Telomerase activity and telomere length in acute leukemia: correlations with disease progression, subtypes and overall survival.

Abstract:

:The progressive shortening of telomeres and the activation of telomerase are considered to be one of the important mechanisms in cellular immortalization and disease progression. Bone marrow samples were collected from 148 patients with acute leukemia (AL). Based on the stage of the disease, patients were divided into the newly diagnosed group, the relapsed group and the complete remission (CR) group. telomerase activity (TA) was examined by PCR-ELISA, and telomere length (TL) was examined by Southern blot analyses. TA and TL were analyzed in relation to AL stage and subtype. Five-year survival was analyzed using Kaplan-Meier survival curve. TA in AL patients was higher than healthy individuals. TA level was the highest in the relapsed group, followed by the newly diagnosed group, and then the CR group. TA had no difference between acute nonlymphocytic leukemia (ANLL) group and acute lymphocytic leukemia (ALL) group. But TA in group of subtype M3 was lower than other subtypes of ANLL. TL in AL group was shorter than the control group. TL was the shortest in the relapsed group, followed by the newly diagnosed group, and finally the CR group. TL exhibited an inverse correlation with TA. The group of patients with high TA had a significantly poorer five-year-survival than that of low TA group. TA is elevated and TL is shortened in AL patients. There is a significant inverse correlation between TL and TA. Patients in late-stage disease had shorter TL and higher TA than those in early stages. The shortened TL and elevated TA correlated with disease progression and relapse, and they may serve as prognostic factors for AL patients with poor outcome. M3 subtype is special with relative lower TA and long-lasting survival than other subtypes.

journal_name

Int J Lab Hematol

authors

Wang Y,Fang M,Sun X,Sun J

doi

10.1111/j.1751-553X.2009.01178.x

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

230-8

issue

2

eissn

1751-5521

issn

1751-553X

pii

CLH1178

journal_volume

32

pub_type

杂志文章
  • ICSH guidelines for the standardization of bone marrow specimens and reports.

    abstract::The bone marrow examination is an essential investigation for the diagnosis and management of many disorders of the blood and bone marrow. The aspirate and trephine biopsy specimens are complementary and when both are obtained, they provide a comprehensive evaluation of the bone marrow. The final interpretation requir...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,实务指引

    doi:10.1111/j.1751-553X.2008.01100.x

    authors: Lee SH,Erber WN,Porwit A,Tomonaga M,Peterson LC,International Council for Standardization In Hematology.

    更新日期:2008-10-01 00:00:00

  • Chronic active Epstein-Barr virus infection: A heterogeneous entity requiring a high index of suspicion for diagnosis.

    abstract::Chronic active Epstein-Barr virus infection of T- and NK-cell type, systemic form, is a rare entity within the spectrum of EBV-driven T- and NK-cell lymphoproliferative disorders. Established diagnostic criteria and a characteristic clinical course help to differentiate it from other closely related EBV-positive neopl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13199

    authors: Ondrejka SL,Hsi ED

    更新日期:2020-06-01 00:00:00

  • Expression of CD4 is correlated with an unfavorable prognosis in wild-type NPM1, FLT3-ITD-negative cytogenetically normal adult acute myeloid leukemia.

    abstract:INTRODUCTION:In the cytogenetically normal population of AML (CN-AML), FLT3-ITD-positive and wild-type NPM1 is correlated with a worse outcome, and FLT3-ITD-negative with NPM1-mut is correlated with a better outcome. This leaves a large subpopulation of CN-AML patients without NPM1 or FLT3-ITD mutations with heterogene...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12649

    authors: Guo RJ,Atenafu EG,Schimmer AD,Minden MD,Chang H

    更新日期:2017-08-01 00:00:00

  • Hematopoietic stem cell lodgment in the adult bone marrow stem cell niche.

    abstract::Treatment of malignant blood disorders, such as leukemia, that can provide a better chance of long-term remission involves myeloablation followed by transplantation of matched donor hematopoietic stem cells (HSCs). For successful engraftment and re-establishment of hematopoiesis to occur in the recipient, the transpla...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2010.01250.x

    authors: Lam BS,Adams GB

    更新日期:2010-12-01 00:00:00

  • Use of Sysmex XN-10 red blood cell parameters for screening of hereditary red blood cell diseases and iron deficiency anaemia.

    abstract:INTRODUCTION:In daily practice in haematology laboratories, red blood cell (RBC) abnormalities are frequent and their management is a real challenge. The aim of this study is to establish a "decision tree" using RBC and reticulocyte parameters from the SYSMEX XN-10 analyser to distinguish between patients with a heredi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13278

    authors: Nivaggioni V,Bouriche L,Coito S,Le Floch AS,Ibrahim-Kosta M,Leonnet C,Arnoux I,Loosveld M

    更新日期:2020-12-01 00:00:00

  • Morphologic and cytogenetic variables affect the flow cytometric recovery of plasma cell myeloma cells in bone marrow aspirates.

    abstract:INTRODUCTION:It is widely recognized that plasma cells (PCs) are under-represented in flow cytometry (FC) studies, but the causes of this phenomenon are poorly understood. We sought to study potential variables that affect PC recovery by flow cytometry (FC) in the analysis of plasma cell myeloma (PCM). METHODS:We retr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12411

    authors: Cogbill CH,Spears MD,Vantuinen P,Harrington AM,Olteanu H,Kroft SH

    更新日期:2015-12-01 00:00:00

  • Establishment of reference intervals for complete blood count parameters in venous blood for children in the Xiamen area, China.

    abstract:OBJECTIVES:To observe changes in the complete blood count (CBC) venous blood parameters of healthy children and establish appropriate reference intervals (RIs). METHODS:Overall, 4066 healthy children were selected and divided into four groups: infants, toddlers, preschool-age children and school-age children. Venous b...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13095

    authors: Li J,Zhang H,Huang X,Zhang J,Wu X

    更新日期:2019-10-01 00:00:00

  • Transillumination: a new tool to eliminate the impact of venous stasis during the procedure for the collection of diagnostic blood specimens for routine haematological testing.

    abstract:INTRODUCTION:The collection of diagnostic blood specimens for routine haematological testing (RHT) is traditionally performed with tourniquet. However, the transillumination devices based on cold near-infrared LEDs have been formerly proposed as a valuable tool for identifying reliable venous accesses, especially in pa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01305.x

    authors: Lima-Oliveira G,Lippi G,Salvagno GL,Montagnana M,Scartezini M,Guidi GC,Picheth G

    更新日期:2011-10-01 00:00:00

  • Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

    abstract:INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12486

    authors: Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

    更新日期:2016-06-01 00:00:00

  • Inappropriate use of protein C, protein S, and antithrombin testing for hereditary thrombophilia screening: an experience from a large university hospital.

    abstract:INTRODUCTION:Deficiencies of protein C, protein S, and antithrombin are the main inherited risk factors in Thai patients with venous thromboembolism, although the prevalence is not high. METHODS:To evaluate the appropriate use of the testing for these proteins, the test orders of 503 patients were retrospectively revi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01332.x

    authors: Tientadakul P,Chinthammitr Y,Sanpakit K,Wongwanit C,Nilanont Y

    更新日期:2011-12-01 00:00:00

  • The importance of β globin deletion analysis in the evaluation of patients with β thalassemia.

    abstract:INTRODUCTION:Beta globin deletion/duplication analysis may serve as a useful adjunct to sequence analysis. Our purpose was to develop a robust assay for beta globin deletion/duplication analysis and determine its role in evaluating patients with beta thalassemia. METHODS:A single tube semi-quantitative fluorescent PCR...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01287.x

    authors: Mikula M,Buller-Burckle A,Gallivan M,Sun W,Franklin CR,Strom CM

    更新日期:2011-06-01 00:00:00

  • Red blood cell morphology.

    abstract::The foundation of laboratory hematologic diagnosis is the complete blood count and review of the peripheral smear. In patients with anemia, the peripheral smear permits interpretation of diagnostically significant red blood cell (RBC) findings. These include assessment of RBC shape, size, color, inclusions, and arrang...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12082

    authors: Ford J

    更新日期:2013-06-01 00:00:00

  • The impact of long-haul air travel on variables of the athlete's biological passport.

    abstract:INTRODUCTION:Dehydration, fluid shifts or changes in coagulation occurring during air travel can trigger distinct reactions in the haematological system. Athletes are concerned that these effects might impair sporting performance, increase the risk of thrombosis or cause abnormalities in blood values that might be mist...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01450.x

    authors: Schumacher YO,Klodt F,Nonis D,Pottgiesser T,Alsayrafi M,Bourdon PC,Voss SC

    更新日期:2012-12-01 00:00:00

  • Evaluation of an automated algorithm for interpretation of lupus anticoagulant testing.

    abstract:INTRODUCTION:Lupus anticoagulant (LAC) testing is a multistep procedure including screening, mixing, and confirmation tests. STA Coag Expert is a software module for STA R Max and STA Compact Max analyzers which includes an on-demand LAC algorithm, based on ISTH guidelines, for automatic interpretation, calculation, an...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13001

    authors: Florin L,Desloovere M,Devreese KMJ

    更新日期:2019-06-01 00:00:00

  • Evaluation of the CellaVision DM automated microscope in pediatrics.

    abstract::The DM is an automated microscope, which performs WBC differential counts and monitors red cell morphology. The user either validates the cell recognition if the DM has correctly identified the WBCs or reclassifies the WBCs in the good category in case of a DM mis-assignment. Morphological anomalies of leukocytes, red...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01219.x

    authors: Billard M,Lainey E,Armoogum P,Alberti C,Fenneteau O,Da Costa L

    更新日期:2010-10-01 00:00:00

  • Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.

    abstract::The PENTRA 60C(+) hematology analyzer provides a complete blood cell (CBC) count, including a five-part differential (5-DIFF) count and two leukocyte subpopulations, i.e. large immature cells (LIC's) and atypical lymphocytes (ALY's). We evaluated its analytical performance and assessed agreement with the ADVIA 2120, i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01011.x

    authors: Guerti K,Vertessen F,Daniëls L,Van Der Planken M

    更新日期:2009-04-01 00:00:00

  • Assessing nonvitamin K antagonist oral anticoagulants (NOACs) in the laboratory.

    abstract::Nonvitamin K antagonist oral anticoagulants (NOACs) are being used with increasing frequency due to their safety profile, ease of use, and given that therapeutic monitoring is not required. As these agents have only recently been FDA approved, their effect on routine and specialty coagulation assays is not well apprec...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12350

    authors: Gosselin RC,Adcock DM

    更新日期:2015-05-01 00:00:00

  • The evaluation of the relevance of thrombin generation and procoagulant activity in thrombotic risk assessment in BCR-ABL-negative myeloproliferative neoplasm patients.

    abstract:INTRODUCTION:It has been recently suggested that microparticles (MP) play a role in the pathogenesis of thrombotic complications. This study aimed to assess the contribution of procoagulant activity expressed by circulating MP in thrombotic events in MPN patients. METHODS:Seventy-four MPN patients were enrolled in a t...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12676

    authors: Baccouche H,Ben Jemaa M,Chakroun A,Chadi S,Mahjoub S,Sfar I,Gorgi Y,Ben Romdhane N

    更新日期:2017-10-01 00:00:00

  • Low expression of TET2 gene in pediatric acute lymphoblastic leukemia is associated with poor clinical outcome.

    abstract:INTRODUCTION:TET2, a member of the Ten-Eleven translocation gene family, catalyzes the conversion of 5-methylcytosine to 5-hydroxymethylcytosine in DNA. Low expression of TET2 has been reported as a prognostic factor for several types of malignancies in adult patients. However, there have been few data on the effect of...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13099

    authors: Zhang P,Weng WW,Chen P,Zhang Y,Ruan JF,Ba DD,Xu WQ,Tang YM

    更新日期:2019-10-01 00:00:00

  • Evaluation of small-volume tubes for venous and capillary PT (INR) samples.

    abstract:INTRODUCTION:Frequent PT (INR) testing may represent a problem for patients on warfarin treatment, and capillary or small-volume tubes may be more appropriate for such patients. A demand for small-volume tubes also comes from pediatric wards. Yet, while various small-volume tubes are available, they have not been prope...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12387

    authors: Onelöv L,Basmaji R,Svensson A,Nilsson M,Antovic JP

    更新日期:2015-10-01 00:00:00

  • Acute myeloid leukaemia: How to combine multiple tools.

    abstract::The pathogenesis of acute myeloid leukaemias (AML) frequently requires at least 3 mutations in different cellular pathways. In many cases, mutations in proliferation/survival mechanisms and differentiation pathways are involved. Genetic aberrations explain the pathogenesis of AML, provide prognostic criteria and guide...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12831

    authors: Merino A,Boldú L,Ermens A

    更新日期:2018-05-01 00:00:00

  • Toward routine detection of extracellular vesicles in clinical samples.

    abstract::The majority, if not all, of human cell types secrete extracellular vesicles (EVs) into their environment, at least partly as a means of intercellular communication. These secreted vesicles can be detected in most bodily fluids including blood, urine, and saliva. The number of secreted vesicles and their composition i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12247

    authors: van der Meel R,Krawczyk-Durka M,van Solinge WW,Schiffelers RM

    更新日期:2014-06-01 00:00:00

  • Multicentric evaluation of the new HemosIL Acustar® chemiluminescence ADAMTS13 activity assay.

    abstract:INTRODUCTION:Thrombotic thrombocytopenic purpura (TTP) is a rare life-threatening thrombotic microangiopathy (TMA) characterized by the severe deficiency of ADAMTS13 activity (<10%). Rapid ADAMTS13 testing is crucial for early diagnosis and optimal management of TTP patients and other TMAs. The objective of this study ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13414

    authors: Pascual C,Nieto JM,Fidalgo T,Seguí IG,Díaz-Ricart M,Docampo MF,Del Rio J,Salinas R

    更新日期:2020-12-02 00:00:00

  • Red cell membrane disorders.

    abstract::Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12657

    authors: Narla J,Mohandas N

    更新日期:2017-05-01 00:00:00

  • Quantification of hemoglobin Constant Spring in heterozygote and homozygote by a capillary electrophoresis method.

    abstract:INTRODUCTION:Capillary electrophoresis (CE) is a high-resolution method for detection of hemoglobin Constant Spring (Hb CS). METHODS:The levels of Hb CS quantified by CE were compared among three groups of samples including heterozygote and homozygote of Hb CS as well as Hb H-CS disease classified by DNA molecular dia...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01371.x

    authors: Pornprasert S,Panyasai S,Waneesorn J,Kongthai K,Singboottra P

    更新日期:2012-04-01 00:00:00

  • ADAMTS13 activity to von Willebrand factor antigen ratio predicts acute kidney injury in patients with COVID-19: Evidence of SARS-CoV-2 induced secondary thrombotic microangiopathy.

    abstract:INTRODUCTION:Severe COVID-19 is often compounded by a prothrombotic state that is associated with poor outcomes. In this investigation, we aimed to evaluate ADAMTS13 activity, von Willebrand factor level (VWF:Ag), and the corresponding ADAMTS13 activity/VWF:Ag ratio, in patients with COVID-19 and for associations with ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13415

    authors: Henry BM,Benoit SW,de Oliveira MHS,Lippi G,Favaloro EJ,Benoit JL

    更新日期:2020-12-03 00:00:00

  • How I investigate for bleeding disorders.

    abstract:INTRODUCTION:Laboratory investigations for bleeding disorders are warranted when an individual has a personal and/or family history of bleeding, and/or laboratory findings that suggest the possibility of an inherited or acquired bleeding disorder. METHODS:This review summarizes author's experience with ordering and re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12822

    authors: Hayward CPM

    更新日期:2018-05-01 00:00:00

  • Guidance for storing blood samples in laboratories performing complete blood count with differential.

    abstract:INTRODUCTION:The complete blood count (CBC) with differential leukocyte count (DIFF) is an important part of clinical laboratory analyses and provides crucial data for clinicians. Delivery time after blood collection and conditions of storage is known to affect the reliability of results of some hematologic parameters....

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01452.x

    authors: Cornet E,Behier C,Troussard X

    更新日期:2012-12-01 00:00:00

  • Three novel alternative splicing mutations in BCR-ABL1 detected in CML patients with resistance to kinase inhibitors.

    abstract:INTRODUCTION:Multiple types of mutations in the BCR-ABL1 kinase domain have been reported. We previously reported a common alternatively spliced BCR-ABL mRNA with a 35-nucleotide insertion (35INS). We report three novel alternative splicing mutants expressed as the dominant transcripts in patient with chronic myelogeno...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01291.x

    authors: Ma W,Giles F,Zhang X,Wang X,Zhang Z,Lee TS,Yeh CH,Albitar M

    更新日期:2011-06-01 00:00:00

  • Performance evaluation of the Sysmex(®) XP-300 in an oncology setting: evaluation and comparison of hematological parameters with the Sysmex(®) XN-3000.

    abstract:INTRODUCTION:The Sysmex XP-300(®) (XP-300) is a new, fully automated hematology analyzer, designed to generate complete blood counts (CBC) with 3-part differential. In our study, the XP-300 was evaluated as a point-of-care (POC) analyzer in an oncology setting. In which blood samples from patients with different pathol...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/ijlh.12522

    authors: van Dievoet MA,Louagie H,Ghys T

    更新日期:2016-10-01 00:00:00