Abstract:
:Melorheostosis is a rare benign disease of cortical bone most frequently presenting as peripheral hyperostosis with a characteristic "melting wax" appearance on conventional radiographs. The disease most frequently affects the appendicular skeleton and is seen only rarely in the craniofacial bones. We discuss a case of melorheostosis in the nasal cavity and skull base with an atypical radiographic appearance and suggest findings that may differentiate craniofacial melorheostosis from more common entities in this region.
journal_name
J Comput Assist Tomogrjournal_title
Journal of computer assisted tomographyauthors
McDermott M,Branstetter BF 4th,Seethala RRdoi
10.1097/RCT.0b013e3181572998subject
Has Abstractpub_date
2008-09-01 00:00:00pages
825-7issue
5eissn
0363-8715issn
1532-3145pii
00004728-200809000-00028journal_volume
32pub_type
杂志文章abstract::Compressive sensing (CS)-based interior tomography is a state-of-the-art method for accurate image reconstruction from only locally truncated projections. Here, we report our preliminary interior tomography results reconstructed from raw projections of a patient acquired on a GE Discovery CT750 HD scanner. This is the...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e318231c578
更新日期:2011-11-01 00:00:00
abstract:OBJECTIVE:This study is motivated by the possibility of using computed tomography (CT) to detect early coronary atherosclerosis by the increased CT values within the arterial wall resulting from vasa vasorum proliferation. METHODS:Coronary arteries (n = 5) with early atherosclerotic changes were injected with Microfil...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e3181bb0d32
更新日期:2010-03-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to compare the accuracy of 320-row computed tomography angiography (CTA) with conventional coronary angiography. METHODS:Two hundred seventy-four patients with coronary artery disease who received both invasive coronary angiography and 320-row CTA were included. Stenosis of 50...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e31826ab24a
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:To describe CT findings of portal vein anomaly with total ramification of the intrahepatic portal branches from the right umbilical vein. METHODS:Retrospective analysis was performed in 6 patients with portal vein anomaly with total ramification of the intrahepatic portal branches from the right umbilican vein...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/01.rct.0000165905.06031.b0
更新日期:2005-07-01 00:00:00
abstract::We evaluated the feasibility of angiographic computed tomography (ACT) for diagnostic imaging in a patient with degenerative lumbar spine disease. ACT provides a volume data set out of a rotational acquisition with a c-arm-mounted flat-panel detector. Using this technique, radiographic myelography and myelographic com...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/01.rct.0000228152.73528.54
更新日期:2006-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to investigate the noninvasive quantification of coronary artery stenosis using cardiac software packages and vessel phantoms with known stenosis severity. MATERIALS AND METHODS:Four different sizes of vessel phantoms were filled with contrast agent and scanned on a 64-slice multi...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e3181888363
更新日期:2009-07-01 00:00:00
abstract::Aneurysms arising from the extracranial carotid arteries are uncommon lesions. Clinically, they may present as lateral masses in the superior cervical area, as medial masses in the tonsillar fossa or parapharyngeal region, or as a mass palpable in both areas. Tenderness or pain may or may not be present. Pulsation is ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:
更新日期:1986-05-01 00:00:00
abstract::We have previously shown that 5 mm axial T1-weighted images following Gd-diethylenetriamine pentaacetic acid (DTPA) administration were sufficient as a screening examination of the internal auditory canal (IAC) and cerebellopontine angle cistern in 80% of cases with sensorineural hearing loss. In the remaining 20% of ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-199111000-00004
更新日期:1991-11-01 00:00:00
abstract::We present a case series of the MR findings of destructive tears of the Achilles tendon secondary to overlying soft tissue ulcerations. ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-200011000-00016
更新日期:2000-11-01 00:00:00
abstract:OBJECTIVE:To assess the degree of extra scanning beyond the prescribed anatomic boundaries for thoracic and body computed tomographic (CT) scans and to identify associated factors. METHODS:For 442 consecutive chest, abdomen, and/or pelvis CT examinations, the length of extra scanning beyond the prescribed anatomic bou...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e3181f5a652
更新日期:2011-01-01 00:00:00
abstract::The typical MRI features of hydatid cyst in soft tissue/muscle are presented and discussed. ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-199903000-00031
更新日期:1999-03-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to compare image quality for abdominal computed tomographic (CT) images acquired at 200 and 50 mA s and reconstructed with image-based iterative reconstruction. MATERIALS AND METHODS:In this institutional review board-approved prospective study, 22 patients (mean [SD] age, 64....
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e3182a17629
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:The purpose of our study was to test dynamic helical CT (hCT) in the evaluation of breast tumors. METHOD:Thirty-six patients with 39 suspected lesions underwent breast hCT before and 1, 3, and 8 min after intravenous contrast medium administration. A marked enhancement (> or = 100%) at 1 or 3 min without incre...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-199805000-00010
更新日期:1998-05-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to study the role of multidetector computed tomography (MDCT) in the analysis of foreign objects found within or on the royal Egyptian mummies. METHODS:We studied MDCT images of 15 royal Egyptian mummies (1493-1156 BC) for the presence of foreign objects. We studied each found...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e3182ab2221
更新日期:2014-03-01 00:00:00
abstract:OBJECTIVE:Dysarthria and tongue swelling may be seen with hypoglossal nerve palsy, and on cross-sectional imaging studies, tongue denervation can be misinterpreted as a primary base-of-tongue mass. Understanding radiological patterns of tongue denervation is important to prevent misinterpretation. Close evaluation of t...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e318268ec18
更新日期:2012-11-01 00:00:00
abstract:PURPOSE:This study was designed to examine the use of quantitative magnetization transfer imaging (MTI) in naturally occurring globoid cell leukodystrophy (GLD) in the Cairn terrier. METHOD:A model of GLD was established via a breeding colony, and a total of seven animals were studied with MTI, including two dogs with...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-200003000-00025
更新日期:2000-03-01 00:00:00
abstract::This report describes the imaging findings of the first reported case of a bronchobiliary fistula that developed as a complication of liver transplantation. The diagnosis was confirmed by the aspiration of bile from the bronchus. ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/01.rct.0000131583.52386.cf
更新日期:2004-09-01 00:00:00
abstract::A new 6 mm collimator for the EMI CT5000/5005 scanner is described. It consists of a narrower tube side and detector side collimator that can be set up in less than 5 min. The applications are primarily for the orbit and parasellar area. Future applications with the aid of new software include coronal reconstruction. ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-197807000-00029
更新日期:1978-07-01 00:00:00
abstract:OBJECTIVE:To determine if gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) cholangiography can detect and localize bile duct leaks in postcholecystectomy patients. MATERIAL AND METHODS:Four blinded independent radiologists performed a retrospective review of 16...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0000000000000083
更新日期:2014-07-01 00:00:00
abstract:OBJECTIVE:To determine the incremental detection rate of clinically significant prostate cancer (csPCa) provided by sequential cores during in-bore magnetic resonance imaging (MRI)-guided prostate biopsies. METHODS:Single-center, retrospective interpretation of prospectively acquired data in men without previous diagn...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0000000000001115
更新日期:2020-12-02 00:00:00
abstract:PURPOSE:The purpose of this work was to determine the accuracy of predicting arterial enhancement from peripheral versus central venous test bolus injections at CT angiography (CTA). METHOD:In 40 patients with abdominal aortic aneurysms, aortoiliac enhancement profiles were predicted by mathematical deconvolution of t...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-200103000-00024
更新日期:2001-03-01 00:00:00
abstract::A case of a recurrent submandibular pleomorphic adenoma with metastasis in which both the primary tumor and metastasis were histologically benign is reported and the literature reviewed. ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章,评审
doi:10.1097/00004728-198711000-00043
更新日期:1987-11-01 00:00:00
abstract:OBJECTIVES:Advances in computed tomography technology may permit the evaluation of coronary disease, aortic dissection, and pulmonary embolism with a single contrast bolus and breath hold. We sought to determine whether 64-slice computed tomography angiography (CTA) allows for simultaneous visualization of the coronary...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e31817c12b1
更新日期:2009-03-01 00:00:00
abstract:BACKGROUND:Neonatal hypoxic-ischemic encephalopathy (HIE) is associated with dysfunctional cerebral autoregulation. Resistive index (RI) measured in the anterior cerebral artery on transfontanellar head ultrasound is a noninvasive measure of blood flow and may indicate autoregulation dysfunction. We tested whether RI w...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0000000000001069
更新日期:2020-09-01 00:00:00
abstract::Two patients with bone sarcomas were found to have pancreatic masses on routine follow-up CT. Although pancreatic metastasis most often occurs in a setting of widely disseminated disease, it may occur as an isolated finding, most often asymptomatic. It may also be responsible for clinical pancreatitis. Both of these p...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-198509000-00008
更新日期:1985-09-01 00:00:00
abstract::The demonstration by computed tomography (CT) of enlarged nodes and/or masses in lymphoma patients has been interpreted as indicating that active disease is present. Four cases are presented in which either biopsy or laparotomy of a CT-detected mass after therapy revealed fibrous tissue with no evidence of viable neop...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-198208000-00025
更新日期:1982-08-01 00:00:00
abstract::Idiopathic muscular hypertrophy of the esophagus is a rare, benign esophageal disease, characterized by hyperplasia of all layers of the wall and, in particular, muscle layers. The authors describe the CT findings and review the relevant literature. ...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-198811000-00026
更新日期:1988-11-01 00:00:00
abstract:OBJECTIVE:Our goal was to analyze the sources of nonuniform image intensity of two surface coil configurations used on a General Electric 1.5 T Signa scanner and to correct the major source. MATERIALS AND METHODS:Correction of receive coil nonuniform sensitivity is achieved using division by images of a uniform phanto...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/00004728-199411000-00033
更新日期:1994-11-01 00:00:00
abstract:OBJECTIVE:This study aimed to determine optimal strength of sinogram-affirmed iterative reconstruction (SAFIRE) and to evaluate image quality (IQ) of low-dose chest computed tomography (LDCT) using SAFIRE compared with iterative reconstruction in image space (IRIS) and filtered back projection (FBP). METHODS:Thirty pa...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:10.1097/RCT.0b013e31828f4dae
更新日期:2013-07-01 00:00:00
abstract::Calcifications of renal masses are common. They are usually dense, partial, small, punctate, and linear opacities. Diffuse calcification is an extremely rare feature of renal masses. Generally, calcified renal cell carcinomas are hypovascular, with calcifications in the interstitium, and they also contain fibrotic cap...
journal_title:Journal of computer assisted tomography
pub_type: 杂志文章
doi:
更新日期:1992-07-01 00:00:00