Evaluation of ten manual resuscitators across an operational temperature range of -18 degrees C to 50 degrees C.

Abstract:

UNLABELLED:Because of the temperature extremes encountered during emergency resuscitation and transport in the field, we sought to evaluate the performance and safety of 10 adult resuscitators (5 permanent units: Hope 4, Laerdal, Lifesaver, Mark 3, and PMR; and 5 disposable units: BagEasy, Code Blue, CPR Bag, DMR, and SPUR) across an operational temperature range of -18 degrees C to 50 degrees C. METHOD:We tested the devices against the American Society for Testing and Materials (ASTM) Standard F-920 and the International Organization for Standardization (ISO) Standard 8382. We tested each resuscitator by using a lung model, the Bio-Tek VT-1 Ventilator Tester. RESULTS:All of the resuscitators met the ventilation requirements for VT and F (600 mL X 20) and I:E less than 1:1 except the SPUR at -18 degrees C. Standards ASTM F-920 and ISO 8382 specify a fractional delivered oxygen concentration (FDO2) of greater than or equal to 0.85 with attachments and greater than or equal to 0.40 without attachments at oxygen flow of 15 L/min and VE of 7.2 L/min (600 mL X 12). Nine resuscitators met Standards ASTM F-920 and ISO 8382 for FDO2 with attachments at 21 degrees C and 50 degrees C, but only 3 units (Code Blue, DMR, and PMR) passed at -18 degrees C. At 21 degrees C, the Hope 4 had an FDO2 of 0.77 +/- 0.03, which was significantly lower (p less than 0.001) than that of the other 9 resuscitators, all of which were greater than or equal to 0.93. Nine resuscitators met the FDO2 standard without attachments. All 10 resuscitators passed the tests for valve function after contamination with simulated vomitus (at an oxygen flow of 30 L/min) and for backward leakage. At the ventilation pattern recommended by the American Heart Association (AHA) (800 mL X 12) the PMR's mean FDO2 dropped to 0.86 +/- 0.03 because of air leaking into the bag where it attaches to the patient-valve assembly. All 10 resuscitators passed the test for mechanical shock at 21 degrees C and 50 degrees C, but 3 units failed at -18 degrees C. CONCLUSION:We conclude that only the Code Blue and DMR meet the ASTM and ISO standards for operator-powered adult resuscitators across the operational temperature range of -18 degrees C to 50 degrees C.

journal_name

Respir Care

journal_title

Respiratory care

authors

Barnes TA,Stockwell DL

keywords:

subject

Has Abstract

pub_date

1991-03-01 00:00:00

pages

161-72

issue

3

eissn

0020-1324

issn

1943-3654

journal_volume

36

pub_type

杂志文章
  • Mucus, phlegm, and sputum in cystic fibrosis.

    abstract::Although some clinicians still believe that cystic fibrosis (CF) lung disease is largely due to hypersecretion of very viscous mucus, it has never been demonstrated that there is mucus hypersecretion in CF and it is clear that there is almost no intact mucin (the principal polymeric component of normal mucus) in CF sp...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/002013209790983269

    authors: Rubin BK

    更新日期:2009-06-01 00:00:00

  • Spirometric correlates of dyspnea improvement among emergency department patients with chronic obstructive pulmonary disease exacerbation.

    abstract:OBJECTIVE:To examine whether change in slow vital capacity (SVC) correlates to dyspnea improvement during emergency department (ED) treatment of chronic obstructive pulmonary disease (COPD) exacerbation. METHODS:We performed a prospective cohort study and enrolled consecutive patients during a 3-week period. ED patien...

    journal_title:Respiratory care

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Camargo CA Jr,Tsai CL,Clark S,Kenney PA,Radeos MS

    更新日期:2008-07-01 00:00:00

  • Respiratory dysfunction and pulmonary disease in cirrhosis and other hepatic disorders.

    abstract::End-stage liver disease and its complications are a leading cause of death among adults in the United States, and thousands of patients await liver transplantation. The liver plays a central role in health and homeostasis and thus the diseased liver leads to many deleterious effects on multiple organ systems, includin...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:

    authors: Huffmyer JL,Nemergut EC

    更新日期:2007-08-01 00:00:00

  • Development of a Web-Based Tool Built From Pharmacy Claims Data to Assess Adherence to Respiratory Medications in Primary Care.

    abstract:BACKGROUND:Medication adherence in asthma and COPD is notoriously low. To intervene effectively, family physicians need to assess adherence accurately, which is a challenging endeavor. In collaboration family physicians and individuals with asthma or COPD, we aimed to explore the barriers and facilitators of assessing ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.07328

    authors: Yousif A,Peláez S,Lemière C,Forget A,Dalal C,Turcotte MK,Beauchesne MF,Blais L

    更新日期:2020-09-01 00:00:00

  • Perception of Exercise-Induced Bronchoconstriction in College Athletes.

    abstract:BACKGROUND:Exercise-induced bronchoconstriction (EIB) can lead to long-term respiratory illness and even death. EIB prevalence rates are both high and variable in college athletes. Also, prevalence rates may be underestimated due to ineffective screening. The purpose of this study is to investigate the prevalence of EI...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.04553

    authors: Burnett DM,Vardiman JP,Deckert JA,Ward JL,Sharpe MR

    更新日期:2016-07-01 00:00:00

  • Home unattended portable monitoring and automatic CPAP titration in patients with high risk for moderate to severe obstructive sleep apnea.

    abstract:BACKGROUND:Obstructive sleep apnea is a disorder characterized by recurrent obstruction of the upper airways during sleep. The high prevalence of this disease led to proposed new strategies based on the home evaluation and management of patients. OBJECTIVE:To compare home unattended portable monitoring and automatic C...

    journal_title:Respiratory care

    pub_type: 杂志文章,随机对照试验

    doi:10.4187/respcare.01939

    authors: Tedeschi E,Carratù P,Damiani MF,Ventura VA,Drigo R,Enzo E,Ferraresso A,Sasso G,Zambotto FM,Resta O

    更新日期:2013-07-01 00:00:00

  • A model for the evaluation of respiratory therapy program admissions criteria.

    abstract:UNLABELLED:Attrition in respiratory therapy programs is a waste of both human and economic resources and may be one cause of the current shortage of qualified personnel. Poor academic performance has been shown to be the leading cause of program attrition. The purposes of this study were to establish the predictive abi...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Flanigan KS

    更新日期:1985-05-01 00:00:00

  • Feasibility and Efficacy of Pulsed-Dose Oxygen Delivery During Noninvasive Ventilation.

    abstract:BACKGROUND:It is difficult to apply noninvasive ventilation (NIV) simultaneously with pulsed-dose oxygen delivery. We evaluated the feasibility and efficacy of pulsed-dose oxygen delivery during NIV. METHODS:A bench study was conducted using a simulated lung during NIV, with a breathing frequency of 10 or 20 breaths/m...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.06922

    authors: Li LL,Yang HY,Jin H,Dai B,Peng Y,Tan W

    更新日期:2020-09-01 00:00:00

  • Feasibility and effectiveness of an educational program in Italian COPD patients undergoing rehabilitation.

    abstract:BACKGROUND:Self-management education is associated with improvement in quality of life and reduction of hospital admissions. Nevertheless, the data are insufficient to formulate clear recommendations regarding the type and content of education programs for COPD patients, and few data are available on knowledge of the d...

    journal_title:Respiratory care

    pub_type: 临床试验,杂志文章

    doi:10.4187/respcare.01697

    authors: Paneroni M,Clini E,Crisafulli E,Guffanti E,Fumagalli A,Bernasconi A,Cabiaglia A,Nicolini A,Brogi S,Ambrosino N,Peroni R,Bianchi L,Vitacca M

    更新日期:2013-02-01 00:00:00

  • Dynamic Airway Driving Pressure and Outcomes in Children With Acute Hypoxemic Respiratory Failure.

    abstract:BACKGROUND:Limited adult data suggest that airway driving pressure might better reflect the potential risk for lung injury than tidal volume based on ideal body weight, and the parameter correlates with mortality in ARDS. There is a lack of data about the effect of driving pressure on mortality in pediatric ARDS. This ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.08024

    authors: Rauf A,Sachdev A,Venkataraman ST,Dinand V

    更新日期:2020-10-06 00:00:00

  • Mechanical Ventilation Alarms and Alarm Fatigue.

    abstract::Mechanical ventilation alarms and alerts, both audible and visual, provide the clinician with vital information about the patient's physiologic condition and the status of the machine's function. Not all alarms generated by the mechanical ventilator provide actionable information. Over time, clinicians can become dese...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:10.4187/respcare.06878

    authors: Scott JB,De Vaux L,Dills C,Strickland SL

    更新日期:2019-10-01 00:00:00

  • The Risk and Related Factors for Readmission to an ICU Within 7 Days in Mechanically Ventilated Subjects--A Nationwide Population-Based Cohort Study.

    abstract:BACKGROUND:Readmission of mechanically ventilated patients to an ICU within 7 d reflects not only patient safety but also the quality of care of the ICU. This study aimed to investigate the risk and related factors for readmission to an ICU within 7 d in mechanically ventilated subjects. METHODS:A total of 658,452 mec...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.03868

    authors: Chu CC,Liu CJ,Shih CM,Kung PT,Tsai YS,Tsai WC

    更新日期:2015-12-01 00:00:00

  • Surveys: an introduction.

    abstract::Surveys are a valuable research tool for studying the knowledge, attitudes, and behavior of a study population. This article explores quantitative analyses of written questionnaires as instruments for survey research. Obtaining accurate and precise information from a survey requires minimizing the possibility of bias ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Rubenfeld GD

    更新日期:2004-10-01 00:00:00

  • Care of the ventilator circuit and its relation to ventilator-associated pneumonia.

    abstract::Ventilator circuits should not be changed routinely for infection control purposes. The maximum duration of time that circuits can be used safely is unknown. Evidence is lacking related to ventilator-associated pneumonia (VAP) and issues of heated versus unheated circuits, type of heated humidifier, method for filling...

    journal_title:Respiratory care

    pub_type: 指南,杂志文章,实务指引

    doi:

    authors: Hess DR,Kallstrom TJ,Mottram CD,Myers TR,Sorenson HM,Vines DL,American Association for Respiratory Care.

    更新日期:2003-09-01 00:00:00

  • Comparing Noninvasive Ventilation Delivered Using Neurally-Adjusted Ventilatory Assist or Pressure Support in Acute Respiratory Failure.

    abstract:BACKGROUND:The use of neurally-adjusted ventilatory assist (NAVA) during noninvasive ventilation (NIV) results in better patient-ventilator interaction. Whether this improves clinical outcomes lacks dedicated study. METHODS:In this randomized controlled trial, we compared NAVA with PSV for delivering NIV in consecutiv...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.07952

    authors: Prasad KT,Gandra RR,Dhooria S,Muthu V,Aggarwal AN,Agarwal R,Sehgal IS

    更新日期:2021-02-01 00:00:00

  • The expanding role of aerosols in systemic drug delivery, gene therapy, and vaccination.

    abstract::Aerosolized medications have been used for centuries to treat respiratory diseases. Until recently, inhalation therapy focused primarily on the treatment of asthma and chronic obstructive pulmonary disease, and the pressurized metered-dose inhaler was the delivery device of choice. However, the role of aerosol therapy...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:

    authors: Laube BL

    更新日期:2005-09-01 00:00:00

  • An assessment of the appropriateness of respiratory care delivered at a 450-bed acute care Veterans affairs hospital.

    abstract:INTRODUCTION:Respiratory care is expensive and time-intensive, inappropriate care wastes resources, and failure to provide necessary and appropriate respiratory care may adversely affect patient outcomes. OBJECTIVE:To determine the appropriateness of basic respiratory care delivered at a 450-bed Veterans Affairs hospi...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Shelledy DC,LeGrand TS,Peters JI

    更新日期:2004-08-01 00:00:00

  • Heliox and forward-leaning posture improve the efficacy of nebulized bronchodilator in acute asthma: a randomized trial.

    abstract:BACKGROUND:Heliox and forward-leaning posture (torso inclined forward at 50-60° with the elbows resting on the thighs) are adjuncts in the administration of nebulized bronchodilator to patients with acute asthma. METHODS:We randomized 59 patients who presented to the emergency department in severe asthma crisis, into ...

    journal_title:Respiratory care

    pub_type: 杂志文章,随机对照试验

    doi:10.4187/respcare.00963

    authors: Brandão DC,Britto MC,Pessoa MF,de Sá RB,Alcoforado L,Matos LO,Silva TN,de Andrade AD

    更新日期:2011-07-01 00:00:00

  • A risk tertiles model for predicting mortality in patients with acute respiratory distress syndrome: age, plateau pressure, and P(aO(2))/F(IO(2)) at ARDS onset can predict mortality.

    abstract:BACKGROUND:Predicting mortality has become a necessary step for selecting patients for clinical trials and defining outcomes. We examined whether stratification by tertiles of respiratory and ventilatory variables at the onset of acute respiratory distress syndrome (ARDS) identifies patients with different risks of dea...

    journal_title:Respiratory care

    pub_type: 杂志文章,多中心研究

    doi:10.4187/respcare.00811

    authors: Villar J,Pérez-Méndez L,Basaldúa S,Blanco J,Aguilar G,Toral D,Zavala E,Romera MA,González-Díaz G,Nogal FD,Santos-Bouza A,Ramos L,Macías S,Kacmarek RM,Hospitales Españoles Para el Estudio de la Lesión Pulmonar (HELP) Network*.

    更新日期:2011-04-01 00:00:00

  • Recommendations of the Fifth Oxygen Consensus Conference. Writing and Organizing Committees.

    abstract::It should be recognized that the advent of LTOT created a new health care system that is based on powerful scientific data. Oxygen therapy studies such as those by the Nocturnal Oxygen Therapy Trial Group and the British Medical Research Council study clearly demonstrated that LTOT improves both the length and quality...

    journal_title:Respiratory care

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Petty TL,Casaburi R

    更新日期:2000-08-01 00:00:00

  • The impact of computer-age technology on respiratory therapy.

    abstract::Computer-age technology is changing the face of respiratory therapy as it is that of nearly every other technical field. In some hospital respiratory therapy departments computers are presently being used for a wide range of functions such as blood gas result reporting, billing, budgeting, purchasing, hemodynamic calc...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: McPeck M

    更新日期:1982-07-01 00:00:00

  • Determinants of patient adherence to an aerosol regimen.

    abstract::Patient adherence with prescribed inhaled therapy is related to morbidity and mortality. The terms "compliance" and "adherence" are used in the literature to describe agreement between prescribed medication and patient practice, with "adherence" implying active patient participation. Patient adherence with inhaled med...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:

    authors: Rau JL

    更新日期:2005-10-01 00:00:00

  • How to write an effective discussion.

    abstract::Explaining the meaning of the results to the reader is the purpose of the discussion section of a research paper. There are elements of the discussion that should be included and other things that should be avoided. Always write the discussion for the reader; remember that the focus should be to help the reader unders...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Hess DR

    更新日期:2004-10-01 00:00:00

  • Humidification in Very-High-Flow Nasal-Cannula Therapy in an Adult Lung Model.

    abstract:BACKGROUND:High-flow nasal cannula (HFNC) therapy is used for patients with respiratory failure. Recently, HFNC therapy with very high gas flows (ie, gas flows of 60-100 L/min) was reported to generate higher positive airway pressure and an associated decrease in breathing frequency. However, the humidification of HFNC...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.06417

    authors: Chikata Y,Morinishi K,Nishimura M

    更新日期:2019-07-01 00:00:00

  • Unilateral expiratory airflow obstruction during forced exhalation.

    abstract::We present a case of unilateral airflow obstruction during forced exhalations. The patient presented with episodic dyspnea and wheezing, particularly when he lay in the right lateral decubitus position. Spirometry revealed symmetric, marked reductions in forced expiratory volume in the first second and forced vital ca...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:

    authors: Hatipoglu U,Laghi F,Cattapan SE,Chandrasekhar AJ

    更新日期:2002-06-01 00:00:00

  • The Concave Shape of the Forced Expiratory Flow-Volume Curve in 3 Seconds Is a Practical Surrogate of FEV1/FVC for the Diagnosis of Airway Limitation in Inadequate Spirometry.

    abstract:BACKGROUND:Spirometry is important for the differential diagnosis of dyspnea. However, some patients cannot exhale for ≥6 s to achieve the American Thoracic Society/European Respiratory Society criteria. The aim of this study was to demonstrate the reliability of a new parameter that quantifies the degree of concavity ...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.05016

    authors: Li H,Liu C,Zhang Y,Xiao W

    更新日期:2017-03-01 00:00:00

  • Variation Among Spirometry Interpretation Algorithms.

    abstract::Several algorithms exist to facilitate spirometric interpretation in clinical practice, yet there is a lack of consensus on how spirometric criteria for asthma, COPD, and restrictive disorders should be incorporated into spirometry interpretation algorithms suitable for use in day-to-day primary care management. The p...

    journal_title:Respiratory care

    pub_type: 杂志文章

    doi:10.4187/respcare.07294

    authors: D'Urzo KA,Mok F,D'Urzo AD

    更新日期:2020-10-01 00:00:00

  • Evidence-based asthma management.

    abstract::In 2002 the National Asthma Education and Prevention Program published evidence-based guidelines for the diagnosis and management of asthma, but there are some unresolved asthma-management issues that need further research. For asthmatic children inhaled corticosteroids are more beneficial than as-needed use of beta(2...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:

    authors: Kallstrom TJ

    更新日期:2004-07-01 00:00:00

  • Oxygenation With a Single Portable Pulse-Dose Oxygen-Conserving Device and Combined Stationary and Portable Oxygen Delivery Devices in Subjects With COPD.

    abstract:BACKGROUND:Portable oxygen devices simplify and facilitate patient therapy. This study was designed to compare S(pO2) and patient satisfaction with a portable oxygen concentrator or a combined system consisting of a fixed device with continuous-flow oxygen dispensation and a portable device with pulse dispensation for ...

    journal_title:Respiratory care

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.4187/respcare.03470

    authors: Yáñez AM,Prat JP,Álvarez-Sala JL,Calle M,Díaz Lobato S,García Gonzalez JL,Rodríguez Gonzalez-Moro JM,Galera-Martínez R,Villasante C,Ramos I,Franco-Gay M,de Lucas P

    更新日期:2015-03-01 00:00:00

  • Heliox during mechanical ventilation.

    abstract::The indications for heliox during mechanical ventilation are lower-airway obstruction, especially with hypercarbia; need to enhance aerosol delivery to lung periphery; and need to facilitate weaning from mechanical ventilation. Certain ventilators perform relatively well with heliox and are not substantially affected ...

    journal_title:Respiratory care

    pub_type: 杂志文章,评审

    doi:

    authors: Venkataraman ST

    更新日期:2006-06-01 00:00:00