ICSH recommendations for the measurement of haemoglobin F.

Abstract:

:Measurement of the Haemoglobin F in red cell haemolysates is important in the diagnosis of δβ thalassaemia, hereditary persistence of fetal haemoglobin (HPFH) and in the diagnosis and management of sickle cell disease. The distribution of Hb F in red cells is useful in the diagnosis of HPFH and in the assessment of feto-maternal haemorrhage. The methods of quantifying Hb F are described together with pitfalls in undertaking these laboratory tests with particular emphasis on automated high-performance liquid chromatography and capillary electrophoresis.

journal_name

Int J Lab Hematol

authors

Stephens AD,Angastiniotis M,Baysal E,Chan V,Davis B,Fucharoen S,Giordano PC,Hoyer JD,Mosca A,Wild B,International Council for The Standardisation of Haematology (ICSH).

doi

10.1111/j.1751-553X.2011.01367.x

subject

Has Abstract

pub_date

2012-02-01 00:00:00

pages

14-20

issue

1

eissn

1751-5521

issn

1751-553X

journal_volume

34

pub_type

杂志文章,实务指引
  • Multicentric evaluation of the new HemosIL Acustar® chemiluminescence ADAMTS13 activity assay.

    abstract:INTRODUCTION:Thrombotic thrombocytopenic purpura (TTP) is a rare life-threatening thrombotic microangiopathy (TMA) characterized by the severe deficiency of ADAMTS13 activity (<10%). Rapid ADAMTS13 testing is crucial for early diagnosis and optimal management of TTP patients and other TMAs. The objective of this study ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13414

    authors: Pascual C,Nieto JM,Fidalgo T,Seguí IG,Díaz-Ricart M,Docampo MF,Del Rio J,Salinas R

    更新日期:2020-12-02 00:00:00

  • Three novel alternative splicing mutations in BCR-ABL1 detected in CML patients with resistance to kinase inhibitors.

    abstract:INTRODUCTION:Multiple types of mutations in the BCR-ABL1 kinase domain have been reported. We previously reported a common alternatively spliced BCR-ABL mRNA with a 35-nucleotide insertion (35INS). We report three novel alternative splicing mutants expressed as the dominant transcripts in patient with chronic myelogeno...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01291.x

    authors: Ma W,Giles F,Zhang X,Wang X,Zhang Z,Lee TS,Yeh CH,Albitar M

    更新日期:2011-06-01 00:00:00

  • Abrogation of red blood cell G6PD enzyme activity through Heat treatment: development of survey material for the UK NEQAS G6PD scheme.

    abstract:INTRODUCTION:Participation in external quality assessment (EQA) is central to the maintenance of high-quality laboratory results in patient diagnosis and clinical trials. Laboratories in the TAF112582 DETECTIVE study (ClinicalTrials.gov identifier: NCT01376167) are enrolled in the United Kingdom National Quality Assess...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12627

    authors: Roper DR,De la Salle B,Soni V,Fletcher K,Green JA

    更新日期:2017-06-01 00:00:00

  • Morphologic identification of atypical chronic lymphocytic leukemia by digital microscopy.

    abstract:INTRODUCTION:Atypical chronic lymphocytic leukemia (aCLL) is a morphologic variant found in approximately 25% of patients with chronic lymphocytic leukemia (CLL). Although aCLL has a more aggressive course compared to typical CLL (tCLL), it is not usually reported. This retrospective study used digital microscopy to mo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12167

    authors: Marionneaux S,Maslak P,Keohane EM

    更新日期:2014-08-01 00:00:00

  • Establishment of reference intervals for pediatric complete capillary blood counts: A multicenter study in Beijing.

    abstract:INTRODUCTION:Clinical reference intervals represent the normal range of clinical parameters for distinguishing healthy and sick individuals, and they show some variation among different populations. Many reference intervals are still lacking for the pediatric population in China. Thus, the aim of this study was to esta...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13150

    authors: Sun Q,Yue Y,Tian Y,Wang Q

    更新日期:2020-10-01 00:00:00

  • Factor VII assay performance: an analysis of the North American Specialized Coagulation Laboratory Association proficiency testing results.

    abstract::The performance of factor VII (FVII) assays currently used by clinical laboratories was examined in North American Specialized Coagulation Laboratory Association (NASCOLA) proficiency tests. Data from 12 surveys conducted between 2008 and 2010, involving 20 unique specimens plus four repeat-tested specimens, were anal...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12083

    authors: Zantek ND,Hsu P,Refaai MA,Ledford-Kraemer M,Meijer P,Van Cott EM

    更新日期:2013-06-01 00:00:00

  • Performance evaluation of the Sysmex(®) XP-300 in an oncology setting: evaluation and comparison of hematological parameters with the Sysmex(®) XN-3000.

    abstract:INTRODUCTION:The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ijlh.12522

    authors: van Dievoet MA,Louagie H,Ghys T

    更新日期:2016-10-01 00:00:00

  • IgG subclasses of FVIII inhibitors in an argentine cohort of severe hemophilia A patients: Analysis by flow cytometry.

    abstract:INTRODUCTION:FVIII inhibitors consist of a polyclonal population of antibodies. Previous studies have demonstrated different distribution of IgG subclasses. IgG4 was associated to high level of FVIII inhibitors and failure of immune tolerance induction (ITI) treatment. This study monitored the relative distribution of ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12696

    authors: Irigoyen MB,Primiani L,Felippo M,Candela M,de Bracco MME,Galassi NV

    更新日期:2017-12-01 00:00:00

  • The role of automated measurement of red cell subpopulations on the Sysmex XE 5000 analyzer in the differential diagnosis of microcytic anemia.

    abstract::Cell counter-based formulae have been used in the differential diagnosis of microcytic anemia. The measurement of new red cell parameters is now available on the Sysmex XE 5000 analyzer. Derived from the percentages of microcytic and hypochromic red cells, the authors describe the new formula %microcytic-%hypochromic,...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01237.x

    authors: Urrechaga E,Borque L,Escanero JF

    更新日期:2011-02-01 00:00:00

  • Assessing maternal clotting function with novel global coagulation assays: A prospective pilot study.

    abstract:INTRODUCTION:Women are at higher risk of venous thromboembolism (VTE) during pregnancy and the puerperium. Global coagulation assays (GCAs), including thromboelastography (TEG), thrombin generation using the calibrated automated thrombogram (CAT) and fibrin generation using the overall haemostatic potential assay (OHP)...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13389

    authors: O'Keefe D,Lim HY,Tham J,Ho P,Hui L

    更新日期:2020-11-10 00:00:00

  • Analytical comparison between two hematological analyzer systems: CAL-8000 vs. XN-9000.

    abstract:INTRODUCTION:This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL-8000 and XN-9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). METHODS:A total of 1025 peripheral blo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12597

    authors: Buoro S,Mecca T,Seghezzi M,Manenti B,Azzarà G,Dominoni P,Crippa A,Ottomano C,Lippi G

    更新日期:2017-04-01 00:00:00

  • Paroxysmal nocturnal haemoglobinuria. Experience over a 10 years period.

    abstract:INTRODUCTION:Paroxysmal nocturnal hemoglobinuria (PNH) is a hemolytic, clonal and acquired disorder of the hematopoietic stem cell with a deficiency of all glycophosphatidyl-inositol (GPI) linked proteins. The aim of this retrospective study was to analyse haematological and biochemical data from 152 patients referred ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12156

    authors: Canalejo K,Riera Cervantes N,Felippo M,Sarandría C,Aixalá M

    更新日期:2014-04-01 00:00:00

  • Entonox as a sedative for bone marrow aspiration and biopsy.

    abstract::Bone marrow aspiration and biopsy can be a painful procedure. Sedation techniques may make this investigation more acceptable to patients, but have the potential to cause life-threatening complications, as well as requiring additional staff and equipment for safe administration. We assessed the use of Entonox, a 50 : ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1751-553X.2007.00905.x

    authors: Gudgin EJ,Besser MW,Craig JI

    更新日期:2008-02-01 00:00:00

  • Evaluation of an automated algorithm for interpretation of lupus anticoagulant testing.

    abstract:INTRODUCTION:Lupus anticoagulant (LAC) testing is a multistep procedure including screening, mixing, and confirmation tests. STA Coag Expert is a software module for STA R Max and STA Compact Max analyzers which includes an on-demand LAC algorithm, based on ISTH guidelines, for automatic interpretation, calculation, an...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13001

    authors: Florin L,Desloovere M,Devreese KMJ

    更新日期:2019-06-01 00:00:00

  • The adsorption of dabigatran is as efficient as addition of idarucizumab to neutralize the drug in routine coagulation assays.

    abstract:INTRODUCTION:The direct thrombin inhibitor dabigatran interferes with thrombophilia screening and with the diagnosis of hemostasis disorders that develop during treatment with the anticoagulant. In vitro addition of idarucizumab, a humanized antibody fragment that binds dabigatran, to plasma samples containing dabigatr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12807

    authors: Jacquemin M,Toelen J,Feyen L,Schoeters J,Van Horenbeeck I,Vanlinthout I,Debasse M,Vanassche T,Peerlinck K,Verhamme P

    更新日期:2018-08-01 00:00:00

  • Quantification of hemoglobin Constant Spring in heterozygote and homozygote by a capillary electrophoresis method.

    abstract:INTRODUCTION:Capillary electrophoresis (CE) is a high-resolution method for detection of hemoglobin Constant Spring (Hb CS). METHODS:The levels of Hb CS quantified by CE were compared among three groups of samples including heterozygote and homozygote of Hb CS as well as Hb H-CS disease classified by DNA molecular dia...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01371.x

    authors: Pornprasert S,Panyasai S,Waneesorn J,Kongthai K,Singboottra P

    更新日期:2012-04-01 00:00:00

  • The hematology laboratory's response to the COVID-19 pandemic: A scoping review.

    abstract::The ongoing COVID-19 pandemic has had a profound worldwide impact on the laboratory hematology community. Nevertheless, the pace of COVID-19 hematology-related research has continued to accelerate and has established the role of laboratory hematology data for many purposes including disease prognosis and outcome. The ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13381

    authors: Bell R,Zini G,d'Onofrio G,Rogers HJ,Lee YS,Frater JL

    更新日期:2020-11-12 00:00:00

  • A level-headed approach to measuring direct oral anticoagulants: A 2-year retrospective analysis of DOAC levels from a tertiary UK centre.

    abstract:INTRODUCTION:Direct oral anticoagulants (DOAC) are commonly prescribed and measuring drug levels may be useful in a number of contexts. However, data on DOAC level measurement and their clinical utility in real-world studies are limited. METHODS:We carried out a 2-year retrospective cohort study of DOAC levels measure...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12944

    authors: Denny NDR,Keighley L,Siganporia Z,Thachil J,Nash MJ

    更新日期:2019-04-01 00:00:00

  • Utility of new mature erythrocyte and reticulocyte indices in screening for iron-deficiency anemia in a pediatric population.

    abstract:INTRODUCTION:Iron-deficient erythropoiesis attributable to nutritional deficiency is the most common cause of anemia in early childhood. Beckman Coulter has proposed new parameters: red blood cell size factor (RSf) and low hemoglobin density (LHD%). [Formula: see text] The aims of the present communication were to esta...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12030

    authors: Osta V,Caldirola MS,Fernandez M,Marcone MI,Tissera G,Pennesi S,Ayuso C

    更新日期:2013-08-01 00:00:00

  • A study of disseminated intravascular coagulation in acute leukemia reveals markedly elevated D-dimer levels are a sensitive indicator of acute promyelocytic leukemia.

    abstract:INTRODUCTION:While the presence of disseminated intravascular coagulation (DIC) has been implicated in worse clinical outcome in acute leukemia, the relationship between different subtypes of acute leukemia and the clinicopathologic features of DIC has not been systematically well studied. METHODS:In this study, we re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12636

    authors: Shahmarvand N,Oak JS,Cascio MJ,Alcasid M,Goodman E,Medeiros BC,Arber DA,Zehnder JL,Ohgami RS

    更新日期:2017-08-01 00:00:00

  • Association of mean platelet volume and platelet count with the development and prognosis of ischemic and hemorrhagic stroke.

    abstract:INTRODUCTION:Mean platelet volume (MPV) and platelet (PLT) count are the two major parameters that reflect the functions and activities of PLTs. The associations of MPV and PLT count with the occurrence and prognosis of stroke have not been fully clarified. This study aimed to investigate the association of MPV and PLT...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/ijlh.12474

    authors: Du J,Wang Q,He B,Liu P,Chen JY,Quan H,Ma X

    更新日期:2016-06-01 00:00:00

  • International Council for Standardization in Haematology (ICSH) laboratory guidance for the evaluation of haemostasis analyser-reagent test systems. Part 1: Instrument-specific issues and commonly used coagulation screening tests.

    abstract::Before a new method is used for clinical testing, it is essential that it is evaluated for suitability for its intended purpose. This document gives guidance for the performance of verification, validation and implementation processes required by regulatory and accreditation bodies. It covers the planning and executio...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13411

    authors: Gardiner C,Coleman R,de Maat MPM,Dorgalaleh A,Echenagucia M,Gosselin RC,Ieko M,Kitchen S

    更新日期:2020-11-29 00:00:00

  • Case report of HbC/beta(0)-thalassemia from India.

    abstract::This 22-year-old women presented to the ante-natal clinic of this hospital for prenatal screening for beta-thalassemia. Cation exchange high performance liquid chromatography (HPLC) using 'Beta Thalassemia Short Program' on Bio-Rad 'Variant' system revealed HbC value of 81.6%. The CBC showed microcytic hypochromic ane...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00850.x

    authors: Kumar S,Rana M,Handoo A,Saxena R,Verma IC,Bhargava M,Sood SK

    更新日期:2007-10-01 00:00:00

  • Clinical and hematological characteristics of 88 patients with COVID-19.

    abstract:INTRODUCTION:To retrospectively analyze epidemiological, clinical and hematological characteristics of COVID-19 patients. METHODS:The demographic, symptoms, and physiological parameters of 88 patients were collected and analyzed. The performance of complete blood count (CBC) indexes for monitoring and predicting the s...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13291

    authors: Zhang H,Cao X,Kong M,Mao X,Huang L,He P,Pan S,Li J,Lu Z

    更新日期:2020-12-01 00:00:00

  • Expression analysis of BECN1 in acute myeloid leukemia: association with distinct cytogenetic and molecular abnormalities.

    abstract:INTRODUCTION:In acute myeloid leukemia (AML), it has been shown that AML-derived cells often remain sensitive to autophagy-inducing stimuli, leading to the idea that harnessing the autophagy can be pertinent to AML cytotoxic therapy. Despite this promising notion, to date, there is no comprehensive study addressing aut...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12454

    authors: Zare-Abdollahi D,Safari S,Movafagh A,Ghadiani M,Tabarraee M,Riazi-Isfahani S,Gorji S,Keyvan L,Gachkar L

    更新日期:2016-04-01 00:00:00

  • Hemostasis critical values among Iranian clinical laboratories "National Survey of 157 Clinical Laboratories".

    abstract:BACKGROUND:Immediate reporting of critical values or test results significantly outside the normal range has a growing role in the management of patients, especially in life-threatening conditions. Due to the lack of international consensus, diverse approaches are used for determination of thresholds, reporting, docume...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13109

    authors: Dorgalaleh A,Shiravand Y,Dabbagh A,Tabibian S,Hosseini MS,Mansouri Tourghabeh H,Rashidpanah J,Narouei F,Shams M,Gholami MS,Saneei Moghaddam E,Shahreki H

    更新日期:2019-12-01 00:00:00

  • Flow cytometry data analysis: Recent tools and algorithms.

    abstract::Flow cytometry (FCM) allows scientists to rapidly quantify up to 50 parameters for millions of cells per sample. The bottleneck in the application of the technology is data analysis, and the high number of parameters measured by the current generation of instruments requires the use of advanced computational algorithm...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13016

    authors: Montante S,Brinkman RR

    更新日期:2019-05-01 00:00:00

  • The evaluation of the relevance of thrombin generation and procoagulant activity in thrombotic risk assessment in BCR-ABL-negative myeloproliferative neoplasm patients.

    abstract:INTRODUCTION:It has been recently suggested that microparticles (MP) play a role in the pathogenesis of thrombotic complications. This study aimed to assess the contribution of procoagulant activity expressed by circulating MP in thrombotic events in MPN patients. METHODS:Seventy-four MPN patients were enrolled in a t...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12676

    authors: Baccouche H,Ben Jemaa M,Chakroun A,Chadi S,Mahjoub S,Sfar I,Gorgi Y,Ben Romdhane N

    更新日期:2017-10-01 00:00:00

  • A rare case of Lennert's type peripheral T-cell lymphoma with t(14;19)(q11.2;q13.3).

    abstract::Although most patients with peripheral T-cell lymphoma (PTCL) show clonal rearrangement of T-cell receptor genes, few PTCLs show recurrent chromosomal abnormalities. We describe here a rare chromosomal rearrangement, t(14;19)(q11.2;q13.3), in a Lennert's lymphoma, a variant of PTCL, not otherwise specified. Sequential...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01385.x

    authors: Shin SY,Jang S,Park CJ,Chi HS,Lee KH,Huh J,Seo EJ

    更新日期:2012-06-01 00:00:00

  • How I investigate for bleeding disorders.

    abstract:INTRODUCTION:Laboratory investigations for bleeding disorders are warranted when an individual has a personal and/or family history of bleeding, and/or laboratory findings that suggest the possibility of an inherited or acquired bleeding disorder. METHODS:This review summarizes author's experience with ordering and re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12822

    authors: Hayward CPM

    更新日期:2018-05-01 00:00:00