Evaluation of the efficacy of a multimemory hearing aid.

Abstract:

:Although multimemory hearing aids have theoretical advantages over conventional "single memory" hearing aids, research and clinical data are not available to support their efficacy. The present study reports on the usefulness of a commercially available multimemory hearing aid in daily listening situations. Nineteen elderly hearing-aid wearers were fitted with the Quattro Q8 hearing aid. A modified Simplex procedure was used to select the electroacoustic characteristics for each memory. Subjects wore the device home and reported their satisfaction with each memory on the hearing aid in different listening situations. Their impressions on the whole hearing aid and on the remote feature were also sampled. Although a majority of subjects showed preference for multimemory design, such observations may not be readily evident until after extended use of the device. Inconvenience and cost of the device may prohibit some hearing-impaired listeners from using the device.

journal_name

J Am Acad Audiol

authors

Kuk FK

keywords:

subject

Has Abstract

pub_date

1992-09-01 00:00:00

pages

338-48

issue

5

eissn

1050-0545

issn

2157-3107

journal_volume

3

pub_type

杂志文章
  • Prescriptive hearing aid fitting by parameter adjustment and selection.

    abstract::We describe the rationale for the development of a psychophysical procedure that allows individual listeners to adjust the frequency-gain characteristic of a programmable hearing aid on a unidimensional scale, based on a target-gain reference value. The listener's task is to adjust the frequency response and select th...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Punch JL,Robb R

    更新日期:1992-03-01 00:00:00

  • Efficacy of directional microphone hearing aids: a meta-analytic perspective.

    abstract::The literature suggests that directional microphone hearing aids (DMHAs) are a viable means for improving the signal-to-noise ratio (SNR) for hearing-impaired listeners. The amount of directional advantage they provide, however, remains relatively unclear because of variability observed among individual studies. The p...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,meta分析

    doi:

    authors: Amlani AM

    更新日期:2001-04-01 00:00:00

  • The effect of presentation level on the Gaps-In-Noise (GIN) test.

    abstract::The Gaps-In-Noise (GIN) test is a new procedure used in the diagnosis of central auditory processing disorders. Performance on the GIN is recorded as approximate gap detection threshold and percent correct. In order to utilize the GIN test clinically, it is important to know how presentation level influences performan...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18.2.6

    authors: Weihing JA,Musiek FE,Shinn JB

    更新日期:2007-02-01 00:00:00

  • Enhancement of the Auditory Late Response (N1-P2) by Presentation of Stimuli From an Unexpected Location.

    abstract:BACKGROUND:Passive electrophysiological protocols, such as the middle latency response and speech auditory brainstem response, are often advocated in the objective assessment of central auditory processing disorder (CAPD). However, few established electrophysiological protocols exist for CAPD assessment that have patie...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17047

    authors: Heacock RM,Pigeon A,Chermak G,Musiek F,Weihing J

    更新日期:2019-06-01 00:00:00

  • Improving Hearing Performance for Cochlear Implant Recipients with Use of a Digital, Wireless, Remote-Microphone, Audio-Streaming Accessory.

    abstract:BACKGROUND:Cochlear implant (CI) recipients experience difficulty understanding speech in noise. Remote-microphone technology that improves the signal-to-noise ratio is recognized as an effective means to improve speech recognition in noise; however, there are no published studies evaluating the potential benefits of a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15005

    authors: Wolfe J,Morais M,Schafer E

    更新日期:2015-06-01 00:00:00

  • Behavioral and electrophysiologic binaural processing in persons with symmetric hearing loss.

    abstract:BACKGROUND:Binaural hearing improves our ability to understand speech and to localize sounds. Hearing loss can interfere with binaural cues, and despite the success of amplification, ∼25% of people with bilateral hearing loss fit with two hearing aids choose to wear only one (e.g., Brooks and Bulmer, 1981). One explana...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.22.3.6

    authors: Leigh-Paffenroth ED,Roup CM,Noe CM

    更新日期:2011-03-01 00:00:00

  • Rate, frequency, and intensity effects on early auditory evoked potentials and binaural interaction component in humans.

    abstract::The binaural interaction component (BIC) of the auditory brainstem response (ABR) and BIC of the frequency-following response (FFR) to tonal stimuli were studied in normal-hearing adults. The ABR and BIC latencies from all subjects were consistently shorter to the click-like sound than to the 2.0 kHz tone burst. Incre...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Parthasarathy TK,Moushegian G

    更新日期:1993-07-01 00:00:00

  • The Middle Latency Response: A Review of Findings in Various Central Nervous System Lesions.

    abstract:BACKGROUND:The middle latency response (MLR) first came to light as an auditory evoked potential in 1958. Since then, it has aroused substantial interest and investigation by clinicians and researchers alike. In recent history, its use and popularity have dwindled in tandem with various other auditory evoked potentials...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16141

    authors: Musiek F,Nagle S

    更新日期:2018-10-01 00:00:00

  • Reliability and validity of high-frequency (8-20 kHz) thresholds obtained on a computer-based audiometer as compared to a documented laboratory system.

    abstract::A Macintosh computer-based audiometer (Virtual 320) was evaluated for reliability and validity of high-frequency (8-20 kHz) thresholds by comparison with a well documented laboratory high-frequency evaluation system (PARVA-HF). High-frequency earphones originally provided with the V320 for high-frequency testing requi...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fausti SA,Frey RH,Henry JA,Knutsen JL,Olson DJ

    更新日期:1990-07-01 00:00:00

  • Masking redux. II: A recommended masking protocol.

    abstract::This is the second in a series of two papers on masking. The objective of these papers is to develop a masking protocol that provides valid measures of threshold and is, in general, faster than the plateau method. In the first paper, a masking method was presented that can replace the traditional plateau method in mos...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.1.5

    authors: Turner RG

    更新日期:2004-01-01 00:00:00

  • High resolution recording of late cortical surface potentials N1 and gamma band response (GBR).

    abstract::The present investigation was conducted to help determine whether source activity of the direct recorded N1 response differed from that of the gamma band response (GBR). Auditory evoked cortical potential data from two patients with intractable epilepsy undergoing prolonged video EEG monitoring after implantation of s...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Jacobson GP,Henderson J,Smith BJ,Elisevich KV

    更新日期:1998-04-01 00:00:00

  • Prediction and statistical evaluation of speech recognition test scores.

    abstract::A speech test evaluation and presentation system is described. The test presentation subsystem has the flexibility and speed of live-voice testing while using recorded test materials. The speech test evaluation subsystem compares an individual subject's test performance on a monosyllabic word test with that of an aver...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Studebaker GA,Gray GA,Branch WE

    更新日期:1999-07-01 00:00:00

  • Current research with cochlear implants at Arizona State University.

    abstract::In this article we review, and discuss the clinical implications of, five projects currently underway in the Cochlear Implant Laboratory at Arizona State University. The projects are (1) norming the AzBio sentence test, (2) comparing the performance of bilateral and bimodal cochlear implant (CI) patients in realistic ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.23.6.2

    authors: Dorman MF,Spahr A,Gifford RH,Cook S,Zhang T,Loiselle L,Yost W,Cardy L,Whittingham J,Schramm D

    更新日期:2012-06-01 00:00:00

  • Electrocochleography in the evaluation of patients with Ménière's disease/endolymphatic hydrops.

    abstract::Electrocochleography (ECochG) has evolved as an important tool in the diagnosis/assessment/monitoring of Ménière's disease/endolymphatic hydrops (MD/ELH). This manuscript provides an update on the use of ECochG for these purposes. The material presented includes descriptions of the components of the electrocochleogram...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:10.3766/jaaa.17.1.6

    authors: Ferraro JA,Durrant JD

    更新日期:2006-01-01 00:00:00

  • Speech intelligibility of young school-aged children in the presence of real-life classroom noise.

    abstract::We examined the ability of 40 young children (aged five to eight) to understand speech (monosyllables, spondees, trochees, and trisyllables) when listening in a background of real-life classroom noise. All children had some difficulty understanding speech when the noise was at levels found in many classrooms (i.e., 65...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15.7.5

    authors: Jamieson DG,Kranjc G,Yu K,Hodgetts WE

    更新日期:2004-07-01 00:00:00

  • An Evaluation of Motivational Interviewing for Increasing Hearing Aid Use: A Pilot Study.

    abstract:BACKGROUND:Motivational interviewing (MI) has been used in consultation settings to motivate hearing aid users to increase hearing aid usage. However, the effect of MI on those who use their hearing aids only rarely or not at all has not been explored. PURPOSE:The aims of this pilot study were to evaluate the effect o...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16184

    authors: Solheim J,Gay C,Lerdal A,Hickson L,Kvaerner KJ

    更新日期:2018-09-01 00:00:00

  • Alport syndrome: clinical update.

    abstract::This review of the literature on Alport syndrome (AS) places emphasis on genetic and clinical issues related to the sensorineural hearing loss in type III and type IV X-linked AS. The review covers prevalence, medical issues, genetic issues, audiologic findings, vestibular findings, the pathophysiology of hearing loss...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,评审

    doi:

    authors: Wester DC,Atkin CL,Gregory MC

    更新日期:1995-01-01 00:00:00

  • Measuring Binaural Temporal-Fine-Structure Sensitivity in Hearing-Impaired Listeners, Using the TFS-AF Test.

    abstract:BACKGROUND:Various methods have been used to measure temporal-fine-structure (TFS) sensitivity in hearing-impaired (HI) listeners. A new method called TFS-adaptive frequency (TFS-AF) test, tracks the highest frequency up to which a person can detect a given interaural phase difference (IPD) in bursts of pure tones. So ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.18068

    authors: Mathew DS,Sreenivasan A,Alexander A,Palani S

    更新日期:2020-02-01 00:00:00

  • The influence of aging on interaural asymmetries in middle latency response amplitude.

    abstract:BACKGROUND:Auditory-evoked potentials (EPs) provide a more objective assessment of central auditory nervous system (CANS) dysfunction when compared to behavioral measures because they do not require a behavioral response (Anderson and Kraus, 2010). In this regard, the middle latency response (MLR) has been considered a...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.4.4

    authors: Weihing J,Musiek F

    更新日期:2014-04-01 00:00:00

  • Within-subject comparison of speech perception benefits for congenitally deaf adolescents with an electrotactile speech processor and a cochlear implant.

    abstract::This study assessed speech perception benefits for three congenitally deaf adolescents who used an electrotactile speech processor (Tickle Talker(TM)) and subsequently went on to use a Nucleus Minisystem 22 cochlear implant. Both devices provided significant and comparable benefits for all children in the device plus ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Sarant J,Cowan R,Blamey P,Galvin K,Clark G

    更新日期:1996-04-01 00:00:00

  • Acoustic and hearing aid circuit variables affecting the tolerability of aided impulsive-type sounds.

    abstract::The tolerability of aided impulsive-type stimuli was investigated in a group of 13 hearing-impaired listeners. Two linear circuits (one with a class A and one with a class D output stage) and one adaptive frequency response (AFR) circuit (with a class D output stage) were investigated. In a three-way paired-comparison...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Fortune TW,Preves DA

    更新日期:1994-09-01 00:00:00

  • Progression of hearing loss following the completion of chemotherapy and radiation therapy: case report.

    abstract::There have been scattered accounts reported in the oncology literature of progressive hearing loss following the conclusion of chemotherapy. In this case study, we report the audiologic findings of such a case. These data underscore the need for post-therapy monitoring in cases where threshold shifts are discovered du...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Sweetow RW,Will TI

    更新日期:1993-11-01 00:00:00

  • Technical report: distortion product otoacoustic emissions that are not outer hair cell emissions.

    abstract:PURPOSE:To present a case study in order to alert clinicians to the possibility of occurrence of intermodulation distortion during otoacoustic emissions testing that arises from the cavity formed by the external auditory meatus and tympanic membrane rather than from the inner ear, compromising the reliability and valid...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.20.5.3

    authors: Silman S,Emmer MB,Silverman CA

    更新日期:2009-05-01 00:00:00

  • The influence of caffeine on calorics and cervical vestibular evoked myogenic potentials (cVEMPs).

    abstract:BACKGROUND:Prior to undergoing vestibular function testing, it is not uncommon for clinicians to request that patients abstain from caffeine 24 hr prior to the administration of the tests. However, there is little evidence that caffeine affects vestibular function. PURPOSE:To evaluate whether the results from two test...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.25.3.5

    authors: McNerney K,Coad ML,Burkard R

    更新日期:2014-03-01 00:00:00

  • A Comparison of Word-Recognition Performances on the Auditec and VA Recorded Versions of Northwestern University Auditory Test No. 6 by Young Listeners with Normal Hearing and by Older Listeners with Sensorineural Hearing Loss Using a Randomized Presentat

    abstract:BACKGROUND:The Auditec of St. Louis and the Department of Veterans Affairs (VA) recorded versions of the Northwestern University Auditory Test No. 6 (NU-6) are in common usage. Data on young adults with normal hearing for pure tones (YNH) demonstrate equal recognition performances on the two versions when the VA versio...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章,随机对照试验

    doi:10.3766/jaaa.17135

    authors: Wilson RH

    更新日期:2019-05-01 00:00:00

  • The Effect of Contralateral Pure Tones on the Compound Action Potential in Humans: Efferent Tuning Curves.

    abstract:BACKGROUND:The compound action potential (CAP) has been suggested in the literature as an alternative to otoacoustic emissions for evaluating the efferent auditory system. However, very few studies have examined efferent influence on auditory nerve potentials in humans. PURPOSE:This study examines the effects of prese...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.15002

    authors: Najem F,Ferraro J,Chertoff M

    更新日期:2016-02-01 00:00:00

  • Routine use of the crystal device integrity testing system in pediatric patients.

    abstract::Crystal Device Integrity Testing System (CITS), the first commercially available testing system of its type, allows rapid assessment of cochlear implant function by measuring averaged electrode voltages-the scalp-recorded fields generated by electrode currents. We describe our experience performing routine integrity t...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.17.10.4

    authors: Monin DL,Kazahaya K,Franck KH

    更新日期:2006-11-01 00:00:00

  • Valsalva shift among smokers and nonsmokers.

    abstract::Although it has been reported that smoking has deleterious effects on the middle ears of smokers, including their eustachian tubes, investigators have failed to find differences in the tympanometric characteristics of smokers and nonsmokers. In the present study, however, we found that the Valsalva-induced tympanometr...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Steiger JR,Champon TA

    更新日期:1997-08-01 00:00:00

  • Effects of pre-existing hearing loss and gender on proposed ANSI S12.13 outcomes for characterizing hearing conservation program effectiveness: preliminary investigation.

    abstract::Draft American National Standard "Evaluating the Effectiveness of Hearing Conservation Programs" identifies potentially important links between audiometric threshold variability outcomes and occupational hearing conservation program (HCP) practices. Unacceptable threshold variability in annual audiograms may identify ...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:

    authors: Amos NE,Simpson TH

    更新日期:1995-11-01 00:00:00

  • Exponential Modeling of Frequency-Following Responses in American Neonates and Adults.

    abstract:BACKGROUND:The scalp-recorded frequency-following response (FFR) has been widely accepted in assessing the brain's processing of speech stimuli for people who speak tonal and nontonal languages. Characteristics of scalp-recorded FFRs with increasing number of sweeps have been delineated through the use of an exponentia...

    journal_title:Journal of the American Academy of Audiology

    pub_type: 杂志文章

    doi:10.3766/jaaa.16135

    authors: Jeng FC,Nance B,Montgomery-Reagan K,Lin CD

    更新日期:2018-02-01 00:00:00