torsades de pointes and implications for drug development.

    abstract::Torsades de pointes is a potentially lethal arrhythmia that occasionally appears as an adverse effect of pharmacotherapy. Recently developed understanding of the underlying electrophysiology allows better estimation of the drug-induced risks and explains the failures of older approaches through the surface ECG. This a...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1046/j.1540-8167.2004.03534.x

    authors: Fenichel RR,Malik M,Antzelevitch C,Sanguinetti M,Roden DM,Priori SG,Ruskin JN,Lipicky RJ,Cantilena LR,Independent Academic Task Force.

    更新日期:2004-04-01 00:00:00

  • QRS characteristics fail to reliably identify ventricular tachycardias that require epicardial ablation in ischemic heart disease.

    abstract:OBJECTIVES:We tested proposed algorithms for idiopathic and nonischemic tachycardias for their ability to identify epicardial LV-VT origins. BACKGROUND:Several ECG features have been reported to identify epicardial origins for left ventricular tachycardias (LV-VTs) in the absence of myocardial infarction. Only limited...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2011.02179.x

    authors: Martinek M,Stevenson WG,Inada K,Tokuda M,Tedrow UB

    更新日期:2012-02-01 00:00:00

  • Pathophysiology and disease progression of atrial fibrillation: importance of achieving and maintaining sinus rhythm.

    abstract::Atrial fibrillation (AF) is a progressive disease in which arrhythmia-induced remodeling facilitates evolution from paroxysmal AF to persistent and permanent AF. Changes in electrical, structural, and contractile properties of cardiac tissue that are thought to underlie AF maintenance and progression are reviewed. Als...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1540-8167.2008.01134.x

    authors: Cohen M,Naccarelli GV

    更新日期:2008-08-01 00:00:00

  • Forging ahead: Update on radiofrequency ablation technology and techniques.

    abstract::Innovations in radiofrequency (RF) ablation and nonablative techniques have led to significant advances in addressing complex arrhythmogenic substrates for a variety of cardiac arrhythmias. Anatomical challenges, deep substrate, and mid-myocardial locations may pose difficulties and decrease success rates using routin...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1111/jce.14317

    authors: Sandhu A,Nguyen DT

    更新日期:2020-01-01 00:00:00

  • Efficacy of Left Atrial Voltage-Based Catheter Ablation of Persistent Atrial Fibrillation.

    abstract:BACKGROUND:Low-voltage zones (LVZs) represent fibrotic tissue and are substrates for atrial fibrillation (AF). We hypothesized that LVZ-based substrate modification along with pulmonary vein isolation (PVI) would improve outcomes in persistent AF (PeAF) patients with LVZs, whereas PVI alone would work in patients witho...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.13019

    authors: Yamaguchi T,Tsuchiya T,Nakahara S,Fukui A,Nagamoto Y,Murotani K,Eshima K,Takahashi N

    更新日期:2016-09-01 00:00:00

  • Association between epicardial adipose tissue and embolic stroke after catheter ablation of atrial fibrillation.

    abstract:INTRODUCTION:Risk factors of embolic stroke (ES) after atrial fibrillation (AF) ablation have not been fully elucidated especially among the Asian subjects, particularly regarding epicardial adipose tissue (EAT) in cardiac imaging. We aimed to assess the incidence of ES during a long-term follow-up period after AF abla...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/jce.14154

    authors: Ahn J,Shin SY,Shim J,Kim YH,Han SJ,Choi EK,Oh S,Shin JY,Choe JC,Park JS,Lee HW,Oh JH,Choi JH,Lee HC,Cha KS,Hong TJ,Lip GYH,Lim HE

    更新日期:2019-11-01 00:00:00

  • Ablation of posteroseptal and left posterior accessory pathways guided by left atrium-coronary sinus musculature activation sequence.

    abstract:INTRODUCTION:While some posteroseptal and left posterior accessory pathways (APs) can be ablated on the tricuspid annulus or within the coronary venous system, others require a left-sided approach. "Fragmented" or double potentials are frequently recorded in the coronary sinus (CS), with a smaller, blunt component from...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1540-8167.2008.01103.x

    authors: Pap R,Traykov VB,Makai A,Bencsik G,Forster T,Sághy L

    更新日期:2008-07-01 00:00:00

  • Effects of acute volume changes on P wave characteristics: correlation with echocardiographic findings in healthy men.

    abstract:INTRODUCTION:This study was performed to determine the effect on the P wave of different hemodynamic loads to the heart. METHODS AND RESULTS:Signal-averaged P wave ECG and atrial echocardiographic measurements were obtained from eight healthy male volunteers at rest and after infusion of 1000 mL of plasma expander (Ha...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1994.tb01142.x

    authors: Vainer J,Cheriex EC,van der Steld B,Dassen WR,Smeets JL,Wellens HJ

    更新日期:1994-12-01 00:00:00

  • Long-term outcome of patients who received implantable cardioverter defibrillators for stable ventricular tachycardia.

    abstract:INTRODUCTION:Evidence is inconclusive concerning the role of implantable cardioverter defibrillators (ICDs) to treat patients with hemodynamically stable ventricular tachycardia (VT). The goal of this study was to estimate future risk of unstable ventricular arrhythmias in patients who received ICDs for stable VT. MET...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.2004.03344.x

    authors: Glikson M,Lipchenca I,Viskin S,Ballman KV,Trusty JM,Gurevitz OT,Luria DM,Eldar M,Hammill SC,Friedman PA

    更新日期:2004-06-01 00:00:00

  • Electromagnetic Contact-Force Sensing Electrophysiological Catheters: How Accurate is the Technology?

    abstract:BACKGROUND:Contact-force (CF) sensing catheters are increasingly used in clinical electrophysiological practice due to their efficacy and safety profile. As data about the accuracy of this technology are scarce, we sought to quantify accuracy based on in vitro experiments. METHODS AND RESULTS:A custom-made force senso...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.12886

    authors: Bourier F,Hessling G,Ammar-Busch S,Kottmaier M,Buiatti A,Grebmer C,Telishevska M,Semmler V,Lennerz C,Schneider C,Kolb C,Deisenhofer I,Reents T

    更新日期:2016-03-01 00:00:00

  • Catheter ablation of atrial fibrillation in patients with heart failure with reduced ejection fraction: Real world experience from six European centers.

    abstract:INTRODUCTION:Catheter ablation of atrial fibrillation (AF) has been recently shown to have an impact on the outcome of patients with heart failure and reduced LV ejection fraction (LVEF). We aimed to assess patients with reduced LVEF referred to catheter ablation of AF, and the efficacy and safety of this procedure com...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/jce.14027

    authors: Providência R,de Asmundis C,Chun J,Chierchia G,Defaye P,Anselme F,Creta A,Lambiase PD,Schmidt B,Chen S,Hunter RJ,Combes S,Honarbakhsh S,Combes N,Sousa MJ,Jebberi Z,Albenque JP,Boveda S

    更新日期:2019-08-01 00:00:00

  • Leadless multisite pacing: A feasibility study using wireless power transfer based on Langendorff rodent heart models.

    abstract:INTRODUCTION:Fifteen to thirty percent of patients with impaired cardiac function have ventricular dyssynchrony and warrant cardiac resynchronization therapy (CRT). While leadless pacemakers eliminate lead-related complications, their current form factor is limited to single-chamber pacing. In this study, we demonstrat...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.13738

    authors: Lyu H,John M,Burkland D,Greet B,Xi Y,Sampaio LC,Taylor DA,Babakhani A,Razavi M

    更新日期:2018-11-01 00:00:00

  • Compound motor action potential guided 240 seconds plus bonus freeze for safe and durable left atrial appendage isolation in patients with recurrent persistent atrial fibrillation: How to isolate the appendage with cryoballoon (the CMAP guided ICE-B proto

    abstract:INTRODUCTION:Pulmonary vein isolation (PVI) is the cornerstone ablation strategy for treatment of atrial fibrillation (AF). Ablation outside the PVs is sometimes needed particularly in persistent or longstanding AF. This study reported left atrial appendage isolation (LAAI) using cryoballoon (CB) focusing on technical ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.13818

    authors: Chen S,Schmidt B,Bordignon S,Perrotta L,Bologna F,Nagase T,Chun KRJ

    更新日期:2019-02-01 00:00:00

  • Fluctuation in autonomic tone is a major determinant of sustained atrial arrhythmias in patients with focal ectopy originating from the pulmonary veins.

    abstract:INTRODUCTION:This study was designed to analyze dynamic changes in autonomic tone preceding the onset of sustained atrial arrhythmias in patients with focal atrial fibrillation (AF) to determine why patients with frequent discharge from the arrhythmogenic foci develop sustained AF. METHODS AND RESULTS:Holter tapes fro...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.2001.00285.x

    authors: Zimmermann M,Kalusche D

    更新日期:2001-03-01 00:00:00

  • Noncontact electroanatomic mapping to characterize typical atrial flutter: participation of right atrial posterior wall in the reentrant circuit.

    abstract:BACKGROUND:Reentry utilizing cavotricuspid isthmus (CTI) is accepted as the mechanism underlying typical atrial flutter (AFLT). However, it is unclear how the right atrial (RA) posterior wall (PW) participates in AFLT circuit. We sought to investigate this by using noncontact electroanatomic mapping. METHODS:Fifteen p...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2010.01917.x

    authors: Dixit S,Lavi N,Robinson M,Riley MP,Callans DJ,Marchlinski FE,Lin D

    更新日期:2011-04-01 00:00:00

  • Adenosine can also improve the conduction between the superior vena cava and right atrium after isolation.

    abstract::A 64-year-old man with atrial tachycardia (AT) 3 years after a superior vena cava (SVC) isolation for atrial fibrillation underwent electrophysiologic testing. SVC mapping with a basket catheter revealed a more frequent activation in the SVC than in either of the atria during the AT and consequently the recovered cond...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2006.00570.x

    authors: Yamada T,Murakami Y,Plumb VJ,Kay GN

    更新日期:2006-11-01 00:00:00

  • Prevalence of modifiable risk factors and relation to stroke and death in patients with atrial fibrillation: A report from the China atrial fibrillation registry study.

    abstract:BACKGROUND:Lifestyle and risk factor management may improve outcomes in patients with atrial fibrillation (AF). We aim to evaluate the prevalence of modifiable risk factors and how these factors impact clinical outcomes in patients with AF. METHODS AND RESULTS:Data on 17 898 AF cohort patients with AF enrolled between...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/jce.14231

    authors: Jiang C,Lan DH,Du X,Geng YP,Chang SS,Zheng D,Chen JB,Yu RH,Sang CH,Long DY,Tang RB,Zhou YC,Min Y,Lu Y,Dong JZ,Lip GYH,Ma CS

    更新日期:2019-12-01 00:00:00

  • Is pulmonary vein isolation enough for persistent atrial fibrillation?

    abstract::Pulmonary vein isolation (PVI) is a well-established treatment for atrial fibrillation (AF); however, studies report suboptimal outcomes in persistent AF. Adjuvant ablation targeting the substrate outside the pulmonary veins has been proposed to improve the success rates of the procedure. In this review, we summarize ...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章,评审

    doi:10.1111/jce.14381

    authors: Terricabras M,Verma A

    更新日期:2020-08-01 00:00:00

  • Ibutilide-induced cardioversion of atrial fibrillation during pregnancy.

    abstract::We present two cases of successful cardioversion of atrial fibrillation using intravenous ibutilide during pregnancy. One patient had atrial fibrillation, complicating the Wolff-Parkinson-White syndrome and the other had a history of nonobstructive hypertrophic cardiomyopathy. No adverse maternal or fetal effects were...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.2006.00752.x

    authors: Kockova R,Kocka V,Kiernan T,Fahy GJ

    更新日期:2007-05-01 00:00:00

  • Response of pulmonary vein potentials to premature stimulation.

    abstract:INTRODUCTION:Pulmonary vein potentials reflect depolarization of muscle fascicles within the myocardial sleeves that surround the pulmonary veins. The response of pulmonary vein potentials to premature stimulation has not been described. METHODS AND RESULTS:In 31 patients with paroxysmal atrial fibrillation referred f...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 临床试验,杂志文章

    doi:10.1046/j.1540-8167.2002.00033.x

    authors: Tada H,Oral H,Ozaydin M,Greenstein R,Pelosi F Jr,Knight BP,Strickberger SA,Morady F

    更新日期:2002-01-01 00:00:00

  • Bundle branch reentry ventricular tachycardia: an investigation of the circuit with resetting.

    abstract::We describe a patient with bundle branch reentry ventricular tachycardia with 1:1 VA conduction in whom resetting was performed while obtaining simultaneous recordings from the right ventricular apex (V) and His-bundle electrogram. Both the tachycardia return cycle and the V-His interval demonstrated an increasing res...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/j.1540-8167.1996.tb00484.x

    authors: Sarter BH,Schwartzman D,Callans DJ,Gottlieb CD,Marchlinski FE

    更新日期:1996-11-01 00:00:00

  • Issues in subgroup analyses and meta-analyses of clinical trials.

    abstract::This commentary discusses two techniques commonly used to analyze clinical trials: subgroup analysis and meta-analysis. Subgroup analysis is used to evaluate the consistency of a treatment across multiple groups, usually within a clinical trial. Subgroup analysis often is used to generate or test an hypothesis about r...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1046/j.1540-8167.14.s9.1.x

    authors: Bigger JT

    更新日期:2003-09-01 00:00:00

  • When Ventricular Safety Standby Does Not Work.

    abstract::Dual chamber pacemakers have inbuilt advanced safety systems such as ventricular safety standby (crosstalk detection) to prevent ventricular oversensing resulting in inappropriate pacing inhibition. We describe a case where this safety mechanism does not reliably work and the management required to rectify the situati...

    journal_title:Journal of cardiovascular electrophysiology

    pub_type: 杂志文章

    doi:10.1111/jce.13162

    authors: Haldar SK,Steed B,Watkins S,Nair K

    更新日期:2017-05-01 00:00:00