Prediction of trabecular bone principal structural orientation using quantitative ultrasound scanning.

Abstract:

:Bone has the ability to adapt its structure in response to the mechanical environment as defined as Wolff's Law. The alignment of trabecular structure is intended to adapt to the particular mechanical milieu applied to it. Due to the absence of normal mechanical loading, it will be extremely important to assess the anisotropic deterioration of bone during the extreme conditions, i.e., long term space mission and disease orientated disuse, to predict risk of fractures. The propagation of ultrasound wave in trabecular bone is substantially influenced by the anisotropy of the trabecular structure. Previous studies have shown that both ultrasound velocity and amplitude is dependent on the incident angle of the ultrasound signal into the bone sample. In this work, seven bovine trabecular bone balls were used for rotational ultrasound measurement around three anatomical axes to elucidate the ability of ultrasound to identify trabecular orientation. Both ultrasound attenuation (ATT) and fast wave velocity (UV) were used to calculate the principal orientation of the trabecular bone. By comparing to the mean intercept length (MIL) tensor obtained from μCT, the angle difference of the prediction by UV was 4.45°, while it resulted in 11.67° angle difference between direction predicted by μCT and the prediction by ATT. This result demonstrates the ability of ultrasound as a non-invasive measurement tool for the principal structural orientation of the trabecular bone.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lin L,Cheng J,Lin W,Qin YX

doi

10.1016/j.jbiomech.2012.04.022

subject

Has Abstract

pub_date

2012-06-26 00:00:00

pages

1790-5

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00249-7

journal_volume

45

pub_type

杂志文章
  • Influence of lateral destabilization on compensatory stepping responses.

    abstract::Previous studies of compensatory stepping, in response to postural perturbation, have focussed on forward or backward stepping; however, the ability to step in other directions is of equal functional importance, since the perturbations encountered in daily life may often include a lateral component. The primary object...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00053-4

    authors: Maki BE,McIlroy WE,Perry SD

    更新日期:1996-03-01 00:00:00

  • Age-related differences in the maintenance of frontal plane dynamic stability while stepping to targets.

    abstract::Older adults may be vulnerable to frontal plane dynamic instability, which is of clinical significance. The purpose of the current investigation was to examine the age-related differences in frontal plane dynamic stability by quantifying the margin of stability and hip abductor moment generation of subjects performing...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.003

    authors: Hurt CP,Grabiner MD

    更新日期:2015-02-26 00:00:00

  • Volumetric locking free 3D finite element for modelling of anisotropic visco-hyperelastic behaviour of anterior cruciate ligament.

    abstract::Solids such as polymers, soft biological tissues display visco-hyperelastic, isochoric and finite deformation behaviour. The incompressibility constraint imposed severe restriction on the displacement field results in volumetric locking. Many techniques have been developed to address the issue such as reduced integrat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.016

    authors: Bijalwan A,Patel BP,Marieswaran M,Kalyanasundaram D

    更新日期:2018-05-17 00:00:00

  • Mechanical stretch inhibits mesenchymal stem cell adipogenic differentiation through TGFβ1/Smad2 signaling.

    abstract::Mesenchymal stem cells (MSCs) are the common precursors of several functionally disparate cell lineages. A plethora of chemical and physical stimuli contribute to lineage decisions and guidance, including mechanical stretch concomitant with physical movement. Here, we examined how stretch regulates MSC differentiation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.013

    authors: Li R,Liang L,Dou Y,Huang Z,Mo H,Wang Y,Yu B

    更新日期:2015-10-15 00:00:00

  • Passive muscle mechanical properties of the medial gastrocnemius in young adults with spastic cerebral palsy.

    abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.008

    authors: Barber L,Barrett R,Lichtwark G

    更新日期:2011-09-02 00:00:00

  • Towards clinical application of biomechanical tools for the prediction of fracture risk in metastatic bone disease.

    abstract::Current clinical practice lacks an accurate predictor for the pathological fracture risk in metastatic bone disease, but biomechanical tools are under development to improve these predictions. In this paper we explain the limitations of currently used clinical guidelines and provide an overview of more objective and q...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.017

    authors: Derikx LC,Verdonschot N,Tanck E

    更新日期:2015-03-18 00:00:00

  • Measurement of whole-body vibration by double-pulsed holography.

    abstract::A technique for registering vibration and deformation patterns has been adapted for the measurement of whole-body vibration in humans. Double-exposure holographic interferometry produces three dimensional pictures of the body, allowing exact measurement of the subject's movement between the two pulses. In this study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90036-8

    authors: Wangenheim M,Holzmann P,Svensson LB

    更新日期:1984-01-01 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • Experimental evaluation of local wave speed in the presence of reflected waves.

    abstract::Wave speed (also called pulse wave velocity) is the speed by which disturbance travels along the medium and it depends on the mechanical and geometrical properties of the vessel and on the density of the blood. Wave speed is a parameter of clinical relevance because it is an indicator of arterial stiffness and cardiov...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.007

    authors: Borlotti A,Li Y,Parker KH,Khir AW

    更新日期:2014-01-03 00:00:00

  • How muscle architecture and moment arms affect wrist flexion-extension moments.

    abstract::The purpose of this investigation was to determine how the moment arms and architecture of the wrist muscles influence their isometric moment-generating characteristics. A three-dimensional computer graphic model was developed that estimates the moment arms, maximum isometric forces, and maximum isometric flexion-exte...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00015-8

    authors: Gonzalez RV,Buchanan TS,Delp SL

    更新日期:1997-07-01 00:00:00

  • β-Tricalcium phosphate for bone replacement: stability and integration in sheep.

    abstract::Implants of microporous β-tricalcium phosphate (β-TCP) were developed for primarily stable supply of bone defects. A consistent stability over the healing period should be retained in sheep. β-TCP cylindrical shaped implants, with 7 mm diameter, 25 mm length, medium pore diameter 5 μm and 40% porosity were developed. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.040

    authors: Mayr HO,Suedkamp NP,Hammer T,Hein W,Hube R,Roth PV,Bernstein A

    更新日期:2015-04-13 00:00:00

  • Acquisition of full-field strain distributions on ovine fracture callus cross-sections with electronic speckle pattern interferometry.

    abstract::This study evaluated the feasibility of assessing continuous strain distributions on fracture callus cross-sections with an electronic speckle pattern interferometry (ESPI) system. Mid-sagittal callus cross-sections were harvested from ovine tibiae. One low stiffness (LS) specimen and one high stiffness (HS) specimen ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.024

    authors: Bottlang M,Mohr M,Simon U,Claes L

    更新日期:2008-01-01 00:00:00

  • An inverse finite-element model of heel-pad indentation.

    abstract::A numerical-experimental approach has been developed to characterize heel-pad deformation at the material level. Left and right heels of 20 diabetic subjects and 20 nondiabetic subjects matched for age, gender and body mass index were indented using force-controlled ultrasound. Initial tissue thickness and deformation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.03.007

    authors: Erdemir A,Viveiros ML,Ulbrecht JS,Cavanagh PR

    更新日期:2006-01-01 00:00:00

  • Loading and deformation of the cat posterior knee joint capsule in axial and extension rotations.

    abstract::Deformation and loading of the knee posterior joint capsule were studied in the cat, in extension rotations and in axial external (ER) and internal (IR) rotations at full extension. Loads were measured in the ligament along the upper edge of the capsule, using mechanically sensitive neurons that were calibrated as loa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90352-f

    authors: Grigg P,Hoffman AH

    更新日期:1993-11-01 00:00:00

  • Adversarial autoencoder for visualization and classification of human activity: Application to a low-cost commercial force plate.

    abstract::The ability to visualize and interpret high dimensional time-series data will be critical as wearable and other sensors are adopted in rehabilitation protocols. This study proposes a latent space representation of high dimensional time-series data for data visualization. For that purpose, a deep learning model called ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109684

    authors: Hernandez V,Kulić D,Venture G

    更新日期:2020-04-16 00:00:00

  • Aerodynamic study of different cyclist positions: CFD analysis and full-scale wind-tunnel tests.

    abstract::Three different cyclist positions were evaluated with Computational Fluid Dynamics (CFD) and wind-tunnel experiments were used to provide reliable data to evaluate the accuracy of the CFD simulations. Specific features of this study are: (1) both steady Reynolds-averaged Navier-Stokes (RANS) and unsteady flow modellin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.025

    authors: Defraeye T,Blocken B,Koninckx E,Hespel P,Carmeliet J

    更新日期:2010-05-07 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • Comparison of biomechanical failure criteria for abdominal aortic aneurysm.

    abstract::Medical doctors consider a surgery option for the expanding abdominal aortic aneurysm (AAA) when its maximum diameter reaches 5.5cm. This simple geometrical criterion may possibly underestimate the risks of rupture of small aneurysms as well as overestimate the risks of rupture of large aneurysms. Biomechanical criter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.024

    authors: Volokh KY

    更新日期:2010-07-20 00:00:00

  • Non-Newtonian blood flow in human right coronary arteries: transient simulations.

    abstract::This study looks at pulsatile blood flow through four different right coronary arteries, which have been reconstructed from biplane angiograms. A non-Newtonian blood model (the Generalised Power Law), as well as the usual Newtonian model of blood viscosity, is used to study the wall shear stress in each of these arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.034

    authors: Johnston BM,Johnston PR,Corney S,Kilpatrick D

    更新日期:2006-01-01 00:00:00

  • Stress deprivation from the patellar tendon induces apoptosis of fibroblasts in vivo with activation of mitogen-activated protein kinases.

    abstract::The effect of stress deprivation on the tendon tissue has been an important focus in the field of biomechanics. However, less is known about the in vivo effect of stress deprivation on fibroblast apoptosis as of yet. This study was conducted to test a hypothesis that complete stress deprivation of the patellar tendon ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.027

    authors: Kawabata H,Katsura T,Kondo E,Kitamura N,Miyatake S,Tanabe Y,Setoguchi T,Komiya S,Yasuda K

    更新日期:2009-11-13 00:00:00

  • Impact-induced osteochondral fracture in the tibial plateau.

    abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.033

    authors: Thambyah A,Shim VP,Chong LM,Lee VS

    更新日期:2008-01-01 00:00:00

  • Experimentally verified mathematical approach for the prediction of force developed by motor units at variable frequency stimulation patterns.

    abstract::During normal daily activity, muscle motor units (MUs) develop unfused tetanic contractions evoked by trains of motoneuronal firings at variable interpulse intervals (IPIs). The mechanical responses of a MU to successive impulses are not identical. The aim of this study was to develop a mathematical approach for the p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.034

    authors: Raikova R,Rusev R,Drzymała-Celichowska H,Krutki P,Aladjov H,Celichowski J

    更新日期:2010-05-28 00:00:00

  • On the anisotropy of the canine diaphragmatic central tendon.

    abstract::We studied the mechanical and anatomical anisotropy of the canine diaphragmatic central tendon (CT). Dumb-bell-shaped strips with effective dimensions of 10 x 2 mm (length x width) were cut from different regions of the canine diaphragmatic CT in two different orientations relative to the direction of neighboring musc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90289-y

    authors: Chuong CJ,Sacks MS,Johnson RL Jr,Reynolds R

    更新日期:1991-01-01 00:00:00

  • A multipurpose muscle ergometer.

    abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90312-5

    authors: Woittiez RD,Brand C,de Haan A,Hollander AP,Huijing PA,van der Tak R,Rijnsburger WH

    更新日期:1987-01-01 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • Spatial phenotyping of the endocardial endothelium as a function of intracardiac hemodynamic shear stress.

    abstract::Despite substantial evidence for the central role of hemodynamic shear stress in the functional integrity of vascular endothelial cells, hemodynamic and molecular regulation of the endocardial endothelium lining the heart chambers remains understudied. We propose that regional differences in intracardiac hemodynamics ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.018

    authors: McCormick ME,Manduchi E,Witschey WRT,Gorman RC,Gorman JH 3rd,Jiang YZ,Stoeckert CJ Jr,Barker AJ,Yoon S,Markl M,Davies PF

    更新日期:2017-01-04 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Effect of non-Newtonian fluid properties on bovine sperm motility.

    abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.005

    authors: Hyakutake T,Suzuki H,Yamamoto S

    更新日期:2015-09-18 00:00:00

  • Hemodynamic effects of pulsatile unloading of left ventricular assist devices (LVAD) on intraventricular flow and ventricular stress.

    abstract::The role of pulsatile unloading in hemodynamic changes in intraventricular flow and ventricular wall stress remains unknown. In this study, a finite element model of the left ventricle (LV) is proposed to calculate the mechanical response. The constitutive model of the LV is composed of a quasi-incompressible transver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109425

    authors: Gu K,Guan Z,Chang Y,Gao B,Ling Y,Song Z,Wan F

    更新日期:2020-04-16 00:00:00

  • Stiffness versus prestress relationship at subcellular length scale.

    abstract::Local intracellular variations of cell mechanical properties, which are essential for vital cellular functions, have not been well characterized and are poorly understood. Here, we used results from our previous biomechanical imaging study to obtain relationships between intracellular shear modulus and prestress. We f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.004

    authors: Canović EP,Seidl DT,Barbone PE,Smith ML,Stamenović D

    更新日期:2014-09-22 00:00:00