Design and evaluation of a low-cost instrumented glove for hand function assessment.

Abstract:

BACKGROUND:The evaluation of hand function impairment following a neurological disorder (stroke and cervical spinal cord injury) requires sensitive, reliable and clinically meaningful assessment tools. Clinical performance measures of hand function mainly focus on the accomplishment of activities of daily living (ADL), typically rather complex tasks assessed by a gross ordinal rating; while the motor performance (i.e. kinematics) is less detailed. The goal of this study was to develop a low-cost instrumented glove to capture details in grasping, feasible for the assessment of hand function in clinical practice and rehabilitation settings. METHODS:Different sensor types were tested for output signal stability over time by measuring the signal drift of their step responses. A system that converted sensor output voltages into angles based on pre-measured curves was implemented. Furthermore, the voltage supply of each sensor signal conditioning circuit was increased to enhance the sensor resolution. The repeatability of finger bending trajectories, recorded during the performance of three ADL-based tasks, was established using the intraclass correlation coefficient (ICC). Moreover, the accuracy of the glove was evaluated by determining the agreement between angles measured with the embedded sensors and angles measured by traditional goniometry. In addition, the feasibility of the glove was tested in four patients with a pathological hand function caused by a cervical spinal cord injury (cSCI). RESULTS:A sensor type that displayed a stable output signal over time was identified, and a high sensor resolution of 0.5° was obtained. The evaluation of the glove's reliability yielded high ICC values (0.84 to 0.92) with an accuracy error of about ± 5°. Feasibility testing revealed that the glove was sensitive to distinguish different levels of hand function impairment in cSCI patients. CONCLUSIONS:The device satisfied the desired system requirements in terms of low cost, stable sensor signal over time, full finger-flexion range of motion tracking and capability to monitor all three joints of one finger. The developed rapid calibration system for easy use (high feasibility) and excellent psychometric properties (i.e. reliability and validity) qualify the device for the assessment of hand function in clinical practice and rehabilitation settings.

journal_name

J Neuroeng Rehabil

authors

Oess NP,Wanek J,Curt A

doi

10.1186/1743-0003-9-2

subject

Has Abstract

pub_date

2012-01-17 00:00:00

pages

2

issn

1743-0003

pii

1743-0003-9-2

journal_volume

9

pub_type

杂志文章
  • Proportional estimation of finger movements from high-density surface electromyography.

    abstract:BACKGROUND:The importance to restore the hand function following an injury/disease of the nervous system led to the development of novel rehabilitation interventions. Surface electromyography can be used to create a user-driven control of a rehabilitation robot, in which the subject needs to engage actively, by using s...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-016-0172-3

    authors: Celadon N,Došen S,Binder I,Ariano P,Farina D

    更新日期:2016-08-04 00:00:00

  • Recalibrating disparities in perceived and actual balance abilities in older adults: a mixed-methods evaluation of a novel exergaming intervention.

    abstract:BACKGROUND:Published reports suggest a disparity between perceived and actual balance abilities, a trait associated with increased fall-risk in older adults. We investigate whether it is possible to 'recalibrate' these disparities using a novel gaming intervention. METHODS:We recruited 26 older adults for a 4-week int...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/s12984-018-0369-8

    authors: Ellmers TJ,Paraskevopoulos IT,Williams AM,Young WR

    更新日期:2018-03-22 00:00:00

  • Gait characteristics of subjects with chronic fatigue syndrome and controls at self-selected and matched velocities.

    abstract:BACKGROUND:Gait abnormalities have been reported in individuals with Chronic Fatigue Syndrome (CFS) however no studies exist to date investigating the kinematics of individuals with CFS in over-ground gait. The aim of this study was to compare the over-ground gait pattern (sagittal kinematics and temporal and spatial) ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-5-16

    authors: Paul L,Rafferty D,Wood L,Maclaren W

    更新日期:2008-05-27 00:00:00

  • Lower-extremity joint kinematics and muscle activations during semi-reclined cycling at different workloads in healthy individuals.

    abstract:BACKGROUND:A better understanding of lower-extremity muscles' activation patterns and joint kinematics during different workloads could help rehabilitation professionals with prescribing more effective exercise regimen for elderly and those with compromised muscles. We examined the relative contribution, as well as act...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-11-146

    authors: Momeni K,Faghri PD,Evans M

    更新日期:2014-10-17 00:00:00

  • Feasibility and effects of patient-cooperative robot-aided gait training applied in a 4-week pilot trial.

    abstract:BACKGROUND:Functional training is becoming the state-of-the-art therapy approach for rehabilitation of individuals after stroke and spinal cord injury. Robot-aided treadmill training reduces personnel effort, especially when treating severely affected patients. Improving rehabilitation robots towards more patient-coope...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/1743-0003-9-31

    authors: Schück A,Labruyère R,Vallery H,Riener R,Duschau-Wicke A

    更新日期:2012-05-31 00:00:00

  • Control of cortical oscillatory frequency by a closed-loop system.

    abstract:BACKGROUND:We present a closed-loop system able to control the frequency of slow oscillations (SO) spontaneously generated by the cortical network in vitro. The frequency of SO can be controlled by direct current (DC) electric fields within a certain range. Here we set out to design a system that would be able to auton...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-018-0470-z

    authors: D'Andola M,Giulioni M,Dante V,Del Giudice P,Sanchez-Vives MV

    更新日期:2019-01-09 00:00:00

  • Effects of extended powered knee prosthesis stance time via visual feedback on gait symmetry of individuals with unilateral amputation: a preliminary study.

    abstract:BACKGROUND:Establishing gait symmetry is a major aim of amputee rehabilitation and may be more attainable with powered prostheses. Though, based on previous work, we postulate that users transfer a previously-learned motor pattern across devices, limiting the functionality of more advanced prostheses. The objective of ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-019-0583-z

    authors: Brandt A,Riddick W,Stallrich J,Lewek M,Huang HH

    更新日期:2019-09-11 00:00:00

  • Self-adaptive robot training of stroke survivors for continuous tracking movements.

    abstract:BACKGROUND:Although robot therapy is progressively becoming an accepted method of treatment for stroke survivors, few studies have investigated how to adapt the robot/subject interaction forces in an automatic way. The paper is a feasibility study of a novel self-adaptive robot controller to be applied with continuous ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-7-13

    authors: Vergaro E,Casadio M,Squeri V,Giannoni P,Morasso P,Sanguineti V

    更新日期:2010-03-15 00:00:00

  • Toward a hybrid brain-computer interface based on repetitive visual stimuli with missing events.

    abstract:BACKGROUND:Steady-state visually evoked potentials (SSVEPs) can be elicited by repetitive stimuli and extracted in the frequency domain with satisfied performance. However, the temporal information of such stimulus is often ignored. In this study, we utilized repetitive visual stimuli with missing events to present a n...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-016-0179-9

    authors: Wu Y,Li M,Wang J

    更新日期:2016-07-26 00:00:00

  • Pathway-specific modulatory effects of neuromuscular electrical stimulation during pedaling in chronic stroke survivors.

    abstract:BACKGROUND:Neuromuscular electrical stimulation (NMES) is extensively used in stroke motor rehabilitation. How it promotes motor recovery remains only partially understood. NMES could change muscular properties, produce altered sensory inputs, and modulate fluctuations of cortical activities; but the potential contribu...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-019-0614-9

    authors: Bao SC,Leung WC,K Cheung VC,Zhou P,Tong KY

    更新日期:2019-11-19 00:00:00

  • Time and frequency domain methods for quantifying common modulation of motor unit firing patterns.

    abstract::BACKGROUND: In investigations of the human motor system, two approaches are generally employed toward the identification of common modulating drives from motor unit recordings. One is a frequency domain method and uses the coherence function to determine the degree of linear correlation between each frequency componen...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-1-2

    authors: Myers LJ,Erim Z,Lowery MM

    更新日期:2004-10-14 00:00:00

  • Obituary: Yukio Mano (1943-2004).

    abstract::Yukio Mano, MD, PhD (1943-2004)Associate Editor, Journal of NeuroEngineering and Rehabilitation. ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-2-1

    authors: Ikoma K

    更新日期:2005-02-24 00:00:00

  • Detecting compensatory movements of stroke survivors using pressure distribution data and machine learning algorithms.

    abstract:BACKGROUND:Compensatory movements are commonly employed by stroke survivors during seated reaching and may have negative effects on their long-term recovery. Detecting compensation is useful for coaching the patient to reduce compensatory trunk movements and improving the motor function of the paretic arm. Sensor-based...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-019-0609-6

    authors: Cai S,Li G,Zhang X,Huang S,Zheng H,Ma K,Xie L

    更新日期:2019-11-04 00:00:00

  • Computer simulations of neural mechanisms explaining upper and lower limb excitatory neural coupling.

    abstract:BACKGROUND:When humans perform rhythmic upper and lower limb locomotor-like movements, there is an excitatory effect of upper limb exertion on lower limb muscle recruitment. To investigate potential neural mechanisms for this behavioral observation, we developed computer simulations modeling interlimb neural pathways a...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-7-59

    authors: Huang HJ,Ferris DP

    更新日期:2010-12-10 00:00:00

  • The effects of error-augmentation versus error-reduction paradigms in robotic therapy to enhance upper extremity performance and recovery post-stroke: a systematic review.

    abstract::Despite upper extremity function playing a crucial role in maintaining one's independence in activities of daily living, upper extremity impairments remain one of the most prevalent post-stroke deficits. To enhance the upper extremity motor recovery and performance among stroke survivors, two training paradigms in the...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-018-0408-5

    authors: Liu LY,Li Y,Lamontagne A

    更新日期:2018-07-04 00:00:00

  • Adaptive robot training for the treatment of incoordination in Multiple Sclerosis.

    abstract:BACKGROUND:Cerebellar symptoms are extremely disabling and are common in Multiple Sclerosis (MS) subjects. In this feasibility study, we developed and tested a robot therapy protocol, aimed at the rehabilitation of incoordination in MS subjects. METHODS:Eight subjects with clinically defined MS performed planar reachi...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章,随机对照试验

    doi:10.1186/1743-0003-7-37

    authors: Vergaro E,Squeri V,Brichetto G,Casadio M,Morasso P,Solaro C,Sanguineti V

    更新日期:2010-07-29 00:00:00

  • Automatic identification of gait events using an instrumented sock.

    abstract:BACKGROUND:Textile-based transducers are an emerging technology in which piezo-resistive properties of materials are used to measure an applied strain. By incorporating these sensors into a sock, this technology offers the potential to detect critical events during the stance phase of the gait cycle. This could prove u...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-8-32

    authors: Preece SJ,Kenney LP,Major MJ,Dias T,Lay E,Fernandes BT

    更新日期:2011-05-27 00:00:00

  • Quantifying forearm and wrist joint power during unconstrained movements in healthy individuals.

    abstract:BACKGROUND:Wrist movement-related injuries account for a large number of repetitive motion injuries. Remarkably little, if any, empirical data exist to quantify the impact of neuromuscular disorders affecting the wrist or to validate the effectiveness of rehabilitation training programs on wrist functions. The aim of t...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-11-157

    authors: Flores DC,Laurendeau S,Teasdale N,Simoneau M

    更新日期:2014-11-17 00:00:00

  • Intention tremor and deficits of sensory feedback control in multiple sclerosis: a pilot study.

    abstract:BACKGROUND:Intention tremor and dysmetria are leading causes of upper extremity disability in Multiple Sclerosis (MS). The development of effective therapies to reduce tremor and dysmetria is hampered by insufficient understanding of how the distributed, multi-focal lesions associated with MS impact sensorimotor contro...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-11-170

    authors: Heenan M,Scheidt RA,Woo D,Beardsley SA

    更新日期:2014-12-19 00:00:00

  • Can Lokomat therapy with children and adolescents be improved? An adaptive clinical pilot trial comparing Guidance force, Path control, and FreeD.

    abstract:BACKGROUND:Robot-assisted gait therapy is increasingly being used in pediatric neurorehabilitation to complement conventional physical therapy. The robotic device applied in this study, the Lokomat (Hocoma AG, Switzerland), uses a position control mode (Guidance Force), where exact positions of the knee and hip joints ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/s12984-017-0287-1

    authors: Aurich-Schuler T,Grob F,van Hedel HJA,Labruyère R

    更新日期:2017-07-14 00:00:00

  • Factors influencing outcomes after medial hamstring lengthening with semitendinosus transfer in patients with cerebral palsy.

    abstract:BACKGROUND:Although several studies have investigated the outcomes after distal hamstring lengthening (DHL), no study has undertaken an approach that included all or most of the important factors that could influence the results. This study was performed to evaluate the outcomes after DHL and analyze the factors that i...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-017-0296-0

    authors: Sung KH,Lee J,Chung CY,Lee KM,Cho BC,Moon SJ,Kim J,Park MS

    更新日期:2017-08-14 00:00:00

  • Transcranial magnetic stimulation, synaptic plasticity and network oscillations.

    abstract::Transcranial magnetic stimulation (TMS) has quickly progressed from a technical curiosity to a bona-fide tool for neurological research. The impetus has been due to the promising results obtained when using TMS to uncover neural processes in normal human subjects, as well as in the treatment of intractable neurologica...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章,评审

    doi:10.1186/1743-0003-6-7

    authors: Huerta PT,Volpe BT

    更新日期:2009-03-02 00:00:00

  • Dual-task training of children with neuromotor disorders during robot-assisted gait therapy: prerequisites of patients and influence on leg muscle activity.

    abstract:BACKGROUND:Walking in daily life is complex entailing various prerequisites such as leg strength, trunk stability or cognitive and motor dual task (DT) activities. Conventional physiotherapy can be complemented with robot-assisted gait therapy (RAGT) and exergames to enhance the number of step repetitions, feedback, mo...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 临床试验,杂志文章

    doi:10.1186/s12984-018-0426-3

    authors: Ricklin S,Meyer-Heim A,van Hedel HJA

    更新日期:2018-09-17 00:00:00

  • The FreeD module for the Lokomat facilitates a physiological movement pattern in healthy people - a proof of concept study.

    abstract:BACKGROUND:A contralateral pelvic drop, a transverse rotation and a lateral translation of the pelvis are essential features of normal human gait. These motions are often restricted in robot-assisted gait devices. The optional FreeD module of the driven gait orthosis Lokomat (Hocoma AG, Switzerland) incorporates guided...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-019-0496-x

    authors: Aurich-Schuler T,Gut A,Labruyère R

    更新日期:2019-02-06 00:00:00

  • Test-retest reliability of stride time variability while dual tasking in healthy and demented adults with frontotemporal degeneration.

    abstract:BACKGROUND:Although test-retest reliability of mean values of spatio-temporal gait parameters has been assessed for reliability while walking alone (i.e., single tasking), little is known about the test-retest reliability of stride time variability (STV) while performing an attention demanding-task (i.e., dual tasking)...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-8-37

    authors: Beauchet O,Freiberger E,Annweiler C,Kressig RW,Herrmann FR,Allali G

    更新日期:2011-07-11 00:00:00

  • Development of VariLeg, an exoskeleton with variable stiffness actuation: first results and user evaluation from the CYBATHLON 2016.

    abstract:BACKGROUND:Powered exoskeletons are a promising approach to restore the ability to walk after spinal cord injury (SCI). However, current exoskeletons remain limited in their walking speed and ability to support tasks of daily living, such as stair climbing or overcoming ramps. Moreover, training progress for such advan...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-018-0360-4

    authors: Schrade SO,Dätwyler K,Stücheli M,Studer K,Türk DA,Meboldt M,Gassert R,Lambercy O

    更新日期:2018-03-13 00:00:00

  • Visualizing the third dimension in virtual training environments for neurologically impaired persons: beneficial or disruptive?

    abstract:BACKGROUND:Many contemporary systems for neurorehabilitation utilize 3D virtual environments (VEs) that allow for training patients' hand or arm movements. In the current paper we comparatively test the effectiveness of two characteristics of VEs in rehabilitation training when utilizing a 3D haptic interaction device:...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-9-73

    authors: van den Hoogen W,Feys P,Lamers I,Coninx K,Notelaers S,Kerkhofs L,Ijsselsteijn W

    更新日期:2012-10-05 00:00:00

  • Evaluation of a smartphone human activity recognition application with able-bodied and stroke participants.

    abstract:BACKGROUND:Mobile health monitoring using wearable sensors is a growing area of interest. As the world's population ages and locomotor capabilities decrease, the ability to report on a person's mobility activities outside a hospital setting becomes a valuable tool for clinical decision-making and evaluating healthcare ...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-016-0114-0

    authors: Capela NA,Lemaire ED,Baddour N,Rudolf M,Goljar N,Burger H

    更新日期:2016-01-20 00:00:00

  • Effects of the physiological parameters on the signal-to-noise ratio of single myoelectric channel.

    abstract:BACKGROUND:An important measure of the performance of a myoelectric (ME) control system for powered artificial limbs is the signal-to-noise ratio (SNR) at the output of ME channel. However, few studies illustrated the neuron-muscular interactive effects on the SNR at ME control channel output. In order to obtain a comp...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/1743-0003-4-29

    authors: Ma HT,Zhang YT

    更新日期:2007-08-08 00:00:00

  • The effects of gait training using powered lower limb exoskeleton robot on individuals with complete spinal cord injury.

    abstract:BACKGROUND:Powered exoskeleton can improve the mobility for people with movement deficits by providing mechanical support and facilitate the gait training. This pilot study evaluated the effect of gait training using a newly developed powered lower limb exoskeleton robot for individuals with complete spinal cord injury...

    journal_title:Journal of neuroengineering and rehabilitation

    pub_type: 杂志文章

    doi:10.1186/s12984-018-0355-1

    authors: Wu CH,Mao HF,Hu JS,Wang TY,Tsai YJ,Hsu WL

    更新日期:2018-03-05 00:00:00