Abstract:
PURPOSE:To evaluate the effect of transarterial pulsed perfusion with 60 °C saline on vascular permeability of tumor tissue, as well as its hepatic and renal toxicity, in a rabbit VX2 liver model. MATERIALS AND METHODS:VX2 carcinomas were grown in rabbit livers, forty male New Zealand white tumor-bearing rabbits were randomly divided into four groups, followed by transarterial perfusion with 37 °C saline 60 ml (n=10) (control 1 group), transarterial pulsed perfusion with 37 °C saline 60 ml (n=10) (control 2 group), transarterial continuous perfusion with 60 °C saline 60 ml (n=10) (TCP group), transarterial pulsed perfusion with 60 °C saline 60 ml (n=10) (TPP group), the duration of time for tumor tissues in the range 43-45 °C of the treated groups was measured with needle thermometer during perfusion. Vascular permeability was assessed using the extravasation of Evans blue (EB) dye in the tumor or normal liver tissues of the four groups separately, the tumor or normal liver tissues of the four groups were estimated by histopathologic examination, and hepatic and renal toxicity was evaluated by means of blood biochemical analysis. The vascular endothelial cells in the tumor were observed by transmission electron microscopy (TEM). RESULTS:The duration of time for tumor tissues in the range 43-45 °C of TPP group showed significantly longer than that of TCP group (12.3±3.3 min vs. 5.7±2.5 min) (P<0.01). After perfusion, the EB content of tumor tissue in TPP group showed significantly higher than that in TCP group (15.21±0.94 μg/100 mg vs. 10.71±0.84 μg/100 mg) (P<0.01), and also showed significantly higher than that in the two control group (3.42±0.87 μg/100 mg, 3.57±0.64 μg/100 mg) (P<0.01). Blood chemical analysis indicating there was an increase (P<0.05) in the serum ALT, AST levels in the two heated perfusion groups at 1, 2, 4, 8 h after infusion when compared to that in the two control group, but there was no significant difference in the serum ALT, AST levels among the four groups at 24 h after perfusion (P>0.05), and there was no significant difference in the serum BUN, Cr levels among the four groups at 1, 2, 4, 8, 24 h after perfusion. Observed by hematoxylin and eosin staining, there were no obvious signs of tissue destruction in liver tissue and tumor tissue. TEM indicating the endothelial cell gap was broadened and the endothelial cells' microvillus was decreased after heated perfusion. CONCLUSIONS:The vascular permeability of the rabbit VX2 tumor was significantly increased after transarterial pulsed perfusion with 60°C saline without significant increase in hepatic and renal toxicity.
journal_name
Eur J Radioljournal_title
European journal of radiologyauthors
Cao W,Li JH,Feng DY,Wan Y,Liu YF,Yang QF,Cheng JW,Zhao SY,Zhang HXdoi
10.1016/j.ejrad.2011.01.108subject
Has Abstractpub_date
2012-03-01 00:00:00pages
e209-16issue
3eissn
0720-048Xissn
1872-7727pii
S0720-048X(11)00167-7journal_volume
81pub_type
杂志文章abstract:OBJECTIVE:To evaluate the efficacy and safety of sonography-guided percutaneous microwave ablation of intrahepatic primary cholangiocarcinoma. MATERIALS AND METHODS:From May 2006 to March 2010, 15 patients (11 men, 4 women; mean age, 57.4 years) with 24 histologically proven intrahepatic primary cholangiocarcinoma les...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.01.014
更新日期:2011-11-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Although isotropic diffusion-weighted imaging (isoDWI) is very sensitive to the detection of acute ischemic stroke, it may occasionally show diffusion negative result in hyper-acute stroke. We hypothesize that high diffusion contrast diffusion trace-weighted image with enhanced T2 may improve str...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2009.04.023
更新日期:2010-06-01 00:00:00
abstract:OBJECTIVE:To assess computed tomography (CT) evaluation of mediastinal nodes in non-small cell lung cancer to predict metastatic involvement by measurement of their axis and surface area in the coronal plane, as compared to standard short-axis measures in the axial plane. METHODS:Evaluation of mediastinal nodes was re...
journal_title:European journal of radiology
pub_type: 临床试验,杂志文章
doi:10.1016/j.ejrad.2011.06.015
更新日期:2012-09-01 00:00:00
abstract::This is a retrospective study of a series of seven patients with pancreatic metastases studied by ultrasonography and computed tomography. They were detected during tumor staging, or in the follow-up period of over 10 years of patients with advanced known malignancy. Lesions were multiple in two patients and solitary ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/0720-048x(91)90131-e
更新日期:1991-01-01 00:00:00
abstract::To introduce an easy and improved technique for performing ductography using inexpensive easily available intravenous cannula. Guide wire: Prolene/Surgipro 3-0 (Polypropylene mono filament non-absorbable surgical suture). A plastic 26 G intravenous cannula. Disposable syringe 2 ml. Non-ionic contrast (low density like...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.03.050
更新日期:2012-07-01 00:00:00
abstract::In this study, we evaluated a large number of subjects using BOLD MRI to provide more information about oxygen metabolism in the normal function of transplanted kidneys and to distinguish acute graft rejection from normal function kidneys. This study included 122 subjects (20 volunteers, 72 patients with normal functi...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.02.041
更新日期:2012-05-01 00:00:00
abstract::CT colonography (CTC), or virtual colonoscopy, is a non-invasive imaging method that uses CT data sets combined with specialized imaging software to examine the colon. CTC is not used routinely in patients with inflammatory bowel disease (IBD). However, investigating contemporarily the colon, other abdominal organs an...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/j.ejrad.2008.11.027
更新日期:2009-03-01 00:00:00
abstract:OBJECTIVE:To correlate CTA pulmonary artery obstruction scores (OS) with right ventricular dysfunction (RVD) and clinical outcome in patients with acute pulmonary embolism (PE). MATERIALS AND METHODS:In a prospective study of 50 patients (66 ± 12.9 years) with PE pulmonary artery OS (Qanadli, Mastora, and Mastora cent...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.08.014
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To report the diffusion-weighted MRI findings in alveolar echinococcosis (AE) of the liver and evaluate the potential role of apparent diffusion coefficients (ADCs) in the characterisation of lesions. MATERIALS AND METHODS:We retrospectively included 22 patients with 63 AE liver lesions (≥1 cm), examined with ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.12.025
更新日期:2014-04-01 00:00:00
abstract::The aim of this study was to investigate the combined effects of liquid crystal display (LCD) resolution, image magnification and window/level adjustment on the low-contrast performance in soft-copy image interpretation in digital radiography and digital mammography. In addition, the effect of a new LCD noise reductio...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2005.12.016
更新日期:2006-06-01 00:00:00
abstract::We report a case of fibrolamellar carcinoma presenting in a 26-year old female. The patient had gross ascites at presentation. Imaging studies (ultrasonography and computed tomography) strongly suggested extensive intraperitoneal drop metastases. ...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/s0720-048x(99)00137-0
更新日期:1999-11-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to compare the diagnostic accuracy of 64-slice CT with that of invasive angiography in the detection of graft and/or coronary angioplasty stenosis in children who had undergone coronary artery surgery. POPULATION AND METHODS:Fifteen consecutive children (8 male and 7 female; age...
journal_title:European journal of radiology
pub_type: 临床试验,杂志文章
doi:10.1016/j.ejrad.2008.06.008
更新日期:2009-09-01 00:00:00
abstract:OBJECTIVE:To assess the diagnostic accuracy of multi-detector-row computed tomography (MDCT) for the detection of ampullary adenomas or adenocarcinomas in situ. MATERIALS AND METHODS:We retrospectively reviewed 21 computed tomography (CT) images from 20 patients with ampullary tumors, and 22 CT images from 22 patients...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2010.10.022
更新日期:2011-12-01 00:00:00
abstract:PURPOSE:To assess the relationship between imaging follow-up and all-cause mortality in subjects ≥65 years with and without incidental pancreatic cysts (IPC). METHODS AND MATERIALS:Patients ≥65 years with abdominal CT/MR 11/1/01-11/1/11 were included. IPC group included subjects with IPC on CT/MR report; No-IPC group ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2016.03.008
更新日期:2016-06-01 00:00:00
abstract:OBJECTIVES:Anemia is associated with increased mortality in patients with acute symptomatic pulmonary embolism (PE). The purpose of this study was to evaluate the feasibility of Hounsfield unit (HU) measurements on the single unenhanced trigger slice of pulmonary CT angiography scans for diagnosis of anemia. MATERIAL ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.07.008
更新日期:2012-12-01 00:00:00
abstract:PURPOSE:Brain metastasis (BM) is the primary first failure pattern in patients with curatively resected locally advanced non-small cell lung cancer (LA-NSCLC). It is not yet possible to accurately predict the occurrence of BM. The purpose of the research is to develop and validate a prediction model of BM-free survival...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2020.109411
更新日期:2021-01-01 00:00:00
abstract:PURPOSE:To examine technical parameters of measurement accuracy and differences in tumor response classification using RECIST 1.1 and volumetric assessment in three common metastasis types (lung nodules, liver lesions, lymph node metastasis) simultaneously. MATERIALS AND METHODS:56 consecutive patients (32 female) age...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.05.030
更新日期:2013-10-01 00:00:00
abstract:OBJECTIVES:Various percent canal occlusion measurement methods have been used to assess the spinal canal stenosis following a thoracolumbar burst fracture. However, there are no studies performed comparing these techniques. The objective of this study was to determine the reliability of three techniques used to measure...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2007.08.020
更新日期:2008-09-01 00:00:00
abstract:PURPOSE:"Misty mesentery" is a CT appearance of mesenteric fat changes with increased attenuation often existing with swelled mesenteric lymph nodes. We evaluated diagnostic performance of FDG-PET/CT in distinguishing viable malignant disorders from benign conditions in misty mesentery. MATERIALS AND METHODS:4236 FDG-...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.03.016
更新日期:2013-08-01 00:00:00
abstract:OBJECTIVE:To assess the role of apparent diffusion coefficient (ADC) measured with diffusion-weighted imaging (DWI) in predicting and assessing response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). METHODS:Thirty-six patients with cirrhosis and untreated HCC who underwent TACE and MRI w...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.11.026
更新日期:2013-04-01 00:00:00
abstract:PURPOSE:To obtain diffusion and microperfusion measures in lymph node metastases of head and neck squamous cell carcinomas (HNSCC) using intravoxel incoherent motion (IVIM) imaging. The obtained IVIM parameters were used to characterize lymph nodes in the staging phase and longitudinal follow-up was performed to evalua...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2014.02.013
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:The purpose of this retrospective study was to examine the reliability of virtually estimated abdominal blood volume using segmentation from postmortem computed tomography (PMCT) data. MATERIALS AND METHODS:Twenty-one cases with free abdominal blood were investigated by PMCT and autopsy. The volume of the bloo...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2011.09.014
更新日期:2012-09-01 00:00:00
abstract:PURPOSE:To investigate the factors that could cause a misdiagnosis in virtual touch tissue imaging and quantification (VTIQ) when differentiating benign and malignant breast lesions, and to analyze the imaging characteristics of those lesions with incorrect findings. METHODS:The conventional ultrasound (CUS) features ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2018.11.021
更新日期:2019-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to characterize gliomatosis cerebri on magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), and to analyze the value of these two techniques in diagnosis and differential diagnosis of gliomatosis cerebri. MATERIALS AND METHODS:MR images of 14 patients with g...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2006.03.001
更新日期:2006-08-01 00:00:00
abstract::The management of patients with spinal trauma is based on the following goals: (1) the preservation of life; (2) preserving and maximising the neurological function; and (3) providing a stable, painless vertebral column. There have been advances in both non operative as well operative modalities of treatment of patien...
journal_title:European journal of radiology
pub_type: 杂志文章,评审
doi:10.1016/s0720-048x(02)00045-1
更新日期:2002-05-01 00:00:00
abstract:INTRODUCTION:To identify liver stiffness (LS) cut-off values assessed by means of 2D-Shear Wave Elastography (2D-SWE) for predicting different stages of liver fibrosis, considering Transient Elastography (TE) as the reference method. METHODS:Our prospective study included 383 consecutive subjects, with or without hepa...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2013.12.011
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVE:To analyze the characteristics of double inversion recovery (DIR) turbo field echo (TFE) and turbo spin echo (TSE) sequences and explore the value of double inversion recovery TFE sequence on carotid artery wall imaging. PATIENTS AND METHODS:56 patients (32 males and 24 females, aged 31-76 years with a mean ...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2010.12.048
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:To investigate the diagnostic value of T1 mapping imaging of evaluating fibrosis in patients with hypertrophic cardiomyopathy (HCM). MATERIALS AND METHODS:21 subjects with HCM and 18 healthy volunteers underwent conventional late gadolinium enhancement (LGE) imaging and T1 mapping imaging. The region of myocar...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2012.12.014
更新日期:2013-05-01 00:00:00
abstract:OBJECTIVE:to study various phosphors used in detectors of medical imaging systems by the gain transfer function (GTF), defined in terms of X-ray luminescence efficiency, light spectrum and modulation transfer function. MATERIALS AND METHODS:four phosphor materials, La(2)O(2)S:Tb, Y(2)O(2)S:Tb, Y(2)O(2)S:Eu and Y(2)O(3...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/s0720-048x(99)00106-0
更新日期:2000-07-01 00:00:00
abstract:OBJECTIVES:To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. METHODS:From April 2015 to Marc...
journal_title:European journal of radiology
pub_type: 杂志文章
doi:10.1016/j.ejrad.2016.12.021
更新日期:2017-02-01 00:00:00