Abstract:
BACKGROUND:Auto-regulated inspiratory support mode (ARIS) is an original closed-loop pressure-support system that regulates the slope ("A") and the initial level ("B") of the applied inspiratory pressure, in order to achieve an optimal minute ventilation under constrained respiratory frequency, tidal volume, and maximum inspiratory airway pressure. The servo-controlled design results in a more or less decreasing applied pressure. OBJECTIVE:The aim of this study was to evaluate the ARIS behavior, compared with pressure-support ventilation at a constant applied pressure. METHODS:ARIS and pressure-support ventilation were randomly applied to 2 pig models of increasing ventilatory demand induced by a rebreathing test (n = 6), and of altered lung compliance induced by bronchoalveolar lavage (n = 6). The breathing pattern, work of breathing, and blood gas values were compared. ARIS automatically increased the mean inspiratory airway pressure in both groups. This increase was obtained in the rebreathing group by increasing "B" (35 +/- 3.5 cm H2O vs 42.8 +/- 2.5 cm H2O) and in the lung-injury group by decreasing the absolute value of "A" (25 +/- 5.5 cm H2O/s vs 14.7 +/- 8.6 cm H2O/s). RESULTS:There were significant differences (p < 0.05) between ARIS and pressure-support ventilation. In the rebreathing group, tidal volume was 692 +/- 63 mL versus 606 +/- 96 mL, work of breathing was 1.17 +/- 0.45 J/L versus 1.44 +/- 0.27 J/L, and P(aCO2) was 54 +/- 9 mm Hg versus 63 +/- 7 mm Hg. In the lung-injury group, respiratory frequency was 25 +/- 4 breaths/min versus 42 +/- 10 breaths/min, tidal volume was 477 +/- 67 mL versus 300 +/- 63 mL, work of breathing was 0.54 +/- 0.3 J/L versus 0.99 +/- 0.45 J/L, and P(aCO2) was 36 +/- 8 mm Hg versus 53 +/- 15 mm Hg. CONCLUSIONS:The ARIS servo control operates correctly, maintaining efficient ventilation facing an increase in respiratory demand or a decrease in respiratory system compliance.
journal_name
Respir Carejournal_title
Respiratory careauthors
Desmettre TJ,Chambrin MC,Mangalaboyi J,Pigot A,Chopin Ckeywords:
subject
Has Abstractpub_date
2005-08-01 00:00:00pages
1050-61issue
8eissn
0020-1324issn
1943-3654journal_volume
50pub_type
杂志文章相关文献
Respiratory Care文献大全abstract:BACKGROUND:The addition of heated humidification to CPAP has been shown to improve nasal adverse effects in subjects with obstructive sleep apnea (OSA). However, current data regarding improvement in CPAP adherence is conflicting. Furthermore, there are no data from a tropical climate area with a high humidity level. ...
journal_title:Respiratory care
pub_type: 杂志文章,随机对照试验
doi:10.4187/respcare.04536
更新日期:2016-09-01 00:00:00
abstract::Mechanical ventilation is frequently used in pediatric patients to ensure adequate gas exchange, ameliorate respiratory distress, and enable resolution of pulmonary or other disorders. However, a number of important challenges remain in the pediatric population because there is a paucity of large-scale randomized cont...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.07029
更新日期:2019-07-01 00:00:00
abstract:BACKGROUND:Switching patients affected by early severe ARDS and undergoing extracorporeal membrane oxygenation (ECMO) from controlled ventilation to spontaneous breathing can be either beneficial or harmful, depending on how effectively the breathing pattern is controlled with ECMO. Identifying the factors associated w...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.07391
更新日期:2020-07-01 00:00:00
abstract::Fibrosing mediastinitis is underdiagnosed because of the nonspecific character of the presenting symptoms. The endobronchial findings obtained via flexible bronchoscopy are not defined in the literature. We describe 3 cases of fibrosing mediastinitis, most likely caused by histoplasmosis. All 3 patients presented with...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2003-11-01 00:00:00
abstract:BACKGROUND:In patients suffering from brain injury, end-tidal PCO2 (PETCO2 ) monitoring is controversial, but transcutaneous PCO2 (PtcCO2 ), which is noninvasive and utilizes immediate display, may be an alternative method. We hypothesized that PtcCO2 would be more accurate than PETCO2 for monitoring PaCO2 in patients ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.02726
更新日期:2014-08-01 00:00:00
abstract:OBJECTIVE:Evaluate the effects of continuous positive airway pressure (CPAP)/positive end-expiratory pressure (PEEP) and pressure support ventilation (PSV) on work of breathing (WOB). METHODS:With 13 anesthetized lambs we measured WOB with an esophageal balloon and flow signals. All the animals were sedated, intubated...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2003-07-01 00:00:00
abstract:BACKGROUND:Measurement of functional residual capacity (FRC) is now possible at bedside, during mechanical ventilation. OBJECTIVES:To determine the relationship of measured absolute and relative predicted FRC values to oxygenation and respiratory-system compliance, and to identify variables that influence FRC in venti...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2010-05-01 00:00:00
abstract:BACKGROUND:Field walking tests are commonly used in patients with chronic pulmonary diseases for assessment of functional capacity. However, the physiological demands and magnitude of desaturation on 6-min walk test (6MWT), incremental shuttle walk test (ISWT), and endurance shuttle walk test (ESWT) have not been inves...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.07171
更新日期:2020-05-01 00:00:00
abstract:BACKGROUND:Patient work of breathing (WOB) during assisted ventilation is reduced when inspiratory flow (V(I)) from the ventilator exceeds patient flow demand. Patients in acute respiratory failure often have unstable breathing patterns and their requirements for V(I) may change from breath to breath. Volume control ve...
journal_title:Respiratory care
pub_type: 临床试验,杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract:OBJECTIVE:To determine whether propofol affects spontaneous breathing patterns in critically ill patients recovering from respiratory failure during initial attempts at liberation from mechanical ventilation. DESIGN:Observational cohort study. PATIENTS:Ten critically ill patients in the medical intensive care unit of...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2002-02-01 00:00:00
abstract:BACKGROUND:Chest x-ray (CXR) is widely used for diagnosing and screening pulmonary tuberculosis (PTB), yet its validity is debatable and its costs are relatively high. This study aimed to determine the validity of CXR screening in detecting radiological findings compatible with active PTB or with old healed tuberculos...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.01475
更新日期:2012-07-01 00:00:00
abstract:BACKGROUND:The periodic administration of positive airway pressure combined with directed cough could aid mucus clearance in patients with cystic fibrosis (CF) and severe airway obstruction. OBJECTIVE:To compare the short-term effect of positive expiratory pressure (PEP) physiotherapy via mask (mask PEP), continuous p...
journal_title:Respiratory care
pub_type: 杂志文章,随机对照试验
doi:
更新日期:2006-10-01 00:00:00
abstract:BACKGROUND:Pneumothorax is a well known complication of pulmonary tuberculosis (TB), particularly in patients with advanced TB. METHODS:At our national TB-referral hospital, we compared the medical records of 53 TB patients with pneumothorax and 106 TB patients without pneumothorax, seen in 2003 to 2008. We analyzed d...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.00695
更新日期:2011-03-01 00:00:00
abstract:BACKGROUND:Electrical impedance tomography measures changes in lung impedance, which are mainly related to changes in lung volume. We used electrical impedance tomography to investigate the effects of high-flow nasal cannula (HFNC) and body position on global and regional end-expiratory lung impedance variation (ΔEELI)...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.02086
更新日期:2013-04-01 00:00:00
abstract::Post-traumatic pulmonary pseudocyst is an uncommon cavitary lesion of the lung, which generally develops after blunt chest trauma. We saw a 22-year-old man with chest trauma, hemopneumothorax, and hemoptysis, on the day he fell from an electrical pylon. Intubation in the emergency department was followed by 4 days of ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2009-04-01 00:00:00
abstract:BACKGROUND:Limited adult data suggest that airway driving pressure might better reflect the potential risk for lung injury than tidal volume based on ideal body weight, and the parameter correlates with mortality in ARDS. There is a lack of data about the effect of driving pressure on mortality in pediatric ARDS. This ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.08024
更新日期:2020-10-06 00:00:00
abstract::Infants have low tidal volume, vital capacity, and functional residual capacity, and short respiratory cycles (low I:E ratio), which result in a low residence time for aerosol particles and, thus, low pulmonary deposition of aerosol particles (< 1% of the nominal dose), compared to adults (8-22%). Scintigraphy data su...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2004-06-01 00:00:00
abstract:BACKGROUND:Spirometry is important for the differential diagnosis of dyspnea. However, some patients cannot exhale for ≥6 s to achieve the American Thoracic Society/European Respiratory Society criteria. The aim of this study was to demonstrate the reliability of a new parameter that quantifies the degree of concavity ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.05016
更新日期:2017-03-01 00:00:00
abstract:BACKGROUND:Extracorporeal membrane oxygenation (ECMO) is often used in patients with severe respiratory failure to improve oxygenation and survival. ECMO gives the lungs an opportunity to rest and recover. The addition of prone positioning therapy used concurrently with ECMO can further aid in optimizing alveolar recru...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.03882
更新日期:2016-02-01 00:00:00
abstract:BACKGROUND:Peak expiratory flow (PEF) is a spirometric test that detects obstructive changes in the respiratory tract; has good correlation with the FEV1; and is much less expensive, simpler, and easier to perform under field conditions than FEV1. Chronic silicosis is also known to have obstructive features in advanced...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.04903
更新日期:2016-12-01 00:00:00
abstract:BACKGROUND:This study compared 3 nebulizer technologies for inter- and intradevice reproducibility, humidification, and fill volume sensitivity during mechanical ventilation: a breath-enhanced jet nebulizer, a vibrating mesh nebulizer, and a jet nebulizer. The breath-enhanced jet nebulizer featured a new design located...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.07639
更新日期:2020-10-01 00:00:00
abstract:BACKGROUND:Home mechanical ventilation (HMV) is a routine method of treatment for patients with chronic ventilatory failure. Over the last 20 y, a marked development in HMV has been noted in terms of its prevalence and the changing proportion of patients with various indications. However, data on HMV come exclusively f...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.03126
更新日期:2015-04-01 00:00:00
abstract::Hospital-wide computerized information systems evolved from the need to capture patient information and perform billing and other financial functions. These systems, however, have fallen short of meeting the needs of respiratory care departments regarding work load assessment, productivity management, and the level of...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:
更新日期:2004-04-01 00:00:00
abstract:OBJECTIVE:To investigate the predictive value of the maximal inspiratory pressure obtained by a digital vacuometer using a unidirectional valve (P(ImaxUV)) as to weaning outcome, and to compare its performance with the respiratory drive using airway occlusion pressure at 0.1 second (P(0.1)), and P(0.1)/P(ImaxUV). METH...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.01489
更新日期:2012-08-01 00:00:00
abstract:BACKGROUND:Symptom burden increases during pulmonary exacerbations of cystic fibrosis (CF), and patient-reported outcome measures (PROMs) are often used to evaluate symptoms as either primary or secondary outcomes. However, there is currently no guidance on the use of PROMs to assess symptom burden during pulmonary exa...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.05638
更新日期:2018-03-01 00:00:00
abstract:BACKGROUND:Studies on the submaximal aerobic capacity of exclusive narghile smokers (ENS) seem necessary in view of effective prevention of cardiorespiratory diseases. The goal of the study was to assess, by 6-min walk test (6MWT) data, the submaximal aerobic capacity of ENS, to identify factors influencing their 6-min...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.03058
更新日期:2014-11-01 00:00:00
abstract:BACKGROUND:Adaptive pressure control is a mode of mechanical ventilation where inflation pressure is adjusted by the ventilator to achieve a target tidal volume (VT). This means that as patient effort increases, inflation pressure is reduced, which may or may not be clinically appropriate. The purpose of this study was...
journal_title:Respiratory care
pub_type: 杂志文章
doi:
更新日期:2009-11-01 00:00:00
abstract::Functional residual capacity (FRC) is essentially the alveolar volume and a determinant of both oxygenation and respiratory system compliance (CRS). ARDS decreases FRC, and sufficient PEEP restores FRC; thus, assessments of PEEP by its impact on oxygenation and CRS are intimately linked. PEEP also can ameliorate or ag...
journal_title:Respiratory care
pub_type: 杂志文章,评审
doi:10.4187/respcare.04657
更新日期:2016-06-01 00:00:00
abstract:BACKGROUND:The profession of respiratory therapy (RT) continues to grow both in number, due to population growth and an ever-increasing aging population, and scope of practice, due to both new and expanded roles and responsibilities in divergent areas of clinical practice. Instructional technology, including distance ...
journal_title:Respiratory care
pub_type: 杂志文章
doi:10.4187/respcare.01197
更新日期:2011-11-01 00:00:00
abstract:BACKGROUND:Bronchodilator treatment for asthma can be provided with various aerosol-generating devices and methods. There have been no randomized trials of a breath-actuated nebulizer versus continuous 1-hour nebulization and/or small-volume constant-output nebulizer in pediatric asthma patients. METHODS:We conducted ...
journal_title:Respiratory care
pub_type: 杂志文章,随机对照试验
doi:10.4187/respcare.00142
更新日期:2011-06-01 00:00:00