Abstract:
:The paper gives a bibliographical review of the finite element modelling and simulations in dentistry from the theoretical as well as practical points of view. The bibliography lists references to papers, conference proceedings and theses/dissertations that were published between 1990 and 2003. At the end of this paper, more than 700 references are given dealing with subjects such as: dental materials; oral and maxillofacial mechanics and surgery; orthodontics, tooth movement, orthodontic appliances; root canals, filling and therapy; dental restorations and other topics.
journal_name
Comput Methods Biomech Biomed Enginauthors
Mackerle Jdoi
10.1080/10255840412331309243keywords:
subject
Has Abstractpub_date
2004-10-01 00:00:00pages
277-303issue
5eissn
1025-5842issn
1476-8259pii
JT54ERLW53U1GA3Tjournal_volume
7pub_type
abstract::Musculoskeletal finite element analysis (FEA) has been essential to research in orthopaedic biomechanics. The generation of a volumetric mesh is often the most challenging step in a FEA. Hexahedral meshing tools that are based on a multi-block approach rely on the manual placement of building blocks for their mesh gen...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2010.499869
更新日期:2011-10-01 00:00:00
abstract::Most of musculoskeletal models (MSKM) estimate the tibiofemoral joint reaction load at a single point or do not support large lower-limb ranges. This study aimed to adapt a generic MSKM that allows large knee and hip flexions to compute medial and lateral tibiofemoral contact forces (TFCF) during gait and squat tasks....
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2020.1757662
更新日期:2020-08-01 00:00:00
abstract::Anterior percutaneous endoscopic cervical discectomy (APECD) is a common treatment for cervical spondylotic radiculopathy (CSR). In this study, the effects of various channel diameters and approach angles on cervical vertebrae on postoperative outcomes in APECD surgery were explored. A finite element model of intact c...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2020.1846186
更新日期:2020-12-01 00:00:00
abstract::This paper proposes a micromechanics algorithm utilising the finite element method (FEM) for the analysis of heterogeneous matter. The characterisation procedure takes the material properties of the constituents, axons and extracellular matrix (ECM) as input data. The material properties of both the axons and the matr...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840903097871
更新日期:2009-06-01 00:00:00
abstract::This paper is motivated by recent experimental research (Tang-Schomer et al. 2012) on the formation of periodic varicosities in axons after traumatic brain injury (TBI). TBI leads to the formation of undulated distortions in the axons due to their dynamic deformation. These distortions result in the breakage of some m...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2013.820721
更新日期:2015-01-01 00:00:00
abstract::Functional Alignment is a new method to determine the orientation of a joint's primary rotational axis and the associated movement. It employs three unique concepts. First, data analyses are based upon assessment of spatial positions and not upon movement in a time sequence. Second, analyses are conducted on derived j...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2010.545821
更新日期:2012-01-01 00:00:00
abstract::Soft tissue modelling has gained a great deal of importance, for a large part due to its application in surgical training simulators for minimally invasive surgery (MIS). This article provides a structured overview of different continuum-mechanical models that have been developed over the years. It aims at facilitatin...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章,评审
doi:10.1080/10255840802020412
更新日期:2008-08-01 00:00:00
abstract::The phenotype expression in X-linked adrenoleukodystrophy is one of the most intriguing issues of the disease, because there is no general correlation between the type of ABCD1 gene mutation and the clinical phenotype. In this study, we use the cross-impact analysis to build a descriptively quantitative relationship b...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840903279974
更新日期:2010-06-01 00:00:00
abstract::An approach was developed to evaluate the load transfer mechanism in the temporomandibular joint (TMJ) area before, during and after mandibular ramus elongation by distraction osteogenesis (DO). In a concerted approach using computer tomography, magnetic resonance imaging (MRI), and finite element analysis, three-dime...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840500237953
更新日期:2005-06-01 00:00:00
abstract::The mechanical properties of soft biological tissues in general and early stage engineered tissues in particular limit the feasibility of conventional tensile tests for their mechanical characterisation. Furthermore, the most important mode in development of deep tissue injury (DTI) is compression. Therefore, an inver...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840701771768
更新日期:2008-10-01 00:00:00
abstract::The aim of this work was to improve the constitutive model of the human mandible and dentition system by taking into account the non-linear material properties of the structural boney matrix that forms the human jaw bone or mandible. Due to the specific structure of the jaw bone the time dependence of the mechanical p...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840310001637257
更新日期:2003-10-01 00:00:00
abstract::Haemodynamics is believed to play an important role in the initiation, growth and rupture of intracranial aneurysms. In this context, computational haemodynamics has been extensively used in an effort to establish correlations between flow variables and clinical outcome. It is common practice in the application of Dir...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840802654335
更新日期:2009-08-01 00:00:00
abstract::The aim of this study was to investigate and present a new mapping method to describe muscle pain sensitivity based on the assessment of pressure pain threshold (PPT) over the trapezius muscle. PPT data were recorded from 36 points in 20 healthy males using a standardised grid. Points were clustered using the K-means ...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840903446979
更新日期:2010-12-01 00:00:00
abstract::Transcatheter aortic valve replacement (TAVR) strongly depends on the calcification patterns, which may lead to a malapposition of the stented valve and complication onsets in terms of structure kinematics and paravalvular leakage (PVL). From one anatomical-resembling model of the aortic root, six configurations with ...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2020.1817409
更新日期:2020-09-14 00:00:00
abstract::Complexity represents the adaptability of the biological system, therefore the assessment of complexity during tasks such as walking may be particularly useful when attempting to better understand the recovery processes after stroke. The purpose of this study was to determine whether the complexity of lower extremity ...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2019.1578961
更新日期:2019-05-01 00:00:00
abstract::Many methods developed for estimating the reliability of protein-protein interactions are based on the topology of protein-protein interaction networks. This paper describes a new reliability measure for protein-protein interactions, which does not rely on the topology of protein interaction networks, but expresses bi...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2010.494039
更新日期:2010-02-01 00:00:00
abstract::To analyze the biomechanical effect of syndesmotic screw through three and four cortices, a total of 12 finite element models simulating healthy ankles, tibiofibular syndesmosis injured ankles, and post-operative ankles by screw fixations through three or four cortices were built. A set of biomechanical data were obta...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2018.1472770
更新日期:2018-04-01 00:00:00
abstract::This article develops a two prion population model that simulates prion trafficking between an infected dendritic cell and a neuron. The situation when the two cells are connected by a tunnelling nanotube (TNT) is simulated. Two mechanisms of prion transport are considered: lateral diffusion in the TNT membrane and ac...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2013.763938
更新日期:2014-11-01 00:00:00
abstract::It is still unclear how a vertebral fracture should be stabilised and strengthened without endangering the remaining intact bone of the augmented vertebra or the adjacent vertebrae. Numerical modelling may provide insight. To date, however, few finite element (FE) spine models have been developed which are both multi-...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2010.522183
更新日期:2012-01-01 00:00:00
abstract::In the present study, the free fall impact test in accordance with the EN1078 standard for certification of bicycle helmets is replicated using numerical simulations. The impact scenario is simulated using an experimentally validated, patient-specific head model equipped with and without a bicycle helmet. Head acceler...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2018.1511775
更新日期:2018-09-01 00:00:00
abstract::Fretting and corrosion at the taper-head interface in total hip arthroplasty has been reported as a potential cause of early failure of the implant system. The finite element (FE) method can be used to study the mechanics at the taper junction that are difficult to assess experimentally. Taper mismatch is one of the f...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2019.1627524
更新日期:2019-10-01 00:00:00
abstract::Blunt and rotational head impacts due to vehicular collisions, falls and contact sports cause relative motion between the brain and skull. This increases the normal and shear stresses in the (skull/brain) interface region consisting of cerebrospinal fluid (CSF) and subarachnoid space (SAS) trabeculae. The relative mot...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255840903064897
更新日期:2009-02-01 00:00:00
abstract::A critical point in models of the human limbs when the aim is to investigate the motor control is the muscle model. More often the mechanical output of a muscle is considered as one musculotendon force that is a design variable in optimization tasks solved predominantly by static optimization. For dynamic conditions, ...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/1025584031000149097
更新日期:2003-06-01 00:00:00
abstract::Pelvic disorders can be associated with changes in the biomechanical properties in the muscle, ligaments and/or connective tissue form fascia and ligaments. In this sense, the study of their mechanical behavior is important to understand the structure and function of these biological soft tissues. The aim of this stud...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2017.1304542
更新日期:2017-06-01 00:00:00
abstract::Woodpeckers can withstand a fierce impact during pecking without any brain injury. Although directly involved in the whole pecking, the role of the jaw apparatus played in the impact-resistant process of woodpeckers is still not fully clear. We employed finite element analysis, impact tests in vivo, and post-traumatic...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2020.1838489
更新日期:2021-01-13 00:00:00
abstract::The change in maximum total point motion (ΔMTPM) is used to predict long-term risk of tibial baseplate loosening, however, effects of registration error on ΔMTPM have not been quantified for marker-based and model-based radiostereometric analysis (RSA). Registration errors for marker-based and model-based RSA were app...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2020.1865324
更新日期:2021-01-05 00:00:00
abstract::The purpose of this study was to create and validate a standardized framework for the evaluation of the ankle stiffness of two designs of 3D printed ankle foot orthoses (AFOs). The creation of four finite element (FE) models allowed patient-specific quantification of the stiffness and stress distribution over their sp...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2019.1601712
更新日期:2019-06-01 00:00:00
abstract::Biomechanical imaging techniques have been developed for soft tissue characterisation and detection of breast tumours. Harmonic motion imaging (HMI) uses a focused ultrasound technology to generate a harmonic radiation force in a localised region inside a soft tissue. The resulting dynamic response is used to map the ...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2012.736500
更新日期:2014-01-01 00:00:00
abstract::Remodelling and adaptation of bone within the pelvis is believed to be influenced by the mechanical strains generated during locomotion. Variation in the cortical bone thickness observed in the prenatal ilium has been linked to the musculoskeletal loading associated with in utero movements; for example the development...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2020.1777546
更新日期:2020-10-01 00:00:00
abstract::Human brain tissue is complex and multi-component in nature. It consists of an anisotropic hyperelastic solid material composed of tissue cells and blood vessel walls. Brain tissue is permeated by two viscous pore liquids, the interstitial fluid and the blood. Both liquids are mobile within the tissue and exhibit a si...
journal_title:Computer methods in biomechanics and biomedical engineering
pub_type: 杂志文章
doi:10.1080/10255842.2013.853754
更新日期:2015-01-01 00:00:00