Assessment and reproducibility of aortic atherosclerosis magnetic resonance imaging: impact of 3-Tesla field strength and parallel imaging.

Abstract:

OBJECTIVES:To investigate image quality and interstudy reproducibility of aortic atherosclerosis imaging at 1.5 T, and to explore the impact of parallel imaging techniques at 3 T. MATERIALS AND METHODS:Institutional review board approval and informed consent were obtained. Thirty-two subjects (20 normal, 12 patients with impaired cardiac function) underwent 4 black-blood T2-weighted imaging studies of the abdominal aorta: 2 conventional studies at 1.5 T, a conventional study at 3 T, and an accelerated 3-T study with parallel imaging (SENSE). Contrast-to-noise ratio and image quality score (1-5 scale, 5 = highest quality) were determined for each study. Studies were analyzed for mean wall thickness and area plaque burden as endpoints for aortic atherosclerosis. Bland-Altman analyses were performed to determine interstudy reproducibility between imaging methods. Wilcoxon signed-rank tests were used to identify significant differences between methods (P < 0.05). RESULTS:Image quality scores were comparable between 1.5 T and 3 T with SENSE (4.0 +/- 0.6 vs. 4.2 +/- 0.6, P = 0.21). Bland-Altman reproducibility for mean wall thickness was -0.03 mm +/- 0.15 (1.5 T vs. 1.5 T), 0.01 mm +/- 0.17 (1.5 T vs. 3 T without SENSE), and -0.01 mm +/- 0.18 (1.5 T vs. 3 T with SENSE), P = 0.83. Detection of the presence or absence of plaque was comparable. Bland-Altman reproducibility for area plaque burden was -0.02% +/- 0.32% (1.5 T vs. 1.5 T), 0.06% +/- 0.41% (1.5 T vs. 3 T without SENSE), and 0.11% +/- 0.33% (1.5 T vs. 3 T with SENSE), P = 0.41. CONCLUSION:Black-blood MR imaging of aortic atherosclerosis is very reproducible. Parallel imaging at 3 T permits shorter scan time compared with conventional 1.5-T imaging with comparable measures of atherosclerosis extent.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Maroules CD,McColl R,Khera A,Peshock RM

doi

10.1097/RLI.0b013e318181538a

subject

Has Abstract

pub_date

2008-09-01 00:00:00

pages

656-62

issue

9

eissn

0020-9996

issn

1536-0210

pii

00004424-200809000-00009

journal_volume

43

pub_type

杂志文章
  • Influence of paramagnetic ions and pH on proton NMR relaxation of biologic fluids.

    abstract::The extent to which various concentrations of the paramagnetic metal ions [gadolinium (III), manganese (II), chromium (III), iron (III), nickel (II), copper (II), and cobalt (II)] affect proton magnetic relaxation times of distilled water, 4% human serum albumin (HSA), and dog plasma was studied in vitro. The pH of wa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00009

    authors: Barnhart JL,Berk RN

    更新日期:1986-02-01 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • BR1: a new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles.

    abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199508000-00001

    authors: Schneider M,Arditi M,Barrau MB,Brochot J,Broillet A,Ventrone R,Yan F

    更新日期:1995-08-01 00:00:00

  • MR characterization of mild hyperthermia-induced gadodiamide release from thermosensitive liposomes in solid tumors.

    abstract:OBJECTIVES:Thermal dose in tumor tissue is a key factor for regional hyperthermia (HT) combined with chemotherapy and for drug delivery using thermosensitive liposomes (TSL). It influences therapy outcome, affects the accumulation of liposomes, and triggers the content release from TSL in the target tissue. For the dev...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31818768cd

    authors: Peller M,Schwerdt A,Hossann M,Reinl HM,Wang T,Sourbron S,Ogris M,Lindner LH

    更新日期:2008-12-01 00:00:00

  • Structured Reporting of Rectal Magnetic Resonance Imaging in Suspected Primary Rectal Cancer: Potential Benefits for Surgical Planning and Interdisciplinary Communication.

    abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000336

    authors: Nörenberg D,Sommer WH,Thasler W,DʼHaese J,Rentsch M,Kolben T,Schreyer A,Rist C,Reiser M,Armbruster M

    更新日期:2017-04-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the renal arteries. Original investigation.

    abstract:RATIONALE AND OBJECTIVES:The authors determine the value of contrast-enhanced, three-dimensional (3D) magnetic resonance angiography (MRA) in the assessment of the renal arteries in comparison with conventional arteriography (CA). METHODS:One hundred three patients (71 m, 32 f) were evaluated with both CA and 3D MRA. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199809000-00021

    authors: Hany TF,Leung DA,Pfammatter T,Debatin JF

    更新日期:1998-09-01 00:00:00

  • Regional ejection fractions in patients with patent and thrombosed grafts after coronary artery vein bypass surgery.

    abstract::Twenty-six patients who had received 43 grafts were studied before and after coronary artery vein bypass surgery. Cine ventriculograms taken in the right anterior oblique projection were analyzed and regional ejection fractions calculated. Single and multiple grafts were considered separately as were thrombosed and pa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197705000-00001

    authors: Martin EC,Wixson D,Baltaxe HA

    更新日期:1977-05-01 00:00:00

  • Choice of contrast material for four-hour delayed contrast-enhanced computed tomography of the liver.

    abstract::Four-hour delayed contrast-enhanced computed tomography (DCECT) shows promise for improved detection of focal liver lesions. No previous studies have examined the use of nonionic contrast materials for DCECT. The authors undertook a case-controlled study in monkeys to define the relative efficacies of iopamidol and di...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198910000-00010

    authors: Feuerstein IM,Girton ME

    更新日期:1989-10-01 00:00:00

  • Delayed Gadolinium Leakage in Ocular Structures: A Potential Marker for Age- and Vascular Risk Factor-Related Small Vessel Disease?

    abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000757

    authors: Galmiche C,Moal B,Marnat G,Sagnier S,Schweitzer C,Dousset V,Sibon I,Tourdias T

    更新日期:2021-01-19 00:00:00

  • A preliminary study of MRI quantification of simulated calcified pulmonary nodules.

    abstract::The potential of magnetic resonance imaging (MRI) quantification of calcium for the evaluation of pulmonary nodules was investigated in simulated nodules. Calcium salts do not contain mobile protons and thus have no signal on MR proton images. To determine whether the absence of signal from partially calcified nodules...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198711000-00001

    authors: Gamsu G,de Geer G,Cann C,Müller N,Brito A

    更新日期:1987-11-01 00:00:00

  • Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.

    abstract:PURPOSE:The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tom...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000458

    authors: Frellesen C,Azadegan M,Martin SS,Otani K,DʼAngelo T,Booz C,Eichler K,Panahi B,Kaup M,Bauer RW,Vogl TJ,Wichmann JL

    更新日期:2018-07-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • Biodistribution of radiolabeled, formulated gadopentetate, gadoteridol, gadoterate, and gadodiamide in mice and rats.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199506000-00008

    authors: Tweedle MF,Wedeking P,Kumar K

    更新日期:1995-06-01 00:00:00

  • Percutaneous radiofrequency ablation of hepatic colorectal metastases: technique, indications, results, and new promises.

    abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-200411000-00007

    authors: Lencioni R,Crocetti L,Cioni D,Della Pina C,Bartolozzi C

    更新日期:2004-11-01 00:00:00

  • Quantification of Aortic Stiffness by Ultrasound Time-Harmonic Elastography: The Effect of Intravascular Pressure on Elasticity Measures in a Porcine Model.

    abstract:OBJECTIVES:The aim of this study was to investigate blood pressure dependency of ultrasound time-harmonic elastography (THE) for quantification of aortic stiffness. MATERIALS AND METHODS:Thoracoabdominal aortas were surgically removed from 9 healthy domestic pigs and prepared for elastographic experiments. All vessels...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000618

    authors: Schaafs LA,Tzschätzsch H,Steffen IG,Braun J,Hamm B,Sack I,Elgeti T

    更新日期:2020-03-01 00:00:00

  • High resolution sonography of the menisci of the knee.

    abstract::High-resolution real-time ultrasonography (5, 7.5, and 10 MHz) was used to examine the menisci of the knee in ten normal volunteers and in ten patients with knee injuries. The posterior horns of the medial and lateral menisci were easily demonstrated. Normal anatomy and pathologic changes could be imaged in the menisc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00008

    authors: Selby B,Richardson ML,Montana MA,Teitz CC,Larson RV,Mack LA

    更新日期:1986-04-01 00:00:00

  • The effects of radiographic contrast media on myocardial contractility and coronary resistance: osmolality, ionic concentration, and viscosity.

    abstract::With the ongoing development of new contrast agents, questions develop concerning the cardiac effects of these drugs. We used the perfused rat heart model to investigate the effects on cardiac and coronary function of hypertonic ionic (sodium chloride) and nonionic (glucose) solutions and conventional and low osmolali...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00009

    authors: Fleetwood G,Bettmann MA,Gordon JL

    更新日期:1990-03-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.

    abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318191a334

    authors: Wintersperger BJ,Runge VM,Tweedle MF,Jackson CB,Reiser MF

    更新日期:2009-02-01 00:00:00

  • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

    abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000199292.88189.0f

    authors: Klibanov AL

    更新日期:2006-03-01 00:00:00

  • Stability of MRI paramagnetic contrast media: a proton relaxometric protocol for transmetallation assessment.

    abstract:RATIONALE AND OBJECTIVES:The suitability of paramagnetic complexes as magnetic resonance contrast agents depends on various factors such as their relaxivity, stability, selectivity, and the inertness toward transmetallation by endogenous ions. The transmetallation of a series of 18 gadolinium complexes by the Zn2+ ion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200102000-00008

    authors: Laurent S,Elst LV,Copoix F,Muller RN

    更新日期:2001-02-01 00:00:00

  • Vein graft-coated stents for endovascular occlusion of canine experimental arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199901000-00004

    authors: Schellhammer F,Wahkloo AK,Nagursky H,Schumacher M

    更新日期:1999-01-01 00:00:00

  • Fluorescent bacterial magnetic nanoparticles as bimodal contrast agents.

    abstract:OBJECTIVES:The purpose of this study was to assess whether fluorochrome-coupled bacterial magnetic nanoparticles can be used as bimodal contrast agent for both magnetic resonance imaging (MRI) and near-infrared fluorescence optical (NIRF) imaging of cultured macrophages. MATERIALS AND METHODS:Bacterial magnetic nanopa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000255832.44443.e7

    authors: Lisy MR,Hartung A,Lang C,Schüler D,Richter W,Reichenbach JR,Kaiser WA,Hilger I

    更新日期:2007-04-01 00:00:00

  • Hemodynamic effect of iodinated high-viscosity contrast medium in the rat kidney: a diffusion-weighted MRI feasibility study.

    abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200011000-00001

    authors: Laissy JP,Menegazzo D,Dumont E,Piekarski JD,Karila-Cohen P,Chillon S,Schouman-Claeys E

    更新日期:2000-11-01 00:00:00

  • Hepatocellular carcinoma: correlation between vascular endothelial growth factor level and degree of enhancement by multiphase contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200108000-00008

    authors: Kwak BK,Shim HJ,Park ES,Kim SA,Choi D,Lim HK,Park CK,Chung JW,Park JH

    更新日期:2001-08-01 00:00:00

  • Dose response to Paclitaxel-coated balloon catheters in the porcine coronary overstretch and stent implantation model.

    abstract:OBJECTIVE:There is little published information regarding the efficacy of paclitaxel-coated balloon catheters except for the iopromide-containing formulation, and less is known about the kind of toxicity at overdose. The aim of our study was to assess 2 different paclitaxel matrix formulations on angioplasty balloon ca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31820577df

    authors: Kelsch B,Scheller B,Biedermann M,Clever YP,Schaffner S,Mahnkopf D,Speck U,Cremers B

    更新日期:2011-04-01 00:00:00

  • Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS:In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199206000-00012

    authors: Sommer G,Noorbehesht B,Pelc N,Jamison R,Pinevich AJ,Newton L,Myers B

    更新日期:1992-06-01 00:00:00

  • Peripheral magnetic resonance angiography with continuous table movement in combination with high spatial and temporal resolution time-resolved MRA With a total single dose (0.1 mmol/kg) of gadobutrol at 3.0 T.

    abstract:PURPOSE:To prove the concept of peripheral continuous table movement (CTM) MR-angiography (MRA) in combination with high spatial and temporal resolution time-resolved TWIST-MRA in a single MR-examination at 3.0 T with a single dose (0.1 mmol/kg) of gadobutrol in total. MATERIALS AND METHODS:We included 22 consecutive ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c26c

    authors: Voth M,Haneder S,Huck K,Gutfleisch A,Schönberg SO,Michaely HJ

    更新日期:2009-09-01 00:00:00

  • Longitudinal Computed Tomography Monitoring of Pelvic Bones in Patients With Breast Cancer Using Automated Bone Subtraction Software.

    abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000343

    authors: Horger M,Thaiss WM,Wiesinger B,Ditt H,Fritz J,Nikolaou K,Kloth C

    更新日期:2017-02-01 00:00:00

  • Pyrroxamide, a nonionic nitroxyl spin label contrast agent for magnetic resonance imaging. Mutagenesis and cell survival.

    abstract::Pyrroxamide [N-(1-hydroxymethyl-2,3-dihydroxypropyl)-2,2,5,5-tetramethyl pyrrolidine-1-oxyl-3-carboxyamide] is a newly tested nonionic monomeric nitroxyl compound with demonstrated effectiveness for MRI contrast enhancement at doses as low as 10(-3) M. Pyrroxamide and its hydroxylamine metabolic derivative were tested...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00013

    authors: Gordon DG,Brasch RC,Ogan MD,Deen D

    更新日期:1988-08-01 00:00:00