Time-to-effect guided pulmonary vein isolation utilizing the third-generation versus second generation cryoballoon: One year clinical success.

Abstract:

BACKGROUND:The second-generation cryoballoon (CB2) provides effective and durable pulmonary vein isolation (PVI) associated with encouraging and reproducible clinical outcome data. The latest- -generation cryoballoon (CB3) incorporates a 40% shorter distal tip, thus allowing for an increased rate of PVI real-time signal recording and facilitating individualized ablation strategies taking the time-to- -effect (TTE) into account. However, whether this characteristic translates into favorable clinical success has not been evaluated yet. Herein was investigated 1-year clinical success after CB3 in comparison to CB2 based-PVI. METHODS:One hundred and ten consecutive patients with paroxysmal or short-standing persistent atrial fibrillation (AF) underwent CB2 (n = 55 patients) -or CB3 (n = 55 patients) -based PVI. The freeze-cycle duration was set to TTE + 120 s if TTE could be recorded, otherwise a fixed freeze-cycle duration of 180 s was applied. RESULTS:A total of 217/218 (99%, CB3) and 217/217 (100%, CB2) pulmonary veins (PV) were successfully isolated. The real-time PVI visualization rate was 69.2% (CB3) and 54.8% (CB2; p = 0.0392). The mean freeze-cycle duration was 194 ± 77 s (CB3) and 206 ± 85 s (CB2; p = 0.132), respectively. During a median follow-up of 409 days (interquartile range [IQR] 378-421, CB3) and 432 days (IQR 394-455, CB2) 73.6% (CB3) and 73.1% of patients (CB2) remained in stable sinus rhythm after a single procedure (p = 0.806). CONCLUSIONS:A higher rate of real-time electrical PV recordings was seen using the CB3 as compared to CB2. There was no difference in 1-year clinical follow-up.

journal_name

Cardiol J

journal_title

Cardiology journal

authors

Heeger CH,Schuette C,Seitelberger V,Wissner E,Rillig A,Mathew S,Reissmann B,Lemes C,Maurer T,Fink T,Inaba O,Hashiguchi N,Santoro F,Ouyang F,Kuck KH,Metzner A

doi

10.5603/CJ.a2018.0056

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

368-374

issue

4

issn

1897-5593

pii

VM/OJS/J/57324

journal_volume

26

pub_type

杂志文章
  • Diagnostic accuracy and reproducibility of optical flow ratio for functional evaluation of coronary stenosis in a prospective series.

    abstract:BACKGROUND:Evaluating prospectively the feasibility, accuracy and reproducibility of optical flow ratio (OFR), a novel method of computational physiology based on optical coherence tomography (OCT). METHODS AND RESULTS:Sixty consecutive patients (76 vessels) underwent prospectively OCT, angiography- based quantitative...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2020.0071

    authors: Gutiérrez-Chico JL,Chen Y,Yu W,Ding D,Huang J,Huang P,Jing J,Chu M,Wu P,Tian F,Xu B,Tu S

    更新日期:2020-01-01 00:00:00

  • Evaluation of coronary artery abnormalities in Williams syndrome patients using myocardial perfusion scintigraphy and CT angiography.

    abstract:BACKGROUND:Sudden death risk in Williams syndrome (WS) patients has been shown to be 25-100 times higher than in the general population. This study aims to detect coronary artery anomalies and myocardial perfusion defects in WS patients using noninvasive diagnostic methods. METHODS:This study features 38 patients diag...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/cj.2012.0053

    authors: Ergul Y,Nisli K,Kayserili H,Karaman B,Basaran S,Dursun M,Yilmaz E,Ergul N,Unal SN,Dindar A

    更新日期:2012-01-01 00:00:00

  • Diagnostic value of flow mediated dilatation measurement for coronary artery lesions in men under 45 years of age.

    abstract:BACKGROUND:In those without symptoms of coronary artery disease (CAD), the incidence of coronary events is still high. The aim of this study was to evaluate whether flow mediated dilatation (FMD) is a useful tool in identifying those with CAD in who are under 45 years of age. METHODS AND RESULTS:Seventy five men below...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:

    authors: Kaźmierski M,Michalewska-Włudarczyk A,Krzych LJ,Tendera M

    更新日期:2010-01-01 00:00:00

  • The impact of transferring patients with ST-segment elevation myocardial infarction to percutaneous coronary intervention-capable hospitals on clinical outcomes.

    abstract:BACKGROUND:Primary percutaneous coronary intervention (PCI) is recommended for ST-segment elevation myocardial infarction (STEMI) patients even when the patient must be transported to a PCI-capable hospital. This study aimed to evaluate the long-term clinical outcomes of STEMI patients who were transferred for primary ...

    journal_title:Cardiology journal

    pub_type: 杂志文章,多中心研究

    doi:10.5603/CJ.a2016.0003

    authors: Kim BW,Cha KS,Park MJ,Choi JH,Yun EY,Park JS,Lee HW,Oh JH,Kim JS,Choi JH,Park YH,Lee HC,Kim JH,Chun KJ,Hong TJ,Ahn Y,Jeong MH

    更新日期:2016-01-01 00:00:00

  • Importance of cardiac biomarkers in risk stratification in acute pulmonary embolism.

    abstract::At present there is consent that patients with acute pulmonary embolism (APE) and hemodynamic instability have poor prognosis and benefit from thrombolytic therapy or embolectomy, whereas hemodynamically stable patients without echocardiographic signs of right ventricular overload/dysfunction (RVO) have good prognosis...

    journal_title:Cardiology journal

    pub_type: 杂志文章,评审

    doi:

    authors: Mikulewicz M,Lewczuk J

    更新日期:2008-01-01 00:00:00

  • Post-procedural TIMI flow grade 2 is not associated with improved prognosis in patients with non-ST-segment elevation myocardial infarction undergoing percutaneous coronary revascularization (PL-ACS registry).

    abstract:BACKGROUND:The impact of final Thrombolysis in Myocardial Infarction (TIMI) flow in the infarct-related artery (IRA) on outcomes in non-ST-segment elevation myocardial infarc-tion (NSTEMI) patients treated with percutaneous coronary intervention (PCI) is unknown. This study aimed to evaluate the impact of post-procedur...

    journal_title:Cardiology journal

    pub_type: 杂志文章,多中心研究

    doi:10.5603/CJ.a2016.0025

    authors: Karwowski J,Poloński L,Gierlotka M,Gąsior M,Bęćkowski M,Kowalik I,Szwed H

    更新日期:2016-01-01 00:00:00

  • Cryoballoon ablation of atrial fibrillation: How important is the proper selection of patients?

    abstract:BACKGROUND:Relation between pre-procedural selection of patients and the success rate after a single cryoballoon ablation (CAB) procedure is unknown. METHODS:CAB was performed in 378 (65% male, median age 58 years, 85% paroxysmal atrial fibrillation [AF]) consecutive patients with symptomatic and drug refractory AF. T...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2014.0100

    authors: Wójcik M,Berkowitsch A,Zaltsberg S,Hamm CW,Pitschner HF,Kuniss M,Neumann T

    更新日期:2015-01-01 00:00:00

  • Evaluation of a direct access cardiac arrhythmia monitoring service.

    abstract:BACKGROUND:This paper describes the clinical outcomes from a novel direct access arrhythmia monitoring service. METHODS:The study was carried out in the north of Scotland. Data was collected over a 29 month period between 18 June 2008 and 8 November 2010 from consecutive cases from two groups of patients, general prac...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/cj.2012.0010

    authors: Skipsey DA,Dawson FM,Breen C,Leslie SJ

    更新日期:2012-01-01 00:00:00

  • Quality of visualization of coronary venous system in 64-slice computed tomography.

    abstract:BACKGROUND:Multi-slice computed tomography (MSCT) can be used to visualize the anatomy of the coronary venous system (CVS). A pre-procedural evaluation of target veins is a very important element of cardiac resynchronization. Thus, the quality of visualization of the CVS is of great importance. The aim of this study wa...

    journal_title:Cardiology journal

    pub_type: 临床试验,杂志文章

    doi:

    authors: Młynarska A,Młynarski R,Kargul W,Sosnowski M

    更新日期:2011-01-01 00:00:00

  • Feasibility of zero or near zero fluoroscopy during catheter ablation procedures.

    abstract:BACKGROUND:Awareness of risks associated with radiation exposure to patients and medical staff has significantly increased. It has been reported before that the use of advanced three-dimensional electroanatomical mapping (EAM) system significantly reduces fluoroscopy time, however this study aimed for zero or near zero...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2018.0029

    authors: Haegeli LM,Stutz L,Mohsen M,Wolber T,Brunckhorst C,On CJ,Duru F

    更新日期:2019-01-01 00:00:00

  • Sick euthyroid syndrome is associated with poor prognosis in patients with ST segment elevation myocardial infarction undergoing primary percutaneous intervention.

    abstract:BACKGROUND:Concomitant thyroid and heart disease are frequently encountered in clinical practice. There are many studies evaluating thyroid function in acute and critical conditions. Information on thyroid dysfunction in ST-segment elevation myocardial infarction (STEMI) is limited; its correlation with short and long-...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2013.0108

    authors: Özcan KS,Osmonov D,Toprak E,Güngör B,Tatlısu A,Ekmekçi A,Kaya A,Tayyareci G,Erdinler İ

    更新日期:2014-01-01 00:00:00

  • The association between coronary flow rate and impaired heart rate recovery in patients with metabolic syndrome: A preliminary report.

    abstract:BACKGROUND:The aim of this study is to evaluate heart rate recovery (HRR) and association between coronary flow rate and HRR in patients with metabolic syndrome (MS) who had morphologically normal coronary angiogram. METHODS:Study population included 43 patients with MS and 37 control subjects without MS. All patients...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2013.0119

    authors: Alihanoglu YI,Kilic ID,Evrengul H,Yildiz BS,Alur I,Uludag B,Kuru O,Taskoylu O,Kaftan HA

    更新日期:2014-01-01 00:00:00

  • Percutaneous reconstruction of the continuity of a functionally interrupted aortic arch using a stent.

    abstract::A case of a 26-year-old man without continuity of blood flow in the level of the isthmus of the aorta is described. During interventional catheterization, we reconstructed this continuity and implanted a vascular stent. ...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:

    authors: Kusa J,Szkutnik M,Białkowski J

    更新日期:2008-01-01 00:00:00

  • Lymphopenia and mortality among patients undergoing coronary angiography: Long-term follow-up study.

    abstract:BACKGROUND:Lymphopenia is associated with adverse prognosis in chronic disease states that are related to immune dysregulation. We aimed to determine the association between lymphopenia and mortality in patients presenting to coronary angiography and investigate whether elevated red blood cell distribution width (RDW),...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2020.0141

    authors: Zafrir B,Hussein S,Jaffe R,Barnett-Griness O,Saliba W

    更新日期:2020-11-03 00:00:00

  • Prevalence and prognostic relevance of myocardial inflammation and cardiotropic viruses in non-ischemic dilated cardiomyopathy.

    abstract:BACKGROUND:Non-ischemic dilated cardiomyopathy (DCM) is a heterogeneous disease with a spectrum of etiological factors. However, subsets of the disease are not well-characterized with respect to these factors. The aim of this study was to evaluate the prevalence of myocardial inflammation and cardiotropic viruses in DC...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2020.0088

    authors: Kažukauskienė I,Baltrūnienė V,Jakubauskas A,Žurauskas E,Maneikienė VV,Daunoravičius D,Čelutkienė J,Ručinskas K,Grabauskienė V

    更新日期:2020-06-22 00:00:00

  • Whether noninvasive optimization of AV and VV delays improves the response to cardiac resynchronization therapy.

    abstract:BACKGROUND:Device optimization is not routinely performed in patients who underwent cardiac resynchronization therapy (CRT) device implantation. Noninvasive optimization of CRT devices by measurement of cardiac output (CO) can be used as a simple method to assess ventricular systolic performance. The aim of this study ...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.2013.0100

    authors: Urbanek B,Chudzik M,Klimczak A,Rosiak M,Lewek J,Wranicz JK

    更新日期:2013-01-01 00:00:00

  • Improved arterial stiffness in mitral stenosis after successful percutaneous balloon valvuloplasty.

    abstract:BACKGROUND:Rheumatic mitral stenosis (MS) is still a common disease in developing countries with high morbidity and mortality rates. The purpose of the study was to evaluate arterial stiffness in severe MS before and after percutaneous mitral balloon valvuloplasty (PMBV). METHODS:Thirty patients with MS in sinus rhyth...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/cj.2012.0109

    authors: Ozdogru I,Celik A,Dogan A,Orscelik O,Sahin O,Elcik D,Saka T,Topsakal R,Oguzhan A

    更新日期:2012-01-01 00:00:00

  • The ventricular assist device: a bridge to ventricular recovery, a bridge to heart transplantation or destination therapy?

    abstract::Despite advances in pharmacological treatments aimed at a neurohormonal blockade for heart failure, there is still a growing number of patients with advanced symptoms who suffer significant morbidity and mortality. At present the most effective cure for end-stage congestive heart failure is cardiac transplantation. Th...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:

    authors: Bielecka A,Wierzbicka M,Goch J

    更新日期:2007-01-01 00:00:00

  • Synergistic effects of cardiac resynchronization therapy and Bachmann's bundle pacing on heart failure with atrial tachyarrhythmias.

    abstract::Cardiac resynchronization therapy (CRT) is electrical resynchronization of the ventricles. Bachmann's bundle (BB) pacing is considered to be electrical resynchronization of the atria. Atrial fibrillation (AF) and congestive heart failure (HF) often coexist in the same patient. A 69 year-old man who underwent CRT combi...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:

    authors: Omichi C,Kawasaki A,Kasai A

    更新日期:2009-01-01 00:00:00

  • Right ventricular morphology and function is not related with microRNAs and fibrosis markers in dilated cardiomyopathy.

    abstract:BACKGROUND:The relationship between right ventricle (RV), extracellular matrix (ECM) fibrosis and fibrosis-linked, circulating microRNAs in dilated cardiomyopathy (DCM) is unknown. AIM:The aim of the study was to uncover the associations between serum markers of ECM metabolism and circulating microRNAs with RV morphol...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2017.0099

    authors: Rubiś P,Totoń-Żurańska J,Wiśniowska-Śmiałek S,Kołton-Wróż M,Wołkow P,Wypasek E,Rudnicka-Sosin L,Pawlak A,Kozanecki K,Tomkiewicz-Pająk L,Podolec P

    更新日期:2018-01-01 00:00:00

  • Relationship between R-R interval variation and left ventricular function in sinus rhythm and atrial fibrillation as estimated by means of heart rate variability fraction.

    abstract:BACKGROUND:Reduced heart rate variability (HRV) is associated with a poor outcome in patients with sinus rhythm (SR) or atrial fibrillation (AF). However, cut-off points for HRV measures differ between SR and AF. We hypothesized that a global index of 24-hour HRV based on evaluation of scatterplot would describe HRV ir...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/cj.2011.0010

    authors: Sosnowski M,Korzeniowska B,Macfarlane PW,Tendera M

    更新日期:2011-01-01 00:00:00

  • Left ventricular diverticulum, a rare echocardiographic finding: two adult patients and review of the literature.

    abstract::Congenital diverticulum of the left ventricle is a very rare cardiac abnormality characterized by a local embryological development failure of the ventricular muscle. It may present as an isolated disorder or may be associated with other cardiac abnormalities. Clinically, it has been reported that it can lead to chest...

    journal_title:Cardiology journal

    pub_type: 杂志文章,评审

    doi:

    authors: Cianciulli TF,Del Carmen Gonzalez Colaso P,Saccheri MC,Lax JA,Redruello HJ,Guerra JE,Prezioso HA,Vidal LA

    更新日期:2009-01-01 00:00:00

  • Implantation of bioresorbable scaffolds under guidance of optical coherence tomography: Feasibility and pilot clinical results of a systematic protocol.

    abstract:BACKGROUND:Herein is hypothesised that a comprehensive optical coherence tomography (OCT)-guided implantation protocol for bioresorbable scaffolds (BRS) can improve expansion and apposition, thus resulting in better clinical outcomes, particularly in reducing thrombotic events. METHODS:Patients considered suitable for...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2018.0055

    authors: Gutiérrez-Chico JL,Cortés C,Schincariol M,Limon U,Yalcinli M,Durán-Cortés MA,Jaguszewski M

    更新日期:2018-01-01 00:00:00

  • Long time clinical outcomes of limus-eluting stent versus paclitaxel-eluting stent in patients undergoing percutaneous coronary artery intervention: A meta-analysis of randomized controlled clinical trials.

    abstract:BACKGROUND:The meta-analysis was aimed to compare the long time (> 2 year) clinical outcomes of limus-based stents (LBS) and paclitaxel-eluting stents (PES). LBS and PES are two kinds of most common coronary artery stents in clinics. METHODS:Electronic data bases of PubMed, Cochrane, and EMBASE were searched. We inclu...

    journal_title:Cardiology journal

    pub_type: 杂志文章,meta分析,评审

    doi:10.5603/CJ.a2014.0004

    authors: Gao L,Hu X,Hou Y,Xue Q

    更新日期:2014-01-01 00:00:00

  • The effectiveness of transvenous leads extractions implanted more than 10 years before.

    abstract:BACKGROUND:The increasing number of patients with cardiac implantable electronic devices (CIEDs) causes a rise in the absolute percentage of individuals qualifying for a transvenous lead extraction (TLE) due to infectious, vascular or lead failure related indications. As the survival time prolongs, TLE procedures more ...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2013.0143

    authors: Maciąg A,Syska P,Przybylski A,Kuśmierski K,Sterliński M,Oręziak A,Pytkowski M,Różański J,Szwed H

    更新日期:2014-01-01 00:00:00

  • Predicted and observed in-hospital mortality after left main coronary artery stenting in 204 patients.

    abstract:BACKGROUND:The purpose of this study was to compare risk predicted using available risk scores and actual outcomes in patients with left main coronary artery disease undergoing percutaneous coronary intervention with stent implantation (PCI LM). METHODS:We studied 204 patients treated with elective or emergent coronar...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:

    authors: Sukiennik A,Ostrowska-Nowak J,Wiśniewska-Szmyt J,Radomski M,Rychter M,Jabłoński M,Białoszyński T,Koziński M,Fabiszak T,Dobosiewicz R,Zabielska E,Sukiennik T,Kubica A,Król A,Demidowicz K,Chojnicki M,Grabczewska Z,Swiatki

    更新日期:2008-01-01 00:00:00

  • Evaluation of exercise capacity with cardiopulmonary exercise test and B-type natriuretic peptide in adults with congenital heart disease.

    abstract:BACKGROUND:Adult patients with congenital heart disease (CHD) usually find their exercise capacity satisfactory. However, objective evaluation is important for diagnostic and prognostic purposes. The aim of this study was to evaluate exercise capacity using cardiopulmonary exercise tests and measurement of serum B-type...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:

    authors: Trojnarska O,Gwizdała A,Katarzyński S,Katarzyńska A,Szyszka A,Lanocha M,Grajek S,Kramer L

    更新日期:2009-01-01 00:00:00

  • Acute and mid-term outcomes of transvenous implant of a new left ventricular quadripolar lead versus bipolar leads for cardiac resynchronization therapy: results from a single-center prospective database.

    abstract:BACKGROUND:The purpose of this study was to evaluate the feasibility of the use of a quadripolar left ventricular (LV) lead for cardiac resynchronization therapy and to compare its acute and mid-term outcomes with those obtained with bipolar leads. Cardiac resynchronization exhibits a high incidence of problems involvi...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/cj.2012.0087

    authors: Arias MA,Pachón M,Puchol A,Jiménez-López J,Rodríguez-Padial L

    更新日期:2012-01-01 00:00:00

  • Does non-pharmacological treatment affect outcomes in dysautonomic syndromes?

    abstract::Dysautonomic syndromes are very common clinical conditions with different presentations and a wide spectrum of mechanisms. Many non-pharmacological and pharmacological interventions have been recommended to treat dysautonomic patients along these years, but the majority of them were not supported by multicenter contro...

    journal_title:Cardiology journal

    pub_type: 杂志文章,评审

    doi:10.5603/CJ.2014.0093

    authors: Hachul D

    更新日期:2014-01-01 00:00:00

  • Catheter entrapment due to severe radial artery spasm during transradial approach.

    abstract:BACKGROUND:Catheter entrapment due to severe radial artery spasm (RAS) during transradial coronary catheterization has been rarely reported and its management is not precisely defined. The aim of this study was to determine the incidence, predictors and management of catheter entrapment due to severe RAS. METHODS:A to...

    journal_title:Cardiology journal

    pub_type: 杂志文章

    doi:10.5603/CJ.a2016.0022

    authors: Zencirci E,Değirmencioğlu A

    更新日期:2016-01-01 00:00:00