Abstract:
:Machinists and machine maintenance men working in the metal industry use metal-working fluids capable of causing irritant and allergic contact dermatitis. The objectives of this study were to find out the frequency of skin symptoms in machinists and machine maintenance men (metal workers) and to compare the risk of their skin symptoms to that in office workers (controls). A total of 726 male metal workers and 84 controls answered a structured telephone questionnaire enquiring about work, atopy, skin symptoms, their impact on life, etc. The risk of skin symptoms compared with that in the controls was estimated using a logistic regression analysis. Of the metal workers, 20% reported recurring or prolonged dermatitis on their hands or forearms during the past 12 months. The hand or forearm dermatitis (HD) affected mostly the metal workers' mood and their activities at work. Recurring dermatitis elsewhere (DE) than in the hands and in connection with work was reported by 10%. The risk of HD was about twofold and the risk of DE was about fourfold compared with that in the controls. The HD of machinists may be severe and affect their ability to work. DE may have clinical significance in machinists.
journal_name
Contact Dermatitisjournal_title
Contact dermatitisauthors
Suuronen K,Jolanki R,Luukkonen R,Alanko K,Susitaival Pdoi
10.1111/j.1600-0536.2007.01207.xsubject
Has Abstractpub_date
2007-10-01 00:00:00pages
259-64issue
4eissn
0105-1873issn
1600-0536pii
COD1207journal_volume
57pub_type
杂志文章abstract::Contact urticaria to potato was confirmed by skin testing in a 26-year-old male with atopic dermatitis, birch-pollen rhinoconjunctivitis and a history of immediate finger itching upon handling raw potato. The potato peel was non-reactive. The urticarial reactivity to potato could be transferred by the patient's serum ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1983.tb04315.x
更新日期:1983-03-01 00:00:00
abstract::Effects of test techniques on neomycin patch test results have not been thoroughly investigated. This study focuses on effects of dose and application time of neomycin sulfate patch tests on test results. The effects are assessed both visually and by perfusion. 16 subjects positive to neomycin are retested with neomyc...
journal_title:Contact dermatitis
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1034/j.1600-0536.2000.043005283.x
更新日期:2000-11-01 00:00:00
abstract::A human 4-h patch test has recently been developed for testing the irritation hazard potential of chemicals. The original method was developed for comparative irritation assessments relative to benchmark irritants using simple statistical tests. In this context, the method has been shown to be robust in intralaborator...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1998.tb05706.x
更新日期:1998-04-01 00:00:00
abstract::5 cases of allergic contact dermatitis due to budesonide are described. We studied the antigen determinant structures in these cases by applying patch tests with several substances related to budesonide. 2 cases showed cross-reactions to both amcinonide and prednisolone acetate. The antigen determinant structure is al...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1993.tb03404.x
更新日期:1993-04-01 00:00:00
abstract::The aim of our study was to report the frequency of sensitization to hairdressing allergens in a group of patients with contact dermatitis, in whom previous treatments with hair dyes or permanent wave solutions were suspected to be the cause. 49 of 261 hairdressers' clients (18.7%), who were patch tested with the hair...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1992.tb00893.x
更新日期:1992-02-01 00:00:00
abstract::Between January 1993 and February 2002, 40 of 1354 (3%) workers who attended a tertiary referral occupational dermatology clinic were diagnosed with allergic contact dermatitis (ACD) from epoxy resin systems (ER). 20 of these patients were followed up at least 2 years post-diagnosis to establish prognosis. Characteris...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.0105-1873.2005.00542.x
更新日期:2005-03-01 00:00:00
abstract:BACKGROUND:Although citation analysis represents an increasingly common method for examining the performance of scientific journals, few longitudinal studies have been conducted in the specialist fields of dermatology. OBJECTIVES:The objective of this study was to provide the first comprehensive bibliometric analysis ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2009.01609.x
更新日期:2009-10-01 00:00:00
abstract::The Danish Twin Register represents a population-based twin sample where the twins enter the Register independently of disease. All female twins born between 1906-30 and available in the Register in January 1978 were sent a questionnaire concerning possible nickel sensitivity. Among 746 pairs living in the eastern par...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1983.tb04393.x
更新日期:1983-07-01 00:00:00
abstract::In the first conundrum, permanent hair dyeing involves the use of aromatic amines such as p-phenylenediamine (PPD), whose oxidation is pivotal to the dyeing process, but also generates potent allergens. Despite prolonged efforts by industry to search for safer alternatives, hair dyeing is still reliant on this type of...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.13171
更新日期:2019-04-01 00:00:00
abstract::The expression of surface-bound immunoglobulin E by dendritic cells within cutaneous tissue has been compared in atopic and contact dermatitis. 45 patients were recruited into 4 groups using clinical criteria and patch testing to a standard series of allergens: atopic (12 cases), allergic contact dermatitis (14 cases)...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1991.tb01799.x
更新日期:1991-08-01 00:00:00
abstract::The aim of this study was to elucidate the role of the C11-OH substituent of the corticosteroid molecule in relation to contact allergy to corticosteroids. This group, which is essential for glucocorticoid activity, is not present in other steroid molecules, such as deoxycortisol, progestagens, testosterone, and estro...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1992.tb00286.x
更新日期:1992-03-01 00:00:00
abstract::Among patients consecutively patch tested at St John's from 1984-1989, the prevalence rate of formaldehyde sensitivity was 2.2% for men and 3.7% for women. During these 6 years, 117 women were primarily sensitized by formaldehyde, of whom 61 (52%) had hand eczema. Exposure was occupational in 12% and domestic in 88%. ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1991.tb01874.x
更新日期:1991-11-01 00:00:00
abstract::Based on the information of the interdisciplinary task force on allergy diagnostics in the metal branch, in 2001, the German Contact Dermatitis Research Group (DKG) compiled two metalworking fluid (MWF) test series with currently and previously used components, respectively. After 2 years of patch testing, we present ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.0105-1873.2004.00416.x
更新日期:2004-09-01 00:00:00
abstract:BACKGROUND:The prevalence of p-phenylenediamine (PPD) sensitization is 4% in the patch tested population and varies between zero and 1.5% in the general population. Hair dye is a recognised sensitization source. OBJECTIVES:To define the prevalence rates of PPD sensitization in the general and patch tested populations ...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.12354
更新日期:2015-06-01 00:00:00
abstract::A predictive study comparing the sensitizing potentials of some topical antimicrobials, using a modified Beuhler's technique, showed that over-the-counter (OTC) antimicrobials were more sensitizing than prescribed topical antibiotics. Among OTC antimicrobials, proflavine was the most potent sensitizer (4/10 guinea pig...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1989.tb04730.x
更新日期:1989-09-01 00:00:00
abstract::Common emulsifiers were tested in over 1,200 patients with eczema. Triethanolamine stearate tested at 5% in petrolatum caused irritant reactions in 9.5% of the patients. On the other hand, non-ionic emulsifying agents tested at 10-20% produced irritation in only a few cases. Allergic reactions were found in 2.1% of th...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1976.tb03027.x
更新日期:1976-08-01 00:00:00
abstract::From February 1989 to January 1990, the Swiss Contact Dermatitis Research Group conducted a 1-year study to examine the frequency of sensitization to a series of 13 common preservatives. A group of 2295 consecutive outpatients with suspected allergic contact dermatitis (age range 7-90 years, with a mean age of 42; 911...
journal_title:Contact dermatitis
pub_type: 杂志文章,多中心研究,评审
doi:10.1111/j.1600-0536.1994.tb00597.x
更新日期:1994-05-01 00:00:00
abstract::Late reactions to iodinated contrast media are frequent. Cutaneous manifestations are the commonest, in which maculopapular exanthema, a type of cutaneous presentation, is widespread. Controversy exists about the utility of the skin test in the management of these reactions. The aim of this study is to analyse the cli...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2006.00957.x
更新日期:2006-12-01 00:00:00
abstract::The ingredients previously reported to cause protective glove allergy are presented and evaluated for strength of evidence. Allergens that have caused both delayed hypersensitivity and contact urticaria are considered for rubber, plastic, leather, and textile gloves. The current guidelines regarding glove manufacture ...
journal_title:Contact dermatitis
pub_type: 杂志文章,评审
doi:10.1111/j.1600-0536.2009.01580.x
更新日期:2009-09-01 00:00:00
abstract::A 45-year-old woman developed dermatitis of the face after she applied a cosmetic package comprising day and night creams. Patch tests were performed with the British Contact Dermatitis Society (BCDS) standard, bases + preservatives, and cosmetic series in addition to samples of both creams and the individual constitu...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2007.00972.x
更新日期:2007-04-01 00:00:00
abstract::Development of local allergic reactions after different application times with Finn Chambers was recorded in 34 nickel-sensitive patients. Biologically significant amounts of nickel seemed to penetrate the skin within a few hours, although physical penetration was minimal. Nickel was detected only in the upper keratin...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1985.tb01131.x
更新日期:1985-05-01 00:00:00
abstract:BACKGROUND:Chromium-tanned leather footwear, which releases >3 ppm hexavalent Cr(VI), may pose a risk of sensitizing and eliciting allergic dermatitis. OBJECTIVES:To determine the content and potential release of chromium in leather footwear and to discuss the prevention of chromium contact allergy and dermatitis. ME...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2011.02053.x
更新日期:2012-05-01 00:00:00
abstract::The aim of the study is to describe the ability of patients with allergic contact dermatitis to avoid exposure to allergens in cosmetics. The study is a questionnaire survey among 382 patients with contact allergy to preservatives and fragrances, included from 3 dermatological clinics. The questionnaire included quest...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2007.01170.x
更新日期:2007-08-01 00:00:00
abstract:BACKGROUND:Contact allergy to rubber additives is common, particularly in patients with occupational dermatitis. OBJECTIVES:To descriptively analyse and compare patch test reactions in patients patch tested both with the baseline series and with an additional 'rubber series' as used in the department. METHODS:Patch t...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/cod.12651
更新日期:2016-12-01 00:00:00
abstract::We have studied a group of 104 patients with pompholyx, to investigate the relationship between allergological factors and its etiopathogenesis. The following examinations were performed: blood sampling (routine tests and IgE levels), allergological tests (patch, prick, intradermal, and oral provovation tests with nic...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1992.tb00862.x
更新日期:1992-01-01 00:00:00
abstract::A popular "skin protector" consisting of an emulsion-like foam of lipophilic and hydrophilic substances (Marly skin) was evaluated in a previously described repetitive irritation guinea pig model. The product failed to inhibit the irritation due to sodium lauryl sulphate and toluene. In striking contrast to the recomm...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1993.tb03486.x
更新日期:1993-08-01 00:00:00
abstract::3 minor resin acids and 7 commercial modified-colophony products of different origins were studied by experimental sensitization by means of a modified FCA method. All 3 resin acids were almost negative. The commercial products gave different results. While the maleic-modified product of Greek origin showed a strong s...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1990.tb03229.x
更新日期:1990-08-01 00:00:00
abstract::A cohort of initially 111 office apprentices was prospectively followed for the duration of their training (2 and 3 years, respectively). The point prevalence of (slight) irritant or atopic hand eczema was 18.9% in the initial and 25.0% in the final examinations. Altogether, 37 cases of (slight) hand eczema were noted...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:
更新日期:1998-02-01 00:00:00
abstract::A 59-year-old saleswoman of black hats presented with a severe purpuric eruption of the exposed areas of the face, neck and arms. Patch testing to paraphenylenediamine produced a purpuric test reaction. Similar eruptions have been reported due to N-isopropyl-N-phenylparaphenylenediamine (IPPD), a rubber antioxidant. T...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.1978.tb03793.x
更新日期:1978-08-01 00:00:00
abstract:BACKGROUND:Wheat protein derivatives are used in a variety of products worldwide. Gluten is commercially used 'as is' or with modifications such as hydrolysis, which is carried out to overcome its insolubility. Several cases of contact urticaria following exposure to hydrolysed wheat protein (HWP) in cosmetics or of an...
journal_title:Contact dermatitis
pub_type: 杂志文章
doi:10.1111/j.1600-0536.2012.02168.x
更新日期:2013-02-01 00:00:00