Craniofacial melorheostosis.

Abstract:

:Melorheostosis is a rare benign disease of cortical bone most frequently presenting as peripheral hyperostosis with a characteristic "melting wax" appearance on conventional radiographs. The disease most frequently affects the appendicular skeleton and is seen only rarely in the craniofacial bones. We discuss a case of melorheostosis in the nasal cavity and skull base with an atypical radiographic appearance and suggest findings that may differentiate craniofacial melorheostosis from more common entities in this region.

journal_name

J Comput Assist Tomogr

authors

McDermott M,Branstetter BF 4th,Seethala RR

doi

10.1097/RCT.0b013e3181572998

subject

Has Abstract

pub_date

2008-09-01 00:00:00

pages

825-7

issue

5

eissn

0363-8715

issn

1532-3145

pii

00004728-200809000-00028

journal_volume

32

pub_type

杂志文章
  • Compressive sensing-based interior tomography: preliminary clinical application.

    abstract::Compressive sensing (CS)-based interior tomography is a state-of-the-art method for accurate image reconstruction from only locally truncated projections. Here, we report our preliminary interior tomography results reconstructed from raw projections of a patient acquired on a GE Discovery CT750 HD scanner. This is the...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318231c578

    authors: Yu H,Wang G,Hsieh J,Entrikin DW,Ellis S,Liu B,Carr JJ

    更新日期:2011-11-01 00:00:00

  • Quantification of vasa vasorum density in multi-slice computed tomographic coronary angiograms: role of computed tomographic image voxel size.

    abstract:OBJECTIVE:This study is motivated by the possibility of using computed tomography (CT) to detect early coronary atherosclerosis by the increased CT values within the arterial wall resulting from vasa vasorum proliferation. METHODS:Coronary arteries (n = 5) with early atherosclerotic changes were injected with Microfil...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181bb0d32

    authors: Moritz R,Eaker DR,Langheinrich AC,Jorgensen SM,Bohle RM,Ritman EL

    更新日期:2010-03-01 00:00:00

  • Comparison of 320-row computed tomography coronary angiography with conventional angiography for the assessment of coronary artery disease with different atherosclerotic plaque characteristics.

    abstract:OBJECTIVE:The objective of this study was to compare the accuracy of 320-row computed tomography angiography (CTA) with conventional coronary angiography. METHODS:Two hundred seventy-four patients with coronary artery disease who received both invasive coronary angiography and 320-row CTA were included. Stenosis of 50...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31826ab24a

    authors: Yang QH,Chen YJ,Liu QQ,Dong M,Wen L,Song X,Lv YJ,Gong YZ,Li XQ

    更新日期:2012-11-01 00:00:00

  • Anomaly of the portal vein with total ramification of the intrahepatic portal branches from the right umbilical portion: CT features.

    abstract:PURPOSE:To describe CT findings of portal vein anomaly with total ramification of the intrahepatic portal branches from the right umbilical vein. METHODS:Retrospective analysis was performed in 6 patients with portal vein anomaly with total ramification of the intrahepatic portal branches from the right umbilican vein...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000165905.06031.b0

    authors: Yang DM,Kim H,Kang JH,Park CH,Chang SK,Jin W,Kim HS

    更新日期:2005-07-01 00:00:00

  • Angiographic computed tomography is comparable to multislice computed tomography in lumbar myelographic imaging.

    abstract::We evaluated the feasibility of angiographic computed tomography (ACT) for diagnostic imaging in a patient with degenerative lumbar spine disease. ACT provides a volume data set out of a rotational acquisition with a c-arm-mounted flat-panel detector. Using this technique, radiographic myelography and myelographic com...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000228152.73528.54

    authors: Buhk JH,Elolf E,Knauth M

    更新日期:2006-09-01 00:00:00

  • Accuracy of noninvasive coronary stenosis quantification of different commercially available dedicated software packages.

    abstract:PURPOSE:The purpose of this study was to investigate the noninvasive quantification of coronary artery stenosis using cardiac software packages and vessel phantoms with known stenosis severity. MATERIALS AND METHODS:Four different sizes of vessel phantoms were filled with contrast agent and scanned on a 64-slice multi...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181888363

    authors: Dikkers R,Willems TP,de Jonge GJ,Marquering HA,Greuter MJ,van Ooijen PM,van der Weide MC,Oudkerk M

    更新日期:2009-07-01 00:00:00

  • CT demonstration of extracranial carotid artery aneurysms.

    abstract::Aneurysms arising from the extracranial carotid arteries are uncommon lesions. Clinically, they may present as lateral masses in the superior cervical area, as medial masses in the tonsillar fossa or parapharyngeal region, or as a mass palpable in both areas. Tenderness or pain may or may not be present. Pulsation is ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Duvall ER,Gupta KL,Vitek JJ,Stanley RJ,Luna RF,Howieson J

    更新日期:1986-05-01 00:00:00

  • Screening protocol for MR imaging of the internal auditory canal.

    abstract::We have previously shown that 5 mm axial T1-weighted images following Gd-diethylenetriamine pentaacetic acid (DTPA) administration were sufficient as a screening examination of the internal auditory canal (IAC) and cerebellopontine angle cistern in 80% of cases with sensorineural hearing loss. In the remaining 20% of ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199111000-00004

    authors: Litt AW,Mirsky P,Berson BD,Kricheff II

    更新日期:1991-11-01 00:00:00

  • MRI of destructive achilles tendon rupture associated with skin ulceration.

    abstract::We present a case series of the MR findings of destructive tears of the Achilles tendon secondary to overlying soft tissue ulcerations. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200011000-00016

    authors: Kihiczak D,Colletti PM,Terk MR

    更新日期:2000-11-01 00:00:00

  • Extra Z-axis coverage at CT imaging resulting in excess radiation dose: frequency, degree, and contributory factors.

    abstract:OBJECTIVE:To assess the degree of extra scanning beyond the prescribed anatomic boundaries for thoracic and body computed tomographic (CT) scans and to identify associated factors. METHODS:For 442 consecutive chest, abdomen, and/or pelvis CT examinations, the length of extra scanning beyond the prescribed anatomic bou...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3181f5a652

    authors: Liao EA,Quint LE,Goodsitt MM,Francis IR,Khalatbari S,Myles JD

    更新日期:2011-01-01 00:00:00

  • Magnetic resonance imaging of hydatid cyst in skeletal muscle.

    abstract::The typical MRI features of hydatid cyst in soft tissue/muscle are presented and discussed. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199903000-00031

    authors: Salai M,Apter S,Dudkiewicz I,Chechik A,Itzchak Y

    更新日期:1999-03-01 00:00:00

  • Preliminary results: prospective clinical study to assess image-based iterative reconstruction for abdominal computed tomography acquired at 2 radiation dose levels.

    abstract:OBJECTIVE:The objective of this study was to compare image quality for abdominal computed tomographic (CT) images acquired at 200 and 50 mA s and reconstructed with image-based iterative reconstruction. MATERIALS AND METHODS:In this institutional review board-approved prospective study, 22 patients (mean [SD] age, 64....

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3182a17629

    authors: Pourjabbar S,Singh S,Singh AK,Johnston RP,Shenoy-Bhangle AS,Do S,Padole A,Blake MA,Persson A,Kalra MK

    更新日期:2014-01-01 00:00:00

  • Dynamic helical CT of breast tumors.

    abstract:PURPOSE:The purpose of our study was to test dynamic helical CT (hCT) in the evaluation of breast tumors. METHOD:Thirty-six patients with 39 suspected lesions underwent breast hCT before and 1, 3, and 8 min after intravenous contrast medium administration. A marked enhancement (> or = 100%) at 1 or 3 min without incre...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199805000-00010

    authors: Sardanelli F,Calabrese M,Zandrino F,Melani E,Parodi R,Imperiale A,Massa T,Parodi G,Canavese G

    更新日期:1998-05-01 00:00:00

  • Multidetector computed tomographic study of amulets, jewelry, and other foreign objects in royal Egyptian mummies dated from the 18th to 20th dynasties.

    abstract:OBJECTIVE:The objective of this study was to study the role of multidetector computed tomography (MDCT) in the analysis of foreign objects found within or on the royal Egyptian mummies. METHODS:We studied MDCT images of 15 royal Egyptian mummies (1493-1156 BC) for the presence of foreign objects. We studied each found...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e3182ab2221

    authors: Saleem SN,Hawass Z

    更新日期:2014-03-01 00:00:00

  • Hypoglossal nerve palsy missed and misinterpreted: the hidden skull base.

    abstract:OBJECTIVE:Dysarthria and tongue swelling may be seen with hypoglossal nerve palsy, and on cross-sectional imaging studies, tongue denervation can be misinterpreted as a primary base-of-tongue mass. Understanding radiological patterns of tongue denervation is important to prevent misinterpretation. Close evaluation of t...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e318268ec18

    authors: Learned KO,Thaler ER,O'Malley BW Jr,Grady MS,Loevner LA

    更新日期:2012-11-01 00:00:00

  • Investigating demyelination in the brain in a canine model of globoid cell leukodystrophy (Krabbe disease) using magnetization transfer contrast: preliminary results.

    abstract:PURPOSE:This study was designed to examine the use of quantitative magnetization transfer imaging (MTI) in naturally occurring globoid cell leukodystrophy (GLD) in the Cairn terrier. METHOD:A model of GLD was established via a breeding colony, and a total of seven animals were studied with MTI, including two dogs with...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200003000-00025

    authors: McGowan JC,Haskins M,Wenger DA,Vite C

    更新日期:2000-03-01 00:00:00

  • Bronchobiliary fistula after liver transplantation.

    abstract::This report describes the imaging findings of the first reported case of a bronchobiliary fistula that developed as a complication of liver transplantation. The diagnosis was confirmed by the aspiration of bile from the bronchus. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/01.rct.0000131583.52386.cf

    authors: Yeatman CF,Fisher RA,Carucci LR,Halvorsen RA

    更新日期:2004-09-01 00:00:00

  • A 6 mm collimator system for the EMI CT5000/5005 whole body scanner.

    abstract::A new 6 mm collimator for the EMI CT5000/5005 scanner is described. It consists of a narrower tube side and detector side collimator that can be set up in less than 5 min. The applications are primarily for the orbit and parasellar area. Future applications with the aid of new software include coronal reconstruction. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-197807000-00029

    authors: Baldwin GN,Sorenson JA,Wolfley D,Canestrini R,Pritchard MJ

    更新日期:1978-07-01 00:00:00

  • Detection and localization of bile duct leaks after cholecystectomy using Gd-EOB-DTPA-enhanced MR cholangiography: retrospective study of 16 patients.

    abstract:OBJECTIVE:To determine if gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance (MR) cholangiography can detect and localize bile duct leaks in postcholecystectomy patients. MATERIAL AND METHODS:Four blinded independent radiologists performed a retrospective review of 16...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000000083

    authors: Ratcliffe GE,Kirkpatrick ID,Anik Sahni V,Greenberg HM,Henderson B,Radulovic D,Mottola JC

    更新日期:2014-07-01 00:00:00

  • Impact of the Number of Cores on the Prostate Cancer Detection Rate in Men Undergoing in-Bore Magnetic Resonance Imaging-Guided Targeted Biopsies.

    abstract:OBJECTIVE:To determine the incremental detection rate of clinically significant prostate cancer (csPCa) provided by sequential cores during in-bore magnetic resonance imaging (MRI)-guided prostate biopsies. METHODS:Single-center, retrospective interpretation of prospectively acquired data in men without previous diagn...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000001115

    authors: Subramanian N,Recchimuzzi DZ,Xi Y,Diaz de Leon A,Chen H,Xie D,Goldberg K,Rofsky NM,Pedrosa I,Costa DN

    更新日期:2020-12-02 00:00:00

  • Accuracy of predicting and controlling time-dependent aortic enhancement from a test bolus injection.

    abstract:PURPOSE:The purpose of this work was to determine the accuracy of predicting arterial enhancement from peripheral versus central venous test bolus injections at CT angiography (CTA). METHOD:In 40 patients with abdominal aortic aneurysms, aortoiliac enhancement profiles were predicted by mathematical deconvolution of t...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-200103000-00024

    authors: Hittmair K,Fleischmann D

    更新日期:2001-03-01 00:00:00

  • CT findings in recurrent submandibular pleomorphic adenoma with metastasis.

    abstract::A case of a recurrent submandibular pleomorphic adenoma with metastasis in which both the primary tumor and metastasis were histologically benign is reported and the literature reviewed. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章,评审

    doi:10.1097/00004728-198711000-00043

    authors: Guglielmo FF,Rao VM,Prestipino AJ,Steiner RM

    更新日期:1987-11-01 00:00:00

  • A comprehensive electrocardiogram-gated 64-slice multidetector computed tomography imaging protocol to visualize the coronary arteries, thoracic aorta, and pulmonary vasculature in a single breath hold.

    abstract:OBJECTIVES:Advances in computed tomography technology may permit the evaluation of coronary disease, aortic dissection, and pulmonary embolism with a single contrast bolus and breath hold. We sought to determine whether 64-slice computed tomography angiography (CTA) allows for simultaneous visualization of the coronary...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31817c12b1

    authors: Shapiro MD,Dodd JD,Kalva S,Wittram C,Hsu J,Nasir K,Liu B,Nagurney JT,Kalra MK,Nichols JH,Cury RC,Abbara S,Tawakol A,Brady TJ,Hoffmann U

    更新日期:2009-03-01 00:00:00

  • Head Ultrasound Resistive Indices Are Associated With Brain Injury on Diffusion Tensor Imaging Magnetic Resonance Imaging in Neonates With Hypoxic-Ischemic Encephalopathy.

    abstract:BACKGROUND:Neonatal hypoxic-ischemic encephalopathy (HIE) is associated with dysfunctional cerebral autoregulation. Resistive index (RI) measured in the anterior cerebral artery on transfontanellar head ultrasound is a noninvasive measure of blood flow and may indicate autoregulation dysfunction. We tested whether RI w...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0000000000001069

    authors: Snyder EJ,Perin J,Chavez-Valdez R,Northington FJ,Lee JK,Tekes A

    更新日期:2020-09-01 00:00:00

  • Pancreatic metastases in bone sarcomas: CT demonstration.

    abstract::Two patients with bone sarcomas were found to have pancreatic masses on routine follow-up CT. Although pancreatic metastasis most often occurs in a setting of widely disseminated disease, it may occur as an isolated finding, most often asymptomatic. It may also be responsible for clinical pancreatitis. Both of these p...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198509000-00008

    authors: Rubin E,Dunham WK,Stanley RJ

    更新日期:1985-09-01 00:00:00

  • Post-therapy CT-detected mass in lymphoma patients: is it viable tissue?

    abstract::The demonstration by computed tomography (CT) of enlarged nodes and/or masses in lymphoma patients has been interpreted as indicating that active disease is present. Four cases are presented in which either biopsy or laparotomy of a CT-detected mass after therapy revealed fibrous tissue with no evidence of viable neop...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198208000-00025

    authors: Lewis E,Bernardino ME,Salvador PG,Cabanillas FF,Barnes PA,Thomas JL

    更新日期:1982-08-01 00:00:00

  • Idiopathic muscular hypertrophy of the esophagus: CT features.

    abstract::Idiopathic muscular hypertrophy of the esophagus is a rare, benign esophageal disease, characterized by hyperplasia of all layers of the wall and, in particular, muscle layers. The authors describe the CT findings and review the relevant literature. ...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-198811000-00026

    authors: Agostini S,Grimaud JC,Salducci J,Clement JP

    更新日期:1988-11-01 00:00:00

  • Correction of nonuniformity in images of the spine and optic nerve from fixed receive-only surface coils at 1.5 T.

    abstract:OBJECTIVE:Our goal was to analyze the sources of nonuniform image intensity of two surface coil configurations used on a General Electric 1.5 T Signa scanner and to correct the major source. MATERIALS AND METHODS:Correction of receive coil nonuniform sensitivity is achieved using division by images of a uniform phanto...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/00004728-199411000-00033

    authors: Tofts PS,Barker GJ,Simmons A,MacManus DG,Thorpe J,Gass A,Miller DH

    更新日期:1994-11-01 00:00:00

  • Low-dose chest computed tomography with sinogram-affirmed iterative reconstruction, iterative reconstruction in image space, and filtered back projection: studies on image quality.

    abstract:OBJECTIVE:This study aimed to determine optimal strength of sinogram-affirmed iterative reconstruction (SAFIRE) and to evaluate image quality (IQ) of low-dose chest computed tomography (LDCT) using SAFIRE compared with iterative reconstruction in image space (IRIS) and filtered back projection (FBP). METHODS:Thirty pa...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:10.1097/RCT.0b013e31828f4dae

    authors: Hwang HJ,Seo JB,Lee HJ,Lee SM,Kim EY,Oh SY,Kim JE

    更新日期:2013-07-01 00:00:00

  • Diffusely calcified renal cell carcinoma: CT features.

    abstract::Calcifications of renal masses are common. They are usually dense, partial, small, punctate, and linear opacities. Diffuse calcification is an extremely rare feature of renal masses. Generally, calcified renal cell carcinomas are hypovascular, with calcifications in the interstitium, and they also contain fibrotic cap...

    journal_title:Journal of computer assisted tomography

    pub_type: 杂志文章

    doi:

    authors: Onitsuka H,Murakami J,Naito S,Souda R,Shioyama Y,Honda H,Araki A,Torii Y,Masuda K

    更新日期:1992-07-01 00:00:00