99mTc-sestamibi imaging and bone marrow karyotyping in the assessment of multiple myeloma and MGUS.

Abstract:

AIM:The first pathogenetic step in multiple myeloma is the emergence of a limited number of clonal plasma cells, clinically known as monoclonal gammopathy of undetermined significance (MGUS). Patients with MGUS do not have symptoms or end-organ damage but they do have a 1% annual risk of progression to multiple myeloma or related malignant disorders. With progression of MGUS to multiple myeloma, complex genetic events occur in the neoplastic plasma cell. Karyotyping and fluorescence in-situ hybridization (FISH) were shown to be of prognostic value in patients with multiple myeloma. Tc-sestamibi imaging reflects myeloma disease activity in bone marrow with very high sensitivity and specificity predicting disease evolution. This study was undertaken to evaluate the role of Tc-sestamibi imaging and cytogenetic analysis in prognosis prediction of MGUS and multiple myeloma. METHODS:We enrolled 30 consecutive patients with a confirmed diagnosis of multiple myeloma or MGUS. Bone marrow biopsy and biochemical staging according to the International Staging System (ISS) were performed in all cases. Karyotype analysis and FISH were performed in 11 of 12 patients with MGUS and in 17 of 18 patients with multiple myeloma having adequate metaphases. RESULTS:The karyotype was abnormal in four of 11 MGUS and in six of 17 multiple myeloma. Abnormalities of chromosome 13 were present in one case of MGUS and in six cases of multiple myeloma whereas the involvement of immunoglobulin was observed in one case of multiple myeloma. An abnormal FISH panel was found in four MGUS and nine multiple myeloma patients. All patients with MGUS showed a normal MIBI scan (score 0). Among patients with multiple myeloma only three, all with ISS stage I, showed a normal scan while a positive scan was obtained in others (score range, 1-7). The MIBI uptake was strongly related to the bone marrow plasma cell infiltration and to cytogenetic abnormalities. Particularly, a MIBI uptake score above 5 identified patients with poor prognosis encompassing all stage III multiple myeloma and three of seven stage II multiple myeloma. On the other hand all stage I and II patients having a MIBI score less than 5 showed a good prognosis. CONCLUSION:Both cytogenetic analysis and a MIBI scan add no relevant prognostic information to the ISS in patients with stage I and III multiple myeloma. The MIBI scan was of prognostic value in stage II multiple myeloma patients. Additionally, MIBI imaging may be useful to guide bone marrow biopsy in order to obtain adequate samples for cytogenetic analysis.

journal_name

Nucl Med Commun

authors

Giovanella L,Taborelli M,Ceriani L,Zucca E,Cavalli F,Delaloye AB

doi

10.1097/MNM.0b013e3282f5e5df

subject

Has Abstract

pub_date

2008-06-01 00:00:00

pages

535-41

issue

6

eissn

0143-3636

issn

1473-5628

pii

00006231-200806000-00005

journal_volume

29

pub_type

杂志文章
  • Optimization of the parameters of a method for computer-aided detection of perfusion deficiencies in brain images.

    abstract:OBJECTIVE:Simulated data from the recent Institute of Physics and Engineering in Medicine audit of quantitative cerebral perfusion were used to optimize the parameters of eigenimage analysis, a method for computer-aided detection. METHODS:Twenty normal images provided by the audit were registered to the International ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e32832cc273

    authors: Houston AS,Fleming JS,Ward T,Hoffmann SM

    更新日期:2009-09-01 00:00:00

  • Cell uptake and tissue distribution of radioiodine labelled D-luciferin: implications for luciferase based gene imaging.

    abstract::Optical luciferase gene imaging is emerging as a method to monitor gene expression in small animals. However, there is concern over how regional availability of exogenously administered substrate may affect photon emission. We thus synthesized [125I]iodo-D-luciferin, which demonstrated substrate characteristics for fi...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200309000-00009

    authors: Lee KH,Byun SS,Paik JY,Lee SY,Song SH,Choe YS,Kim BT

    更新日期:2003-09-01 00:00:00

  • Interpretation, accuracy and management implications of FDG PET/CT in cutaneous malignant melanoma.

    abstract:PURPOSE:To investigate the accuracy of different interpretative approaches and to evaluate the management implications of fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) in cutaneous malignant melanoma. METHODS:We retrospectively identified 60 consecutive patients who underwent 76 PET/...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e3280708ecf

    authors: Falk MS,Truitt AK,Coakley FV,Kashani-Sabet M,Hawkins RA,Franc B

    更新日期:2007-04-01 00:00:00

  • Sentinel node localization in patients with non-palpable breast cancer.

    abstract::The aim of this study was to demonstrate that radionuclide sentinel node detection can be applied to patients with non-palpable breast cancer. One hundred and ten consecutive women with unilateral breast cancer were studied. Group 1 was made up of 80 patients with palpable breast cancer (mean age, 58 years) and group ...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200212000-00003

    authors: Fernandez A,Escobedo A,Benito E,Azpeitia D,Guma A,Prieto L,Moreno A,Martin-Comin J

    更新日期:2002-12-01 00:00:00

  • Osteoblastic and hyperostotic craniofacial lesion detected by 99mTc-labeled methylene diphosphonate bone scintigraphy and single-photon emission computed tomography/computed tomography: a pictorial essay.

    abstract::99mTc-bisphophonates bone scan, planar and single-photon emission computed tomography/computed tomography (SPECT/CT) modalities, is a commonly used technique that provides high sensitivity and specificity for detection of osseous metastases. However, besides bone metastases, SPECT/CT provides an accurate evaluation of...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001318

    authors: Ju H,Paycha F

    更新日期:2021-02-01 00:00:00

  • Bone scan index as metastatic bone disease quantifier and predictor of radium-223-dichloride biochemical response.

    abstract:OBJECTIVES:This work aims to assess whether the biochemical response of radium-223-dichloride treatment can be predicted based on the pretherapy bone scan, and consequently if bone scan index (BSI) and maximum lesion intensity have a place as alternatives or as complements to extent of bone disease (EOBD) scoring in pr...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001005

    authors: Roque V,Jessop M,Pereira L,Gape P,Dizdarevic S,Sousa E,Carolino E

    更新日期:2019-06-01 00:00:00

  • Comparison of 123I-MIBG SPECT-CT and 18F-DOPA PET-CT in the evaluation of patients with known or suspected recurrent paraganglioma.

    abstract:OBJECTIVES:Detection of recurrent disease is essential for treatment planning in patients with paraganglioma. The aim of this study was to compare 123I-metaiodobenzylguanidine (123I-MIBG) scintigraphy [whole-body and single-photon emission computed tomography (SPECT) computed tomography (CT) scanning] and fluorine-18-L...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328345a340

    authors: Rufini V,Treglia G,Castaldi P,Perotti G,Calcagni ML,Corsello SM,Galli G,Fanti S,Giordano A

    更新日期:2011-07-01 00:00:00

  • Diagnostic and prognostic impact of fluorine-18-fluorodeoxyglucose PET/CT in preoperative and postoperative setting of breast cancer patients.

    abstract:PURPOSE:The aim of this study was to assess the diagnostic and prognostic value of fluorine-18-fluorodeoxyglucose (F-FDG) PET/CT in patients with breast cancer (BC) in the preoperative and the postoperative setting. PATIENTS AND METHODS:Between 2011 and 2015, we prospectively enrolled 275 patients (mean age: 53 years)...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000671

    authors: Evangelista L,Cervino AR,Michieletto S,Saibene T,Ghiotto C,Guarneri V,Conte P,Reccia P,Saladini G

    更新日期:2017-06-01 00:00:00

  • Improving radiopharmaceutical supply chain safety by implementing bar code technology.

    abstract::The aim of this study was to describe and evaluate an approach for improving radiopharmaceutical supply chain safety by implementing bar code technology. We first evaluated the current situation of our radiopharmaceutical supply chain and, by means of the ALARM protocol, analysed two dispensing errors that occurred in...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000177

    authors: Matanza D,Hallouard F,Rioufol C,Fessi H,Fraysse M

    更新日期:2014-11-01 00:00:00

  • Immunoscintigraphy (BW 250/183) in neonates and infants with fever of unknown origin.

    abstract::Fever of unknown origin is defined as a temperature above 39.0 degrees C together with a white blood cell count > or = 15,000 mm-3, the duration of fever exceeding 2 weeks and a correct diagnosis not being obtained in the first week of hospitalization. In neonates and infants with fever of unknown origin, the localiza...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199811000-00003

    authors: Gratz S,Behr TM,Herrmann A,Meller J,Conrad M,Zappel H,Becker W

    更新日期:1998-11-01 00:00:00

  • Improving quantitative dosimetry in (177)Lu-DOTATATE SPECT by energy window-based scatter corrections.

    abstract:PURPOSE:Patient-specific dosimetry of lutetium-177 ((177)Lu)-DOTATATE treatment in neuroendocrine tumours is important, because uptake differs across patients. Single photon emission computer tomography (SPECT)-based dosimetry requires a conversion factor between the obtained counts and the activity, which depends on t...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000079

    authors: de Nijs R,Lagerburg V,Klausen TL,Holm S

    更新日期:2014-05-01 00:00:00

  • 201T1 and 99Tcm-J001X macrophage scintigraphy: two radionuclide imaging techniques for the surveillance of acute localized radiation over-exposures.

    abstract::The therapeutic or surgical management of acute localized irradiation is very complicated due to the delayed occurrence of ionizing radiation effects. There is a great need for non-invasive imaging techniques to delineate healthy from exposed tissues. Such a technique should be of value considering that spread of dama...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Perin F,Pittet JC,Hoffschir D,Daburon F,Normier G,Le Pape A

    更新日期:1995-07-01 00:00:00

  • Pharmacologic characterizations of a P2X7 receptor-specific radioligand, [11C]GSK1482160 for neuroinflammatory response.

    abstract:OBJECTIVE:The P2X7 receptor (P2X7R) is a key regulatory element in the neuroinflammatory cascade that provides a promising target for imaging neuroinflammation. GSK1482160, a P2X7R modulator with nanomolar binding affinity and high selectivity, has been successfully radiolabeled and utilized for imaging P2X7 levels in ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000660

    authors: Han J,Liu H,Liu C,Jin H,Perlmutter JS,Egan TM,Tu Z

    更新日期:2017-05-01 00:00:00

  • Failure of washout following gustatory stimulation in Warthin's tumour.

    abstract::Scintigraphically, Warthin's tumour usually demonstrates increased tracer uptake compared to normal adjacent salivary tissue. A case is presented in which tumour uptake is no greater than the normal adjacent gland. Gustatory stimulation results in failure of tumour tracer washout, and this finding rather than 'hot' sa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198806000-00007

    authors: Blue PW

    更新日期:1988-06-01 00:00:00

  • The efficacy of the available peptide receptor radionuclide therapy for neuroendocrine tumors: a meta-analysis.

    abstract:AIM:This study was carried out to compare the efficacy of Y, Lu, and combination of both radiotracers (tandem) peptide receptor radionuclide therapy (PRRT) in patients with inoperable and metastatic neuroendocrine tumors. MATERIALS AND METHODS:Systematic searches of PubMed and SciVerse Scopus databases were performed ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,meta分析

    doi:10.1097/MNM.0000000000000758

    authors: Dannoon SF,Alenezi SA,Elgazzar AH

    更新日期:2017-12-01 00:00:00

  • Wipe tests to assess 99Tcm surface contamination: effects of surface type, swab type and chemical form.

    abstract::The efficacy of wipe tests for assessing 99Tcm surface contamination was measured. Four types of surface were contaminated with four radiopharmaceuticals and wiped using four types of swab. The fraction of activity removed was measured by direct monitoring for each combination of surface, pharmaceutical and swab. The ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199102000-00005

    authors: Scott LE,Gibson CJ

    更新日期:1991-02-01 00:00:00

  • Management and evaluation of sodium [131I] iodide contamination after oral administration.

    abstract::Radioiodine therapy using oral administration of Iodine-131 (I) is a widespread employed strategy for the treatment of hyperthyroidism and thyroid cancer. Such a therapy requires well-trained staff, equipment and procedures regarding radiation safety. The aims of this work are to report an incidental experience of rad...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001276

    authors: Labbe E,Peyronnet D,Desmonts C,Vigne J

    更新日期:2020-11-01 00:00:00

  • The use of single photon emission computed tomography in depressive disorders.

    abstract::Single photon emission computed tomography (SPECT) and positron emission tomography (PET) have advanced our understanding of the biological underpinnings of depression. There is, however, considerable variability in the literature. Depression is a complex disorder with marked heterogeneity in diagnosis and treatment. ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-200503000-00004

    authors: Smith DJ,Cavanagh JT

    更新日期:2005-03-01 00:00:00

  • Clinical significance of decreased myocardial uptake of 123I-BMIPP in patients with stable effort angina pectoris.

    abstract::The aim of this study was to assess the feasibility of resting myocardial fatty acid metabolic imaging with 123I-beta-methyliodophenyl-pentadecanoic acid (123I-BMIPP) for the detection of patients with stable effort angina pectoris and to clarify the clinical significance of abnormal 123I-BMIPP images. Myocardial imag...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199512000-00003

    authors: Takeishi Y,Sukekawa H,Saito H,Nishimura S,Shibu T,Sasaki Y,Tomoike H

    更新日期:1995-12-01 00:00:00

  • Long-term follow-up using 18F-FDG PET/CT for postoperative olfactory neuroblastoma.

    abstract:PURPOSE:The present study evaluated the usefulness of postoperative fluorine-18 fluorodeoxyglucose (F-FDG) PET/computed tomography (CT) in the management of olfactory neuroblastoma (ONB). MATERIALS AND METHODS:Ten patients (eight men and two women; mean age, 48.5 years) with histologically confirmed ONB who underwent ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000135

    authors: Fujioka T,Toriihara A,Kubota K,Machida Y,Nakamura S,Kishimoto S,Ohashi I,Shibuya H

    更新日期:2014-08-01 00:00:00

  • Large variations occur in bone density measurements of children when using different software.

    abstract:BACKGROUND:Paediatric dual X-ray absorptiometry (DXA) studies present a number of technical problems. One of these is that the edge detection algorithms designed for the adult skeleton may fail for paediatric studies. Hologic provide alternative algorithms for low bone density studies. AIM:To assess low-density softwa...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200506000-00002

    authors: Simpson DE,Dontu VS,Stephens SE,Archbold LJ,Lowe V,O'Doherty MJ,Martin N,Coakley AJ

    更新日期:2005-06-01 00:00:00

  • Whole-body dynamic imaging with continuous bed motion PET/CT.

    abstract::Most dynamic imaging protocols require long scan times that are beyond the range of what can be supported in a routine clinical environment and suffer from various difficulties related to step and shoot imaging techniques. In this short communication, we describe continuous bed motion (CBM) imaging techniques to creat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000455

    authors: Osborne DR,Acuff S

    更新日期:2016-04-01 00:00:00

  • Propagation of measurement errors in glomerular filtration rate determination: a comparison of slope-intercept, single-sample and slope-only methods.

    abstract:BACKGROUND:Measurement errors occurring during glomerular filtration rate (GFR) studies propagate to an error in the calculated GFR. Previous work has modelled measurement errors for slope-intercept (SI-GFR), single-sample (SS-GFR) and slope-only (SO-GFR) methods. In this study, we have extended these models. The prima...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000977

    authors: Holness JL,Fleming JS,Chirehwa MT,Warwick JM

    更新日期:2019-04-01 00:00:00

  • National survey of imaging technologists in nuclear medicine 1998/99.

    abstract::This survey investigated the nature of imaging staff and the distribution and structure of nuclear medicine departments in the UK. Total numbers of cameras and average per department were lower than in 1989/90 but higher than the 1992/93 survey. Total whole time equivalents, average per department and average per came...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200105000-00016

    authors: Sanders L,Houston AS

    更新日期:2001-05-01 00:00:00

  • A phantom assessment of portable imaging and radio-guided surgery systems with technetium-99m and fluorine-18.

    abstract:AIM:To perform a detailed analysis of the performance of mobile intraoperative imaging systems and gamma probes in a phantom set-up, and compare this with a conventional gamma camera. METHODS:Two separate experiments were performed. In the first, a modified Jaszczak phantom equipped with five (99m)Tc-filled hot sphere...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e3283508577

    authors: Krohn T,Verburg FA,Brockmann H,Winz OH,Mottaghy FM,Behrendt FF

    更新日期:2012-05-01 00:00:00

  • SPET-generated colour-coded polar maps to quantify 99Tcm-MIBI and 123I-BMIPP uptake in chronically dysfunctional myocardium: comparison with coronary anatomy and wall motion.

    abstract::The combined use of 123I-BMIPP and 99Tcm-MIBI SPET imaging has been proposed as an alternative to PET for the non-invasive detection of jeopardized myocardium after a myocardial infarction, a mismatch accurately indicating jeopardized but still viable tissue. In this paper, a new quantitative approach is described, ex...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199712000-00005

    authors: Hambÿe AS,Dobbeleir A,Franken PR

    更新日期:1997-12-01 00:00:00

  • GFR measurement by simulating constant infusion with data acquired using a CdTe detector. A feasibility study.

    abstract::Conventional nuclear medicine methods for measuring glomerular filtration rate, GFR, are invalidated if the initial injection of radiopharmaceutical is tissued. An analytical method proposed by Veall and Gibbs in 1982 overcomes this difficulty but does require multiple blood samples. This paper investigates whether it...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198611000-00003

    authors: Casey M,Barker F,Duffy G

    更新日期:1986-11-01 00:00:00

  • RET gene mutation analysis and long-term clinical outcomes of medullary thyroid cancer patients.

    abstract:OBJECTIVE:Medullary thyroid carcinoma is a rare, potentially aggressive tumour, with relatively worse prognosis than well-differentiated thyroid cancer. We evaluated the long-term outcomes and prognosis of medullary thyroid carcinoma patients at a single institution in India and compared outcomes based on results of RE...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001264

    authors: Prabhu M,Shakya S,Ballal S,Ahmed Shamim S,Bal C

    更新日期:2020-11-01 00:00:00

  • Evaluation of 99Tcm-teboroxime scintigraphy for the differentiation of reversible from fixed defects: comparison with 201T1 redistribution and reinjection imaging.

    abstract::The aim of this study was to compare 99Tcm-teboroxime and 201T1 myocardial studies with particular regard to the classification of perfusion defects as reversible or fixed. Twenty patients with a history of previous myocardial infarction and suspected effort ischaemia underwent exercise 201T1 scintigraphy with early (...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199307000-00002

    authors: Bisi G,Sciagrà R,Santoro GM,Zerauschek F,Fazzini PF

    更新日期:1993-07-01 00:00:00

  • Time course of thyroglobulin autoantibodies in patients with differentiated thyroid carcinoma after radioiodine therapy.

    abstract::The time course of thyroglobulin (Tg) was monitored in patients with differentiated thyroid carcinoma after ablative therapy (thyroidectomy + 131I-treatment) with particular respect to endogeneous antibodies (Tg-ABs). In 232 patients (196 without Tg-ABs, 36 with Tg-ABs at the time of treatment) a sensitivity of 88% (a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198405000-00003

    authors: Moser E,Braun S,Kirsch CM,Kleinhans E,Buell U

    更新日期:1984-05-01 00:00:00