Abstract:
:Although multimemory hearing aids have theoretical advantages over conventional "single memory" hearing aids, research and clinical data are not available to support their efficacy. The present study reports on the usefulness of a commercially available multimemory hearing aid in daily listening situations. Nineteen elderly hearing-aid wearers were fitted with the Quattro Q8 hearing aid. A modified Simplex procedure was used to select the electroacoustic characteristics for each memory. Subjects wore the device home and reported their satisfaction with each memory on the hearing aid in different listening situations. Their impressions on the whole hearing aid and on the remote feature were also sampled. Although a majority of subjects showed preference for multimemory design, such observations may not be readily evident until after extended use of the device. Inconvenience and cost of the device may prohibit some hearing-impaired listeners from using the device.
journal_name
J Am Acad Audioljournal_title
Journal of the American Academy of Audiologyauthors
Kuk FKkeywords:
subject
Has Abstractpub_date
1992-09-01 00:00:00pages
338-48issue
5eissn
1050-0545issn
2157-3107journal_volume
3pub_type
杂志文章abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract::The literature suggests that directional microphone hearing aids (DMHAs) are a viable means for improving the signal-to-noise ratio (SNR) for hearing-impaired listeners. The amount of directional advantage they provide, however, remains relatively unclear because of variability observed among individual studies. The p...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,meta分析
doi:
更新日期:2001-04-01 00:00:00
abstract::The Gaps-In-Noise (GIN) test is a new procedure used in the diagnosis of central auditory processing disorders. Performance on the GIN is recorded as approximate gap detection threshold and percent correct. In order to utilize the GIN test clinically, it is important to know how presentation level influences performan...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18.2.6
更新日期:2007-02-01 00:00:00
abstract:BACKGROUND:Passive electrophysiological protocols, such as the middle latency response and speech auditory brainstem response, are often advocated in the objective assessment of central auditory processing disorder (CAPD). However, few established electrophysiological protocols exist for CAPD assessment that have patie...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17047
更新日期:2019-06-01 00:00:00
abstract:BACKGROUND:Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15005
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND:Binaural hearing improves our ability to understand speech and to localize sounds. Hearing loss can interfere with binaural cues, and despite the success of amplification, ∼25% of people with bilateral hearing loss fit with two hearing aids choose to wear only one (e.g., Brooks and Bulmer, 1981). One explana...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.22.3.6
更新日期:2011-03-01 00:00:00
abstract::The binaural interaction component (BIC) of the auditory brainstem response (ABR) and BIC of the frequency-following response (FFR) to tonal stimuli were studied in normal-hearing adults. The ABR and BIC latencies from all subjects were consistently shorter to the click-like sound than to the 2.0 kHz tone burst. Incre...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-07-01 00:00:00
abstract:BACKGROUND:The middle latency response (MLR) first came to light as an auditory evoked potential in 1958. Since then, it has aroused substantial interest and investigation by clinicians and researchers alike. In recent history, its use and popularity have dwindled in tandem with various other auditory evoked potentials...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16141
更新日期:2018-10-01 00:00:00
abstract::A Macintosh computer-based audiometer (Virtual 320) was evaluated for reliability and validity of high-frequency (8-20 kHz) thresholds by comparison with a well documented laboratory high-frequency evaluation system (PARVA-HF). High-frequency earphones originally provided with the V320 for high-frequency testing requi...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1990-07-01 00:00:00
abstract::This is the second in a series of two papers on masking. The objective of these papers is to develop a masking protocol that provides valid measures of threshold and is, in general, faster than the plateau method. In the first paper, a masking method was presented that can replace the traditional plateau method in mos...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15.1.5
更新日期:2004-01-01 00:00:00
abstract::The present investigation was conducted to help determine whether source activity of the direct recorded N1 response differed from that of the gamma band response (GBR). Auditory evoked cortical potential data from two patients with intractable epilepsy undergoing prolonged video EEG monitoring after implantation of s...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1999-07-01 00:00:00
abstract::In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.23.6.2
更新日期:2012-06-01 00:00:00
abstract::Electrocochleography (ECochG) has evolved as an important tool in the diagnosis/assessment/monitoring of Ménière's disease/endolymphatic hydrops (MD/ELH). This manuscript provides an update on the use of ECochG for these purposes. The material presented includes descriptions of the components of the electrocochleogram...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:10.3766/jaaa.17.1.6
更新日期:2006-01-01 00:00:00
abstract::We examined the ability of 40 young children (aged five to eight) to understand speech (monosyllables, spondees, trochees, and trisyllables) when listening in a background of real-life classroom noise. All children had some difficulty understanding speech when the noise was at levels found in many classrooms (i.e., 65...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15.7.5
更新日期:2004-07-01 00:00:00
abstract:BACKGROUND:Motivational interviewing (MI) has been used in consultation settings to motivate hearing aid users to increase hearing aid usage. However, the effect of MI on those who use their hearing aids only rarely or not at all has not been explored. PURPOSE:The aims of this pilot study were to evaluate the effect o...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16184
更新日期:2018-09-01 00:00:00
abstract::This review of the literature on Alport syndrome (AS) places emphasis on genetic and clinical issues related to the sensorineural hearing loss in type III and type IV X-linked AS. The review covers prevalence, medical issues, genetic issues, audiologic findings, vestibular findings, the pathophysiology of hearing loss...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,评审
doi:
更新日期:1995-01-01 00:00:00
abstract:BACKGROUND:Various methods have been used to measure temporal-fine-structure (TFS) sensitivity in hearing-impaired (HI) listeners. A new method called TFS-adaptive frequency (TFS-AF) test, tracks the highest frequency up to which a person can detect a given interaural phase difference (IPD) in bursts of pure tones. So ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.18068
更新日期:2020-02-01 00:00:00
abstract:BACKGROUND:Auditory-evoked potentials (EPs) provide a more objective assessment of central auditory nervous system (CANS) dysfunction when compared to behavioral measures because they do not require a behavioral response (Anderson and Kraus, 2010). In this regard, the middle latency response (MLR) has been considered a...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.4.4
更新日期:2014-04-01 00:00:00
abstract::This study assessed speech perception benefits for three congenitally deaf adolescents who used an electrotactile speech processor (Tickle Talker(TM)) and subsequently went on to use a Nucleus Minisystem 22 cochlear implant. Both devices provided significant and comparable benefits for all children in the device plus ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1996-04-01 00:00:00
abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract::There have been scattered accounts reported in the oncology literature of progressive hearing loss following the conclusion of chemotherapy. In this case study, we report the audiologic findings of such a case. These data underscore the need for post-therapy monitoring in cases where threshold shifts are discovered du...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1993-11-01 00:00:00
abstract:PURPOSE:To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and valid...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.20.5.3
更新日期:2009-05-01 00:00:00
abstract:BACKGROUND:Prior to undergoing vestibular function testing, it is not uncommon for clinicians to request that patients abstain from caffeine 24 hr prior to the administration of the tests. However, there is little evidence that caffeine affects vestibular function. PURPOSE:To evaluate whether the results from two test...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.25.3.5
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章,随机对照试验
doi:10.3766/jaaa.17135
更新日期:2019-05-01 00:00:00
abstract:BACKGROUND:The compound action potential (CAP) has been suggested in the literature as an alternative to otoacoustic emissions for evaluating the efferent auditory system. However, very few studies have examined efferent influence on auditory nerve potentials in humans. PURPOSE:This study examines the effects of prese...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.15002
更新日期:2016-02-01 00:00:00
abstract::Crystal Device Integrity Testing System (CITS), the first commercially available testing system of its type, allows rapid assessment of cochlear implant function by measuring averaged electrode voltages-the scalp-recorded fields generated by electrode currents. We describe our experience performing routine integrity t...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.17.10.4
更新日期:2006-11-01 00:00:00
abstract::Although it has been reported that smoking has deleterious effects on the middle ears of smokers, including their eustachian tubes, investigators have failed to find differences in the tympanometric characteristics of smokers and nonsmokers. In the present study, however, we found that the Valsalva-induced tympanometr...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1997-08-01 00:00:00
abstract::Draft American National Standard "Evaluating the Effectiveness of Hearing Conservation Programs" identifies potentially important links between audiometric threshold variability outcomes and occupational hearing conservation program (HCP) practices. Unacceptable threshold variability in annual audiograms may identify ...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:
更新日期:1995-11-01 00:00:00
abstract:BACKGROUND:The scalp-recorded frequency-following response (FFR) has been widely accepted in assessing the brain's processing of speech stimuli for people who speak tonal and nontonal languages. Characteristics of scalp-recorded FFRs with increasing number of sweeps have been delineated through the use of an exponentia...
journal_title:Journal of the American Academy of Audiology
pub_type: 杂志文章
doi:10.3766/jaaa.16135
更新日期:2018-02-01 00:00:00