A task-specific interactive game-based virtual reality rehabilitation system for patients with stroke: a usability test and two clinical experiments.

Abstract:

BACKGROUND:Virtual reality (VR) is not commonly used in clinical rehabilitation, and commercial VR gaming systems may have mixed effects in patients with stroke. Therefore, we developed RehabMaster™, a task-specific interactive game-based VR system for post-stroke rehabilitation of the upper extremities, and assessed its usability and clinical efficacy. METHODS:A participatory design and usability tests were carried out for development of RehabMaster with representative user groups. Two clinical trials were then performed. The first was an observational study in which seven patients with chronic stroke received 30 minutes of RehabMaster intervention per day for two weeks. The second was a randomised controlled trial of 16 patients with acute or subacute stroke who received 10 sessions of conventional occupational therapy only (OT-only group) or conventional occupational therapy plus 20 minutes of RehabMaster intervention (RehabMaster + OT group). The Fugl-Meyer Assessment score (FMA), modified Barthel Index (MBI), adverse effects, and drop-out rate were recorded. RESULTS:The requirements of a VR system for stroke rehabilitation were established and incorporated into RehabMaster. The reported advantages from the usability tests were improved attention, the immersive flow experience, and individualised intervention. The first clinical trial showed that the RehabMaster intervention improved the FMA (P = .03) and MBI (P = .04) across evaluation times. The second trial revealed that the addition of RehabMaster intervention tended to enhance the improvement in the FMA (P = .07) but did not affect the improvement in the MBI. One patient with chronic stroke left the trial, and no adverse effects were reported. CONCLUSIONS:The RehabMaster is a feasible and safe VR system for enhancing upper extremity function in patients with stroke.

journal_name

J Neuroeng Rehabil

authors

Shin JH,Ryu H,Jang SH

doi

10.1186/1743-0003-11-32

subject

Has Abstract

pub_date

2014-03-06 00:00:00

pages

32

issn

1743-0003

pii

1743-0003-11-32

journal_volume

11

pub_type

杂志文章,随机对照试验
  • The application of precisely controlled functional electrical stimulation to the shoulder, elbow and wrist for upper limb stroke rehabilitation: a feasibility study.

    abstract:BACKGROUND:Functional electrical stimulation (FES) during repetitive practice of everyday tasks can facilitate recovery of upper limb function following stroke. Reduction in impairment is strongly associated with how closely FES assists performance, with advanced iterative learning control (ILC) technology providing pr...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/1743-0003-11-105

    authors: Meadmore KL,Exell TA,Hallewell E,Hughes AM,Freeman CT,Kutlu M,Benson V,Rogers E,Burridge JH

    更新日期:2014-06-30 00:00:00

  • Using non-invasive brain stimulation to augment motor training-induced plasticity.

    abstract::Therapies for motor recovery after stroke or traumatic brain injury are still not satisfactory. To date the best approach seems to be the intensive physical therapy. However the results are limited and functional gains are often minimal. The goal of motor training is to minimize functional disability and optimize func...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章,评审

    doi:10.1186/1743-0003-6-8

    authors: Bolognini N,Pascual-Leone A,Fregni F

    更新日期:2009-03-17 00:00:00

  • Toward brain-computer interface based wheelchair control utilizing tactually-evoked event-related potentials.

    abstract:BACKGROUND:People with severe disabilities, e.g., due to neurodegenerative disease, depend on technology that allows for accurate wheelchair control. For those who cannot operate a wheelchair with a joystick, brain-computer interfaces (BCI) may offer a valuable option. Technology depending on visual or auditory input m...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-11-7

    authors: Kaufmann T,Herweg A,Kübler A

    更新日期:2014-01-16 00:00:00

  • Reliability of movement workspace measurements in a passive arm orthosis used in spinal cord injury rehabilitation.

    abstract:BACKGROUND:Robotic and non-robotic training devices are increasingly being used in the rehabilitation of upper limb function in subjects with neurological disorders. As well as being used for training such devices can also provide ongoing assessments during the training sessions. Therefore, it is mandatory to understan...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-9-37

    authors: Rudhe C,Albisser U,Starkey ML,Curt A,Bolliger M

    更新日期:2012-06-09 00:00:00

  • EEG response varies with lesion location in patients with chronic stroke.

    abstract:BACKGROUND:Brain activation differs according to lesion location in functional magnetic resonance imaging (fMRI) studies, but lesion location-dependent electroencephalographic (EEG) alterations are unclear. Because of the increasing use of EEG-based brain-computer-interface rehabilitation, we examined lesion location-d...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-016-0120-2

    authors: Park W,Kwon GH,Kim YH,Lee JH,Kim L

    更新日期:2016-03-02 00:00:00

  • The FreeD module for the Lokomat facilitates a physiological movement pattern in healthy people - a proof of concept study.

    abstract:BACKGROUND:A contralateral pelvic drop, a transverse rotation and a lateral translation of the pelvis are essential features of normal human gait. These motions are often restricted in robot-assisted gait devices. The optional FreeD module of the driven gait orthosis Lokomat (Hocoma AG, Switzerland) incorporates guided...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-019-0496-x

    authors: Aurich-Schuler T,Gut A,Labruyère R

    更新日期:2019-02-06 00:00:00

  • Reweighting of the sensory inputs for postural control in patients with cervical spondylotic myelopathy after surgery.

    abstract:BACKGROUND:Cervical spondylotic myelopathy (CSM) is a degenerative cervical disease in which the spinal cord is compressed. Patients with CSM experience balance disturbance because of impaired proprioception. The weighting of the sensory inputs for postural control in patients with CSM is unclear. Therefore, this study...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-019-0564-2

    authors: Lin IS,Lai DM,Ding JJ,Chien A,Cheng CH,Wang SF,Wang JL,Kuo CL,Hsu WL

    更新日期:2019-07-25 00:00:00

  • Design strategies to improve patient motivation during robot-aided rehabilitation.

    abstract:BACKGROUND:Motivation is an important factor in rehabilitation and frequently used as a determinant of rehabilitation outcome. Several factors can influence patient motivation and so improve exercise adherence. This paper presents the design of two robot devices for use in the rehabilitation of upper limb movements, th...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/1743-0003-4-3

    authors: Colombo R,Pisano F,Mazzone A,Delconte C,Micera S,Carrozza MC,Dario P,Minuco G

    更新日期:2007-02-19 00:00:00

  • Effects of kinematic vibrotactile feedback on learning to control a virtual prosthetic arm.

    abstract:BACKGROUND:After a limb is lost a prosthesis can restore function. For maximum utility, prosthetic limbs should accept movement commands and provide force and motion feedback, which can be conveyed with vibrotactile feedback (VIBF). While prior studies have shown that force-based VIBF benefits control, the merits of mo...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-015-0025-5

    authors: Hasson CJ,Manczurowsky J

    更新日期:2015-03-24 00:00:00

  • Assessment of dynamic balancing responses following perturbations during slow walking in relation to clinical outcome measures for high-functioning post-stroke subjects.

    abstract:BACKGROUND:Generating appropriate balancing reactions in response to unexpected loss of balance during walking is important to prevent falls. The purpose of this study was to assess dynamic balancing responses following pushes to the pelvis in groups of post-stroke and healthy subjects. METHODS:Forty-one post-stroke s...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-020-00710-5

    authors: Zadravec M,Olenšek A,Rudolf M,Bizovičar N,Goljar N,Matjačić Z

    更新日期:2020-07-02 00:00:00

  • Exercise self-efficacy and the relation with physical behavior and physical capacity in wheelchair-dependent persons with subacute spinal cord injury.

    abstract:BACKGROUND:Since physical activity and exercise levels are known to be generally low in persons with spinal cord injury (SCI), there seems to be a need for intervention. Exercise self-efficacy (ESE), the confidence persons have in their ability to be physically active and exercise, is an important and modifiable predic...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-015-0099-0

    authors: Nooijen CF,Post MW,Spooren AL,Valent LJ,Broeksteeg R,Sluis TA,Stam HJ,Act-Active Research Group.,van den Berg-Emons RJ

    更新日期:2015-11-19 00:00:00

  • Physical activity monitoring in obese people in the real life environment.

    abstract:BACKGROUND:Obesity is a major problem especially in western countries and several studies underline the importance of physical activity to enhance diet. Currently there is increasing interest in instruments for monitoring daily physical activity. The purpose of this pilot study was to appraise the qualitative and quant...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-6-47

    authors: Benedetti MG,Di Gioia A,Conti L,Berti L,Degli Esposti L,Tarrini G,Melchionda N,Giannini S

    更新日期:2009-12-30 00:00:00

  • Inertial sensor-based gait parameters reflect patient-reported fatigue in multiple sclerosis.

    abstract:BACKGROUND:Multiple sclerosis (MS) is a disabling disease affecting the central nervous system and consequently the whole body's functional systems resulting in different gait disorders. Fatigue is the most common symptom in MS with a prevalence of 80%. Previous research studied the relation between fatigue and gait im...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-020-00798-9

    authors: Ibrahim AA,Küderle A,Gaßner H,Klucken J,Eskofier BM,Kluge F

    更新日期:2020-12-18 00:00:00

  • Dual-task training of children with neuromotor disorders during robot-assisted gait therapy: prerequisites of patients and influence on leg muscle activity.

    abstract:BACKGROUND:Walking in daily life is complex entailing various prerequisites such as leg strength, trunk stability or cognitive and motor dual task (DT) activities. Conventional physiotherapy can be complemented with robot-assisted gait therapy (RAGT) and exergames to enhance the number of step repetitions, feedback, mo...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/s12984-018-0426-3

    authors: Ricklin S,Meyer-Heim A,van Hedel HJA

    更新日期:2018-09-17 00:00:00

  • Erratum to: Design and pilot validation of A-gear: a novel wearable dynamic arm support.

    abstract::Unfortunately, the original version of this article [1] contained an error. Equation 6 was included incorrectly: in the original equation variable slinks3 was missing.The correct Equation 6 can be found below: ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 已发布勘误

    doi:10.1186/s12984-015-0106-5

    authors: Kooren PN,Dunning AG,Janssen MM,Lobo-Prat J,Koopman BF,Paalman MI,de Groot IJ,Herder JL

    更新日期:2015-12-04 00:00:00

  • The effects of gait training using powered lower limb exoskeleton robot on individuals with complete spinal cord injury.

    abstract:BACKGROUND:Powered exoskeleton can improve the mobility for people with movement deficits by providing mechanical support and facilitate the gait training. This pilot study evaluated the effect of gait training using a newly developed powered lower limb exoskeleton robot for individuals with complete spinal cord injury...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-018-0355-1

    authors: Wu CH,Mao HF,Hu JS,Wang TY,Tsai YJ,Hsu WL

    更新日期:2018-03-05 00:00:00

  • Plantar flexion force induced by amplitude-modulated tendon vibration and associated soleus V/F-waves as an evidence of a centrally-mediated mechanism contributing to extra torque generation in humans.

    abstract:BACKGROUND:High-frequency trains of electrical stimulation applied over the human muscles can generate forces higher than would be expected by direct activation of motor axons, as evidenced by an unexpected relation between the stimuli and the evoked contractions, originating what has been called "extra forces". This p...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-10-32

    authors: Magalhães FH,de Toledo DR,Kohn AF

    更新日期:2013-03-25 00:00:00

  • Research highlights in neurorehabilitation.

    abstract::Recent studies of the mechanisms underlying plasticity and recovery following neurological injuries have originated innovative lines of research in neurorehabilitation. Additionally, the development of new technologies to facilitate the performance of evaluation and intervention procedures has stimulated research on n...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 社论

    doi:10.1186/1743-0003-11-21

    authors: Pajaro-Blázquez M,Pons JL

    更新日期:2014-03-04 00:00:00

  • Advancing quantitative techniques to improve understanding of the skeletal structure-function relationship.

    abstract::Although all functional movement arises from the interplay between the neurological, skeletal, and muscular systems, it is the skeletal system that forms the basic framework for functional movement. Central to understanding human neuromuscular development, along with the genesis of musculoskeletal pathologies, is quan...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章,评审

    doi:10.1186/s12984-018-0368-9

    authors: Sheehan FT,Brainerd EL,Troy KL,Shefelbine SJ,Ronsky JL

    更新日期:2018-03-20 00:00:00

  • Adaptive training algorithm for robot-assisted upper-arm rehabilitation, applicable to individualised and therapeutic human-robot interaction.

    abstract:BACKGROUND:Rehabilitation robotics is progressing towards developing robots that can be used as advanced tools to augment the role of a therapist. These robots are capable of not only offering more frequent and more accessible therapies but also providing new insights into treatment effectiveness based on their ability...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-10-102

    authors: Chemuturi R,Amirabdollahian F,Dautenhahn K

    更新日期:2013-09-28 00:00:00

  • A bi-articular model for scapular-humeral rhythm reconstruction through data from wearable sensors.

    abstract:BACKGROUND:Patient-specific performance assessment of arm movements in daily life activities is fundamental for neurological rehabilitation therapy. In most applications, the shoulder movement is simplified through a socket-ball joint, neglecting the movement of the scapular-thoracic complex. This may lead to significa...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-016-0149-2

    authors: Lorussi F,Carbonaro N,De Rossi D,Tognetti A

    更新日期:2016-04-23 00:00:00

  • Effects of a powered ankle-foot prosthesis on kinetic loading of the unaffected leg during level-ground walking.

    abstract:BACKGROUND:People with a lower-extremity amputation that use conventional passive-elastic ankle-foot prostheses encounter a series of stress-related challenges during walking such as greater forces on their unaffected leg, and may thus be predisposed to secondary musculoskeletal injuries such as chronic joint disorders...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-10-49

    authors: Grabowski AM,D'Andrea S

    更新日期:2013-06-07 00:00:00

  • Subthalamic deep brain stimulation improves smooth pursuit and saccade performance in patients with Parkinson's disease.

    abstract:BACKGROUND:Deep brain stimulation (DBS) in the subthalamic nucleus (STN) significantly reduces symptoms of Parkinson's disease (PD) such as bradykinesia, tremor and rigidity. It also reduces the need for anti-PD medication, and thereby potential side-effects of L-Dopa. Although DBS in the STN is a highly effective ther...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-10-33

    authors: Nilsson MH,Patel M,Rehncrona S,Magnusson M,Fransson PA

    更新日期:2013-04-03 00:00:00

  • Gait characteristics of subjects with chronic fatigue syndrome and controls at self-selected and matched velocities.

    abstract:BACKGROUND:Gait abnormalities have been reported in individuals with Chronic Fatigue Syndrome (CFS) however no studies exist to date investigating the kinematics of individuals with CFS in over-ground gait. The aim of this study was to compare the over-ground gait pattern (sagittal kinematics and temporal and spatial) ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-5-16

    authors: Paul L,Rafferty D,Wood L,Maclaren W

    更新日期:2008-05-27 00:00:00

  • Commercial head-mounted display virtual reality for upper extremity rehabilitation in chronic stroke: a single-case design study.

    abstract:BACKGROUND:Rehabilitation is crucial for maximizing recovery after stroke. Rehabilitation activities that are fun and rewarding by themselves can be more effective than those who are not. Gamification with virtual reality (VR) exploits this principle. This single-case design study probes the potential for using commerc...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-020-00788-x

    authors: Erhardsson M,Alt Murphy M,Sunnerhagen KS

    更新日期:2020-11-23 00:00:00

  • Leg joint power output during progressive resistance FES-LCE cycling in SCI subjects: developing an index of fatigue.

    abstract:BACKGROUND:The purpose of this study was to investigate the biomechanics of the hip, knee and ankle during a progressive resistance cycling protocol in an effort to detect and measure the presence of muscle fatigue. It was hypothesized that knee power output can be used as an indicator of fatigue in order to assess the...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-5-14

    authors: Haapala SA,Faghri PD,Adams DJ

    更新日期:2008-04-26 00:00:00

  • Time and frequency domain methods for quantifying common modulation of motor unit firing patterns.

    abstract::BACKGROUND: In investigations of the human motor system, two approaches are generally employed toward the identification of common modulating drives from motor unit recordings. One is a frequency domain method and uses the coherence function to determine the degree of linear correlation between each frequency componen...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-1-2

    authors: Myers LJ,Erim Z,Lowery MM

    更新日期:2004-10-14 00:00:00

  • Toward a hybrid brain-computer interface based on repetitive visual stimuli with missing events.

    abstract:BACKGROUND:Steady-state visually evoked potentials (SSVEPs) can be elicited by repetitive stimuli and extracted in the frequency domain with satisfied performance. However, the temporal information of such stimulus is often ignored. In this study, we utilized repetitive visual stimuli with missing events to present a n...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-016-0179-9

    authors: Wu Y,Li M,Wang J

    更新日期:2016-07-26 00:00:00

  • Influences of the biofeedback content on robotic post-stroke gait rehabilitation: electromyographic vs joint torque biofeedback.

    abstract:BACKGROUND:Add-on robot-mediated therapy has proven to be more effective than conventional therapy alone in post-stroke gait rehabilitation. Such robot-mediated interventions routinely use also visual biofeedback tools. A better understanding of biofeedback content effects when used for robotic locomotor training may i...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章,随机对照试验

    doi:10.1186/s12984-019-0558-0

    authors: Tamburella F,Moreno JC,Herrera Valenzuela DS,Pisotta I,Iosa M,Cincotti F,Mattia D,Pons JL,Molinari M

    更新日期:2019-07-23 00:00:00

  • Automatic identification of gait events using an instrumented sock.

    abstract:BACKGROUND:Textile-based transducers are an emerging technology in which piezo-resistive properties of materials are used to measure an applied strain. By incorporating these sensors into a sock, this technology offers the potential to detect critical events during the stance phase of the gait cycle. This could prove u...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-8-32

    authors: Preece SJ,Kenney LP,Major MJ,Dias T,Lay E,Fernandes BT

    更新日期:2011-05-27 00:00:00