Refillable point source for motion correction during first-pass radionuclide angiography.

Abstract:

:First-pass radionuclide angiography, for the evaluation of ventricular function during peak physiological stress, requires the use of a low-energy point source for correction of motion artifacts. A design for the construction of a refillable 125I point source is presented.

journal_name

Nucl Med Commun

authors

Hirsch JI,Fuhs BE,Tatum JL,Tatum TG

doi

10.1097/00006231-199201000-00009

keywords:

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

53-4

issue

1

eissn

0143-3636

issn

1473-5628

journal_volume

13

pub_type

杂志文章
  • A routine method for using sodium iodide to stabilize sodium pertechnetate [99Tcm] dispensed for the preparation of 99Tcm-exametazime.

    abstract::When preparing 99Tcm-exametazime, it is important to use sodium 99Tcm-pertechnetate that is less than 2 h old. The addition of sodium iodide (NaI) to 99Tcm-pertechnetate is known to extend this time to 6 h. This paper describes a technique for implementing this in routine practice. Sterile kits consisting of 440 micro...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199205000-00003

    authors: Millar AM

    更新日期:1992-05-01 00:00:00

  • Reductions in finger doses for radiopharmaceutical dispensing afforded by a syringe shield and an automatic dose dispenser.

    abstract::A gamma extremity monitoring system (GEMS) has been used to measure finger doses during radio-nuclide dispensing procedures. GEMS uses a small semi-conductor probe that can be attached to a finger from which a continuous read-out can be obtained that is related to dose rate. The pattern of dose accumulation can be ana...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199902000-00013

    authors: Montgomery A,Anstee DE,Martin CJ,Hilditch TE

    更新日期:1999-02-01 00:00:00

  • Scatter correction for first-pass radiocardiography.

    abstract::The effect of the dual window scatter subtraction method was tested for first-pass radiocardiography using 99Tcm. The photopeak window of 126-154 keV (20%) and Compton window of 93-125 keV (30%) were used. The set of scattered images was multiplied by a factor of 0.4 and subtracted from the primary images. The size of...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199611000-00009

    authors: Kauppinen T,Koskinen M,Kööbi T

    更新日期:1996-11-01 00:00:00

  • The role of positron emission tomography with fluorine-18-deoxyglucose in identifying colorectal cancer metastases to liver.

    abstract::Liver metastasis is a common consequence of colorectal carcinoma. Early and accurate detection of liver metastasis is crucial for a decision about partial hepatectomy, which is considered a standard and potentially curative therapy in such a setting. The presence of extrahepatic metastases will exclude surgical resect...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200009000-00002

    authors: Zhuang H,Sinha P,Pourdehnad M,Duarte PS,Yamamoto AJ,Alavi A

    更新日期:2000-09-01 00:00:00

  • Prognostic value of impaired myocardial fatty acid uptake in patients with acute myocardial infarction.

    abstract::Impaired cardiac fatty acid uptake, assessed by the radiolabelled fatty acid analogue beta-methyl-p-iodophenyl pentadecanoic acid (I-123-BMIPP), is observed in the myocardium following acute ischaemic events, but the long-term prognostic implication has not been established. This study aimed to determine the prognosti...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00006231-200010000-00003

    authors: Nakata T,Kobayashi T,Tamaki N,Kobayashi H,Wakabayashi T,Shimoshige S,Oh-Hori K,Hamabe K,Hirasawa K,Matsuki T,Shogase T,Furudate M,Shimamoto K

    更新日期:2000-10-01 00:00:00

  • Half-time myocardial perfusion SPECT imaging with attenuation and Monte Carlo-based scatter correction.

    abstract:PURPOSE:To test the potential of a new reconstruction algorithm with Monte Carlo-based scatter correction in half-time myocardial perfusion single-photon emission computed tomography (SPECT). MATERIALS AND METHODS:The mathematical four-dimensional NURBS-based Cardiac-Torso phantom and the SIMIND Monte Carlo simulation...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0b013e328349c765

    authors: Kangasmaa TS,Kuikka JT,Vanninen EJ,Mussalo HM,Laitinen TP,Sohlberg AO

    更新日期:2011-11-01 00:00:00

  • Incidence, severity and clinical course of right ventricular involvement after acute inferior myocardial infarction; assessment by sequential 99Tcm-pyrophosphate scan and gated blood pool scan.

    abstract::To evaluate the incidence, severity and clinical course of right ventricular (RV) involvement after acute inferior myocardial infarction (IMI), 78 patients (pts) with IMI were investigated by both 99Tcm-pyrophosphate (PYP) scan and gated blood pool scan (GBPS). GBPS was performed at admission and 10 days, whereas 99Tc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198612000-00007

    authors: Nishimura T,Yasuda T,Gold HK,Leinbach RC,Boucher CA,McKusick KA,Strauss HW

    更新日期:1986-12-01 00:00:00

  • Preparation and properties of 99Tcm-exametazime using stannous ion augmentation of fractionated cold kits.

    abstract::Fractionation of 99Tcm-exametazime enables several patients doses to be prepared from one vial. To overcome the disadvantages of storage at -70 degrees C, storage at higher temperatures was investigated with replacement of stannous ions before use. Kits were fractionated using a nitrogen-purged 0.9% w/v sodium chlorid...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199903000-00013

    authors: Baker RJ

    更新日期:1999-03-01 00:00:00

  • Estimation of ascitic fluid volume using 99Tcm labelled macroaggregated albumin.

    abstract::We have assessed the usefulness of a radionuclide dilution method for estimation of ascitic fluid volume. 99Tc(m) macroaggregated albumin (10 MBq) was injected into the peritoneal fluid. Multiple samples were taken using a trocath peritoneal dialysis catheter over a 4-h period. Blood samples were taken at the same tim...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200012000-00009

    authors: Notghi A,Williams NR,Kehoe S,Smith NB,Harding LK

    更新日期:2000-12-01 00:00:00

  • The clinical usefulness of the fingers-to-palm ratio in different hand microcirculatory abnormalities.

    abstract::A non-invasive nuclear medicine technique was developed to screen patients with painful hands so as to separate patients with a normal from those with an abnormal microcirculation of the hands in different clinical conditions. Such a technique is important, as the other methods available are either subjective or rathe...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-200007000-00010

    authors: Galuska L,Garai I,Csiki Z,Varga J,Bodolay E,Bajnok L

    更新日期:2000-07-01 00:00:00

  • Fluorodeoxyglucose-avid focal lesions and extramedullary disease on 18F-FDG PET/computed tomography predict the outcomes of newly diagnosed symptomatic multiple myeloma patients.

    abstract:PURPOSE:To investigate whether the number of fluorodeoxyglucose (FDG)-avid focal lesions and the presence of extramedullary disease (EMD) on F-FDG PET/computed tomography (PET/CT) can predict the outcomes of newly diagnosed symptomatic multiple myeloma patients. METHODS:We performed a meta-analysis to research the pro...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000001242

    authors: Zhong X,Diao W,Zhao C,Jia Z

    更新日期:2020-06-23 00:00:00

  • The effects of informational intervention on state anxiety and satisfaction in patients undergoing bone scan.

    abstract::The aim of the study was to identify the most beneficial mode, in terms of anxiety reduction, of giving patients information prior to them undergoing a bone scan. (Research has identified the scan procedure as having a demonstrative effect on anxiety.) Additionally, satisfaction with the adequacy of the information wa...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/00006231-199411000-00011

    authors: Leckie J

    更新日期:1994-11-01 00:00:00

  • Prognostic value of quantitative PET/CT in patients with a nonsmall cell lung cancer and another primary cancer.

    abstract:OBJECTIVE:The staging and management of patients with newly diagnosed nonsmall cell lung cancer (NSCLC) in the setting of recently diagnosed other (metachronous or synchronous) primary cancer are challenging. This retrospective cohort study was carried out to test our hypothesis that baseline 2-deoxy-2-[F]fluoro-D-gluc...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000627

    authors: Zhu X,Liao C,Penney BC,Li F,Ferguson MK,Simon CA,Wu T,Liu H,Pu Y

    更新日期:2017-02-01 00:00:00

  • Focus localization in patients with partial epilepsy with 99Tcm-HMPAO SPECT under continuous surface EEG monitoring.

    abstract::Our study was aimed at determining the validity of 99Tcm-HMPAO single photon emission computed tomography (SPECT) in the localization of the epileptogenic focus by correlating this diagnostic method with other auxiliary investigations such as surface EEG and X-ray transmission computed tomography (CT). Twenty-eight pa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199203000-00002

    authors: Verhoeff NP,Weinstein HC,Aldenkamp AP,Overweg J,Van Royen EA,Verbeeten B Jr

    更新日期:1992-03-01 00:00:00

  • 99Tcm-MAG3: a sensitive indicator for evaluating perfusion and rejection of renal transplants.

    abstract::Radionuclide renography has a role in evaluating perfusion of transplanted kidneys. In the course of rejection, cortical perfusion decreases before urinary excretion changes. Based on the facts that 99Tcm-MAG3 has different pharmacokinetics and shows a higher kidney-to-background count ratio than 99Tcm-DTPA, we postul...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Oriuchi N,Miyamoto K,Hoshino K,Imai J,Takahashi Y,Sakai S,Shimada A,Endo K

    更新日期:1997-05-01 00:00:00

  • Quantitation of skeletal muscle necrosis using 99Tcm-pyrophosphate with SPECT in a canine model.

    abstract::Patients with acute arterial occlusion may suffer from significant muscle necrosis. It is important to determine the amount of regional muscle necrosis for prognostic purposes and evaluation of therapy. We have used technetium-99m-pyrophosphate (PPi) with single photon emission computed tomography (SPECT) to quantitat...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199002000-00009

    authors: Yip TC,Houle S,Hayes G,Forrest I,Nelson L,Walker PM

    更新日期:1990-02-01 00:00:00

  • Appropriate utilization of semi-quantitative analysis in salivary scintigraphy.

    abstract:AIM:The purpose of this case-control study was to determine whether semi-quantitative indices derived from salivary time-activity curves (TACs) are useful in the diagnosis and management of xerostomia. METHODS:Twenty-six healthy volunteers and 83 consecutive patients with xerostomia, including a subset of 40 patients ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200412000-00009

    authors: Booker J,Howarth D,Taylor L,Voutnis D,Sutherland D

    更新日期:2004-12-01 00:00:00

  • Time course of thyroglobulin autoantibodies in patients with differentiated thyroid carcinoma after radioiodine therapy.

    abstract::The time course of thyroglobulin (Tg) was monitored in patients with differentiated thyroid carcinoma after ablative therapy (thyroidectomy + 131I-treatment) with particular respect to endogeneous antibodies (Tg-ABs). In 232 patients (196 without Tg-ABs, 36 with Tg-ABs at the time of treatment) a sensitivity of 88% (a...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198405000-00003

    authors: Moser E,Braun S,Kirsch CM,Kleinhans E,Buell U

    更新日期:1984-05-01 00:00:00

  • Wipe tests to assess 99Tcm surface contamination: effects of surface type, swab type and chemical form.

    abstract::The efficacy of wipe tests for assessing 99Tcm surface contamination was measured. Four types of surface were contaminated with four radiopharmaceuticals and wiped using four types of swab. The fraction of activity removed was measured by direct monitoring for each combination of surface, pharmaceutical and swab. The ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199102000-00005

    authors: Scott LE,Gibson CJ

    更新日期:1991-02-01 00:00:00

  • Isometric exercise testing and echocardiography at rest in aortic valve incompetence.

    abstract::Thirty patients with aortic valve incompetence and 21 control subjects were examined by M-mode echocardiography at rest and radionuclide ventriculography during submaximal handgrip exercise. The patients had greater left ventricular dimensions and end-systolic wall stress values but peak systolic wall stress values di...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-199004000-00004

    authors: Groundstroem K,Huikuri H,Korhonen U,Ikäheimo M,Heikkilä J,Torniainen P,Linnaluoto M,Takkunen J

    更新日期:1990-04-01 00:00:00

  • Dynamic evaluation of absorbed dose to the bladder wall with a balloon-bladder phantom during a study using [(18)F]fluorodeoxyglucose positron emission imaging.

    abstract::An accurate evaluation of the absorbed dose to the bladder wall from 2-[(18)F]fluoro-2-deoxy-d-glucose (FDG) is clinically important because the bladder is considered as a critical organ in most positron emission tomography (PET) studies that cumulate about 20% of the total activity injection during image procedures. ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200208000-00008

    authors: Wu TH,Liu RS,Dong SL,Chung YW,Chou KL,Lee JS

    更新日期:2002-08-01 00:00:00

  • Long-term effects of antilipidaemic therapy on left ventricular function in patients with dyslipidaemia: multigated radionuclide ventriculography study.

    abstract:AIM:It has been reported that dyslipidaemia impairs left ventricular systolic (LVs) and diastolic (LVd) functions, irrespective of atherogenic effects, in the setting of coronary artery disease. The aim of the present study was to evaluate the effects of anti-lipidaemic therapy on LVs and LVd functions by means of mult...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.mnm.0000172740.98369.ed

    authors: Entok E,Unalir A,Cavusoglu Y,Timuralp B,Vardareli E

    更新日期:2005-09-01 00:00:00

  • Correlation of radiation dose and activity with clinical outcomes in metastatic colorectal cancer after selective internal radiation therapy using yttrium-90 resin microspheres.

    abstract:PURPOSE:Yttrium-90 (Y)-resin microspheres are prescribed using activity. We evaluated overall survival (OS) and radiographic tumor response after selective internal radiation therapy (SIRT) with resin microspheres in patients with liver metastases from colorectal cancer. PATIENTS AND METHODS:We retrospectively reviewe...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000887

    authors: Badiyan S,Bhooshan N,Chuong MD,Sharma N,Akhter N,Etezadi V,Hausner P,Kudryasheva S,Kaiser A,Becker S,Guerrero M,Yi BY

    更新日期:2018-10-01 00:00:00

  • Prospective evaluation of the negative predictive value of V/Q SPECT using 99mTc-Technegas.

    abstract:OBJECTIVE:To verify the negative predictive value of pulmonary ventilation/perfusion scintigraphy with single photon emission computed tomography (V/Q SPECT) in ruling out pulmonary thromboembolism. METHODS:V/Q SPECT using 99mTc-Technegas was performed on 584 patients to rule out pulmonary thromboembolism between Octo...

    journal_title:Nuclear medicine communications

    pub_type: 临床试验,杂志文章

    doi:10.1097/MNM.0b013e32827a8e99

    authors: Leblanc M,Leveillée F,Turcotte E

    更新日期:2007-08-01 00:00:00

  • The value of syringe shields in a nuclear medicine department.

    abstract::The radiation dose to the pulp of both index fingers has been measured in a radiopharmacy supplying 11 000 patient doses a year, in a hospital dispensary (4500 doses a year) and in its injection area. Tungsten syringe shields were used for one week and not used during the other week. In the radiopharmacy and the dispe...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-198508000-00004

    authors: Harding LK,Hesslewood S,Ghose SK,Thomson WH

    更新日期:1985-08-01 00:00:00

  • Myocardial perfusion imaging versus biochemical markers in acute coronary syndromes.

    abstract::The assessment and appropriate clinical management of patients with acute chest pain and non-diagnostic electrocardiograms remain a continuing clinical problem. Accordingly, there is considerable interest in evaluating new strategies to improve early diagnostic accuracy in patients with possible acute myocardial ischa...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/00006231-200310000-00004

    authors: Anand DV,Lahiri A

    更新日期:2003-10-01 00:00:00

  • Specifying dual-detector gamma cameras and associated computer systems.

    abstract::Increasingly, dual-detector gamma cameras are being purchased as replacements for single-headed cameras. The improvement in sensitivity offered by a dual-detector device can be used in several ways: to shorten acquisition times, to improve signal-to-noise ratios, or to reduce administered doses. This paper focuses on ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章,评审

    doi:10.1097/00006231-199507000-00003

    authors: Tindale WB

    更新日期:1995-07-01 00:00:00

  • Excretion and whole-body retention of radium-223 dichloride administered for the treatment of bone metastases from castration resistant prostate cancer.

    abstract:OBJECTIVE:The aim of the study was to determine the fraction of administered activity that was excreted and retained by a small cohort of patients who each received treatment with radium-223 dichloride (Ra). Ra is an α-emitting radionuclide that has been approved for use in the treatment of bone metastases that are sec...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/MNM.0000000000000783

    authors: Pratt BE,Hindorf C,Chittenden SJ,Parker CC,Flux GD

    更新日期:2018-02-01 00:00:00

  • Right ventricular thallium-201 visualization in hypertrophic cardiomyopathy.

    abstract::Fifty-six patients with hypertrophic cardiomyopathy who had echocardiography and cardiac catheterization were studied. Eleven (18%) of 56 patients had right ventricular (RV) thallium-201 visualization at resting scan. RV thallium-201 visualization was observed in the apex or lower half of the RV free wall, which was q...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:

    authors: Nishimura T,Uehara T,Hayashida K,Nagata S

    更新日期:1988-01-01 00:00:00

  • 99mTcN complexes of tert-butyl dithiocarbamate and methoxyisobutyl dithiocarbamate as myocardial and brain imaging agents.

    abstract:OBJECTIVE:Two ligands viz. tert-butyl dithiocarbamate (TBDTC) and methoxyisobutyl dithiocarbamate (MIBDTC), which are analogous to the tert-butyl isonitrile (TBI) and sestamibi (MIBI) ligands, were synthesized and labelled with the [99mTcN] core to evaluate their potential as myocardial agents. As these complexes have ...

    journal_title:Nuclear medicine communications

    pub_type: 杂志文章

    doi:10.1097/01.mnm.0000183793.51474.2f

    authors: Mathur A,Mallia MB,Subramanian S,Banerjee S,Kothari K,Dhotare B,Sarma HD,Venkatesh M

    更新日期:2005-11-01 00:00:00