Clinical trial of a noninvasive contact lens glucose sensor.

Abstract:

OBJECTIVE:The purpose of the present study was to determine the effectiveness of a fluorescent contact lens glucose sensor in monitoring glucose in patients with diabetes. METHODS:Under an institutional review board-approved protocol, five fasting patients with type II diabetes were given a challenge consisting of 75 mL of Sustacal (Thomson Micromedex, Greenwood, CO) by mouth. Contact lens fluorescence and venous blood glucose were measured over a 3-h period. RESULTS:Contact lens fluorescence appeared to track blood glucose well. The fluorescent daily-wear disposable contact lenses were comfortable and were tolerated well, even in patients who had not previously worn contact lenses. CONCLUSION:The contact lens glucose sensor shows promise as a home glucose monitor.

journal_name

Diabetes Technol Ther

authors

March WF,Mueller A,Herbrechtsmeier P

doi

10.1089/dia.2004.6.782

keywords:

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

782-9

issue

6

eissn

1520-9156

issn

1557-8593

journal_volume

6

pub_type

临床试验,杂志文章
  • Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use.

    abstract:BACKGROUND:The recent availability of a continuous glucose monitor offers the opportunity to match the demands of intensive diabetes management with a period of equally intensive blood glucose monitoring. The present study evaluates the performance of the MiniMed continuous glucose monitoring system (CGMS) in patients ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091500316737

    authors: Gross TM,Bode BW,Einhorn D,Kayne DM,Reed JH,White NH,Mastrototaro JJ

    更新日期:2000-04-01 00:00:00

  • Prevalence of Diabetic Neuropathy in Young Adults with Type 1 Diabetes and the Association with Insulin Pump Therapy.

    abstract:AIMS:The aim was to investigate the prevalence of diabetic sensorimotor polyneuropathy (DSPN) and cardiovascular autonomic neuropathy (CAN) in a Danish population of young adults with type 1 diabetes (T1D) using both established and novel measuring modalities. Furthermore, to investigate the association between continu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0249

    authors: Christensen MMB,Hommel EE,Jørgensen ME,von Scholten BJ,Fleischer J,Hansen CS

    更新日期:2018-11-21 00:00:00

  • Factors associated with persistence and resumption of insulin pen use for patients with type 2 diabetes.

    abstract:OBJECTIVE:this study assessed patient-related factors associated with persistence and resumption of using pens as insulin delivery devices. METHODS:patients (n = 549; 300 current pen users, 249 former pen users) were recruited from national panels to participate in computer-assisted telephone interviews. Measures incl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2010.0128

    authors: Peyrot M,Rubin RR

    更新日期:2011-01-01 00:00:00

  • Limitations of the HOMA-B score for assessment of beta-cell functionality in interventional trials-results from the PIOglim study.

    abstract:BACKGROUND:Drugs with unspecific stimulating effects on beta-cell secretion increase the homeostasis model assessment (HOMA)-B score, indicating improved beta-cell "function." We investigated whether the beta-cell protection provided by adding pioglitazone (PIO) to glimepiride (GLIM) in comparison to up-titrating the G...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2010.0019

    authors: Pfützner A,Derwahl M,Jacob S,Hohberg C,Blümner E,Lehmann U,Fuchs W,Forst T

    更新日期:2010-08-01 00:00:00

  • Evaluation of a Nurse-Managed Insulin Infusion Protocol.

    abstract:BACKGROUND:The purpose of this study was to evaluate the performance of an insulin infusion protocol targeting a blood glucose (BG) level of 140-180 mg/dL and to characterize protocol adherence. MATERIALS AND METHODS:This was a retrospective observational cohort study including patients for whom the protocol was order...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2015.0046

    authors: Passarelli AJ,Gibbs H,Rowden AM,Efird L,Zink E,Mathioudakis N

    更新日期:2016-02-01 00:00:00

  • Advanced meter features improve postprandial and paired self-monitoring of blood glucose in individuals with diabetes: results of the Actions with the CONTOUR Blood Glucose Meter and Behaviors in Frequent Testers (ACT) study.

    abstract:BACKGROUND:This study evaluated whether education and use of the advanced meter features of the CONTOUR(®) (Bayer HealthCare LLC, Diabetes Care, Tarrytown, NY) blood glucose monitoring system (BGMS) affect the frequency and pattern of blood glucose testing in insulin-using subjects with diabetes who routinely perform s...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2012.0051

    authors: Bergenstal RM,Bode BW,Tamler R,Trence DL,Stenger P,Schachner HC,Fullam J,Pardo S,Kohut T,Fisher WA

    更新日期:2012-10-01 00:00:00

  • The association of self-monitoring of blood glucose use with medication adherence and glycemic control in patients with type 2 diabetes initiating non-insulin treatment.

    abstract:BACKGROUND:The value of self-monitoring of blood glucose (SMBG) for persons with type 2 diabetes who do not use insulin remains controversial. This observational study compares the likelihood of medication adherence and change in glycated hemoglobin (A1C) for non-insulin-using patients using SMBG versus those not using...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2012.0047

    authors: Virdi N,Daskiran M,Nigam S,Kozma C,Raja P

    更新日期:2012-09-01 00:00:00

  • Comparison of Second-Generation Basal Insulin Analogs: A Review of the Evidence from Continuous Glucose Monitoring.

    abstract::Many people with insulin-treated diabetes continue to experience inadequate glycemic control and a high incidence of hypoglycemic events, despite improvements in therapeutic strategies. While glycated hemoglobin (HbA1c) is currently recognized as the gold-standard for assessing glycemic control, the measure reflects m...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2020.0180

    authors: Battelino T,Edelman SV,Nishimura R,Bergenstal RM

    更新日期:2021-01-01 00:00:00

  • Safety and Performance of the Omnipod Hybrid Closed-Loop System in Adults, Adolescents, and Children with Type 1 Diabetes Over 5 Days Under Free-Living Conditions.

    abstract:: Background: The objective of this study was to assess the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm in adults, adolescents, and children aged ≥6 years with type 1 diabetes (T1D) under free-living conditions using an invest...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1089/dia.2019.0286

    authors: Sherr JL,Buckingham BA,Forlenza GP,Galderisi A,Ekhlaspour L,Wadwa RP,Carria L,Hsu L,Berget C,Peyser TA,Lee JB,O'Connor J,Dumais B,Huyett LM,Layne JE,Ly TT

    更新日期:2020-03-01 00:00:00

  • Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring.

    abstract:BACKGROUND:Currently, two systems for continuous tissue glucose monitoring (CGM) (Dexcom® G5 [DG5] and FreeStyle Libre [FL]) are intended to replace blood glucose monitoring (BGM) and, according to manufacturer labeling, are distributed as such in some jurisdictions, including the United States and the European Union. ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0105

    authors: Freckmann G,Link M,Pleus S,Westhoff A,Kamecke U,Haug C

    更新日期:2018-08-01 00:00:00

  • Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    abstract:BACKGROUND:Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. METHODS:We evaluated 21 individuals with type 1 diabetes using a capillary calibra...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2017.0189

    authors: Kropff J,van Steen SC,deGraaff P,Chan MW,van Amstel RBE,DeVries JH

    更新日期:2017-11-01 00:00:00

  • Perioperative Characteristics of the Accuracy of Subcutaneous Continuous Glucose Monitoring: Pilot Study in Neurosurgery and Cardiac Surgery.

    abstract:BACKGROUND:The aim of this study was to elucidate the characteristics of accuracy of subcutaneous continuous glucose monitoring (SCGM) in the perioperative period for neurosurgical and cardiac surgery patients. METHODS:Forty-five subjects, including healthy volunteers (n = 15), neurosurgical patients (n = 15), and car...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2018.0140

    authors: Sugiyama Y,Wakabayashi R,Urasawa M,Maruyama Y,Shimizu S,Kawamata M

    更新日期:2018-10-01 00:00:00

  • Efficacy and Safety of Biosimilar SAR342434 Insulin Lispro in Adults with Type 1 Diabetes Also Using Insulin Glargine-SORELLA 1 Study.

    abstract:BACKGROUND:SAR342434 is a biosimilar follow-on of insulin lispro-Humalog®. This study aimed to show similar efficacy, safety, and immunogenicity of SAR342434 (SAR-Lis) versus insulin lispro-Humalog (Ly-Lis) in adult patients with type 1 diabetes (T1DM) treated with multiple daily injections while using basal insulin gl...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2017.0117

    authors: Garg SK,Wernicke-Panten K,Rojeski M,Pierre S,Kirchhein Y,Jedynasty K

    更新日期:2017-09-01 00:00:00

  • Accuracy of glycemic measurements in the critically ill.

    abstract:BACKGROUND:Recent evidence emphasizes the importance of maintaining normoglycemia in critically ill patients to reduce morbidity and mortality. Different analytical methods of varying accuracy exist for obtaining and measuring blood glucose in critically ill patients. The purpose of this study was to determine if there...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2008.0263

    authors: Slater-MacLean L,Cembrowski G,Chin D,Shalapay C,Binette T,Hegadoren K,Newburn-Cook C

    更新日期:2008-06-01 00:00:00

  • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours.

    abstract:BACKGROUND:This study assessed the feasibility of a portable bihormonal closed-loop system at home. SUBJECTS AND METHODS:Sixteen pump-treated patients with type 1 diabetes received 48 h of closed-loop therapy with a telemonitored insulin- and glucagon-delivering closed-loop system and 48 h of patient-managed open-loop...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0166

    authors: van Bon AC,Luijf YM,Koebrugge R,Koops R,Hoekstra JB,DeVries JH

    更新日期:2014-03-01 00:00:00

  • The effect of capsule composition in the reversal of hyperglycemia in diabetic mice transplanted with microencapsulated allogeneic islets.

    abstract::The transplantation of microencapsulated islets may allow reversal of hyperglycemia in the absence of immunosuppression. Poly-L-lysine (PLL) on capsules may potentiate the fibrotic reaction against implanted capsules. The aims of this study were to investigate how the biocompatibility of such capsules affects their fu...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/152091503322250677

    authors: King A,Lau J,Nordin A,Sandler S,Andersson A

    更新日期:2003-01-01 00:00:00

  • Metrics to Evaluate Quality of Glycemic Control: Comparison of Time in Target, Hypoglycemic, and Hyperglycemic Ranges with "Risk Indices".

    abstract:OBJECTIVE:We sought to cross validate several metrics for quality of glycemic control, hypoglycemia, and hyperglycemia. RESEARCH DESIGN AND METHODS:We analyzed the mathematical properties of several metrics for overall glycemic control, and for hypo- and hyperglycemia, to evaluate their similarities, differences, and ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0416

    authors: Rodbard D

    更新日期:2018-05-01 00:00:00

  • High Glucose Variability in Hospitalized Patients with Type 1 Diabetes Mellitus.

    abstract:BACKGROUND:Glucose variability (GV) has been increasingly (or more extensively) studied in patients with type 1 diabetes (T1D) in the ambulatory setting; limited data exist on GV in hospitalized patients with T1D. MATERIALS AND METHODS:Retrospective single center cohort study, we analyzed in-hospital glucose measureme...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2017.0107

    authors: Dadlani V,Tamhane SU,Sun A,Sharma A,Delivanis DA,Thapa P,Carter RE,Kudva YC

    更新日期:2017-10-01 00:00:00

  • Development of a Collaborative Algorithm for the Management of Type 2 Diabetes during Ramadan: An Anchor on Empowerment.

    abstract::Empowerment plays significant roles in the complex management of type 2 diabetes. International guidelines have provided recommendations on management of Muslims who fast during Ramadan. However, there remains a lack of patient-centered epistemic tool to empower healthcare providers and patients in managing diabetes d...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2018.0159

    authors: Lum ZK,See Toh WY,Lim SM,Rusli KDB,Abdul Shakoor SAKK,Tsou KYK,Chew DEK,Dalan R,Kwek SC,Othman N,Lian JX,Lee JY

    更新日期:2018-10-01 00:00:00

  • Improved Postprandial Glycemic Control with Faster-Acting Insulin Aspart in Patients with Type 1 Diabetes Using Continuous Subcutaneous Insulin Infusion.

    abstract:BACKGROUND:Faster aspart is insulin aspart (IAsp) in a new formulation, which in continuous subcutaneous insulin infusion (CSII) in subjects with type 1 diabetes has shown a faster onset and offset of glucose-lowering effect than IAsp. METHODS:This double-blind, randomized, crossover active-controlled trial compared 2...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/dia.2016.0350

    authors: Bode BW,Johnson JA,Hyveled L,Tamer SC,Demissie M

    更新日期:2017-01-01 00:00:00

  • The Value of Automated Diabetic Retinopathy Screening with the EyeArt System: A Study of More Than 100,000 Consecutive Encounters from People with Diabetes.

    abstract:: Background: Current manual diabetic retinopathy (DR) screening using eye care experts cannot scale to screen the growing population of diabetes patients who are at risk for vision loss. EyeArt system is an automated, cloud-based artificial intelligence (AI) eye screening t...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2019.0164

    authors: Bhaskaranand M,Ramachandra C,Bhat S,Cuadros J,Nittala MG,Sadda SR,Solanki K

    更新日期:2019-11-01 00:00:00

  • Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

    abstract::Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have be...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2017.0054

    authors: Schnell O,Barnard K,Bergenstal R,Bosi E,Garg S,Guerci B,Haak T,Hirsch IB,Ji L,Joshi SR,Kamp M,Laffel L,Mathieu C,Polonsky WH,Snoek F,Home P

    更新日期:2017-07-01 00:00:00

  • The use of continuous glucose monitoring in patients with type 2 diabetes.

    abstract::Since the late 1970s, self-monitoring of blood glucose has been the standard for assessing daily glycemic control. The first continuous glucose monitor became available in 1999. Numerous clinical trials have documented the benefits of continuous glucose monitoring (CGM) in patients with type 1 diabetes mellitus (DM). ...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,评审

    doi:10.1089/dia.2011.0086

    authors: Meade LT

    更新日期:2012-02-01 00:00:00

  • Reduced weight gain with insulin detemir compared to NPH insulin is not explained by a reduction in hypoglycemia.

    abstract:BACKGROUND:Weight gain often occurs when insulin therapy is initiated. The long-acting insulin analog insulin detemir has been shown to be effective and well tolerated when used in basal-bolus regimens or as an add-on to oral antidiabetic drugs (OADs) and causes less weight gain than other insulins. The aim of this exp...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2008.0282

    authors: Davies MJ,Derezinski T,Pedersen CB,Clauson P

    更新日期:2008-08-01 00:00:00

  • Continuous subcutaneous insulin infusion and multiple dose of insulin regimen display similar patterns of blood glucose excursions in pediatric type 1 diabetes.

    abstract:BACKGROUND:Continuous subcutaneous insulin infusion (CSII) is believed to decrease glycemic variability and clinical hypoglycemia compared with the multiple daily insulin (MDI) regimen. To compare the indices of glycemic instability between CSII and MDI, we analyzed the continuous glucose monitoring system (CGMS) (Medt...

    journal_title:Diabetes technology & therapeutics

    pub_type: 临床试验,杂志文章

    doi:10.1089/dia.2005.7.587

    authors: Alemzadeh R,Palma-Sisto P,Parton EA,Holzum MK

    更新日期:2005-08-01 00:00:00

  • Is the masked continuous glucose monitoring system clinically useful for predicting hemoglobin A1C in type 1 diabetes?

    abstract:BACKGROUND:The masked continuous glucose monitoring system (Masked-CGMS) differs from standard CGMSs in three ways: (1) there is no feedback to the user so that no immediate regimen changes can be made; (2) it can only be worn for up to 5 days; and (3) there are no alarms to warn of hyperglycemia or hypoglycemia. Since...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2013.0297

    authors: Duran-Valdez E,Burge MR,Broderick P,Shey L,Valentine V,Schrader R,Schade DS

    更新日期:2014-05-01 00:00:00

  • Factors Affecting Recruitment of Participants for Studies of Diabetes Technology in Newly Diagnosed Youth with Type 1 Diabetes: A Qualitative Focus Group Study with Parents and Children.

    abstract:BACKGROUND:Relatively little is known about parents' or children's attitudes toward recruitment for, and participation in, studies of new diabetes technologies immediately after diagnosis. This study investigated factors affecting recruitment of participants for studies in newly diagnosed youth with type 1 diabetes. M...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2016.0157

    authors: Farrington C,Allen J,Tauschmann M,Randell T,Trevelyan N,Hovorka R

    更新日期:2016-09-01 00:00:00

  • Predicting the effectiveness of insulin pump therapy on glycemic control in clinical practice: a retrospective study of patients with type 1 diabetes from 10 outpatient diabetes clinics in Sweden over 5 years.

    abstract:BACKGROUND:Multicenter long-term studies of predictors for the effectiveness of continuous subcutaneous insulin infusion (CSII) in clinical practice are lacking. We hypothesized that there are substantially greater reductions in hemoglobin A1c (HbA1c) in patients with poor glycemic control and that other predictors may...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2014.0139

    authors: Clements M,Matuleviciene V,Attvall S,Ekelund M,Pivodic A,Dahlqvist S,Fahlén M,Haraldsson B,Lind M

    更新日期:2015-01-01 00:00:00

  • Enzymatic fluorescent microsphere glucose sensors:evaluation of response under dynamic conditions.

    abstract::Most previous attempts at the development of a "smart tattoo" for glucose monitoring in diabetes--implantable fluorescent microspheres that can be implanted intradermally and interrogated transdermally using light--have focused on the encapsulation of a competitive binding assay for glucose within hydrogel microsphere...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章

    doi:10.1089/dia.2006.8.288

    authors: Brown JQ,Srivastava R,Zhu H,McShane MJ

    更新日期:2006-06-01 00:00:00

  • Assessment of a new insulin preparation for implanted pumps used in the treatment of type 1 diabetes.

    abstract:BACKGROUND:Implanted insulin pumps using the peritoneal route provide long-term improvement of glucose control compared with subcutaneous insulin therapy in type 1 diabetes (T1D) patients. The stability of insulin preparation is critical for a safe use in implanted pumps. Insuman implantable(®) (400 IU/mL) (Sanofi-Aven...

    journal_title:Diabetes technology & therapeutics

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1089/dia.2013.0369

    authors: Schaepelynck P,Riveline JP,Renard E,Hanaire H,Guerci B,Baillot-Rudoni S,Sola-Gazagnes A,Catargi B,Fontaine P,Millot L,Martin JF,Tachouaft H,Jeandidier N,EVADIAC Group.

    更新日期:2014-09-01 00:00:00