In vitro measurements of precision of fit of implant-supported frameworks. A comparison between "virtual" and "physical" assessments of fit using two different techniques of measurements.

Abstract:

BACKGROUND:Comparisons between different techniques measuring fit of implant-supported frameworks are few. PURPOSE:The purpose of this study was to compare data on precision of fit from two highly accurate measuring techniques and, also, to compare results using software programs for fit assessments considering both a "virtual" as well as a "physical" (i.e., more clinical) situation. MATERIALS AND METHODS:Five computer numerical control-milled titanium frameworks (Procera Implant Bridge, Nobel Biocare AB, Göteborg, Sweden) were fabricated from individual model/pattern measurements, simulating a clinical situation. Measurements of fit between frameworks and models were performed by means of a coordinate measuring machine (CMM; Zeiss Prismo Vast, Carl Zeiss Industrielle Messtechnik GmbH, Oberkochen, Germany) linked to a computer and an optical, high-resolution, three-dimensional scanner (Atos 4M SO, GOM International AG, Widen, Switzerland). Collected data on distortions between frameworks and models were analyzed and compared between the two measurement techniques. A comparison between "virtual" and "physical" fit assessments was also performed, based on data from the three-dimensional scanner. RESULTS:When using "virtual" fit assessment programs, overall mean three-dimensional distortion between implant and framework center points in absolute figures was 37 (SD 22) and 14 µm (SD 8) for the CMM and three-dimensional scanning measurements, respectively. Corresponding mean three-dimensional distortion when using a "physical" fit assessment program in the scanner was 43 µm (SD 24) (p < 0.001). Mean horizontal (x-axis) measurements of the distance between the two terminal implants of the models and the frameworks were 33.772 and 33.834 mm for the CMM technique. Corresponding measurements for the three-dimensional scanner was 33.798 and 33.806 mm, respectively. Horizontal distances from the three-dimensional scanner were, for most measurements, greater than for the CMM measurements. CONCLUSION:Measurements of fit between frameworks and models may vary depending on what technique is used and how fit assessments regarding "virtual" or "physical" fit is approached.

authors

Jemt T,Hjalmarsson L

doi

10.1111/j.1708-8208.2011.00416.x

subject

Has Abstract

pub_date

2012-05-01 00:00:00

pages

e175-82

eissn

1523-0899

issn

1708-8208

journal_volume

14 Suppl 1

pub_type

杂志文章
  • Modulating macrophage polarization on titanium implant surface by poly(dopamine)-assisted immobilization of IL4.

    abstract:BACKGROUND:In the past few decades, very little research has been carried out to modify implant surfaces to improve osteointegration through the regulation of immune cells. PURPOSE:The aim of this study is to investigate whether the poly(dopamine) (pDA)-assisted immobilization of IL4 on titanium surfaces could modulat...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12819

    authors: Wang Y,Qi H,Miron RJ,Zhang Y

    更新日期:2019-10-01 00:00:00

  • Immediate/early loading of dental implants: a report from the Sociedad Española de Implantes World Congress consensus meeting in Barcelona, Spain, 2002.

    abstract:BACKGROUND:Immediate/early loading protocols are becoming frequently used in implant dentistry, but the prerequisites for achieving good results and the limitations of such protocols are not fully known. Moreover, the terminology used in immediate/early loading is still confusing. PURPOSE:The purpose of this article i...

    journal_title:Clinical implant dentistry and related research

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1111/j.1708-8208.2003.tb00183.x

    authors: Aparicio C,Rangert B,Sennerby L

    更新日期:2003-01-01 00:00:00

  • Autogenous bone grafting for treatment of osseous defect after impacted mandibular third molar extraction: A randomized controlled trial.

    abstract:BACKGROUND:Extraction of impacted mandibular third molar (M3) has been cited as causing osseous defect at the distal aspect of the adjacent second molar (M2). PURPOSE:This randomized controlled trial was aimed to evaluate the effect of autogenous bone grafting in situ for regeneration of periodontal osseous defect dis...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12466

    authors: Ge J,Yang C,Zheng J,Hu Y

    更新日期:2017-06-01 00:00:00

  • Immediate implant placement combined with maxillary sinus floor elevation utilizing the transalveolar approach and nonsubmerged healing for failing teeth in the maxillary molar area: A randomized controlled trial clinical study with one-year follow-up.

    abstract:BACKGROUND:In previous studies, immediate implant placement in molar sites has been widely applied. PURPOSE:To study the clinical effect and feasibility of immediate implant placement combined with maxillary sinus floor elevation utilizing the transalveolar approach and nonsubmerged healing for failing teeth in the ma...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12783

    authors: Liu H,Liu R,Wang M,Yang J

    更新日期:2019-06-01 00:00:00

  • Rational design and in vitro characterization of novel dental implant and abutment surfaces for balancing clinical and biological needs.

    abstract:BACKGROUND:Long-term success and patient satisfaction of dental implant systems can only be achieved by fulfilling clinical as well as biological needs related to maintenance, aesthetics, soft tissue sealing, and osseointegration, among others. Surface properties largely contribute to the biological and clinical perfor...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12736

    authors: Milleret V,Lienemann PS,Gasser A,Bauer S,Ehrbar M,Wennerberg A

    更新日期:2019-03-01 00:00:00

  • Immediate occlusal loading of Brånemark TiUnite implants placed predominantly in soft bone: 1-year results of a prospective clinical study.

    abstract:BACKGROUND:The original Brånemark protocol for dental implant treatment was based on submerged healing prior to loading. However, immediate loading has been reported possible with high success rates for various indications, provided that good bone quality and quantity are present. In many of these studies, machined-sur...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1708-8208.2003.tb00015.x

    authors: Glauser R,Lundgren AK,Gottlow J,Sennerby L,Portmann M,Ruhstaller P,Hämmerle CH

    更新日期:2003-01-01 00:00:00

  • Peri-implant parameters and C-reactive protein levels among patients with different obesity levels.

    abstract:BACKGROUND:It is hypothesized that peri-implant conditions are worse with increasing severity of obesity, because systemic low-grade inflammatory marker (C-reactive protein [CRP]) is higher in severe form of obese individuals. PURPOSE:The aim of the cross-sectional retrospective study was to compare clinical and radio...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12556

    authors: Vohra F,Alkhudhairy F,Al-Kheraif AA,Akram Z,Javed F

    更新日期:2018-04-01 00:00:00

  • RFA values of implants placed in sinus grafted and nongrafted sites after 6 and 12 months.

    abstract:BACKGROUND:Maxillary sinus floor elevation surgery is widely used as a preimplantology method to permit implant insertion. Nevertheless, very few data are available about long-term stability of dental implants inserted in grafted sites. PURPOSE:The aims of the present study were to evaluate the evolution of resonance ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00113.x

    authors: Degidi M,Daprile G,Piattelli A

    更新日期:2009-09-01 00:00:00

  • Immediate fixed rehabilitation of the edentulous maxilla: a prospective clinical and radiological study after 3 years of loading.

    abstract:PURPOSE:The aim of this study was to prospectively evaluate the clinical and radiographic outcomes of immediate full-arch fixed maxillary prosthesis supported by two axial and four tilted implants after 3 years of loading. MATERIALS AND METHODS:Thirty-two patients with atrophic maxilla were consecutively enrolled and ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2012.00482.x

    authors: Agliardi EL,Pozzi A,Stappert CF,Benzi R,Romeo D,Gherlone E

    更新日期:2014-04-01 00:00:00

  • Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.

    abstract:BACKGROUND:Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES:The aims of this study were...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2008.00095.x

    authors: Turkyilmaz I,Sennerby L,Yilmaz B,Bilecenoglu B,Ozbek EN

    更新日期:2009-03-01 00:00:00

  • Stability and Marginal Bone Level Changes of SLActive Titanium-Zirconium Implants Placed with Flapless Surgery: A Prospective Pilot Study.

    abstract:BACKGROUND:Immediately-loaded, narrow-diameter implants can be a less invasive alternative for the implant-supported fixed rehabilitation of narrow, posterior crests. PURPOSE:To determine the stability and marginal bone level (MBL) changes of narrow-diameter, titanium-zirconium (TiZr) implants placed with flapless sur...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12392

    authors: Altinci P,Can G,Gunes O,Ozturk C,Eren H

    更新日期:2016-12-01 00:00:00

  • A 3-year retrospective study of Cresco frameworks: preload and complications.

    abstract:PURPOSE:The aim of this retrospective clinical study was to evaluate the clinical outcome of fixed implant-supported complete prostheses on Astra or Brånemark implants when using either conventional cast frameworks or frameworks produced according to the Cresco Ti Precision method (Cresco Ti Systems Sàrl., Lausanne, Sw...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00064.x

    authors: Hjalmarsson L,Smedberg JI

    更新日期:2005-01-01 00:00:00

  • Clinical and radiographic peri-implant outcomes of short dental implants placed in posterior jaws of patients with treated generalized aggressive periodontitis: A 3-year follow-up study.

    abstract:BACKGROUND:Studies assessing clinical and radiographic peri-implant parameters around short dental implants (SDIs) in treated generalized aggressive periodontitis (GAgP) patients are scant. OBJECTIVES:This 3-year follow-up study aimed to compare the clinical peri-implant and radiographic bone status around SDIs placed...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12761

    authors: Akram Z,Vohra F,Sheikh SA,Albaijan R,Bukhari IA,Hussain M

    更新日期:2019-08-01 00:00:00

  • Biomarkers for Bisphosphonate-Related Osteonecrosis of the Jaw.

    abstract:PURPOSE:The aim of this study was to investigate a possible biomarker for bisphosphonate-related osteonecrosis of the jaw (BRONJ) in an animal model. MATERIALS AND METHODS:Forty-eight Sprague-Dawley rats were randomly divided into the bisphosphonate group (n = 36), who were injected once a week with zoledronic acid, a...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12297

    authors: Kim JW,Cha IH,Kim SJ,Kim MR

    更新日期:2016-04-01 00:00:00

  • Temporary implants for patients with low bone density of the upper maxilla: an alternative rehabilitation strategy.

    abstract:BACKGROUND:The use of removable provisional prosthesis after implant placement is undesirable for many patients. In addition, removable prostheses place unfavorable pressure over implants during the healing period. PURPOSE:The use of temporary implants enable greater stability and functionality of the prostheses. MAT...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2009.00225.x

    authors: de Aguiar RC,Zabolotsky B,de Souza DC,Ferreira CF,Cardoso AC

    更新日期:2012-03-01 00:00:00

  • Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

    abstract:PURPOSE:The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. MATERIALS AND METHODS:Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12178

    authors: Vivan Cardoso M,Vandamme K,Chaudhari A,De Rycker J,Van Meerbeek B,Naert I,Duyck J

    更新日期:2015-08-01 00:00:00

  • Implant failures and age at the time of surgery: A retrospective study on implant treatments in 4585 edentulous jaws.

    abstract:BACKGROUND:There is limited knowledge on the relationship between implant failures and patient age at implant surgery. PURPOSE:To further analyze and report long-term data on previously presented significant associations between implant failures and age at surgery in patients receiving treatment in the edentulous jaw....

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12753

    authors: Jemt T

    更新日期:2019-08-01 00:00:00

  • Clinical and immunohistochemical performance of lyophilized platelet-rich fibrin (Ly-PRF) on tissue regeneration.

    abstract:BACKGROUND:Platelet-rich fibrin (PRF) has been widely used in oral implantology and other fields, but benefits of the fresh PRF (FPRF (fresh platelet-rich fibrin)) were consequently limited because of its short-term application. Thus, a protocol for the combination of PRF and lyophilization comes up in the present stud...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12473

    authors: Zhang J,Qi X,Luo X,Li D,Wang H,Li T

    更新日期:2017-06-01 00:00:00

  • One-year results of a prospective multicenter study on Brånemark System implants with a TiUnite surface.

    abstract:BACKGROUND:A moderately rough surface implant (TiUnite, Nobel Biocare AB, Göteborg, Sweden) was introduced in 2000. Laboratory studies and some clinical studies have demonstrated excellent bone response in the early healing phase. PURPOSE:The aim of this prospective multicenter study was to follow a large number of co...

    journal_title:Clinical implant dentistry and related research

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/j.1708-8208.2005.tb00077.x

    authors: Friberg B,Dahlin C,Widmark G,Ostman PO,Billström C

    更新日期:2005-01-01 00:00:00

  • Buccal bone thickness at dental implants in the maxillary anterior region with large bony defects at time of immediate implant placement: A 1-year cohort study.

    abstract:BACKGROUND:There is lack of studies regarding preservation and possible changes in BBT at dental implants. PURPOSE:To assess, on cone beam computer tomograms, the presence of bone at the time of tooth extraction in the maxillary esthetic region and the mean buccal bone thickness 1 month and 1 year after final restorat...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12701

    authors: Meijer HJA,Slagter KW,Vissink A,Raghoebar GM

    更新日期:2019-02-01 00:00:00

  • Treatment of Peri-Implant Defects in the Rabbit's Tibia with Adipose or Bone Marrow-Derived Mesenchymal Stems Cells.

    abstract:BACKGROUND:Mesenchymal stem cell (MSC) treatment in conjunction with bone graft materials or space filler can be an alternative to autogenous bone grafts in the treatment of peri-implant bone defects. PURPOSE:To evaluate the success of bone regeneration capacity of adipose-derived and bone marrow-derived MSCs for the ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12378

    authors: Erdogan Ö,Supachawaroj N,Soontornvipart K,Kheolamai P

    更新日期:2016-10-01 00:00:00

  • Comparison of fit accuracy between Procera® custom abutments and three implant systems.

    abstract:BACKGROUND:Although increase of misfit has been reported when associating implant and abutment from different manufacturers, Procera custom abutment has been universally used in clinical practice. PURPOSE:The purpose of this investigation was to compare the vertical gap of zirconia Procera® abutment associated with im...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2010.00323.x

    authors: de Morais Alves da Cunha T,de Araújo RP,da Rocha PV,Amoedo RM

    更新日期:2012-12-01 00:00:00

  • Implant-Supported Single Crowns Replacing Congenitally Missing Maxillary Lateral Incisors: A 5-Year Follow-Up.

    abstract:BACKGROUND:Knowledge of the long-term survival of single implants in cases of congenitally missing lateral incisors in the maxilla is limited. PURPOSE:This retrospective study aimed to evaluate the 5-year survival of implants and implant-supported crowns (ISCs) and to assess the functional and aesthetic outcomes from ...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12233

    authors: Branzén M,Eliasson A,Arnrup K,Bazargani F

    更新日期:2015-12-01 00:00:00

  • Evaluation of L-PRF combined with deproteinized bovine bone mineral for early implant placement after maxillary sinus augmentation: A randomized clinical trial.

    abstract:PURPOSE:To investigate the effectiveness of adding leukocyte and platelet-rich fibrin (L-PRF) to deproteinized bovine bone mineral (DBBM) for early implant placement after maxillary sinus augmentation. MATERIALS AND METHODS:Twelve patients requiring two-stage bilateral maxillary sinus augmentation were enrolled to the...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/cid.12713

    authors: Pichotano EC,de Molon RS,de Souza RV,Austin RS,Marcantonio E,Zandim-Barcelos DL

    更新日期:2019-04-01 00:00:00

  • Immediate implant in the posterior region combined with alveolar ridge preservation and sealing socket abutment: A retrospective 3D radiographic analysis.

    abstract:BACKGROUND:Customized sealing socket abutment (SSA) has been claimed to optimize the peri-implant hard and soft tissues in type 1 implant placement. However, the evidence to claim the benefits of this technique over the use a conventional healing abutment remains weak. PURPOSE:The aim of this retrospective study was t...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12974

    authors: Alexopoulou M,Lambert F,Knafo B,Popelut A,Vandenberghe B,Finelle G

    更新日期:2021-01-13 00:00:00

  • Nonsubmerged implants in the treatment of the edentulous lower jaw: a 5-year prospective longitudinal study of ITI hollow screws.

    abstract:BACKGROUND:Although most implant systems have been designed for a two-stage surgical technique, a one-stage surgical technique has always been advocated for the ITI Dental Implant System (Straumann AG, Waldenburg, Switzerland). A new generation of ITI implants was presented in 1988 and included a hollow cylinder, a hol...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2001.tb00125.x

    authors: Hellem S,Karlsson U,Almfeldt I,Brunell G,Hamp SE,Astrand P

    更新日期:2001-01-01 00:00:00

  • Bone formation at titanium implants prepared with iso- and anisotropic surfaces of similar roughness: an in vivo study.

    abstract:BACKGROUND:Implant surface topography influences the bone response after implantation. However, the importance of surface orientation is not known. PURPOSE:The aim of this study was to investigate the bone tissue response and the stability of titanium implants prepared with isotropic and anisotropic surfaces of simila...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/j.1708-8208.2005.tb00042.x

    authors: Göransson A,Wennerberg A

    更新日期:2005-01-01 00:00:00

  • A long-term prospective cohort study on immediately restored single tooth implants inserted in extraction sockets and healed ridges: CBCT analyses, soft tissue alterations, aesthetic ratings, and patient-reported outcomes.

    abstract:BACKGROUND:Although many studies have been published on single implants, long-term data remain scarce. PURPOSE:To evaluate immediately restored single implants after at least 8 years of follow-up in terms of buccal bone, soft tissue alterations, aesthetic ratings, and patient-reported outcomes. MATERIALS AND METHODS:...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12613

    authors: Raes S,Eghbali A,Chappuis V,Raes F,De Bruyn H,Cosyn J

    更新日期:2018-08-01 00:00:00

  • Single-tooth replacement in the anterior maxilla by means of immediate implantation and early loading: clinical and aesthetic results at 5 years.

    abstract:BACKGROUND:The hypothesis of the present study was that the early loading of single implants-supported restorations, replacing single extracting teeth in the anterior region of the maxilla in case of fresh extraction sockets with residual hard and soft tissue preservation, could be a successful procedure. METHODS:Twen...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章

    doi:10.1111/cid.12111

    authors: Guarnieri R,Ceccherini A,Grande M

    更新日期:2015-04-01 00:00:00

  • Osseointegrated implant for single-tooth replacement: a retrospective multicenter study on routine use in private practice.

    abstract:BACKGROUND:Implant restorations first started with total edentulism. Later, the scientific community gave its approval for restorations in partial edentulism, and only recently some studies confirmed the validity of the treatment for single-tooth replacement. PURPOSE:The purpose of the study was to evaluate implant su...

    journal_title:Clinical implant dentistry and related research

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1708-8208.2000.tb00006.x

    authors: Bianco G,Di Raimondo R,Luongo G,Paoleschi C,Piccoli P,Piccoli C,Rangert B

    更新日期:2000-01-01 00:00:00